Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 254
Filter
1.
Am J Otolaryngol ; 45(4): 104297, 2024.
Article in English | MEDLINE | ID: mdl-38692072

ABSTRACT

IMPORTANCE: The symptoms of primary hyperparathyroidism are often subtle, such as fatigue, mood changes, and sleep disturbances. After parathyroidectomy, patients often report improvement in sleep and mood; however, objective data supporting these improvements is lacking. OBJECTIVE: This prospective study uses standard measures to objectively and subjectively assess sleep in patients with primary hyperparathyroidism before and after parathyroidectomy. DESIGN: A longitudinal prospective study was conducted over three one-week-long periods: pre-parathyroidectomy, 1-week post-parathyroidectomy, and three months post-parathyroidectomy. During each time point, patients wore an actigraphy device, recorded a sleep diary, and completed the Pittsburgh Sleep Quality Index (PSQI), Insomnia Severity Index (ISI), and Depression Anxiety Stress Scale (DASS). Statistical analysis was performed using repeated measures models to compare the average measures among the three time points and test for trends over time. SETTING: Single institution, tertiary care center. PARTICIPANTS: Patients with primary hyperparathyroidism from ages 18 to 89 years old. EXPOSURE: Parathyroidectomy between September 2020 and January 2024. MAIN OUTCOMES AND MEASURES: Actigraphy data, consensus sleep diary, Pittsburgh Sleep Quality Index (PSQI), Insomnia Severity Index (ISI), Depression Anxiety Stress Scales - 21 Items (DASS). RESULTS: Thirty-six patients were enrolled, and 34 patients completed the study. Actigraphy data showed a significant negative trend in average sleep latency (p = 0.045) and average time in bed (p = 0.046). Sleep diary data showed additional differences in the number of awakenings (p = 0.002), wake after sleep onset (p < 0.001), sleep quality (p < 0.001), and sleep efficiency (p = 0.02) among the three time points and/or as a significant negative trend. PSQI and ISI scores were significantly different among the three time points (p = 0.002 and p < 0.001, respectively) and also declined significantly over time (p = 0.008 and p = 0.007, respectively). DASS depression, anxiety, and stress scores were significantly different among the three time points (p < 0.001, p = 0.01, and p < 0.001, respectively), and stress also declined significantly over time (p = 0.005). CONCLUSION AND RELEVANCE: This study represents the most extensive prospective study demonstrating objective and subjective sleep and mood improvement in patients with primary hyperparathyroidism after parathyroidectomy.


Subject(s)
Actigraphy , Hyperparathyroidism, Primary , Parathyroidectomy , Humans , Hyperparathyroidism, Primary/surgery , Hyperparathyroidism, Primary/complications , Hyperparathyroidism, Primary/psychology , Middle Aged , Male , Female , Prospective Studies , Aged , Adult , Longitudinal Studies , Aged, 80 and over , Sleep Quality , Young Adult , Adolescent , Depression/etiology , Treatment Outcome , Sleep/physiology , Severity of Illness Index , Sleep Initiation and Maintenance Disorders/etiology
2.
RSC Adv ; 14(9): 6190-6198, 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38375014

ABSTRACT

Semitransparent perovskite solar cells (STPSCs) have excellent potential for widespread application as building integrated photovoltaics. Widespread application of STPSCs could result in decreased CO2 footprints for buildings. Unfortunately, STPSCs tend to have poor aesthetic qualities (being usually red-brown in color) and low stability. Building on our previous work, here we use new poly(N-isopropylacrylamide) microgels (PNP MGs) to provide highly ordered non-close packed arrays within perovskite films that reflect some of the incident light to provide structural color to STPSCs. (MGs are swellable crosslinked polymer colloid particles.) We introduce PNP MGs into two different perovskites and achieve a wide gamut of reflected color and iridescence from the perovskite films. Devices containing the MGs have average visible transparency (AVT) values of greater than 25%. The best PCE for a MG-containing STPSC is 10.60% compared to 9.14% for the MG-free control. The MGs not only introduce structural color to the STPSCs but increase the PCE and stability. Equations are provided that enable the reflected color to be predicted from the formulation used to deposit the films. Our work shows that the self-ordering tendency of PNP MGs gives a viable new method for introducing structural color into STPSCs. Because our one-step method for introducing structural color into STPSCs is general, does not introduce any additional processing steps and is scalable whilst also improving device stability, this study may bring deployment of STPSCs closer.

