Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Language
Publication year range
1.
Dent Mater ; 37(10): e485-e492, 2021 10.
Article in English | MEDLINE | ID: mdl-34503836

ABSTRACT

OBJECTIVES: The objective of this study was to determine the effects of antimicrobial photodynamic therapy (aPDT) with indocyanine green (ICG) and toluidine blue (TB) on protease activity (matrix-bound cathepsin K and matrix metalloproteinase (MMP) and dentin bond strength. METHODS: Caries-free human third molars were assigned to five groups: 1-control group, 2-application of ICG with activation using an 810 nm diode (aPDT), 3-application of ICG, 4-application of TB with activation using a 660 nm diode (aPDT), and 5-application of TB. For the enzymatic investigation, dentin beams were incubated for either 3 days or 3 weeks. Aliquots of the incubation media were analyzed by ELISA for CTX (C-terminal cross-linked telopeptide of type I Collagen) and ICTP (cross-linked carboxy-terminal telopeptide of type I collagen). For microtensile bond strength testing (µTBS), composite resins were layered onto the tooth surface; the samples were then subjected to µTBS. Kruskall-Wallis and Mann-Whitney U tests were applied for statistical analysis of CTX and ICTP, one way-ANOVA and Tukey's test were applied for statistical analysis of µTBS. RESULTS: Pretreating the dentin matrices with aPDT decreased the endogenous protease activity. ICG with laser activation resulted in the highest µTBS. Therefore, aPDT should be considered as a treatment method because it can reduce MMP-mediated dentin degradation and increase the µTBS. SIGNIFICANCE: Inhibiting endogenous protease activity improves the stability of the dentin-adhesive bond and the durability of the bond strength.


Subject(s)
Dental Bonding , Photochemotherapy , Cathepsin K , Composite Resins , Dentin , Dentin-Bonding Agents , Humans , Materials Testing , Matrix Metalloproteinases , Resin Cements , Tensile Strength
2.
Article in English | MEDLINE | ID: mdl-35070174

ABSTRACT

Background. The surface properties of implants are effective factors for increasing the osseointegration and activity of osteoprogenitor cells. This study compared the stability of dental implants with sandblasted and acid-etched (SLA) and modified surfaces (SLActive) using the resonance frequency analysis (RFA). Methods. In a split-mouth design, 50 dental implants with either SLA surface properties (n=25) or modified (SLActive) surface properties (n=25) were placed in the mandibles of 12 patients with a bilateral posterior edentulous area. Implant stability was measured using RFA (Osstell) at implant placement time and every week for 1, 2, and 3 months before the conventional loading time. Results. One week following the implantation, implant stability increased from 70 to 77.67 for SLA and from 71.67 to 79 for SLActive (P < 0.05). Stability improved each week except in the 4th week in SLActive surface measurements. No significant differences were observed between the groups at 2 and 3 months (P > 0.05). Conclusions. For both implant surfaces, increased stability was observed over time, with no significant differences between the groups.

3.
J Appl Biomater Funct Mater ; 17(4): 2280800019882645, 2019.
Article in English | MEDLINE | ID: mdl-31779504

ABSTRACT

INTRODUCTION: The aim of this study was to evaluate the effect of different heights of attachment and mucosa thicknesses on the stress distribution of two implant-retained mandibular overdenture designs under loading using the photoelastic stress analysis method. MATERIALS AND METHODS: Six photoelastic models of an edentulous mandibula were fabricated with two solitary implants that were placed in the canine regions. The attachment systems studied were ball and locator stud attachments. Both the ball and locator groups included three models that had different residual ridge heights so as to provide different mucosa thicknesses (1 mm-1 mm, 1 mm-2 mm, 1 mm-4 mm). A static vertical force of 135 N was applied unilaterally (each on the right then the left side) to the central fossa of the first molars. Models were positioned in the field of a circular polariscope to observe the distribution of isochromatic fringes around the implants and the interimplant areas under loading. The photoelastic stress fringes were monitored and recorded photographically. RESULTS: The ball attachment groups showed higher stress values than did the locator groups under loading. Both attachment systems produced the lowest stress values in stimulated 1 mm-1 mm mucosa thickness models. The models with 1 mm-2 mm mucosa thicknesses showed higher stress values than did other models for both attachment systems. The highest stress value observed around both attachment systems was the moderate level in all test models. CONCLUSION: In different height mucosa thicknesses, locator attachment models distributed the load to the other side of the implant and its surrounding tissue, whereas the ball attachment did not. Regardless of mucosal thickness and attachment type, the implant on the loading side was subjected to the highest stress concentration.


