Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Ultrasound Med Biol ; 49(11): 2346-2353, 2023 11.
Article in English | MEDLINE | ID: mdl-37573178

ABSTRACT

OBJECTIVE: Augmented reality devices are increasingly accepted in health care, though most applications involve education and pre-operative planning. A novel augmented reality ultrasound application, HoloUS, was developed for the Microsoft HoloLens 2 to project real-time ultrasound images directly into the user's field of view. In this work, we assessed the effect of using HoloUS on vascular access procedural outcomes. METHODS: A single-center user study was completed with participants with (N = 22) and without (N = 12) experience performing ultrasound-guided vascular access. Users completed a venipuncture and aspiration task a total of four times: three times on study day 1, and once on study day 2 between 2 and 4 weeks later. Users were randomized to use conventional ultrasound during either their first or second task and the HoloUS application at all other times. Task completion time, numbers of needle re-directions, head adjustments and needle visualization rates were recorded. RESULTS: For expert users, task completion time was significantly faster using HoloUS (11.5 s, interquartile range [IQR] = 6.5-23.5 s vs. 18.5 s, IQR = 11.0-36.5 s; p = 0.04). The number of head adjustments was significantly lower using the HoloUS app (1.0, IQR = 0.0-1.0 vs. 3.0, IQR = 1.0-5.0; p < 0.0001). No significant differences were identified in other measured outcomes. CONCLUSION: This is the first investigation of augmented reality-based ultrasound-guided vascular access using the second-generation HoloLens. It demonstrates equivalent procedural efficiency and accuracy, with favorable usability, ergonomics and user independence when compared with traditional ultrasound techniques.


Subject(s)
Augmented Reality , Humans , Ultrasonography , Needles , Phantoms, Imaging , Ultrasonography, Interventional/methods
2.
Lasers Surg Med ; 55(5): 480-489, 2023 07.
Article in English | MEDLINE | ID: mdl-37003294

ABSTRACT

OBJECTIVES: Postoperative bile leakage is a common complication of hepatobiliary surgery and frequently requires procedural intervention. Bile-label 760 (BL-760), a novel near-infrared dye, has emerged as a promising tool for identifying biliary structures and leakage, owing to its rapid excretion and strong bile specificity. This study aimed to assess the intraoperative detection of biliary leakage using intravenously administered BL-760 compared with intravenous (IV) and intraductal (ID) indocyanine green (ICG). MATERIALS AND METHODS: Laparotomy and segmental hepatectomy with vascular control were performed on two 25-30 kg pigs. ID ICG, IV ICG, and IV BL-760 were administered separately, followed by an examination of the liver parenchyma, cut liver edge, and extrahepatic bile ducts for areas of leakage. The duration of intra- and extrahepatic fluorescence detection was assessed, and the target-to-background (TBR) of the bile ducts to the liver parenchyma was quantitatively measured. RESULTS: In Animal 1, after intraoperative BL-760 injection, three areas of leaking bile were identified within 5 min on the cut liver edge with a TBR of 2.5-3.8 that was not apparent to the naked eye. In contrast, after IV ICG administration, the background parenchymal signal and bleeding obscured the areas of bile leakage. A second dose of BL-760 demonstrated the utility of repeated injections, confirming two of the three previously visualized areas of bile leakage and revealing one previously unseen leak. In Animal 2, neither ID ICG nor IV BL-760 injections showed obvious areas of bile leakage. However, fluorescence signals were observed within the superficial intrahepatic bile ducts after both injections. CONCLUSIONS: BL-760 enables the rapid intraoperative visualization of small biliary structures and leaks, with the benefits of fast excretion, repeatable intravenous administration, and high-fluorescence TBR in the liver parenchyma. Potential applications include the identification of bile flow in the portal plate, biliary leak or duct injury, and postoperative monitoring of drain output. A thorough assessment of the intraoperative biliary anatomy could limit the need for postoperative drain placement, a possible contributor to severe complications and postoperative bile leak.


