Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Front Oncol ; 14: 1333642, 2024.
Article in English | MEDLINE | ID: mdl-38939330

ABSTRACT

Purpose/Objectives: ZAP-X, a novel and dedicated radiosurgery (SRS) system, has recently emerged, while CyberKnife has solidified its position as a versatile solution for SRS and stereotactic body radiation therapy over the past two decades. This study aims to compare the dosimetric performance and delivery efficiency of ZAP-X and CyberKnife in treating brain metastases of varying target sizes, employing circular collimation. Methods and materials: Twenty-three patients, encompassing a total of 47 brain metastases, were included in the creation of comparative plans of ZAP-X and CyberKnife for analysis. The comparative plans were generated to achieve identical prescription doses for the targets, while adhering to the same dose constraints for organs at risk (OAR). The prescription isodose percentage was optimized within the range of 97-100% for each plan to ensure effective target-volume coverage. To assess plan quality, indices such as conformity, homogeneity, and gradient (CI, HI, and GI) were computed, along with the reporting of total brain volumes receiving 12Gy and 10Gy. Estimated treatment time and monitor units (MUs) were compared between the two modalities in evaluating delivery efficiency. Results: Overall, CyberKnife achieved better CI and HI, while ZAP-X exhibited better GI and a smaller irradiated volume for the normal brain. The superiority of CyberKnife's plan conformity was more pronounced for target size less than 1 cc and greater than 10 cc. Conversely, the advantage of ZAP-X's plan dose gradient was more notable for target sizes under 10 cc. The homogeneity of ZAP-X plans, employing multiple isocenters, displayed a strong correlation with the target's shape and the planner's experience in placing isocenters. Generally, the estimated treatment time was similar between the two modalities, and the delivery efficiency was significantly impacted by the chosen collimation sizes for both modalities. Conclusion: This study demonstrates that, within the range of target sizes within the patient cohort, plans generated by ZAP-X and CyberKnife exhibit comparable plan quality and delivery efficiency. At present, with the current platform of the two modalities, CyberKnife outperforms ZAP-X in terms of conformity and homogeneity, while ZAP-X tends to produce plans with a more rapid dose falloff.

2.
Front Oncol ; 7: 5, 2017.
Article in English | MEDLINE | ID: mdl-28224113

ABSTRACT

BACKGROUND: Recent data suggest that intensity-modulated radiation therapy (IMRT) plus brachytherapy boost for unfavorable prostate cancer provides improved biochemical relapse-free survival over IMRT alone. Stereotactic body radiation therapy (SBRT) may be a less invasive alternative to brachytherapy boost. Here, we report the 3-year gastrointestinal (GI) and genitourinary (GU) toxicities of IMRT plus SBRT boost. MATERIALS AND METHODS: Between March 2008 and September 2012, patients with prostate cancer were treated with robotic SBRT (19.5 Gy in three fractions) followed by fiducial-guided IMRT (45-50.4 Gy) on an institutional protocol. Toxicity was prospectively graded using the common terminology criteria for adverse events version 4.0 (CTCAEv.4) at the start of and at 1- to 6-month intervals after therapy. Rectal telangiectasias were graded using the Vienna Rectoscopy Score (VRS). RESULTS: At a median follow-up of 4.2 years (2.4-7.5), 108 patients (4 low-, 45 intermediate-, and 59 high-risk) with a median age of 74 years (55-92) were treated with SBRT plus IMRT, with 8% on anticoagulation and an additional 48% on antiplatelet therapy at the start of therapy. The cumulative incidence of late ≥grade 2 GI toxicity was 12%. Of these, 7% were due to late rectal bleeding, with six patients requiring up to two coagulation procedures. One patient with rectal telangiectasias was treated with hyperbaric oxygen (grade 3 toxicity). No rectal fistulas or stenoses were observed. Ten patients had multiple non-confluent telangiectasias (VRS grade 2), and three patients had multiple confluent telangiectasias (VRS grade 3). The cumulative incidence of late grade 3 GU toxicity was 6%. Most late toxicities were due to hematuria requiring bladder fulguration. There were no late ≥grade 4 GU toxicities. CONCLUSION: Rates of clinically significant GI and GU toxicities are modest following IMRT plus SBRT boost. Future studies should compare cancer control, quality of life, and toxicity with other treatment modalities for patients with high-risk prostate cancer.

