Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Health Phys ; 104(4): 366-78, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23439140

ABSTRACT

A new modification of the prior human lung compartment plutonium model, Doses-2005, has been described. The modified model was named "Mayak Worker Dosimetry System-2008" (MWDS-2008). In contrast to earlier models developed for workers at the Mayak Production Association (Mayak PA), the new model more correctly describes plutonium biokinetics and metabolism in pulmonary lymph nodes. The MWDS-2008 also provides two sets of doses estimates: one based on bioassay data and the other based on autopsy data, where available. The algorithm of internal dose calculation from autopsy data will be described in a separate paper. Results of comparative analyses of Doses-2005 and MWDS-2008 are provided. Perspectives on the further development of plutonium dosimetry are discussed.


Subject(s)
Lung/metabolism , Lymph Nodes/metabolism , Models, Biological , Occupational Exposure/adverse effects , Plutonium/urine , Power Plants , Radiation Monitoring , Autopsy , Biological Assay , Female , Humans , Lung/radiation effects , Lymph Nodes/radiation effects , Male , Plutonium/pharmacokinetics , Tissue Distribution
2.
Health Phys ; 99(4): 560-7, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20838099

ABSTRACT

Plutonium isotopes (239Pu and 238Pu, and 241Am) with a total activity of 269 kBq were accidentally deposited in a puncture wound of the right index finger of a nuclear worker at the Mayak Production Association. Tissues surrounding the wound site contaminated with radionuclides were excised 4.5 h after the injury. Residual contamination within the wound amounted to 0.05% of the initial contamination. The 10-d therapy with CaNa3-diethylene triamine pentaacetate acid (CaNa3-DTPA) was performed in parallel with in vivo measurements of the wound site and daily urine bioassays. The wound intake of radionuclides was consistent with two forms of radioactive materials detected within the wound site, i.e., soluble compounds and a large fragment, which was completely removed by excision. On day 9 after the injury, the clearance rate from the wound site was 1.8 times higher than the rate predicted by the National Council on Radiation Protection and Measurements (NCRP) model for soluble compounds of plutonium and americium. The NCRP model parameters of transfer rates from the colloid and intermediate state (CIS) into soluble, and particles, aggregates and bound state (PABS) compartments were modified to eliminate any difference. As a result, a difference between the observed wound site radionuclide content and the value predicted by the modified wound model did not exceed 14% up to 9 days after the injury. For a longer period from 7 to 24 months, the value predicted by the modified model was consistent with results of the corresponding in vivo measurements. The treatment reduced the effective dose (50 years) from internal exposure by at least 480 times. The dose estimated (without accounting for a contribution of exposure dose to the regional lymph nodes draining the wound site) did not exceed 11 mSv.


Subject(s)
Americium/pharmacokinetics , Models, Biological , Occupational Exposure/analysis , Pentetic Acid/pharmacology , Plutonium/pharmacokinetics , Radiation Injuries/metabolism , Wounds, Penetrating/metabolism , Americium/analysis , Decontamination , Fingers/surgery , Humans , Injections, Intravenous , Lymph Nodes/drug effects , Lymph Nodes/metabolism , Male , Middle Aged , Nuclear Power Plants , Pentetic Acid/administration & dosage , Plutonium/analysis , Radiation Injuries/prevention & control , Radiation Injuries/surgery , Radiation-Protective Agents/administration & dosage , Radiation-Protective Agents/pharmacology , Russia , Time Factors , Treatment Outcome , Wounds, Penetrating/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...