Subject(s)
Bile , Fluorescent Dyes , Swine , Animals , Hepatectomy/adverse effects , Bile Ducts/diagnostic imaging , Bile Ducts/surgery , Bile Ducts/injuries , Indocyanine Green
3.
Article in English | MEDLINE | ID: mdl-36884271

ABSTRACT

Formation of asymmetric, rigid scar tissue known as surgical adhesions is caused by traumatic disruption of mesothelial-lined surfaces in surgery. A widely adopted prophylactic barrier material (Seprafilm) for the treatment of intra-abdominal adhesions is applied operatively as a pre-dried hydrogel sheet but has reduced translational efficacy due its brittle mechanical properties. Topically administered peritoneal dialysate (Icodextrin) and anti-inflammatory drugs have failed to prevent adhesions due to an uncontrolled release profile. Hence, inclusion of a targeted therapeutic into a solid barrier host matrix with improved mechanical properties could provide dual utility in adhesion prevention and as a surgical sealant. Spray deposition of poly(lactide-co-caprolactone) (PLCL) polymer fibers through solution blow spinning has yielded a tissue-adherent barrier material with previously reported adhesion prevention efficacy due to a surface erosion mechanism that inhibits deposition of inflamed tissue. However, such an approach uniquely presents an avenue for controlled therapeutic release through mechanisms of diffusion and degradation. Such a rate is kinetically tuned via facile blending of "high" molecular weight (HMW) and "low" molecular weight (LMW) PLCL with slow and fast biodegradation rates, respectively. Here, we explore viscoelastic blends of HMW PLCL (70% w/v) and LMW PLCL (30% w/v) as a host matrix for anti-inflammatory drug delivery. In this work, COG133, an apolipoprotein E (ApoE) mimetic peptide with potent anti-inflammatory properties was selected and tested. In vitro studies with PLCL blends presented low (∼30%) and high (∼80%) percent release profiles over a 14-day period based on the nominal molecular weight of the HMW PLCL component. Two independent mouse models of cecal ligation and cecal anastomosis significantly reduced adhesion severity versus Seprafilm, COG133 liquid suspension, and no treatment control. The synergy of physical and chemical methods in a barrier material with proven preclinical studies highlights the value of COG133-loaded PLCL fiber mats in effectively dampening the formation of severe abdominal adhesions.

4.
Bioeng Transl Med ; 8(1): e10335, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36684071

ABSTRACT

Adhesions are dense, fibrous bridges that adjoin tissue surfaces due to uncontrolled inflammation following postoperative mesothelial injury. A widely used adhesion barrier material in Seprafilm often fails to prevent transverse scar tissue deposition because of its poor mechanical properties, rapid degradation profile, and difficulty in precise application. Solution blow spinning (SBS), a polymer fiber deposition technique, allows for the placement of in situ tissue-conforming and tissue-adherent scaffolds with exceptional mechanical properties. While biodegradable polymers such as poly(lactic-co-glycolic acid) (PLGA) have desirable strength, they exhibit bulk biodegradation rates and inflammatory profiles that limit their use as adhesion barriers and result in poor tissue adhesion. Here, viscoelastic poly(lactide-co-caprolactone) (PLCL) is used for its pertinent biodegradation mechanism. Because it degrades via surface erosion, spray deposited PLCL fibers can dissolve new connections formed by inflamed tissue, allowing them to function as an effective, durable, and easy-to-apply adhesion barrier. Degradation kinetics are tuned to match adhesion formation through the design of PLCL blends comprised of highly adhesive "low"-molecular weight (LMW) constituents in a mechanically robust "high"-molecular weight (HMW) matrix. In vitro studies demonstrate that blending LMW PLCL (30% w/v) with HMW PLCL (70% w/v) yields an anti-fibrotic yet tissue-adhesive polymer sealant with a 14-day erosion rate countering adhesion formation. PLCL blends additionally exhibit improved wet tissue adhesion strength (~10 kPa) over a 14-day period versus previously explored biodegradable polymer compositions, such as PLGA. In a mouse cecal ligation model, select PLCL blends significantly reduce abdominal adhesions severity versus no treatment and Seprafilm-treated controls.

