Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Biomedicines ; 10(11)2022 Oct 24.
Article in English | MEDLINE | ID: mdl-36359205

ABSTRACT

BACKGROUND: The coefficient of friction (CoF) serves as an indicator for the mechanical properties of natural and regenerated articular cartilage (AC). After tribological exposure, a height loss (HL) of the cartilage pair specimens can be measured. Our aim was to determine the CoF and HL of regenerated AC tissue and compare them with those of natural AC from non-operated joints and AC from joints where the regenerated tissues had been created after different treatments. METHODS: In partial-thickness defects of the trochleae of the stifle joints of 60 Göttingen Minipigs, regenerated AC was created. In total, 40 animals received a Col I matrix, 20 laden with autologous chondrocytes, and 20 without. The defects of 20 animals were left empty. The healing periods were 24 and 48 weeks. A total of 10 not-operated animals, delivered the "external" control specimens. Osteochondral pins were harvested from defect and non-defect areas, the latter serving as "internal" controls. Using a pin-on-plate tribometer, we measured the CoF and the HL. RESULTS: The CoF of the regenerated AC ranged from 0.0393 to 0.0688, and the HL, from 0.22 mm to 0.3 mm. The differences between the regenerated AC of the six groups and the "external" controls were significant. The comparison with the "internal" controls revealed four significant differences for the CoF and one for the HL in the operated groups. No differences were seen within the operated groups. CONCLUSIONS: The mechanical quality of the regenerated AC tissue showed inferior behavior with regard to the CoF and HL in comparison with natural AC. The comparison of regenerated AC tissue with AC from untreated joints was more promising than with AC from the treated joints.

2.
PLoS One ; 16(4): e0250244, 2021.
Article in English | MEDLINE | ID: mdl-33891624

ABSTRACT

INTRODUCTION: We saw a lack of data on the biomechanical behavior of degenerated articular cartilage (OA) compared with that of healthy cartilage, even though the susceptibility to wear and tear of articular cartilage plays a key role in the progression of osteoarthritis (OA). Therefore, we performed a comparison between naturally occurring OA and healthy cartilage from pigs, before and after tribological stress. AIM: The aim of the study was to compare OA-cartilage with healthy cartilage and to analyze the resilience to tribological shear stress, which will be measured as height loss (HL), and to friction forces of the cartilage layers. The findings will be substantiated in macro- and microscopical evaluations before and after tribological exposure. METHODS: We assessed stifle joints of fifteen old and sixteen young pigs from the local abattoir radiologically, macroscopically and histologically to determine possible OA alterations. We put pins from the femoral part of the joints and plates from the corresponding tibial plateaus in a pin-on-plate tribometer under stress for about two hours with about 1108 reciprocating cycles under a pressure of approximately 1 MPa. As a surrogate criterion of wear and tear, the HL was recorded in the tribometer. The heights of the cartilage layers measured before and after the tribological exposure were compared histologically. The condition of the cartilage before and after the tribological exposure was analyzed both macroscopically with an adapted ICRS score and microscopically according to Little et al. (2010). We assessed the friction forces acting between the surfaces of the cartilage pair-specimens. RESULTS: Articular cartilage taken from old pigs showed significant degenerative changes compared to that taken from the young animals. The macroscopic and microscopic scores showed strong alterations of the cartilage after the tribological exposure. There was a noticeable HL of the cartilage specimens after the first 100 to 300 cycles. The HL after tribological exposure was lower in the group of the old animals with 0.52 mm ± 0.23 mm than in the group of the young animals with 0.86 mm ± 0.26 mm (p < 0.0001). The data for the HL was validated by the histological height measurements with 0.50 mm ± 0.82 mm for the old and 0.79 mm ±0.53 mm for the young animals (p = 0.133). The friction forces measured at the cartilage of the old animals were 2.25 N ± 1.15 N and 1.89 N ± 1.45 N of the young animals (p = 0.3225). CONCLUSION: Unlike articular cartilage from young pigs, articular cartilage from old pigs showed OA alterations. Tribological shear stress exposure revealed that OA cartilage showed less HL than healthy articular cartilage. Tribological stress exposure in a pin-on-plate tribometer seemed to be an appropriate way to analyze the mechanical stability of articular cartilage, and the applied protocol could reveal weaknesses of the assessed cartilage tissue. Friction and HL seemed to be independent parameters when degenerated and healthy articular cartilage were assessed under tribological exposure in a pin-on- plate tribometer.


Subject(s)
Cartilage, Articular/pathology , Knee Joint/pathology , Osteoarthritis/pathology , Aging , Animals , Biomechanical Phenomena , Bone Plates , Cartilage, Articular/diagnostic imaging , Friction , Knee Joint/diagnostic imaging , Osteoarthritis/diagnostic imaging , Swine
3.
Rev Sci Instrum ; 91(3): 034102, 2020 Mar 01.
Article in English | MEDLINE | ID: mdl-32259970

ABSTRACT

To examine coefficients of friction (COFs) of articular cartilage, it is necessary to use cartilage as a friction partner. Irregularities of surfaces require special tribometers and calculation methods. The aim of this study was to establish a tribometer system for measuring a low COF of cartilage and to develop and validate an algorithm that takes the irregularities into consideration. We used a pin-on-plate tribometer that allows a vertical displacement of the pin to follow the surface of the plate and developed an algorithm that takes these irregularities into account. We were, thus, able to take into consideration a forward and backward movement, an upward and downward movement, and different force ratios. The algorithm was validated using a spherical POM (polyoxymethylene) pin against a stainless steel plate at slope angles up to 24°. First examinations with articular cartilage against articular cartilage samples of a stifle joint of a pig were then performed. The newly developed tribometer worked well when POM against a stainless steel hump was examined. The COF increased for slope angles steeper than ±15°. There was an interaction between the COF and the slope angle, but not for the range within ±15°. Cartilage examinations revealed COFs as published in the literature. The tribometer and the algorithm were suitable for the detection of low COF of irregular surfaces of the plate within a range of ±15°. The COF resulting from the forward and backward movements should be averaged.


