Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Vasc Interv Radiol ; 35(7): 979-988.e1, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38537737

ABSTRACT

PURPOSE: To assess the different adjunctive catheter techniques required to achieve complete occlusion of renal arteriovenous malformations (rAVMs) of different angioarchitectural types. MATERIALS AND METHODS: Overall, data on 18 patients with rAVM (Type 1, n = 7; Type 2, n = 2; Type 3, n = 9; mean age, 53.8 years) who underwent 25 procedures between 2011 and 2022 were reviewed. The clinical presentations, endovascular techniques, arteriovenous malformation (AVM) occlusion rate, adverse events (including the incidence of renal infarction), and clinical symptoms and outcomes (including recurrence/increase of AVM) were analyzed according to the Cho-Do angioarchitectural classification. Posttreatment renal infarction was classified as no infarction, small infarction (<12.5%), medium infarction (12.5%-25%), and large infarction (>25%) using contrast-enhanced computed tomography or magnetic resonance imaging. RESULTS: Hematuria and heart failure were presenting symptoms in 10 and 2 patients, respectively. The embolic materials used were as follows: Type 1 rAVM, coils alone or with n-butyl-2-cyanoacrylate (nBCA); Type 2 rAVM, nBCA alone or with coils; and Type 3 rAVMs, nBCA alone. Fourteen patients underwent adjunctive catheter techniques, including flow control with a balloon catheter and multiple microcatheter placement, alone or in combination. Immediate postprocedural angiography revealed complete occlusion in 15 patients (83%) and marked regression of rAVM in 3 (17%). Small asymptomatic renal infarctions were observed in 6 patients with Type 3 rAVMs without any decrease in renal function. No major adverse events were observed. All symptomatic patients experienced symptom resolution. Recurrence/increase of rAVM was not observed during the mean 32-month follow-up period (range, 2-120 months). CONCLUSIONS: Transarterial embolization using adjunctive catheter techniques according to angioarchitectural types can be an effective treatment for rAVMs.


Subject(s)
Arteriovenous Malformations , Embolization, Therapeutic , Renal Artery , Renal Veins , Humans , Middle Aged , Female , Male , Embolization, Therapeutic/adverse effects , Arteriovenous Malformations/therapy , Arteriovenous Malformations/diagnostic imaging , Treatment Outcome , Adult , Retrospective Studies , Aged , Renal Artery/diagnostic imaging , Renal Artery/abnormalities , Renal Veins/diagnostic imaging , Renal Veins/abnormalities , Computed Tomography Angiography , Predictive Value of Tests , Recurrence , Time Factors , Young Adult , Risk Factors , Enbucrilate/administration & dosage , Infarction/diagnostic imaging , Infarction/etiology , Infarction/therapy , Magnetic Resonance Angiography
2.
Article in English | MEDLINE | ID: mdl-38346820

ABSTRACT

OBJECTIVE: The aim of this study was to assess the utility of the combined use of 3D wheel sampling and deep learning-based reconstruction (DLR) for intracranial high-resolution (HR)-time-of-flight (TOF)-magnetic resonance angiography (MRA) at 3 T. METHODS: This prospective study enrolled 20 patients who underwent head MRI at 3 T, including TOF-MRA. We used 3D wheel sampling called "fast 3D" and DLR for HR-TOF-MRA (spatial resolution, 0.39 × 0.59 × 0.5 mm3) in addition to conventional MRA (spatial resolution, 0.39 × 0.89 × 1 mm3). We compared contrast and contrast-to-noise ratio between the blood vessels (basilar artery and anterior cerebral artery) and brain parenchyma, full width at half maximum in the P3 segment of the posterior cerebral artery among 3 protocols. Two board-certified radiologists evaluated noise, contrast, sharpness, artifact, and overall image quality of 3 protocols. RESULTS: The contrast and contrast-to-noise ratio of fast 3D-HR-MRA with DLR are comparable or higher than those of conventional MRA and fast 3D-HR-MRA without DLR. The full width at half maximum was significantly lower in fast 3D-MRA with and without DLR than in conventional MRA (P = 0.006, P < 0.001). In qualitative evaluation, fast 3D-MRA with DLR had significantly higher sharpness and overall image quality than conventional MRA and fast 3D-MRA without DLR (sharpness: P = 0.021, P = 0.001; overall image quality: P = 0.029, P < 0.001). CONCLUSIONS: The combination of 3D wheel sampling and DLR can improve visualization of arteries in intracranial TOF-MRA.