5.
J Med Imaging (Bellingham) ; 9(6): 064502, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36466077

ABSTRACT

Purpose: Intraoperative evaluation of bowel perfusion is currently dependent upon subjective assessment. Thus, quantitative and objective methods of bowel viability in intestinal anastomosis are scarce. To address this clinical need, a conditional adversarial network is used to analyze the data from laser speckle contrast imaging (LSCI) paired with a visible-light camera to identify abnormal tissue perfusion regions. Approach: Our vision platform was based on a dual-modality bench-top imaging system with red-green-blue (RGB) and dye-free LSCI channels. Swine model studies were conducted to collect data on bowel mesenteric vascular structures with normal/abnormal microvascular perfusion to construct the control or experimental group. Subsequently, a deep-learning model based on a conditional generative adversarial network (cGAN) was utilized to perform dual-modality image alignment and learn the distribution of normal datasets for training. Thereafter, abnormal datasets were fed into the predictive model for testing. Ischemic bowel regions could be detected by monitoring the erroneous reconstruction from the latent space. The main advantage is that it is unsupervised and does not require subjective manual annotations. Compared with the conventional qualitative LSCI technique, it provides well-defined segmentation results for different levels of ischemia. Results: We demonstrated that our model could accurately segment the ischemic intestine images, with a Dice coefficient and accuracy of 90.77% and 93.06%, respectively, in 2560 RGB/LSCI image pairs. The ground truth was labeled by multiple and independent estimations, combining the surgeons' annotations with fastest gradient descent in suspicious areas of vascular images. The total processing time was 0.05 s for an image size of 256 × 256 . Conclusions: The proposed cGAN can provide pixel-wise and dye-free quantitative analysis of intestinal perfusion, which is an ideal supplement to the traditional LSCI technique. It has potential to help surgeons increase the accuracy of intraoperative diagnosis and improve clinical outcomes of mesenteric ischemia and other gastrointestinal surgeries.

6.
Front Immunol ; 13: 991790, 2022.
Article in English | MEDLINE | ID: mdl-36341364

ABSTRACT

Immunotherapy is a key modality in the treatment of cancer, but many tumors remain immune resistant. The classic mouse model of B16-F10 melanoma is immune resistant even in the face of checkpoint inhibition. Apolipoprotein E (apoE), a known immune suppressant is strikingly elevated in many human tumors, but its role in cancer immunology is not defined. We investigated the role of apoE in the immune micro-environment using a mouse melanoma model. We demonstrate that ApoE is -highly expressed in wild-type B16-F10 melanoma and serum levels progressively increase as tumors grow. The conditioned media from wild type ApoE secreting melanoma cells suppress T-cell activation in vitro while this suppressive effect is absent in conditioned media from ApoE knock out tumor cells. Mechanistically, apoE induces IL-10 secreting dendritic cells and stimulates T-cell apoptosis and arrest partially via the lrp8 receptor. Ablating ApoE in mice inoculated with tumor cells enabled tumor cell rejection and was associated with induction of immune pathway activation and immune cell infiltration. Tumor secreted apoE appears to be a potent immune cell checkpoint and targeting apoE is associated with enhanced tumor immunity in the mouse melanoma model.


Subject(s)
Melanoma, Experimental , Animals , Mice , Humans , Culture Media, Conditioned , Mice, Inbred C57BL , Apolipoproteins E , Apolipoproteins , Tumor Microenvironment
7.
Burns ; 48(8): 1950-1965, 2022 12.
Article in English | MEDLINE | ID: mdl-35151510