Subject(s)
Dental Implants , Denture, Overlay , Mandible , Materials Testing , Mouth Mucosa , Animals , Dogs , Humans , Stress, Mechanical
4.
Braz Oral Res ; 33: e053, 2019 Sep 09.
Article in English | MEDLINE | ID: mdl-31531561

ABSTRACT

Self-adhesive resin cements (RCs) activate matrix metalloproteinase (MMP) and cathepsin-related collagen degradation, and gallic acid (GA) inhibits the activity of both MMPs and cysteine cathepsins. The purpose of this study was to evaluate the setting time, biaxial flexural strength, and Vickers hardness of self-adhesive RCs after the addition of two different concentrations of GA. RelyX U200 (3M ESPE) and Panavia SA (Kuraray) were modified with 0.5 and 1 wt% GA. The setting time of five samples in each RC group was assessed using a thermocouple apparatus as described in the ISO 4049 test. Biaxial flexure strength was measured using a universal testing machine until failure. Vickers hardness was measured with three randomized indentations on the surface of each resin disc. RCs without GA were used as control. Data were analyzed using a one-way analysis of variance and Tukey's HSD test (α = 0.05). The setting times ranged from 2.4 to 4.6 min for RelyX and from 4.9 to 6.0 min for Panavia. The biaxial flexure strength ranged from 76.5 to 109.7 MPa for RelyX and from 73.3 to 108.2 MPa for Panavia. Vickers hardness values ranged from 41.6 to 58.6 for RelyX and 27.2 to 33.6 for Panavia. The addition of 0.5 and 1 wt% GA to improve durability of resin-dentin bonds had no adverse effects on setting time, whereas the biaxial flexure strength and Vickers hardness values for the tested materials were significantly reduced.


Subject(s)
Gallic Acid/chemistry , Resin Cements/chemistry , Analysis of Variance , Flexural Strength , Hardness Tests , Materials Testing , Matrix Metalloproteinases/chemistry , Reference Values , Reproducibility of Results , Statistics, Nonparametric , Surface Properties , Time Factors
5.
Photobiomodul Photomed Laser Surg ; 37(7): 442-450, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31265379

ABSTRACT

Objective: This study compared the effects of different surface treatments on the surface roughness (Ra), and shear bond strength (SBS) of resin cement to yttria-stabilized tetragonal zirconia (Y-TZP) ceramic and nickel-chromium (Ni-Cr) base metal alloy, respectively. Materials and methods: Thirty disk-shaped specimens (3 mm height and 10 mm diameter) of each material (Y-TZP and Ni-Cr) were prepared. Both zirconia and metal specimens were randomly assigned to three equal groups, according to the surface treatments (n = 10): sandblasting, sandblasting + Er:YAG laser, and sandblasting + Nd:YAG laser. Resin cement cylinders (4 mm diameter and 3 mm thickness) were placed on each specimen. The SBS tests were performed at a 1 mm per minute crosshead speed through a knife-edge rod after 5000 thermal cycles. The Ra (µm) of the specimens was measured using a profilometer and evaluated topographically by atomic force microscopy and scanning electron microscopy. Analysis of variance, followed by Tukey's honestly significant difference, in addition to the Kruskal-Wallis test, followed by the Mann-Whitney U test, were used for statistical analysis (α = 0.05). Results: Combined sandblasting and laser treatment of the metal groups led to statistically higher Ra values than sandblasting alone (p < 0.05). For Y-TZP, there were no significant differences between the Ra values of the subgroups (p > 0.05). The SBS of the sandblasted metal group was significantly higher than the other two laser-irradiated groups, whereas the SBS of sandblasted zirconia was only significantly higher than the Nd:YAG laser-irradiated group (p < 0.05). Conclusions: Combined laser and sandblasting surface treatments resulted in rougher surfaces than sandblasting alone, especially for the metal specimens. Sandblasting, alone, improved the SBS of resin cement in both metal and zirconia, compared with the laser and sandblasting treatments, combined.