3.
BMC Gastroenterol ; 24(1): 44, 2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38262960

ABSTRACT

BACKGROUND: High quality endoscopy is key for detecting and removing precursor lesions to colorectal cancer (CRC). Adenoma detection rates (ADRs) measure endoscopist performance. Improving other components of examinations could increase adenoma detection. AIMS: To investigate how endoscopist performance at flexible sigmoidoscopy (FS) affects adenoma detection and CRC incidence. METHODS: Among 34,139 participants receiving FS screening by the main endoscopist at one of 13 centres in the UK FS Screening Trial, median follow-up was 17 years. Factors examined included family history of CRC, bowel preparation quality, insertion and withdrawal time, bowel segment reached, patient pain and ADR. Odds ratios (OR) for distal adenoma detection were estimated by logistic regression. Hazard ratios (HR) for distal CRC incidence were estimated by Cox regression. RESULTS: At screening, 4,104 participants had distal adenomas detected and 168 participants developed distal CRC during follow-up. In multivariable models, a family history of CRC (yes vs. no: OR 1.40, 95%CI 1.21-1.62), good or adequate bowel preparation quality (vs. excellent: OR 0.84, 95%CI 0.74-0.95; OR 0.56, 95%CI 0.49-0.65, respectively) and longer insertion and withdrawal times (≥ 4.00 vs. < 2.00 min: OR 1.96, 95%CI 1.68-2.29; OR 32.79, 95%CI 28.22-38.11, respectively) were associated with adenoma detection. Being screened by endoscopists with low or intermediate ADRs, compared to high ADRs, was positively associated with CRC incidence (multivariable: HR 4.71, 95%CI 2.65-8.38; HR 2.16, 95%CI 1.22-3.81, respectively). CONCLUSIONS: Bowel preparation quality and longer insertion and withdrawal time are key for improving distal adenoma detection. Higher ADRs were associated with a lower risk of distal CRC.


Subject(s)
Adenoma , Colorectal Neoplasms , Humans , Incidence , Odds Ratio , Pain , Clinical Trials as Topic , Multicenter Studies as Topic
4.
Endoscopy ; 55(12): 1152, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38016461
6.
Biomacromolecules ; 24(5): 2173-2183, 2023 05 08.
Article in English | MEDLINE | ID: mdl-37026759

ABSTRACT

Injectable hydrogels offer great potential to augment damaged or degenerated soft tissues. A key criterion for such gels is that their modulus is as close as possible to that of the target tissue. The majority of synthetic hydrogels have used low molecular weight polymer chains which may cause problems if they diffuse away from the injection site and/or increase the local osmotic pressure. We previously introduced a different approach of injecting preformed ultra-high molecular weight pH-responsive microgels (MGs) that interlink to form hydrogels. MGs are crosslinked polymer colloid particles that swell when the pH approaches the particle pKa. These colloidal hydrogels are termed doubly crosslinked microgels (DX MGs). The gel moduli of previous DX MGs were much greater than that reported for human nucleus pulposus (NP) tissue of the spinal intervertebral disk. Here, we replace some of the pH-responsive poly(ethyl acrylate-co-methacrylic acid) (PEA-MAA) MGs with hydrophilic non-ionic MGs based on poly(N-vinylformamide) (NVF). We investigate the morphology and mechanical properties of these new injectable composite DX MGs and show that the mechanical properties can be tuned by systematically varying the NVF MG content. Using this approach, the gel moduli close to that for NP tissue are achieved. These injectable new pH-responsive gels exhibit low cytotoxicity. Our work provides a potential new system for minimally invasive intervertebral disk augmentation.


Subject(s)
Hydrogels , Microgels , Humans , Polymers/chemistry , Hydrogen-Ion Concentration
7.
BMJ Open Gastroenterol ; 10(1)2023 03.
Article in English | MEDLINE | ID: mdl-36944438

