Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-15973699

ABSTRACT

BACKGROUND: Clinical indications for lymphocyte subset enumeration by flow cytometry include monitoring of disease progression and timing of therapeutic intervention in infection with human immunodeficiency virus. Until recently international standardisation has not been possible due to a lack of suitable stable reference material. METHODS: This study consisted of two trials of a stabilised whole blood preparation. Eleven participants were sent two standard protocols for staining plus gating strategy and asked to report absolute counts for lymphocyte subsets. RESULTS: No significant difference was detected between the two methods when results from the two assays and all partners were pooled. Significant differences in results from the different partners were observed. However, representative mean counts were obtained for geometric means, geometric coefficient of variation, and 95% confidence interval for CD3 910 cells/mul, 9%, and 888 to 933, respectively), CD4 (495 cells/mul, 12%, and 483 to 507), and CD8 (408 cells/mul, 13%, and 393 to 422). CONCLUSION: We have introduced a stabilised blood preparation and a well-characterized biological standard. The availability of this reference material greatly simplifies the validation of new techniques for CD4(+) T-cell enumeration and the expansion of external quality assurance programmes for clinical laboratories, including those that operate in resource-restricted environments. (c) 2005 Wiley-Liss, Inc.

2.
Cytometry B Clin Cytom ; 57(1): 47-52, 2004 Jan.
Article in English | MEDLINE | ID: mdl-14696063

ABSTRACT

BACKGROUND: The derivation of reliable CD4(+) T lymphocyte counts is vital for the monitoring of disease progression and therapeutic effectiveness in HIV(+) individuals. Flow cytometry has emerged as the method of choice for CD4(+) T lymphocyte enumeration, with single-platform technology, coupled with reference counting beads, fast becoming the "gold standard." However, although single-platform, bead-based, sample acquisition requires the ratio of beads to cells to remain unchanged, there is no available method, until recently, to monitor this. METHODS: Perfect Count beads have been developed to address this issue and to incorporate two bead populations, with different densities, to allow the detection of inadequate mixing. Comparison of the relative proportions of both beads with the manufacture's defined limits enables an internal QC check during sample acquisition. In this study, we have compared CD4(+) T lymphocyte counts, obtained from 104 HIV(+) patients, using TruCount beads with MultiSet software (defined as the predicated method) and the new Perfect Count beads, incorporating an in house sequential gating strategy. RESULTS: We have demonstrated an excellent degree of correlation between the predicate method and the Perfect Count system (r(2) = 0.9955; Bland Altman bias +27 CD4(+) T lymphocytes/microl). CONCLUSIONS: The Perfect Count system is a robust method for performing single platform absolute counts and has the added advantage of having internal QC checks. Such an approach enables the operator to identify potential problems during sample preparation, acquisition and analysis.


Subject(s)
CD4-Positive T-Lymphocytes/immunology , Lymphocyte Count/methods , CD4-Positive T-Lymphocytes/cytology , Flow Cytometry/methods , HIV Infections/blood , HIV Infections/immunology , Humans , Reproducibility of Results , Sensitivity and Specificity
3.
Cytometry B Clin Cytom ; 55(1): 1-7, 2003 Sep.
Article in English | MEDLINE | ID: mdl-12949953

ABSTRACT

BACKGROUND: Reports suggest that flow rate (FR) is constant on bench top flow cytometers. Therefore, if FR is constant, the volume acquired in a fixed time period will also be constant, enabling absolute leucocyte counting using flow rate calibration (FRC). METHODS: FR stability was ascertained on a standard FACSCalibur by counting TruCount beads suspended in phosphate buffered saline over 120 s. Studies using two lysing solutions (FACS lysing solution and PharM Lyse) and corresponding sample lysates established a lysing solution calibration factor (CF). Absolute CD4(+) T-lymphocyte counts on 10 peripheral blood samples determined using FRC were compared with the predicate method TruCount/MultiTEST, incorporating MultiSET software. Linearity studies were also performed at three different flow rates. RESULTS: A high degree of linearity over a wide range of counts (50 to >1,600 CD4(+) T lymphocytes/microl) at all three pressures was observed. Importantly, there was no significant difference from the predicate method when appropriate lysing solution CF was used. CONCLUSIONS: Using a simple calibration procedure and incorporation of an appropriate lysing solution CF, we show that FRC can easily be performed. The technical details that underpin this novel approach for absolute leucocyte enumeration are provided.


Subject(s)
CD4 Lymphocyte Count/methods , Flow Cytometry/methods , CD4-Positive T-Lymphocytes/cytology , Calibration , Evaluation Studies as Topic , Humans , Quality Control
4.
Cytometry B Clin Cytom ; 55(1): 8-13, 2003 Sep.
Article in English | MEDLINE | ID: mdl-12949954