3.
Front Oncol ; 6: 114, 2016.
Article in English | MEDLINE | ID: mdl-27200300

ABSTRACT

PURPOSE/OBJECTIVES: Stereotactic body radiation therapy (SBRT) is emerging as a minimally invasive alternative to brachytherapy to deliver highly conformal, dose--escalated radiation therapy (RT) to the prostate. SBRT alone may not adequately cover the tumor extensions outside the prostate commonly seen in unfavorable prostate cancer. External beam radiation therapy (EBRT) with high dose rate brachytherapy boost is a proven effective therapy for unfavorable prostate cancer. This study reports on early prostate-specific antigen and prostate cancer-specific quality of life (QOL) outcomes in a cohort of unfavorable patients treated with intensity-modulated radiation therapy (IMRT) and SBRT boost. MATERIALS/METHODS: Prostate cancer patients treated with SBRT (19.5 Gy in three fractions) followed by fiducial-guided IMRT (45-50.4 Gy) from March 2008 to September 2012 were included in this retrospective review of prospectively collected data. Biochemical failure was assessed using the Phoenix definition. Patients completed the expanded prostate cancer index composite (EPIC)-26 at baseline, 1 month after the completion of RT, every 3 months for the first year, then every 6 months for a minimum of 2 years. RESULTS: One hundred eight patients (4 low-, 45 intermediate-, and 59 high-risk) with median age of 74 years completed treatment, with median follow-up of 4.4 years. Sixty-four percent of the patients received androgen deprivation therapy prior to the initiation of RT. The 3-year actuarial biochemical control rates were 100 and 89.8% for intermediate- and high-risk patients, respectively. At the initiation of RT, 9 and 5% of men felt their urinary and bowel function was a moderate to big problem, respectively. Mean EPIC urinary and bowel function and bother scores exhibited transient declines, with subsequent return to near baseline. At 2 years posttreatment, 13.7 and 5% of men felt their urinary and bowel function was a moderate to big problem, respectively. CONCLUSION: At 3-year follow-up, biochemical control was favorable. Acute urinary and bowel symptoms were comparable to conventionally fractionated IMRT and brachytherapy. Patients recovered to near their baseline urinary and bowel function by 2 years posttreatment. A combination of IMRT with SBRT boost is well tolerated with minimal impact on prostate cancer-specific QOL.

4.
Radiat Oncol ; 10: 15, 2015 Jan 13.
Article in English | MEDLINE | ID: mdl-25582217

ABSTRACT

BACKGROUND: To examine factors associated with the use of radiation therapy (RT) at the end of life in patients with breast, prostate, or colorectal cancer. METHODS: Using data from the Surveillance, Epidemiology, and End Results (SEER) - Medicare database, patients were over age 65 and diagnosed between January 1, 2004 and December 31, 2011 with any stage of cancer when the cause of death, as defined by SEER, was cancer; or with stage 4 cancer, who died of any cause. We employed multiple logistic regression models to identify patient and health systems factors associated with palliative radiation use. RESULTS: 50% of patients received RT in the last 6 months of life. RT was used less frequently in older patients and in non-Hispanic white patients. Similar patterns were observed in the last 14 days of life. Chemotherapy use in the last 6 months of life was strongly correlated with receiving RT in the last 6 months (OR 2.72, 95% CI: 2.59-2.88) and last 14 days of life (OR 1.55, 95% CI: 1.40-1.66). Patients receiving RT accrued more emergency department visits, radiographic exams and physician visits (all comparisons p < 0.0001). CONCLUSIONS: Among patients with breast, colorectal, and prostate cancer, palliative RT use was common. End-of-life RT correlated with end-of-life chemotherapy use, including in the last 14 days of life, when treatment may cause increased treatment burden without improved quality of life. Research is needed optimize the role and timing of RT in palliative care.


Subject(s)
Breast Neoplasms/radiotherapy , Colorectal Neoplasms/radiotherapy , Palliative Care , Prostatic Neoplasms/radiotherapy , Quality of Life , Radiotherapy/statistics & numerical data , Terminal Care , Breast Neoplasms/epidemiology , Breast Neoplasms/mortality , Colorectal Neoplasms/epidemiology , Colorectal Neoplasms/mortality , Female , Humans , Male , Medicare , Prognosis , Prostatic Neoplasms/epidemiology , Prostatic Neoplasms/mortality , SEER Program , Survival Rate , United States/epidemiology
5.
Technol Cancer Res Treat ; 9(5): 453-62, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20815416

ABSTRACT

Clinical data suggest that large radiation fractions are biologically superior to smaller fraction sizes in prostate cancer radiotherapy. The CyberKnife is an appealing delivery system for hypofractionated radiosurgery due to its ability to deliver highly conformal radiation and to track and adjust for prostate motion in real-time. We report our early experience using the CyberKnife to deliver a hypofractionated stereotactic body radiation therapy (SBRT) boost to patients with intermediate- to high-risk prostate cancer. Twenty-four patients were treated with hypofractionated SBRT and supplemental external radiation therapy plus or minus androgen deprivation therapy (ADT). Patients were treated with SBRT to a dose of 19.5 Gy in 3 fractions followed by intensity modulated radiation therapy (IMRT) to a dose of 50.4 Gy in 28 fractions. Quality of life data were collected with American Urological Association (AUA) symptom score and Expanded Prostate Cancer Index Composite (EPIC) questionnaires before and after treatment. PSA responses were monitored; acute urinary and rectal toxicities were assessed using Common Toxicity Criteria (CTC) v3. All 24 patients completed the planned treatment with an average follow-up of 9.3 months. For patients who did not receive ADT, the median pre-treatment PSA was 10.6 ng/ml and decreased in all patients to a median of 1.5 ng/ml by 6 months post-treatment. Acute effects associated with treatment included Grade 2 urinary and gastrointestinal toxicity but no patient experienced acute Grade 3 or greater toxicity. AUA and EPIC scores returned to baseline by six months post-treatment. Hypofractionated SBRT combined with IMRT offers radiobiological benefits of a large fraction boost for dose escalation and is a well tolerated treatment option for men with intermediate- to high-risk prostate cancer. Early results are encouraging with biochemical response and acceptable toxicity. These data provide a basis for the design of a phase II clinical trial.


Subject(s)
Prostatic Neoplasms/therapy , Radiosurgery/methods , Radiotherapy, Intensity-Modulated/methods , Aged , Aged, 80 and over , Combined Modality Therapy , Follow-Up Studies , Humans , Male , Middle Aged , Pilot Projects
SELECTION OF CITATIONS
SEARCH DETAIL
...