Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Publication year range
1.
J Acoust Soc Am ; 131(3): EL275-81, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22423820

ABSTRACT

The accuracy of scattered Rayleigh waves estimated using an interferometric method is investigated. Summing the cross correlations of the wave fields measured all around the scatterers yields the Green's function between two excitation points. This accounts for the direct wave and the scattered field (coda). The correlations themselves provide insights into the location of the scatterers, as well as which scatterer is responsible for particular parts of the coda. Furthermore, these measurements confirm a constant-time arrival in the correlations, not part of the Green's function, but which has previously been derived as a result of the generalized optical theorem.

2.
J Acoust Soc Am ; 130(6): 3674-90, 2011 Dec.
Article in English | MEDLINE | ID: mdl-22225024

ABSTRACT

This paper investigates the reconstruction of elastic Green's function from the cross-correlation of waves excited by random noise in the context of scattering theory. Using a general operator equation-the resolvent formula-Green's function reconstruction is established when the noise sources satisfy an equipartition condition. In an inhomogeneous medium, the operator formalism leads to generalized forms of optical theorem involving the off-shell T-matrix of elastic waves, which describes scattering in the near-field. The role of temporal absorption in the formulation of the theorem is discussed. Previously established symmetry and reciprocity relations involving the on-shell T-matrix are recovered in the usual far-field and infinitesimal absorption limits. The theory is applied to a point scattering model for elastic waves. The T-matrix of the point scatterer incorporating all recurrent scattering loops is obtained by a regularization procedure. The physical significance of the point scatterer is discussed. In particular this model satisfies the off-shell version of the generalized optical theorem. The link between equipartition and Green's function reconstruction in a scattering medium is discussed.

3.
Article in English | MEDLINE | ID: mdl-19574154

ABSTRACT

The stresses at transducer contacts were estimated from accurate particle velocity measurements by using a laser Doppler vibrometer (LDV). We then evaluated the performance of LDV for ultrasonic waveform measurements in physical model experiments that are employed for modeling seismic observations. For such experiments, the characteristics of the source and detector should be exactly known. Disc-shaped compression and shear-mode piezoelectric transducers were attached on a flat surface of a steel semicircular column, and ultrasonic waves were excited by single-shot sine waves with 0.25, 0.5, and 1 MHz frequencies. Radial and transverse components were measured by LDV at a distance of 150 mm from the source. The maximum amplitudes of waves with respect to radiation angle give a radiation pattern of a transducer. Each observed radiation pattern was fitted to the calculated radiation pattern by assuming a harmonically oscillating stress distributed uniformly on a flat circular area. The observed radiation patterns show fairly good agreement with the calculated radiation patterns for both radial and transverse components when the source frequencies are 0.25 and 0.5 MHz. Because the best-fit stress values were independently estimated from the radial and the transverse radiation patterns, the 2 stress values should be equal for each source and frequency. The discrepancy between the estimated radial and transverse stress values becomes larger as the source frequency increases. Provided that coincidence of the 2 stress values indicates the validity of waveform measurements, the results suggest that LDV is applicable for measuring the 3-D particle-velocity at frequencies up to 0.5 MHz.

4.
Tohoku J Exp Med ; 215(1): 23-32, 2008 May.
Article in English | MEDLINE | ID: mdl-18509232

ABSTRACT

Placental/umbilical cord blood (CB) contains nucleated cells and hematopoietic stem/progenitor cells (CD34(+) cells). However it is difficult to predict the number of nucleated/CD34(+) cells in each CB before cell processing. Despite many previous studies from institutes affiliated with CB banks in metropolitan areas, little information is available regarding the characteristics of CB units from other medical facilities. The purpose of the present study was to analyze the maternal/neonatal factors on the yield of cells in CB units. A total of 176 CB units were obtained from single-birth and normal vaginal deliveries. Mononuclear low-density (LD) cells were separated using Ficoll-Paque within 24 hrs after CB collection and then processed for the purification of CD34(+) cells. A multiple linear regression analysis was performed to assess the correlations between the yield of cells and maternal/neonatal factors including maternal age, gravid status, duration of labor, gestational age, neonatal height and weight, cord length, and meconium in the amniotic fluid. The total LD cells per CB unit had a weak positive correlation with the maternal age of primigravidae. The total LD cells per CB unit from the primigravidae aged > or = 25 were significantly higher than those from the primigravidae aged < or = 24. The total CD34(+) cells per CB unit from the 1-gravidae were significantly higher than those from the 2-gravidae and 3-gravidae, respectively among all donors. These results indicate that the CB units from the primigravidae aged > or = 25 are more likely to contain higher yield of LD/CD34(+) cells.


Subject(s)
Antigens, CD34/biosynthesis , Fetal Blood/cytology , Fetal Blood/metabolism , Hematopoietic Stem Cells/metabolism , Adolescent , Adult , Blood Cell Count , Female , Humans , Infant, Newborn , Leukocyte Count , Middle Aged
5.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 60(11): 1519-25, 2004 Nov.
Article in Japanese | MEDLINE | ID: mdl-15568003

