Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Imaging Sci ; 12: 37, 2022.
Article in English | MEDLINE | ID: mdl-36128350

ABSTRACT

Objectives: To investigate the effect of serum glucose level and other confounding factors on the variability of maximum standardized uptake value (SUVmax) in normal tissues within the same patient on two separate occasions and to suggest an ideal reference tissue. Materials and Methods: We retrospectively reviewed 334 18F-FDG PET/CT scans of 167 cancer patients including 38 diabetics. All patients had two studies, on average 152 ± 68 days apart. Ten matched volumes of interest were drawn on the brain, right tonsil, blood pool, heart, lung, liver, spleen, bone marrow, fat, and iliopsoas muscle opposite third lumber vertebra away from any pathological 18F-FDG uptake to calculate SUVmax. Results: SUVmax of the lungs and heart were significantly different in the two studies (P = 0.003 and P = 0.024 respectively). Only the brain uptake showed a significant moderate negative correlation with the level of blood glucose in diabetic patients (r = -0.537, P = 0.001) in the first study, while the SUVmax of other tissues showed negligible or weak correlation with the level of blood glucose in both studies.The liver showed significant moderate positive correlation with body mass index (BMI) in both studies (r = .416, P = <0.001 versus r = 0.453, P = <0.001, respectively), and blood pool activity showed significant moderate positive correlation with BMI in the first study only (r = 0.414, P = <0.001). The liver and blood pool activities showed significant moderate negative correlation with 18F-FDG uptake time in first study only (r = -0.405, P-value = <0.001; and r = -0.409, P-value = <0.001, respectively).In the multivariate analysis, the liver showed a consistent effect of the injected 18F-FDG dose and uptake duration on its SUVmax on the two occasions. In comparison, spleen and muscle showed consistent effect only of the injected dose on the two occasions. Conclusion: The liver, muscle, and splenic activities showed satisfactory test/retest stability and can be used as reference activities. The spleen and muscle appear to be more optimal reference than the liver, as it is only associated with the injected dose of 18F-FDG.

2.
J Vasc Surg Venous Lymphat Disord ; 10(2): 482-490, 2022 03.
Article in English | MEDLINE | ID: mdl-35026448

ABSTRACT

BACKGROUND: Percutaneous endovenous stenting has emerged during the past decade as the primary method of treating symptomatic venous outflow obstruction. A recognized complication of venous stenting is stent migration. The aim of the present systematic review was to identify the number of cases of stent migration in reported studies to recognize the risk factors that might be associated with this complication and the outcomes following migration. METHODS: A review was conducted in accordance with the MOOSE (meta-analyses of observational studies in epidemiology) and PRIMSA (preferred reporting items for systematic review and meta-analysis) guidelines and registered in the PROSPERO. MEDLINE, EMBASE, and PubMed databases. Key references were searched using specified keywords. All relevant data for the primary procedure and subsequent presentation with stent migration were retrieved. The data were assessed as too low in quality to allow for statistical analysis. RESULTS: Between 1994 and 2020, 31 studies were identified, including 29 case reports and 2 case series, providing data for 54 events of venous stent migration with some data provided regarding the stent used for 47 of the events. The mean age of the 52 patients with stent migration was 50 years (range, 19-88 years) and 30 were men (57.6%). The stents for most of the reported cases were ≤60 mm in length (38 of 46; 82.6%). Only three of the reports were of stents >14 mm in diameter (3 of 47; 3.6%). None of the studies had reported migration of stents >100 mm long. In 85% of the migrated stent events, retrieval was attempted, with 65.2% via an endovascular approach. The immediate outcome was satisfactory for 100% of the reported attempts, whether by an endovascular or open surgical approach. CONCLUSIONS: The findings from our literature review suggest that the risk of migration is rare but might be underreported. Most of reported cases had occurred with shorter and smaller diameter stents. The paucity of reported data and the short-term follow-up provided suggest that more formal data collection would provide a truer reflection of the incidence. However, clear strategies to avoid migration should be followed to prevent this complication from occurring.


Subject(s)
Device Removal , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Foreign-Body Migration/epidemiology , Foreign-Body Migration/therapy , Stents , Veins , Adult , Aged , Aged, 80 and over , Device Removal/adverse effects , Female , Foreign-Body Migration/diagnostic imaging , Humans , Incidence , Male , Middle Aged , Risk Assessment , Risk Factors , Treatment Outcome , Veins/diagnostic imaging , Young Adult
3.
Indian J Nucl Med ; 30(4): 314-9, 2015.
Article in English | MEDLINE | ID: mdl-26430314

