Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
1.
Article in English | MEDLINE | ID: mdl-38762034

ABSTRACT

OBJECTIVES: Although cardiogenic shock requiring extracorporeal life support after cardiac surgery is associated with high mortality, the impact of sex on outcomes of postcardiotomy extracorporeal life support remains unclear with conflicting results in the literature. We compare patient characteristics, in-hospital outcomes, and overall survival between females and males requiring postcardiotomy extracorporeal life support. METHODS: This retrospective, multicenter (34 centers), observational study included adults requiring postcardiotomy extracorporeal life support between 2000 and 2020. Preoperative, procedural, and extracorporeal life support characteristics, complications, and survival were compared between females and males. Association between sex and in-hospital survival was investigated through mixed Cox proportional hazard models. RESULTS: This analysis included 1823 patients (female: 40.8%; median age: 66.0 years [interquartile range, 56.2-73.0 years]). Females underwent more mitral valve surgery (females: 38.4%, males: 33.1%, P = .019) and tricuspid valve surgery (feamales: 18%, males: 12.4%, P < .001), whereas males underwent more coronary artery surgery (females: 45.9%, males: 52.4%, P = .007). Extracorporeal life support implantation was more common intraoperatively in feamales (females: 64.1%, females: 59.1%) and postoperatively in males (females: 35.9%, males: 40.9%, P = .036). Ventricular unloading (females: 25.1%, males: 36.2%, P < .001) and intra-aortic balloon pumps (females: 25.8%, males: 36.8%, P < .001) were most frequently used in males. Females had more postoperative right ventricular failure (females: 24.1%, males: 19.1%, P = .016) and limb ischemia (females: 12.3%, males: 8.8%, P = .23). In-hospital mortality was 64.9% in females and 61.9% in males (P = .199) with no differences in 5-year survival (females: 20%, 95% CI, 17-23; males: 24%, 95% CI, 21-28; P = .069). Crude hazard ratio for in-hospital mortality in females was 1.12 (95% CI, 0.99-1.27; P = .069) and did not change after adjustments. CONCLUSIONS: This study demonstrates that female and male patients requiring postcardiotomy extracorporeal life support have different preoperative and extracorporeal life support characteristics, as well as complications, without a statistical difference in in-hospital and 5-year survivals.

3.
J Heart Lung Transplant ; 43(2): 251-260, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37769887

ABSTRACT

PURPOSE: The HeartMate 3 (HM3) left ventricular assist device (LVAD) has demonstrated excellent clinical outcomes; however, pump speed optimization is challenging with the available HM3 monitoring. Therefore, this study reports on clinical HM3 parameters collected with a noninvasive HM3 monitoring system (HM3 Snoopy) during echocardiographic speed ramp tests and Valsalva maneuvers. METHODS: In this prospective, single-center study, the HM3 data communication between the controller and pump was recorded with a novel data acquisition system. Twelve pump parameters sampled every second (1 Hz) and clinical assessments (echocardiography, electrocardiogram (ECG), and blood pressure measurement) during speed ramp tests were analyzed using Pearson's correlation (r, median [IQR]). The cause for the occurrence of pulsatility index (PI)-events during ramp speed tests and valsalva maneuvers was investigated. RESULTS: In 24 patients (age: 58.9 ± 8.8 years, body mass index: 28.1 ± 5.1 kg/m2, female: 20.8%), 35 speed ramp tests were performed with speed changes in the range of ±1000 rpm from a baseline speed of 5443 ± 244 rpm. Eight HM3 pump parameters from estimated flow, motor current, and LVAD speed together with blood pressure showed positive collinearities (r = 0.9 [0.1]). Negative collinearities were observed for pump flow pulsatility, pulsatility index, rotor noise, and left ventricular diameters (r = -0.8 [0.1]), whereas rotor displacement and heartrate showed absence of collinearities (r = -0.1 [0.08]). CONCLUSIONS: In this study, the HM3 Snoopy was successfully used to acquire more parameters from the HM3 at a higher sampling rate. Analysis of HM3 per-second data provide additional clinical diagnostic information on heart-pump interactions and cause of PI-events.