ABSTRACT

PURPOSE: To evaluate the ability of periodically rotated overlapping parallel lines with enhanced reconstruction diffusion-weighted imaging (PROPELLER DWI) to distinguish between vessel occlusion and slow flow. MATERIALS AND METHODS: Using a flow phantom with various velocities (1.37 to 11.1 cm/s), the signal-intensity ratios of the phantom, with the intensity of no flow as baseline, were measured using the following imaging sequences: PROPELLER DWI, spin-echo T1-weighted imaging (SE T1WI), fast-spin-echo T2-weighted imaging (FSE T2WI), two-dimensional phase-contrast imaging (2D PC), and two-dimensional time-of-flight imaging (2D TOF). The b-factor of PROPELLER DWI was varied from 0 to 1000 s/mm(2). The velocity encoding of 2D PC was varied from 2 to 30 cm/s. RESULTS: At the lowest flow velocity (1.37 cm/s) , the signal-intensity ratio was 0.0075 for PROPELLER DWI (b-factor=1000 s/mm(2)), 1.8 for SE T1WI, 0.67 for FSE T2WI, 11 for 2D PC (velocity encoding=2 cm/s), and 1.4 for 2D TOF. The signal-intensity ratio was smallest for PROPELLER DWI, even when the reciprocals of the signal-intensity ratio of 2D PC or 2D TOF were considered. CONCLUSION: The results indicate that PROPELLER DWI provides the best signal intensity-ratio between vessel occlusion and slow flow. Although DWI with single-shot echo-planar imaging (EPI) or multi-shot EPI may have similarly high sensitivity for slow flow, these sequences do not have high spatial resolution or robustness to susceptibility artifacts. PROPELLER DWI would be a better choice for distinguishing between occluded and low-velocity arteries in the skull base or parasellar regions.


Subject(s)
Cerebrovascular Circulation/physiology , Cerebrovascular Disorders/physiopathology , Diffusion Magnetic Resonance Imaging/methods , Echo-Planar Imaging/methods , Phantoms, Imaging , Blood Flow Velocity , Cerebrovascular Disorders/diagnosis , Diagnosis, Differential , Image Processing, Computer-Assisted/methods
6.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 60(11): 1585-91, 2004 Nov.
Article in Japanese | MEDLINE | ID: mdl-15568011

ABSTRACT

As the PROPELLER sequence is a combination of the radial scan and fast-spin-echo (FSE) sequence, it can be considered an FSE sequence with a motion correlation. However, there are some differences between PROPELLER and FSE owing to differences in k-space trajectory. We clarified the imaging characteristics of PROPELLER T2-weighted imaging (T2WI) for different parameters in comparison with usual FSE T2WI. When the same parameters were used, PROPELLER T2WI showed a higher signal-to-noise ratio (SNR) and lower spatial resolution than usual FSE. Effective echo time (TE) changed with different echo train lengths (ETL) or different bandwidths on PROPELLER, and imaging contrast changed accordingly to be more effective.


Subject(s)
Artifacts , Diffusion Magnetic Resonance Imaging/methods , Diffusion Magnetic Resonance Imaging/instrumentation , Phantoms, Imaging
7.
J Contam Hydrol ; 68(1-2): 23-37, 2004 Jan.
Article in English | MEDLINE | ID: mdl-14698869

ABSTRACT

To quantify the effects of temperature on the diffusivity of deuterated water (HDO) in compacted sodium bentonite, through-diffusion experiments were conducted at elevated temperatures ranging from 298 to 333 K. Kunipia F (Na-montmorillonite content>98 wt.%; Kunimine Industries) was compacted to a dry density of 0.9 or 1.35 Mg/m(3). As montmorillonite particles were oriented perpendicular to the direction of compaction, the anisotropy of diffusivity was investigated both parallel and normal to the preferred orientation of the montmorillonite. The effective diffusion coefficient D(e) of HDO was larger when the diffusional direction was parallel as opposed to normal to the preferred orientation for both dry densities. The magnitude of D(e) and the anisotropy for HDO were in good accordance with previously reported results for tritiated water at room temperature. Activation energies of D(e) were isotropic and increased with increasing dry density over the range of 19-25 kJ/mol. This relationship was considered to be due to both pore structure development and the high activation energy of water near the montmorillonite surface.


Subject(s)
Bentonite/analysis , Deuterium/analysis , Water/chemistry , Anisotropy , Bentonite/chemistry , Deuterium/chemistry , Diffusion , Temperature
8.
J Contam Hydrol ; 61(1-4): 313-28, 2003 Mar.
Article in English | MEDLINE | ID: mdl-12598113

ABSTRACT

Mechanistic model calculations for the migration of Cs, Ra, Am and Pb in compacted bentonite have been carried out to evaluate sensitivities with respect to different parameter variations. A surface chemical speciation/electric double layer model is used to calculate: (i) porewater composition and radionuclide speciation in solution and at the bentonite surface, yielding the distribution of mobile and sorbed species and (ii) interaction of diffusing species with negatively charged pore walls to obtain diffusion parameters. The basic scenario considers the interaction of compacted bentonite with a fresh-type groundwater; variations include the presence of bentonite impurities and saline groundwater. It is shown that these scenarios result in significant variations of porewater composition that affect migration via three mechanisms that can partly compensate each other: (1) effects on sorption through radionuclide complexation in solution, and competition of major cations for surface sites; (2) changes in radionuclide solution speciation leading to different diffusing species under different conditions; (3) effects on diffusion through changes in the electric double layer properties of the clay pores as a function of ionic strength.


Subject(s)
Bentonite/chemistry , Models, Theoretical , Radioactive Waste , Radioisotopes , Aluminum Silicates , Clay , Diffusion , Electricity , Porosity
9.
Bull. W.H.O. (Print) ; 26(5): 675-681, 1962.
Article in English | WHO IRIS | ID: who-267600
SELECTION OF CITATIONS
SEARCH DETAIL
...