ABSTRACT

BACKGROUND: Poor bowel preparation is the leading cause of failed colonoscopies and increases costs significantly. Several, split preparation, 2 day regimens are available and recently, Plenvu, a low-volume preparation which can be given on 1 day has been introduced. AIMS: Assess efficacy and tolerability of commonly used purgative regimens including Plenvu. METHOD: In this service evaluation, patients undergoing screening colonoscopy at St Mark's Hospital, London (February 2020-December 2021) were provided Plenvu (1 or 2 days), Moviprep (2 days) or Senna & Citramag (2 days).Boston Bowel Preparation Scale (BBPS) score, fluid volumes and procedure times were recorded. A patient experience questionnaire evaluated taste, volume acceptability, completion and side effects. RESULTS: 563 patients were invited to participate and 553 included: 218 Moviprep 2 days, 108 Senna & Citramag 2 days, 152 Plenvu 2 days and 75 Plenvu 1 day.BBPS scores were higher with Plenvu 1 and 2 days vs Senna & Citramag (p=0.003 and 0.002, respectively) and vs Moviprep (p=0.003 and 0.001, respectively). No other significant pairwise BBPS differences and no difference in preparation adequacy was seen between the groups.Patients rated taste as most pleasant with Senna & Citramag and this achieved significance versus Plenvu 1 day and 2 days (p=0.002 and p<0.001, respectively) and versus Moviprep (p=0.04). CONCLUSION: BBPS score was higher for 1 day and 2 days Plenvu versus both Senna & Citramag and Moviprep. Taste was not highly rated for Plenvu but it appears to offer effective cleansing even when given as a same day preparation.


Subject(s)
Cathartics , Colonoscopy , Polyethylene Glycols , Humans , Cathartics/administration & dosage , Cathartics/adverse effects , Cathartics/therapeutic use , Colonoscopy/methods , Polyethylene Glycols/administration & dosage , Polyethylene Glycols/adverse effects , Polyethylene Glycols/therapeutic use , Senna Extract/administration & dosage , Senna Extract/adverse effects , Senna Extract/therapeutic use , Surveys and Questionnaires , Treatment Outcome
8.
Gastrointest Endosc ; 98(1): 73-81.e1, 2023 07.
Article in English | MEDLINE | ID: mdl-36739996

ABSTRACT

BACKGROUND AND AIMS: Advances in endoscopic technology, such as narrow-band imaging and high-definition colonoscopes, offer the potential for optical diagnosis (OD) with a "resect and discard" (RD) strategy for diminutive (≤5 mm) and small (6-9 mm) colorectal polyps. This could help alleviate the huge cost and time burden required for histopathology. The aim of this study was to conduct an economic analysis of an RD strategy within the English Bowel Cancer Screening Programme (BCSP). METHODS: A decision tree was designed to compare an RD strategy with standard histopathology for patients included in the DISCARD3 study (Detect InSpect ChAracterise Resect and Discard 3) and was extrapolated to a national BCSP patient cohort. RESULTS: Of the 525 patients in the DISCARD3 study, 354 were assessed for surveillance intervals (after excluding cases with colorectal cancer and at least 1 polyp >10 mm). Of 354 patients, 269 had polyps, of which 182 had only diminutive polyps, 77 had both small and diminutive polyps, and 10 had only small polyps. Surveillance interval concordance was 97.9% in patients with at least 1 diminutive polyp and 98.7% in patients with at least 1 diminutive or small polyp. In DISCARD3, an RD approach was found to reduce overall direct healthcare costs by $44,285.63 (-72.3%) for patients with diminutive polyps or by $66,129.13 (-75.0%) for patients with diminutive or small polyps. When extrapolated to the entire English BCSP, the annual savings were almost $3 million for patients with diminutive polyps or $4.3 million for patients with diminutive or small polyps, after adjusting for the costs of an OD quality assurance process. CONCLUSIONS: OD with an RD strategy for diminutive and small polyps during BCSP colonoscopy would offer substantial cost savings without adversely affecting surveillance interval concordance.


Subject(s)
Colonic Polyps , Colorectal Neoplasms , Humans , Colonic Polyps/diagnostic imaging , Colonic Polyps/surgery , Early Detection of Cancer/methods , Colonoscopy/methods , Colorectal Neoplasms/diagnosis , Colorectal Neoplasms/surgery , Colorectal Neoplasms/pathology , Narrow Band Imaging
9.
J Pers Med ; 13(2)2023 Jan 19.
Article in English | MEDLINE | ID: mdl-36836407