ABSTRACT

Autologous skin cell suspensions (ASCS) can treat burns of varying depths with the advantage of reduced donor site wound burden. The current standard primary dressing for ASCS is a nonabsorbant, non-adherent, perforated film (control) which has limited conformability over heterogeneous wound beds and allows for run-off of the ASCS. To address these concerns, a novel spray-on polymer formulation was tested as a potential primary dressing in porcine deep partial thickness (DPT) and full thickness (FT) wounds. It was hypothesized that the polymer would perform as well as control dressing when evaluating wound healing and scarring. DPT or FT wounds were treated with either a spray-on poly(lactic-co-glycolic acid) (PLGA) and poly(lactide-co-caprolactone) (PLCL) formulation or control ASCS dressings. Throughout the experimental time course (to day 50), we found no significant differences between polymer and control wounds in % re-epithelialization, graft-loss, epidermal or dermal thickness, or % dermal cellularity in either model. Pigmentation, erythema, elasticity, and trans-epidermal water loss (TEWL), were not significantly altered between the treatment groups, but differences between healing wounds/scars and un-injured skin were observed. No cytotoxic effect was observed in ASCS incubated with the PLGA and PLCL polymers. These data suggest that the novel spray-on polymer is a viable option as a primary dressing, with improved ease of application and conformation to irregular wounds. Polymer formulation and application technique should be a subject of future research.


Subject(s)
Burns , Swine , Animals , Burns/surgery , Pilot Projects , Skin Transplantation/methods , Polymers/therapeutic use , Wound Healing , Cicatrix
8.
Hawaii J Health Soc Welf ; 79(5 Suppl 1): 19-23, 2020 05 01.
Article in English | MEDLINE | ID: mdl-32490381

ABSTRACT

In the state of Hawai'i, nearly all pediatric surgical care is delivered on the main island of O'ahu at the state's primary tertiary children's hospital. Outpatient clinic visits require patients and families to travel to O'ahu. The direct and opportunity costs of this can be significant. The objective of this study was to characterize potential telehealth candidates to estimate the opportunity for telehealth delivery of outpatient pediatric surgical care. A retrospective chart review including all patients transported from neighbor islands for outpatient consultation with a pediatric surgeon on O'ahu over a 4-year period was performed. Each patient visit was examined to determine if the visit was eligible for telehealth services using stringent criteria. Direct, insurance-based costs of the travel necessary were then determined. Demographic data was used to characterize the patients potentially affected. A total of 1081 neighbor island patients were seen in the pediatric surgery clinic over 4 years. Thirty-one percent of these patients met criteria as candidates for telehealth visits. The majority of patients came from Hawai'i and Maui. Most patients were identified as Native Hawaiian or Asian. The average cost per trip was $112.53 per person, leading to a potential direct cost savings of $37,697 over 4 years. Over 30% of outpatient pediatric surgical encounters met stringent criteria as candidates for telehealth delivery of care. Given the significant number of patients that met our criteria, we believe there is an opportunity for direct, travel-based cost savings with the implementation of telehealth delivery of outpatient pediatric surgical care in Hawai'i.


Subject(s)
Pediatrics/methods , Telemedicine/methods , Ambulatory Care Facilities/organization & administration , Ambulatory Care Facilities/statistics & numerical data , Child , Child, Preschool , Female , Hawaii , Humans , Infant , Male , Postoperative Care/instrumentation , Postoperative Care/methods , Retrospective Studies , Surgical Procedures, Operative/methods , Telemedicine/instrumentation , Telemedicine/trends
9.
J Orthop ; 16(2): 118-122, 2019.
Article in English | MEDLINE | ID: mdl-30723362

ABSTRACT

This study examined early perioperative complications and subsidence following total hip arthroplasty (THA) with a short femoral stem. A retrospective review of 207 consecutive patients (247 hips) having undergone THA via the direct anterior approach produced only six perioperative complications: two intraoperative fractures, three perioperative femur fractures and one dislocation. Subsidence greater than 5 mm was observed in four hips but subsidence did not progress greater than 3 mm at the latest follow-up. Based on these results, cementless THA though the direct anterior approach with a short femoral stem provides a clinical and radiographic advantage while maintaining low complication rates.

SELECTION OF CITATIONS
SEARCH DETAIL
...