Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Am Soc Echocardiogr ; 27(8): 880-7, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24891261

ABSTRACT

BACKGROUND: Longitudinal strain (LS) is a quantitative parameter that adds incremental value to wall motion analysis. The aim of this study was to compare the reproducibility of LS derived from Doppler tissue imaging and speckle-tracking between an expert and a novice strain reader during dobutamine stress echocardiography (DSE). METHODS: Forty-one patients (mean age, 65 ± 15 years; mean ejection fraction, 58 ± 11%) underwent DSE per clinical protocol. Global LS derived from speckle-tracking and regional LS derived from both speckle-tracking and Doppler tissue imaging were measured twice by an expert strain reader and also measured twice by a novice strain reader. Intraobserver and interobserver analyses were performed using intraclass correlation coefficients (ICC), Bland-Altman analysis, and absolute difference values (mean ± SD). RESULTS: Global LS measured by the expert strain reader demonstrated high intraobserver measurement reproducibility (rest: ICC = 0.95, absolute difference = 5.5 ± 4.9%; low dose: ICC = 0.96, absolute difference = 5.7 ± 3.7%; peak dose: ICC = 0.87, absolute difference = 11.4 ± 8.4%). Global LS measured by the novice strain reader also demonstrated high intraobserver reproducibility (rest: ICC = 0.97, absolute difference = 4.1 ± 3.4%; low dose: ICC = 0.94, absolute difference = 5.4 ± 5.9%; peak dose: ICC = 0.94, absolute difference = 6.1 ± 4.8%). Global LS also showed high interobserver agreement between the expert and novice readers at all stages of DSE (rest: ICC = 0.90, absolute difference = 8.5 ± 7.5%; low dose: ICC = 0.90, absolute difference = 8.9 ± 7.1%; peak dose: ICC = 0.87, absolute difference = 10.8 ± 8.4%). Of all parameters studied, LS derived from Doppler tissue imaging had relatively low interobserver and intraobserver agreement. CONCLUSIONS: Global LS is highly reproducible during all stages of DSE. This variable is a potentially reliable and reproducible measure of myocardial deformation.


Subject(s)
Echocardiography, Doppler/methods , Echocardiography, Stress/methods , Heart Ventricles/physiopathology , Myocardial Ischemia/physiopathology , Ventricular Function, Left/physiology , Aged , Female , Follow-Up Studies , Glucosinolates , Heart Ventricles/diagnostic imaging , Humans , Male , Myocardial Ischemia/diagnostic imaging , Prospective Studies , ROC Curve , Reproducibility of Results , Stroke Volume
SELECTION OF CITATIONS
SEARCH DETAIL
...