ABSTRACT

Data on current colorectal cancer screening practices in Iraq are limited. This study aimed to better understand the current colorectal cancer screening practice and perceived barriers. The project also aimed to use UK expertise to introduce Bowel Cancer Screening Programme (BCSP) in Basra, Iraq. The study consisted of two parts: A pre-visit online survey of clinicians to test the project's feasibility. A public survey was conducted to understand and gauge the general knowledge and perceived barriers to having colorectal cancer screening. The second phase included a short visit to Basra and the delivery of a multidisciplinary meeting for bowel screening colonoscopists. Fifty healthcare providers completed the survey. Basra has no established bowel cancer screening programme, let alone the country. Opportunistic colonoscopy surveillance is done on an ad hoc base. A total of 350 individuals completed the public survey. The survey showed that more than 50% of participants were not familiar with the concept of a BCSP and less than 25% were aware of "red flag" symptoms of bowel cancer. The short visit to Basra included a roundtable discussion and delivered a training workshop for screening colonoscopists using UK training materials in conjunction with the Iraqi Medical Association. Feedback from the course was extremely positive. Several potential barriers were identified to participate in BCSP. The study highlighted potential barriers, including a lack of public awareness and insufficient training resources to be addressed in future screening programmes. The study has identified several potential areas for future collaboration to support the development of a BCSP centre in Basra.

10.
Gastrointest Endosc ; 97(1): 78-88, 2023 01.
Article in English | MEDLINE | ID: mdl-36029884

ABSTRACT

BACKGROUND AND AIMS: Developments in image-enhancing endoscopy and polyp classification systems have led to a number of gastroenterology societies endorsing an optical diagnosis (OD) approach for small polyps at colonoscopy. In this study we performed a root-cause analysis of ODs to determine the most likely causes of OD error. METHODS: As part of a prospective feasibility study, DISCARD3 (Detect InSpect ChAracterise Resect and Discard 3), evaluating implementation and quality assurance of a "resect and discard" strategy for consecutive small polyps <10 mm, a root-cause analysis of 184 cases of high-confidence OD error was performed. In all cases, histopathology underwent a second blinded review and, where discrepancy persisted, further review with deeper levels. RESULTS: After a root-cause analysis, 133 of 184 true OD errors were identified and classified into 4 types: A (OD, adenoma; histology, serrated), 45/133 (33.8%); B (OD, serrated; histology, adenoma), 55/133 (41.4%); C (OD, adenoma; histology, normal), 19/133 (14.3%); and D (OD, serrated; histology, normal), 14/133 (10.5%). The remaining 51 of 184 errors were because of a pathology error requiring deeper levels (43/184), pathology observer or laboratory error (7/184), or other error (1/184). CONCLUSIONS: OD errors can be related to endoscopist-related factors such as poor photodocumentation, failures of current classification systems, and incomplete histology. We identified a subset of serrated polyps frequently misdiagnosed as adenomas ("pseudoadenomas") using the NBI International Colorectal Endoscopic (NICE) classification. An enhanced algorithm for OD is proposed based on the NICE classification including morphologic and adjunct polyp features.


Subject(s)
Adenoma , Colonic Polyps , Colorectal Neoplasms , Humans , Colonic Polyps/pathology , Prospective Studies , Colorectal Neoplasms/diagnosis , Colorectal Neoplasms/pathology , Colonoscopy/methods , Adenoma/diagnostic imaging , Adenoma/pathology , Narrow Band Imaging/methods
11.
Endoscopy ; 55(4): 313-319, 2023 04.
Article in English | MEDLINE | ID: mdl-36509103

ABSTRACT

BACKGROUND: Polyp detection and resection during colonoscopy significantly reduce long-term colorectal cancer risk. Computer-aided detection (CADe) may increase polyp identification but has undergone limited clinical evaluation. Our aim was to assess the effectiveness of CADe at colonoscopy within a bowel cancer screening program (BCSP). METHODS: This prospective, randomized controlled trial involved all eight screening-accredited colonoscopists at an English National Health Service (NHS) BCSP center (February 2020 to December 2021). Patients were randomized to CADe or standard colonoscopy. Patients meeting NHS criteria for bowel cancer screening were included. The primary outcome of interest was polyp detection rate (PDR). RESULTS: 658 patients were invited and 44 were excluded. A total of 614 patients were randomized to CADe (n = 308) or standard colonoscopy (n = 306); 35 cases were excluded from the per-protocol analysis due to poor bowel preparation (n = 10), an incomplete procedure (n = 24), or a data issue (n = 1). Endocuff Vision was frequently used and evenly distributed (71.7 % CADe and 69.2 % standard). On intention-to-treat (ITT) analysis, there was a borderline significant difference in PDR (85.7 % vs. 79.7 %; P = 0.05) but no significant difference in adenoma detection rate (ADR; 71.4 % vs. 65.0 %; P = 0.09) for CADe vs. standard groups, respectively. On per-protocol analysis, no significant difference was observed in these rates. There was no significant difference in procedure times. CONCLUSIONS: In high-performing colonoscopists in a BCSP who routinely used Endocuff Vision, CADe improved PDR but not ADR. CADe appeared to have limited benefit in a BCSP setting where procedures are performed by experienced colonoscopists.