ABSTRACT

OBJECTIVES: Assess the added value of dual time point F-18-fluorodeoxyglucose positron emission tomography/computed tomography (DTP F-18-FDG-PET/CT) in the differentiation of malignant from a benign lesion in cancer patients. MATERIALS AND METHODS: Totally, 140 F-18-FDG PET/CT scans of 60 cancer patients who underwent DTP protocol (early whole body PET/CT [E] at 60 min [range, 45-76 min] and delayed limited PET/CT [D] on areas of interest at 120 min [range, 108-153 min] after the tracer injection) were retrospectively reviewed. Visual and semi-quantitative analysis was performed on both early and delayed images. All findings were confirmed by histopathology and/or at least 3 months follow-up (F-18-FDG PET/CT, CT, or magnetic resonance imaging). The result was considered true positive (TP) if delayed standardized uptake value (SUV) of suspicious lesions increased and confirmed to be malignant, false positive (FP) if delayed SUV increased and confirmed to be benign, true negative (TN) if delayed SUV unchanged or decreased and confirmed to be benign, and false negative (FN) if delayed SUV unchanged or decreased and confirmed to be malignant. RESULTS: A total of 164 suspicious lesions were detected (20 presacral lesions, 18 lung nodules, 18 Hodgkin's disease (HD) lesions, 16 rectal lesions, 16 head and neck (H and N) lesions, 14 hepatic lesions, 14 non-Hodgkin's lymphoma (NHL) lesions, 12 mediastinal lymph nodes (LNs), 10 focal gastric uptake, 10 soft tissue lesions, 8 breast lesions, 4 peritoneal nodule, and 4 others). Sixty-four lesions were pathologically confirmed, and 100 lesions were confirmed based on 3-6 months follow-up. There were 62 TP lesions, 44 FP, 58 TN and no FN results. The overall sensitivity was 100% of DTP F-18-FDG PET/CT in detecting suspicious lesions. The specificity was 57% in differentiating malignant from benign lesions, and the accuracy was 73%. Positive predictive value was 59%, negative predictive value (NPV) 100%. All hepatic lesions were TP. Accuracy in metastatic hepatic lesions HD, presacral soft tissue, lung nodules, H, and N cancer, breast cancer, NHL and mediastinal LN was100%, 88.8%, 80%, 78%, 75%, 75%, 71%, and 33.3%, respectively. CONCLUSIONS: DTP F-18-FDG-PET/CT protocol does not always work in differentiation between benign and malignant lesions. However; it has high NPV, and promising results was noted in hepatic lesions, lymphoma, and recurrent rectal cancer.

4.
Indian J Nucl Med ; 30(2): 116-21, 2015.
Article in English | MEDLINE | ID: mdl-25829728

ABSTRACT

OBJECTIVES: The rate and impact of thyroglossal duct remnant (TGDR) visualization in patients with hypothyroidism after total thyroidectomy for differentiated thyroid carcinoma (DTC) have not yet been fully determined. The aim of this study was to assess the rate of TGDR visualization in post total thyroidectomy whole body scan (WBS) for DTC and to evaluate its impact on the outcome of I-131 ablation. METHODS: A total of 60 consecutive DTC patients (51 papillary thyroid Ca., and 9 Follicular thyroid Ca.), underwent total thyroidectomy, followed by WBS (using I-131 in 28 patients and I-123 in 32 patients), neck ultrasound (US), thyroglobulin (Tg) and Tg anti-bodies (TgAb) assay after 40 days and subsequent I-131 ablation. At 6 months later follow-up I-131 WBS, neck U/S, Tg and TgAb were performed following suspension of L-thyroxine for 1-month (thyroid stimulating hormone [TSH] >30 µIU/ml) in 53 patients and following recombinant human TSH stimulation in seven patients. RESULTS: Of the studied 60 patients, 19/60 (31.7%) had a linear or focal radioactivity at the superior midline of the neck, suggesting TGDR (Group 1), and 41/60 (68.3%) had no uptake to suggest TGDR (Group 2). No significant difference regarding age, gender and histopathology between both groups. Neck US showed no evidence of thyroid tissue in the superior midline of the neck in both groups, and only a small or no residual thyroid tissue in patients of Group 1. There was a significant successful I-131 ablation rate among patients of group 1 compared to group 2 (79% in Group 1 vs. 41.5% in Group 2) (P = 0.007). CONCLUSIONS: Thyroglossal duct remnant visualization on WBS of hypothyroid subjects after total thyroidectomy suggests presence of only a small or no residual functioning thyroid tissue at the thyroid bed and can predict a good response to I-131 ablation.

5.
Indian J Nucl Med ; 30(1): 26-30, 2015.
Article in English | MEDLINE | ID: mdl-25589802

ABSTRACT

OBJECTIVES: Renal cortical scintigraphy with technetium-99m (Tc-99m) dimercaptosuccinic acid (DMSA) is the method of choice to detect acute pyelonephritis and cortical scarring. Different acquisition methods have been used: Planar parallel-hole or pinhole collimation and single photon emission tomography (SPECT). This study compared planar parallel-hole cortical scintigraphy and dual-head SPECT for detection of cortical defects. PATIENTS AND METHODS: We retrospectively reviewed 190 consecutive patients with 380 kidneys and 200 DMSA scans referred to rule out renal cortical scarring. The diagnoses were 52 vesicoureteric reflux, 61 recurrent urinary tract infection, 39 hydronephrosis, 20 renal impairment, and 18 hypertension. All patients were imaged 3 h after injection of Tc-99m DMSA with SPECT and planar imaging (posterior, anterior, left, and right posterior oblique views). For each patient, planar and SPECT images were evaluated at different sittings, in random order. Each kidney was divided into three cortical segments (upper, middle and lower) and was scored as normal or reduced uptake. The linear correlation coefficient for the number of abnormal segments detected between planner and SPECT techniques was calculated. RESULTS: From 200 DMSA scans, 100 scans were positive for scar in SPECT images, from which only 95 scans were positive for scar in planner imaging. Out of the five mismatched scans, three scans were for patients with renal impairment and high background activity and two scans were for very small scars. No significant difference was seen in the average number of abnormal segments detected by planar versus SPECT imaging (P = 0.31). The average correlation coefficient between was high (r = 0.91 - 0.92). CONCLUSIONS: Tc-99m DMSA renal cortical scanning using SPECT offers no statistically significant diagnostic advantage over multiple views planar imaging for detection of cortical defect.

SELECTION OF CITATIONS
SEARCH DETAIL
...