Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Opt Express ; 6(12): 4812-24, 2015 Dec 01.
Article in English | MEDLINE | ID: mdl-26713196

ABSTRACT

X-ray grating interferometry requires gratings with periods in the micrometer range and allows the acquisition of the dark-field contrast. The analyzer grating is designed to match the period of the interference pattern in order to translate it into a measurable intensity modulation. In this study, we explore the influence of a sample-induced mismatch between the interference pattern and the analyzer grating on the dark-field contrast. We propose a formula for the calculation of the signal due to a period mismatch and present estimations varying periods and detector pixel size. Furthermore, numerical simulations of the X-ray wave-front demonstrate that the wave-front curvature, described by the lens-term, e.g. behind a parabolic lens or edges of a sample can change the period of the interference pattern. Our results give a concrete explanation for the formation of a dark-field contrast from object edges and thus allow a better understanding of the dark-field signal obtained with a grating interferometer.

2.
Biomed Opt Express ; 5(10): 3739-47, 2014 Oct 01.
Article in English | MEDLINE | ID: mdl-25360386

ABSTRACT

Numerical wave-optical simulations of X-ray differential phase-contrast imaging using grating interferometry require the oversampling of gratings and object structures in the range of few micrometers. Consequently, fields of view of few millimeters already use large amounts of a computer's main memory to store the propagating wave front, limiting the scope of the investigations to only small-scale problems. In this study, we apply an approximation to the Fresnel-Kirchhoff diffraction theory to overcome these restrictions by dividing the two-dimensional wave front up into 1D lines, which are processed separately. The approach enables simulations with samples of clinically relevant dimensions by significantly reducing the memory footprint and the execution time and, thus, allows the qualitative comparison of different setup configurations. We analyze advantages as well as limitations and present the simulation of a virtual mammography phantom of several centimeters of size.

3.
Opt Express ; 22(1): 547-56, 2014 Jan 13.
Article in English | MEDLINE | ID: mdl-24515015

ABSTRACT

X-ray imaging using a Talbot-Lau interferometer, consisting of three binary gratings, is a well-established approach to acquire x-ray phase-contrast and dark-field images with a polychromatic source. However, challenges in the production of high aspect ratio gratings limit the construction of a compact setup for high x-ray energies. In this study we consider the use of phase gratings with triangular-shaped structures in an x-ray interferometer and show that such gratings can yield high visibilities for significantly shorter propagation distances than conventional gratings with binary structures. The findings are supported by simulation and experimental results for both cases of a monochromatic and a polychromatic source.


Subject(s)
Interferometry/instrumentation , Lighting/instrumentation , Refractometry/instrumentation , X-Ray Diffraction/instrumentation , Computer Simulation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Models, Theoretical
4.
Respir Res ; 7: 86, 2006 Jun 06.
Article in English | MEDLINE | ID: mdl-16756655

ABSTRACT

BACKGROUND: Surfactant dysfunction due to inhibition is involved in the pathophysiology of meconium aspiration syndrome. Dextran addition has been shown to reverse exogenous surfactant inactivation by meconium, but the precise mechanisms and the morphological correlate of this effect are yet unknown. Morphological surfactant analysis by transmission electron microscopy (TEM) and stereology allows the differentiation of active (large aggregates = LA) and inactive (small aggregates = SA) subtypes. METHODS: To determine the in vitro effects of meconium and dextran addition on the morphology of a modified porcine natural surfactant (Curosurf), Curosurf samples were either incubated alone or together with meconium or with meconium and dextran, fixed and processed for TEM. Volume fractions of surfactant subtypes [lamellar body-like forms (LBL), multilamellar vesicles (MV), unilamellar vesicles (UV)] were determined stereologically. RESULTS: All preparations contained LBL and MV (corresponding to LA) as well as UV (corresponding to SA). The volume fraction of UV increased with addition of meconium and decreased with further addition of dextran. Correspondingly, the UV/(LBL+MV) ratio (resembling the SA/LA ratio) increased when meconium was added and decreased when dextran was added to the surfactant-meconium mixture. CONCLUSION: Meconium causes alterations in the ultrastructural composition of Curosurf that can be visualized and analyzed by TEM and stereology. These alterations resemble an increase in the SA/LA ratio and are paralleled by an increase in minimum surface tension. Dextran prevents these effects and may therefore be a useful additive to exogenous surfactant preparations to preserve their structural and functional integrity, thereby improving their resistance to inactivation.


Subject(s)
Biological Products/chemistry , Dextrans/chemistry , Meconium/chemistry , Phospholipids/chemistry , Pulmonary Surfactants/chemistry , Dextrans/pharmacology , Humans , Infant, Newborn , Microscopy, Electron, Transmission , Pulmonary Surfactants/antagonists & inhibitors , Surface Tension
SELECTION OF CITATIONS
SEARCH DETAIL
...