3.
Eur Radiol ; 33(11): 7923-7933, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37284863

ABSTRACT

OBJECTIVES: As a novel follow-up method for intracranial aneurysms treated with stent-assisted coil embolization (SACE), we developed four-dimensional magnetic resonance angiography (MRA) with minimized acoustic noise utilizing ultrashort-echo time (4D mUTE-MRA). We aimed to assess whether 4D mUTE-MRA is useful for the evaluation of intracranial aneurysms treated with SACE. METHODS: This study included 31 consecutive patients with intracranial aneurysm treated with SACE who underwent 4D mUTE-MRA at 3 T and digital subtraction angiography (DSA). For 4D mUTE-MRA, five dynamic MRA images with a spatial resolution of 0.5 × 0.5 × 0.5 mm3 were obtained every 200 ms. Two readers independently reviewed the 4D mUTE-MRA images to evaluate the aneurysm occlusion status (total occlusion, residual neck, and residual aneurysm) and the flow in the stent using a 4-point scale (from 1 [not visible] to 4 [excellent]). The interobserver and intermodality agreement was assessed using κ statistics. RESULTS: On DSA images, 10 aneurysms were classified as total occlusion, 14 as residual neck, and 7 as residual aneurysm. In terms of aneurysm occlusion status, the intermodality and interobserver agreement was excellent (κ = 0.92 and κ = 0.96, respectively). For the flow in the stents on 4D mUTE-MRA, the mean score was significantly higher for single stents than multiple stents (p < .001) and for open-cell type stents than closed-cell type (p < .01). CONCLUSIONS: 4D mUTE-MRA is a useful tool with a high spatial and temporal resolution for the evaluation of intracranial aneurysms treated with SACE. KEY POINTS: • In the evaluation of intracranial aneurysms treated with SACE on 4D mUTE-MRA and DSA, the intermodality and interobserver agreement in aneurysm occlusion status was excellent. • 4D mUTE-MRA shows good to excellent visualization of flow in the stents, especially for cases treated with a single or open-cell stent. • 4D mUTE-MRA can provide hemodynamic information related to embolized aneurysms and the distal arteries to stented parent arteries.


Subject(s)
Embolization, Therapeutic , Intracranial Aneurysm , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Follow-Up Studies , Embolization, Therapeutic/methods , Magnetic Resonance Angiography/methods , Stents , Angiography, Digital Subtraction/methods , Treatment Outcome
4.
Cell Mol Immunol ; 18(6): 1545-1561, 2021 06.
Article in English | MEDLINE | ID: mdl-32457406

ABSTRACT

Monoclonal antibodies (mAbs) are widely utilized as therapeutic drugs for various diseases, such as cancer, autoimmune diseases, and infectious diseases. Using the avian-derived B cell line DT40, we previously developed an antibody display technology, namely, the ADLib system, which rapidly generates antigen-specific mAbs. Here, we report the development of a human version of the ADLib system and showcase the streamlined generation and optimization of functional human mAbs. Tailored libraries were first constructed by replacing endogenous immunoglobulin genes with designed human counterparts. From these libraries, clones producing full-length human IgGs against distinct antigens can be isolated, as exemplified by the selection of antagonistic mAbs. Taking advantage of avian biology, effective affinity maturation was achieved in a straightforward manner by seamless diversification of the parental clones into secondary libraries followed by single-cell sorting, quickly affording mAbs with improved affinities and functionalities. Collectively, we demonstrate that the human ADLib system could serve as an integrative platform with unique diversity for rapid de novo generation and optimization of therapeutic or diagnostic antibody leads. Furthermore, our results suggest that libraries can be constructed by introducing exogenous genes into DT40 cells, indicating that the ADLib system has the potential to be applied for the rapid and effective directed evolution and optimization of proteins in various fields beyond biomedicine.


Subject(s)
Antibodies/metabolism , Antibody Formation , B-Lymphocytes/metabolism , Amino Acid Sequence , Animals , Antibodies/chemistry , Antibodies/genetics , Antibodies, Monoclonal/immunology , Antibodies, Neutralizing/metabolism , Antibody Formation/drug effects , B-Lymphocytes/drug effects , Base Sequence , Cell Line , Chickens , Gene Conversion/drug effects , Gene Dosage , Genetic Variation , Humans , Hydroxamic Acids/pharmacology , Pseudogenes , Tumor Necrosis Factor-alpha/metabolism , Vascular Endothelial Growth Factor A/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...