ABSTRACT

BACKGROUND: CD4(+) T-lymphocyte enumeration is vital for monitoring disease progression in individuals positive for the human immunodeficiency virus (HIV), and as a result, there is a need to develop cost-effective protocols that provide accuracy, precision, and affordability. Recently, PanLeucoGating has been shown to fulfill these requirements; however, although comparable to state-of-the-art single-platform protocols (SP), there is still a requirement for an accurate total white cell count. To overcome this limitation, we recently developed a flow-rate based calibration method that enables the PanLeucoGating protocol to be used as a SP approach, and in this study show that this approach can be used for CD4(+) T-lymphocyte enumeration. METHODS: A total of 113 HIV samples were analyzed using three protocols: (a) state-of-the art SP bead-based method (MultiSet; predicate protocol), (b) PanLeucoGating protocol used as a dual-platform (DP) approach, and (c) the newly developed flow rate-based SP approach. We demonstrate that flow rate calibration can be achieved easily and that the method is highly comparable to the state-of-the-art SP method. RESULTS: A high correlation was observed between the predicate protocol and the SP PanLeucoGating approach over the whole range of CD4 counts tested (r(2) = 0.9928; bias 8 cells/microl), including the clinically relevant range (e.g., 0-200 CD4 cells/microl; bias 0 cells/microl). For batched samples, the cost of providing a CD4(+) T-lymphocyte count was reduced to approximately US $1. CONCLUSIONS: The SP PanLeucoGating is a cost-effective approach to CD4(+) T-lymphocyte enumeration that maintains accuracy and precision.


Subject(s)
CD4 Lymphocyte Count/methods , Flow Cytometry/methods , Animals , CD4 Lymphocyte Count/economics , CD4-Positive T-Lymphocytes/cytology , CD4-Positive T-Lymphocytes/virology , Calibration , Evaluation Studies as Topic , Flow Cytometry/economics , HIV Infections/physiopathology , Humans , Quality Control , Sensitivity and Specificity
5.
Cytometry ; 50(2): 102-10, 2002 Apr 15.
Article in English | MEDLINE | ID: mdl-12116352

ABSTRACT

The human immunodeficiency virus (HIV) global epidemic has necessitated the routine enumeration of T-lymphocyte subsets, which has created a need for external quality assurance (EQA). The United Kingdom National External Quality Assessment Scheme (UK NEQAS) for Immune Monitoring provides EQA for 296 laboratories in 40 countries. In 1993, UK NEQAS developed and incorporated into its program stabilized whole blood that enables the accurate monitoring of laboratory performance. Overall, the mean interlaboratory coefficient of variation (CV) for percentage CD4(+) T-lymphocyte subset enumeration has fallen from 15% to less than 5%, as a direct result of the increased use of CD45/ side scatter (SSC) gating. Laboratories using alternative gating strategies (i.e., CD45/CD14 or forward scatter [FSC]/SSC) were about 7.4 times more likely to fail an EQA exercise. Furthermore, the adoption of single-platform technology resulted in a reduction of the overall mean interlaboratory CV for absolute CD4(+) T lymphocytes from 56% (prior to the widespread use of single-platform technology) to 9.7%. Individual laboratory deficiencies were also identified using a performance monitoring system and, through re-education by collaboration with the coordinating center, satisfactorily resolved. In conclusion, during the last 9 years, the UK NEQAS for Immune Monitoring program has highlighted the significant technological advances made by laboratories worldwide that undertake lymphocyte subset enumeration.


Subject(s)
CD4-Positive T-Lymphocytes/cytology , Immunophenotyping/methods , CD3 Complex/blood , CD4 Antigens/blood , HIV Seropositivity/blood , HIV Seropositivity/diagnosis , Humans , Leukocyte Common Antigens/blood , Quality Control , United Kingdom
6.
J Lipid Res ; 43(2): 335-43, 2002 Feb.
Article in English | MEDLINE | ID: mdl-11861676

ABSTRACT

Determination of the circulating levels of plasma lipoproteins HDL, LDL, and VLDL is critical in the assessment of risk of coronary heart disease. More recently it has become apparent that the LDL subclass pattern is a further important diagnostic parameter. The reference method for separation of plasma lipoproteins is ultracentrifugation. However, current methods often involve prolonged centrifugation steps and use high salt concentrations, which can modify the lipoprotein structure and must be removed before further analysis. To overcome these problems we have now investigated the use of rapid self-generating gradients of iodixanol for separation and analysis of plasma lipoproteins. A protocol is presented in which HDL, LDL, and VLDL, characterized by electron microscopy and agarose gel electophoresis, separate in three bands in a 2.5 h centrifugation step. Recoveries of cholesterol and TG from the gradients were close to 100%. The distribution profiles of cholesterol and TG in the gradient were used to calculate the concentrations of individual lipoprotein classes. The values correlated with those obtained using commercial kits for HDL and LDL cholesterol. The position of the LDL peak in the gradient and its shape varied between plasma samples and was indicative of the density of the predominant LDL class. The novel protocol offers a rapid, reproducible and accurate single-step centrifugation method for the determination of HDL, LDL, and VLDL cholesterol, and TG, and identification of LDL subclass pattern.


Subject(s)
Centrifugation, Density Gradient/methods , Cholesterol, HDL/blood , Cholesterol, LDL/blood , Cholesterol, VLDL/blood , Triglycerides/blood , Cholesterol, HDL/isolation & purification , Cholesterol, LDL/isolation & purification , Cholesterol, VLDL/isolation & purification , Humans , Hyperlipidemias/blood , Reproducibility of Results , Triglycerides/isolation & purification , Triiodobenzoic Acids/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...