Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Strahlenther Onkol ; 199(6): 565-573, 2023 06.
Article in English | MEDLINE | ID: mdl-36757424

ABSTRACT

PURPOSE: We report results of the first German prospective multicenter single-arm phase II trial (ARO 2013-06; NCT02635256) of hypofractionated robotic stereotactic body radiotherapy (SBRT) for patients with localized prostate cancer (HYPOSTAT). METHODS: Patients eligible for the HYPOSTAT study had localized prostate cancer (cT1­3 cN0 cM0), Gleason score ≤ 7, prostate-specific antigen (PSA) ≤ 15 ng/ml, prostate volume ≤ 80 cm3, and an International Prostate Symptom Score (IPSS) ≤ 12. Initially, inclusion was limited to patients ≥ 75 years or patients 70-74 years with additional risk factors. The trial protocol was later amended to allow for enrolment of patients aged ≥ 60 years. The treatment consisted of 35 Gy delivered in 5 fractions to the prostate and for intermediate- or high-risk patients, also to the proximal seminal vesicles using the CyberKnife system (Accuray Inc., Sunnyvale, CA, USA). Primary endpoint was the rate of treatment-related gastrointestinal or genitourinary grade ≥ 2 toxicity based on the RTOG scale 12-15 months after treatment. Secondary endpoints were acute toxicity, late toxicity, urinary function, quality of life, and PSA response. RESULTS: From July 2016 through December 2018, 85 eligible patients were enrolled and received treatment, of whom 83 could be evaluated regarding the primary endpoint. Patients mostly had intermediate-risk disease with a median PSA value of 7.97 ng/ml and Gleason score of 7a and 7b in 43.5% and 25.9% of patients, respectively. At the final follow-up 12-15 months after treatment, no patient suffered from treatment-related gastrointestinal or genitourinary grade ≥ 2 toxicity. Acute toxicity was mostly mild, with three grade 3 events, and the cumulative rate of grade ≥ 2 genitourinary toxicity was 8.4% (95% CI 4.1-16.4%). There were no major changes in urinary function or quality of life. The median PSA value dropped to 1.18 ng/ml 12-15 months after treatment. There was one patient who developed distant metastases. CONCLUSION: Robotic SBRT with 35 Gy in 5 fractions was associated with a favorable short-term toxicity profile. Recruitment for the HYPOSTAT­2 trial (ARO-2018­4; NCT03795337), which further analyses the late toxicity of this regimen with a planned sample size of 500 patients, is ongoing.


Subject(s)
Prostatic Neoplasms , Radiosurgery , Robotic Surgical Procedures , Male , Humans , Radiosurgery/methods , Prostate-Specific Antigen , Quality of Life , Prospective Studies , Prostatic Neoplasms/pathology
2.
ESC Heart Fail ; 7(3): 973-983, 2020 06.
Article in English | MEDLINE | ID: mdl-31991063

ABSTRACT

AIMS: Treating patients with acute decompensated heart failure (ADHF) presenting with volume overload is a common task. However, optimal guidance of decongesting therapy and treatment targets are not well defined. The inferior vena cava (IVC) diameter and its collapsibility can be used to estimate right atrial pressure, which is a measure of right-sided haemodynamic congestion. The CAVA-ADHF-DZHK10 trial is designed to test the hypothesis that ultrasound assessment of the IVC in addition to clinical assessment improves decongestion as compared with clinical assessment alone. METHODS AND RESULTS: CAVA-ADHF-DZHK10 is a randomized, controlled, patient-blinded, multicentre, parallel-group trial randomly assigning 388 patients with ADHF to either decongesting therapy guided by ultrasound assessment of the IVC in addition to clinical assessment or clinical assessment alone. IVC ultrasound will be performed daily between baseline and hospital discharge in all patients. However, ultrasound results will only be reported to treating physicians in the intervention group. Treatment target is relief of congestion-related signs and symptoms in both groups with the additional goal to reduce the IVC diameter ≤21 mm and increase IVC collapsibility >50% in the intervention group. The primary endpoint is change in N-terminal pro-brain natriuretic peptide from baseline to hospital discharge. Secondary endpoints evaluate feasibility, efficacy of decongestion on other scales, and the impact of the intervention on clinical endpoints. CONCLUSIONS: CAVA-ADHF-DZHK10 will investigate whether IVC ultrasound supplementing clinical assessment improves decongestion in patients admitted for ADHF.


Subject(s)
Heart Failure , Vena Cava, Inferior , Heart Failure/diagnosis , Heart Failure/therapy , Hemodynamics , Hospitalization , Humans , Ultrasonography , Vena Cava, Inferior/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...