Subject(s)
Colonic Polyps , Colorectal Neoplasms , Humans , Colonic Polyps/diagnostic imaging , Colorectal Neoplasms/diagnosis , State Medicine , Prospective Studies , Colonoscopy/methods , Early Detection of Cancer/methods , Computers , Artificial Intelligence
13.
Cancer Immunol Res ; 11(1): 20-37, 2023 01 03.
Article in English | MEDLINE | ID: mdl-36409838

ABSTRACT

The central nervous system (CNS) antigen-presenting cell (APC) that primes antitumor CD8+ T-cell responses remains undefined. Elsewhere in the body, the conventional dendritic cell 1 (cDC1) performs this role. However, steady-state brain parenchyma cDC1 are extremely rare; cDCs localize to the choroid plexus and dura. Thus, whether the cDC1 play a function in presenting antigen derived from parenchymal sources in the tumor setting remains unknown. Using preclinical glioblastoma (GBM) models and cDC1-deficient mice, we explored the presently unknown role of cDC1 in CNS antitumor immunity. We determined that, in addition to infiltrating the brain tumor parenchyma itself, cDC1 prime neoantigen-specific CD8+ T cells against brain tumors and mediate checkpoint blockade-induced survival benefit. We observed that cDC, including cDC1, isolated from the tumor, the dura, and the CNS-draining cervical lymph nodes harbored a traceable fluorescent tumor antigen. In patient samples, we observed several APC subsets (including the CD141+ cDC1 equivalent) infiltrating glioblastomas, meningiomas, and dura. In these same APC subsets, we identified a tumor-specific fluorescent metabolite of 5-aminolevulinic acid, which fluorescently labeled tumor cells during fluorescence-guided GBM resection. Together, these data elucidate the specialized behavior of cDC1 and suggest that cDC1 play a significant role in CNS antitumor immunity.


Subject(s)
Dendritic Cells , Neoplasms , Animals , Mice , CD8-Positive T-Lymphocytes , Antigens, Neoplasm , Brain
14.
J Surg Res ; 282: 262-269, 2023 02.
Article in English | MEDLINE | ID: mdl-36332305

ABSTRACT

INTRODUCTION: Early introduction to essential communication skills is important. We sought to determine if a handoff curriculum (HC) would improve confidence, decrease anxiety, and increase participation in clinical handoffs during the surgical clerkship. METHODS: A multi-center prospective cohort study was performed at two medical schools. Training in the intervention group (HC) consisted of a didactic lecture, video review, and practice session. Students completed a pre-clerkship knowledge test and confidence/anxiety/handoff experience questionnaire pre- and post-clerkship. RESULTS: There were no significant differences in pre-clerkship handoff experiences between institutions except having previously witnessed a verbal handoff (School A 96.4% versus School B 76.2%, P = 0.01). While there were no significant differences in post-clerkship confidence or anxiety, HC students were significantly more involved with written sign-outs (52.9% versus 18.2%, P = 0.02) and verbal handoffs (29.4% versus 4.6%, P = 0.03). CONCLUSIONS: Medical students exposed to handoff training shared similar confidence and anxiety scores compared to those that were not, however, they were more involved in handoff experiences during their surgical clerkship. Early introduction to handoff skills may encourage greater participation during subsequent clinical experiences.


Subject(s)
Clinical Clerkship , Patient Handoff , Students, Medical , Humans , Prospective Studies , Curriculum
15.
Frontline Gastroenterol ; 13(5): 374-380, 2022.
Article in English | MEDLINE | ID: mdl-36051952