Subject(s)
Cartilage, Articular , Friction , Knee Joint , Stress, Mechanical , Animals , Surface Properties , Swine
4.
PLoS One ; 14(12): e0224996, 2019.
Article in English | MEDLINE | ID: mdl-31877143

ABSTRACT

The characterization of regenerated articular cartilage (AC) can be based on various methods, as there is an unambiguous accepted criterion neither for the natural cartilage tissue nor for regenerates. Biomechanical aspects should be considered as well, leading to the need for more equivalent samples. The aim of the study was to describe a large animal model where 8 specimens of regenerated AC can be created in one animal plus the impact of two surgeries on the welfare of the animals. The usefulness of the inclusion of a group of untreated animals (NAT) was to analyzed. Based on the histological results the conditions of the regenerates were to be described and the impact on knee joints were to be explored in terms of degenerative changes of the cartilage. The usefulness of the statistical term "effect size" (ES) will be explained with histological results. We analyzed an animal model where 8 AC regenerates were obtained from one Göttingen Minipig, on both sides of the trochleae. 60 animals were divided into 6 groups of 10 each, where the partial thickness defects in the trochlea were filled with matrices made of Collagen I with or without autologous chondrocytes or left empty over the healing periods of 24 and 48 weeks. One additional control group consisting of 10 untreated animals was used to provide untouched "external" cartilage. We harvested 560 samples of regenerated tissue and "external" controls, besides that, twice the number of further samples from other parts of the joints referred to as "internal" controls were also harvested. The animals recovered faster after the 1st operation when the defects were set compared to the 2nd operation when the defects were treated. 9% of all animals were lost. Other complications were for example superficial infections, seroma, diarrhea, febrile state and an injury of a claw. The histological results of the treatments proved the robustness of the study design where we included an "external" control group (NAT) in which the animals were not operated. Comparable significant differences between treated groups and the NAT group were detected both after ½ year and after 1 year. Spontaneous regenerated AC as control revealed differences after an observation time of nearly 1 year. The impact of the treatment on cartilage adjacent to the defect as well as the remaining knee joint was low. The ES was helpful for planning the study as it is shown that the power of a statistical comparison seems to be more influenced by the ES than by the sample size. The ranking of the ES was done exemplarily, listing the results according to their magnitude, thus making the results comparable. We were able to follow the 3 R requirements also in terms of a numerical reduction of animals due to the introduction of a group of untreated animals. This makes the model cost effective. The presented study may contribute as an improvement of the standardization of large animal models for research and regulatory requirements for regenerative therapies of AC.


Subject(s)
Cartilage, Articular/pathology , Chondrocytes/pathology , Knee Joint/pathology , Regeneration , Animals , Cartilage, Articular/surgery , Female , Knee Joint/surgery , Models, Animal , Swine , Swine, Miniature , Wound Healing
5.
J Orthop Surg Res ; 10: 117, 2015 Jul 28.
Article in English | MEDLINE | ID: mdl-26215154

ABSTRACT

BACKGROUND: Standardisation is required in research, so are approval procedures for advanced therapy medical products and other procedures for articular cartilage therapies. The process of creating samples needs to be reproducible. The aim of this study was to design, create and validate instruments (1) to create reproducible and accurate defects and (2) to isolate samples in the shape of osteochondral cylinders in a quick, reliable and sterile manner. METHODS: Adjustable instruments were created: a crown mill with a resolution of 0.05 mm and a front mill to create defects in articular cartilage and subchondral bone. The instruments were tested on knee joints of pigs from the slaughterhouse; 48 defects were created and evaluated. A punching machine was designed to harvest osteochondral plugs. These were validated in an in vivo animal study. RESULTS: The instruments respect the desired depth of 0.5 and 1.5 mm when creating the defects, depending on whether the person using the instrument is highly experienced (0.451 mm; confidence interval (CI): 0.390 mm; 0.512 mm and 1.403 mm; CI: 1.305 mm; 1.502 mm) or less so (0.369 mm; CI: 0.297 mm; 0.440 mm and 1.241 mm; CI: 1.141 mm; 1.341 mm). Eighty samples were taken from knee joints of Göttingen Minipigs with this punching technique. The time needed for the harvesting of the samples was 7.52 min (±2.18 min), the parallelism of the sides of the cylinders deviated by -0.63° (CI: -1.33°; 0.08°) and the surface of the cartilage deviated from the perpendicularity by 4.86° (CI: 4.154°; 5.573°). In all assessed cases, a sterile procedure was observed. CONCLUSIONS: Instruments and procedures for standardised creation and validation of defects in articular cartilage and subchondral bone were designed. Harvesting of samples in the shape of osteochondral cylinders can now be performed in a quick, reliable and sterile manner. The presented instruments and procedures can serve as helpful steps towards standardised operating procedures in the field of regenerative therapies of articular cartilage in research and for regulatory requirements.


Subject(s)
Cartilage, Articular/surgery , Knee Joint/surgery , Models, Animal , Surgical Instruments/standards , Animals , Bone Regeneration/physiology , Cartilage, Articular/pathology , Knee Joint/pathology , Swine , Swine, Miniature , Transplantation, Autologous/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...