Subject(s)
Chromium Alloys/chemistry , Dental Alloys/chemistry , Dental Bonding/methods , Dental Etching/methods , Dental Porcelain/chemistry , Lasers, Solid-State , Resin Cements/chemistry , Yttrium/chemistry , Zirconium/chemistry , Materials Testing , Microscopy, Atomic Force , Microscopy, Electron, Scanning , Shear Strength/radiation effects , Surface Properties
6.
Braz. oral res. (Online) ; 33: e053, 2019. tab, graf
Article in English | LILACS | ID: biblio-1019610

ABSTRACT

Abstract Self-adhesive resin cements (RCs) activate matrix metalloproteinase (MMP) and cathepsin-related collagen degradation, and gallic acid (GA) inhibits the activity of both MMPs and cysteine cathepsins. The purpose of this study was to evaluate the setting time, biaxial flexural strength, and Vickers hardness of self-adhesive RCs after the addition of two different concentrations of GA. RelyX U200 (3M ESPE) and Panavia SA (Kuraray) were modified with 0.5 and 1 wt% GA. The setting time of five samples in each RC group was assessed using a thermocouple apparatus as described in the ISO 4049 test. Biaxial flexure strength was measured using a universal testing machine until failure. Vickers hardness was measured with three randomized indentations on the surface of each resin disc. RCs without GA were used as control. Data were analyzed using a one-way analysis of variance and Tukey's HSD test (α = 0.05). The setting times ranged from 2.4 to 4.6 min for RelyX and from 4.9 to 6.0 min for Panavia. The biaxial flexure strength ranged from 76.5 to 109.7 MPa for RelyX and from 73.3 to 108.2 MPa for Panavia. Vickers hardness values ranged from 41.6 to 58.6 for RelyX and 27.2 to 33.6 for Panavia. The addition of 0.5 and 1 wt% GA to improve durability of resin-dentin bonds had no adverse effects on setting time, whereas the biaxial flexure strength and Vickers hardness values for the tested materials were significantly reduced.


Subject(s)
Resin Cements/chemistry , Gallic Acid/chemistry , Reference Values , Surface Properties , Time Factors , Materials Testing , Reproducibility of Results , Analysis of Variance , Statistics, Nonparametric , Matrix Metalloproteinases/chemistry , Flexural Strength , Hardness Tests
7.
J Istanb Univ Fac Dent ; 50(3): 57-61, 2016.
Article in English | MEDLINE | ID: mdl-28955577

ABSTRACT

The etiology of marginal bone loss around osseointegrated implants is primarily based on the biomechanical and/or microbial factors. If stresses and strains around dental implants under functional loading conditions are expected to exceed the physiologic tolerance thresholds of the alveolar bone, the fixed hybrid prosthesis might be a more reliable treatment of choice instead of fixed metal ceramic restorations. The purpose of this article is to report the 1-year follow-up of the periodontal and prosthetic rehabilitation of a patient who has presented with symptoms of peri-implantitis due to incorrectly planned implant supported fixed metal ceramic bridge which was later replaced with screw-retained hybrid prosthesis following the treatment of peri-implant defects. Treatment helped to maintain patient's self-confidence and comfort, as well as favorable masticatory function. Rehabilitation with screw retained hybrid prosthesis is an ideal treatment of choice for maxillomandibular skeletal discrepancies.

SELECTION OF CITATIONS
SEARCH DETAIL
...