ABSTRACT

Objective: Our aim was to determine aetiology of post-colonoscopy colorectal cancers (PCCRCs) identified from population-based data through local root cause analysis at a high-volume mixed secondary and tertiary referral centre. Design/method: A subset of national cancer registration data, collected by the National Cancer Registration and Analysis Service, was used to determine PCCRCs diagnosed between 2005 and 2013 at our centre.Root cause analysis was performed for each identified PCCRC, using World Endoscopy Organisation recommendations, to validate it and assess most plausible explanation. We also assessed whether patient, clinician and/or service factors were primarily responsible. Results: Of 107 'PCCRC' cases provided from the national dataset, 20 were excluded (16 missing data, 4 duplicates). 87 'PCCRC' cases were included of which 58 were true PCCRCs and 29 false PCCRCs.False PCCRCs comprised 17 detected cancers (cancer diagnosed within 6 months of negative colonoscopy) and 12 cases did not meet PCCRC criteria. Inflammatory bowel disease was the most common risk factor (18/58) and the most common site was rectum (19/58). The most common explanation was 'possible missed lesion, prior examination negative but inadequate' (23/58) and clinician factors were primarily responsible for PCCRC occurrence in most cases (37/58). Conclusion: Our single-centre study shows, after local analysis, there was misclassification of PCCRCs identified from a population-based registry. The degree of such error will vary between registries. Most PCCRCs occurred in cases of sub-optimal examination as indicated by poor photodocumentation. Effective mechanisms to feedback root cause analyses are critical for quality improvement.

16.
Am J Surg ; 224(5): 1247-1251, 2022 11.
Article in English | MEDLINE | ID: mdl-35780075

ABSTRACT

BACKGROUND: Women remain underrepresented in surgery. We analyzed the demographics of general surgery program directors (PDs) and compared gender differences. METHODS: A search of online resources was conducted, including 344 general surgery residencies. RESULTS: 340 residencies were included. 261 PDs (76.8%) were male and 79 (23.2%) were female. Females were appointed at a younger age (p < 0.0001), were appointed sooner after residency (p < 0.0001) and have served similar term lengths compared to males (p = 0.556). There was no difference in academic position, fellowship training, or scholarly output between genders. Residencies with a female PD had a greater percentage of female residents (p = 0.04). CONCLUSION: General surgery PDs are predominately male with fellowship training; however the percentage of female PDs is similar to the percentage of practicing female general surgeons in the US. Gaining a better understanding of the characteristics of general surgery PDs can aid female surgeons in attaining academic leadership positions.


Subject(s)
General Surgery , Internship and Residency , Surgeons , Female , Male , United States , Humans , Fellowships and Scholarships , Leadership , General Surgery/education
17.
18.
Gastrointest Endosc ; 96(6): 1021-1032.e2, 2022 12.
Article in English | MEDLINE | ID: mdl-35724693

ABSTRACT

BACKGROUND AND AIMS: Optical diagnosis (OD) of polyps can be performed with advanced endoscopic imaging. For high-confidence diagnoses, a "resect and discard" strategy could offer significant histopathology time and cost savings. The implementation threshold is a ≥90% OD-histology surveillance interval concordance. Here we assessed the OD learning curve and feasibility of a resect and discard strategy for ≤5-mm and <10-mm polyps in a bowel cancer screening setting. METHODS: In this prospective feasibility study, 8 bowel cancer screening endoscopists completed a validated OD training module and performed procedures. All <10-mm consecutive polyps had white-light and narrow-band images taken and were given high- or low-confidence diagnoses until 120 high-confidence ≤5-mm polyp diagnoses had been performed. All polyps had standard histology. High-confidence OD errors underwent root-cause analysis. Histology and OD-derived surveillance intervals were calculated. RESULTS: Of 565 invited patients, 525 patients were included. A total of 1560 <10-mm polyps underwent OD and were resected and retrieved (1329 ≤5 mm and 231 6-9 mm). There were no <10-mm polyp cancers. High-confidence OD was accurate in 81.5% of ≤5-mm and 92.8% of 6-9-mm polyps. Sensitivity for OD of a ≤5-mm adenoma was 93.0% with a positive predictive value of 90.8%. OD-histology surveillance interval concordance for ≤5-mm OD was 91.3% (209/229) for U.S. Multi-Society Task Force, 98.3% (225/229) for European Society of Gastrointestinal Endoscopy, and 98.7% (226/229) for British Society of Gastroenterology guidelines, respectively. CONCLUSIONS: A resect and discard strategy for high-confidence ≤5-mm polyp OD in a group of bowel cancer screening colonoscopists is feasible and safe, with performance exceeding the 90% surveillance interval concordance required for implementation in clinical practice. (Clinical trial registration number: NCT04710693.).


Subject(s)
Adenoma , Colonic Polyps , Colorectal Neoplasms , Humans , Adenoma/diagnostic imaging , Adenoma/surgery , Colonic Polyps/diagnostic imaging , Colonic Polyps/surgery , Colonoscopy/methods , Colorectal Neoplasms/diagnosis , Colorectal Neoplasms/surgery , Colorectal Neoplasms/pathology , Prospective Studies
19.
Health Technol Assess ; 26(26): 1-156, 2022 05.
Article in English | MEDLINE | ID: mdl-35635015

ABSTRACT

BACKGROUND: Colonoscopy surveillance is recommended for some patients post polypectomy. The 2002 UK surveillance guidelines classify post-polypectomy patients into low, intermediate and high risk, and recommend different strategies for each classification. Limited evidence supports these guidelines. OBJECTIVES: To examine, for each risk group, long-term colorectal cancer incidence by baseline characteristics and the number of surveillance visits; the effects of interval length on detection rates of advanced adenomas and colorectal cancer at first surveillance; and the cost-effectiveness of surveillance compared with no surveillance. DESIGN: A retrospective cohort study and economic evaluation. SETTING: Seventeen NHS hospitals. PARTICIPANTS: Patients with a colonoscopy and at least one adenoma at baseline. MAIN OUTCOME MEASURES: Long-term colorectal cancer incidence after baseline and detection rates of advanced adenomas and colorectal cancer at first surveillance. DATA SOURCES: Hospital databases, NHS Digital, the Office for National Statistics, National Services Scotland and Public Health England. METHODS: Cox regression was used to compare colorectal cancer incidence in the presence and absence of surveillance and to identify colorectal cancer risk factors. Risk factors were used to stratify risk groups into higher- and lower-risk subgroups. We examined detection rates of advanced adenomas and colorectal cancer at first surveillance by interval length. Cost-effectiveness of surveillance compared with no surveillance was evaluated in terms of incremental costs per colorectal cancer prevented and per quality-adjusted life-year gained. RESULTS: Our study included 28,972 patients, of whom 14,401 (50%), 11,852 (41%) and 2719 (9%) were classed as low, intermediate and high risk, respectively. The median follow-up time was 9.3 years. Colorectal cancer incidence was 140, 221 and 366 per 100,000 person-years among low-, intermediate- and high-risk patients, respectively. Attendance at one surveillance visit was associated with reduced colorectal cancer incidence among low-, intermediate- and high-risk patients [hazard ratios were 0.56 (95% confidence interval 0.39 to 0.80), 0.59 (95% confidence interval 0.43 to 0.81) and 0.49 (95% confidence interval 0.29 to 0.82), respectively]. Compared with the general population, colorectal cancer incidence without surveillance was similar among low-risk patients and higher among high-risk patients [standardised incidence ratios were 0.86 (95% confidence interval 0.73 to 1.02) and 1.91 (95% confidence interval 1.39 to 2.56), respectively]. For intermediate-risk patients, standardised incidence ratios differed for the lower- (0.70, 95% confidence interval 0.48 to 0.99) and higher-risk (1.46, 95% confidence interval 1.19 to 1.78) subgroups. In each risk group, incremental costs per colorectal cancer prevented and per quality-adjusted life-year gained with surveillance were lower for the higher-risk subgroup than for the lower-risk subgroup. Incremental costs per quality-adjusted life-year gained were lowest for the higher-risk subgroup of high-risk patients at £7821. LIMITATIONS: The observational design means that we cannot assume that surveillance caused the reductions in cancer incidence. The fact that some cancer staging data were missing places uncertainty on our cost-effectiveness estimates. CONCLUSIONS: Surveillance was associated with reduced colorectal cancer incidence in all risk groups. However, in low-risk patients and the lower-risk subgroup of intermediate-risk patients, colorectal cancer incidence was no higher than in the general population without surveillance, indicating that surveillance might not be necessary. Surveillance was most cost-effective for the higher-risk subgroup of high-risk patients. FUTURE WORK: Studies should examine the clinical effectiveness and cost-effectiveness of post-polypectomy surveillance without prior classification of patients into risk groups. TRIAL REGISTRATION: This trial is registered as ISRCTN15213649. FUNDING: This project was funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 26, No. 26. See the NIHR Journals Library website for further project information.


Bowel cancers develop from polyps, also called adenomas, which are growths on the lining of the bowel. Removal of adenomas, therefore, helps prevent bowel cancer. Adenomas can be detected and removed during colonoscopy, when a thin tube with a camera on one end is used to examine the bowel lining. In the UK, patients with adenomas are divided into three risk groups. Low-risk patients (i.e. those with one or two adenomas that are < 10 mm in size) are thought to be unlikely to develop bowel cancer after adenoma removal and follow-up colonoscopy is not recommended in this group. Intermediate-risk patients (i.e. those with three or four adenomas that are < 10 mm in size, or one or two adenomas with at least one ≥ 10 mm in size) are recommended to have another colonoscopy 3 years after adenoma removal. High-risk patients (i.e. those with five or more adenomas that are < 10 mm in size, or three or more adenomas with at least one ≥ 10 mm in size) are recommended to have another colonoscopy after 1 year and then usually again after 3 years. The number of follow-up colonoscopies carried out is stretching health-care resources and each procedure carries a small risk of complications for patients. It is possible that too many follow-up colonoscopies are being carried out. This study aimed to determine which patients require follow-up colonoscopies and how many are required to detect adenomas and prevent bowel cancer, while also being resource-efficient, cost-effective and not exposing patients to unnecessary risks. The study used data from 17 hospitals and cancer registries in the UK. In each risk group, one follow-up colonoscopy after adenoma removal was associated with a 40­50% reduction in bowel cancer risk. However, even without any follow-up, bowel cancer risk was no higher in some low- and intermediate-risk patients than in the general population. These patients may not need as many follow-up colonoscopies as recommended. In the case of higher-risk patients, who even after adenoma removal have a higher bowel cancer risk than the general population, follow-up colonoscopies are necessary and cost-effective.


Subject(s)
Adenoma , Colorectal Neoplasms , Adenoma/epidemiology , Adenoma/prevention & control , Colonoscopy , Colorectal Neoplasms/diagnosis , Colorectal Neoplasms/epidemiology , Colorectal Neoplasms/prevention & control , Cost-Benefit Analysis , Humans , Retrospective Studies
20.
Endoscopy ; 54(10): 948-958, 2022 10.
Article in English | MEDLINE | ID: mdl-35405762

ABSTRACT

BACKGROUND: Longer post-polypectomy surveillance intervals are associated with increased colorectal neoplasia detection at surveillance in some studies. We investigated this association to inform optimal surveillance intervals. METHODS: Patients who underwent colonoscopy and post-polypectomy surveillance at 17 UK hospitals were classified as low/high risk by baseline findings. We compared detection rates of advanced adenomas (≥ 10 mm, tubulovillous/villous, high grade dysplasia), high risk findings (HRFs: ≥ 2 serrated polyps/[adenomas] of which ≥ 1 is ≥ 10 mm or has [high grade] dysplasia; ≥ 5 serrated polyps/adenomas; or ≥ 1 nonpedunculated polyp ≥ 20 mm), or colorectal cancer (CRC) at surveillance colonoscopy by surveillance interval (< 18 months, 2, 3, 4, 5, 6 years). Risk ratios (RRs) were estimated using multivariable regression. RESULTS: Of 11 214 patients, 7216 (64 %) were low risk and 3998 (36 %) were high risk. Among low risk patients, advanced adenoma, HRF, and CRC detection rates at first surveillance were 7.8 %, 3.7 %, and 1.1 %, respectively. Advanced adenoma detection increased with increasing surveillance interval, reaching 9.8 % with a 6-year interval (P trend < 0.001). Among high risk patients, advanced adenoma, HRF, and CRC detection rates at first surveillance were 15.3 %, 10.0 %, and 1.5 %, respectively. Advanced adenoma and CRC detection rates (P trends < 0.001) increased with increasing surveillance interval; RRs (95 % confidence intervals) for CRC were 1.54 (0.68-3.48), 4.44 (1.95-10.08), and 5.80 (2.51-13.40) with 3-, 4-, and 5-year intervals, respectively, versus an interval of < 18 months. CONCLUSIONS: Metachronous neoplasia was uncommon among low risk patients, even with long surveillance intervals, supporting recommendations for no surveillance in these patients. For high risk patients, a 3-year surveillance interval would ensure timely CRC detection.


Subject(s)
Adenoma , Colonic Polyps , Colorectal Neoplasms , Adenoma/diagnosis , Adenoma/epidemiology , Adenoma/surgery , Colonic Polyps/diagnosis , Colonic Polyps/epidemiology , Colonic Polyps/surgery , Colonoscopy , Colorectal Neoplasms/diagnosis , Colorectal Neoplasms/epidemiology , Colorectal Neoplasms/surgery , Humans , Retrospective Studies , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...