Subject(s)
Heart Failure , Heart-Assist Devices , Humans , Female , Middle Aged , Aged , Prospective Studies , Valsalva Maneuver , Echocardiography , Heart-Assist Devices/adverse effects
4.
Ann Thorac Surg ; 116(5): 1079-1089, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37414384

ABSTRACT

BACKGROUND: Postcardiotomy venoarterial extracorporeal membrane oxygenation (VA ECMO) is characterized by discrepancies between weaning and survival-to-discharge rates. This study analyzes the differences between postcardiotomy VA ECMO patients who survived, died on ECMO, or died after ECMO weaning. Causes of death and variables associated with mortality at different time points are investigated. METHODS: The retrospective, multicenter, observational Postcardiotomy Extracorporeal Life Support Study (PELS) includes adults requiring postcardiotomy VA ECMO between 2000 and 2020. Variables associated with on-ECMO mortality and postweaning mortality were modeled using mixed Cox proportional hazards, including random effects for center and year. RESULTS: In 2058 patients (men, 59%; median age, 65 years; interquartile range [IQR], 55-72 years), weaning rate was 62.7%, and survival to discharge was 39.6%. Patients who died (n = 1244) included 754 on-ECMO deaths (36.6%; median support time, 79 hours; IQR, 24-192 hours), and 476 postweaning deaths (23.1%; median support time, 146 hours; IQR, 96-235.5 hours). Multiorgan (n = 431 of 1158 [37.2%]) and persistent heart failure (n = 423 of 1158 [36.5%]) were the main causes of death, followed by bleeding (n = 56 of 754 [7.4%]) for on-ECMO mortality and sepsis (n = 61 of 401 [15.4%]) for postweaning mortality. On-ECMO death was associated with emergency surgery, preoperative cardiac arrest, cardiogenic shock, right ventricular failure, cardiopulmonary bypass time, and ECMO implantation timing. Diabetes, postoperative bleeding, cardiac arrest, bowel ischemia, acute kidney injury, and septic shock were associated with postweaning mortality. CONCLUSIONS: A discrepancy exists between weaning and discharge rate in postcardiotomy ECMO. Deaths occurred during ECMO support in 36.6% of patients, mostly associated with unstable preoperative hemodynamics. Another 23.1% of patients died after weaning in association with severe complications. This underscores the importance of postweaning care for postcardiotomy VA ECMO patients.

5.
Eur J Cardiothorac Surg ; 63(4)2023 04 03.
Article in English | MEDLINE | ID: mdl-36825836

ABSTRACT

OBJECTIVES: Haemorrhagic and thrombotic complications are known obstacles in extracorporeal life support (ECLS), and patients requiring post-cardiotomy (PC)-ECLS are particularly prone. The objective of this study was to characterize the incidence, type and clinical relevance of bleeding and thrombotic events in patients on PC-ECLS. METHODS: A total of 504 patients receiving PC-ECLS between 2000 and 2021 at a single centre were included in a retrospective analysis. Incidence and type of haemorrhagic and thrombotic complications in patients on PC-ECLS were assessed. Overall survival was compared, and perioperative risk factors for bleeding and thrombotic events were assessed by binary logistic regression. RESULTS: Of the 504 patients requiring PC-ECLS, 196 patients (38.9%) had 235 bleeding events [surgical site: n = 135 (26.8%); cannulation site: n = 68(13.4%); requiring surgical revision: n = 39 (7.7%); cannulation site change: n = 17 (3.4%); fatal cannulation site bleeding: n = 4(0.8%); intracranial haemorrhage: n = 11 (2.1%); gastrointestinal haemorrhage: n = 8 (1.6%); pulmonary haemorrhage: n = 8 (1.6%); and intra-abdominal/retroperitoneal haemorrhage: n = 5 (1%)]. Overall mortality was higher in patients with major bleeding complications than in patients without bleeding complications (P < 0.0001).A total of 74 patients (14.7%) had 84 thrombotic events [ischaemic stroke, n = 39 (7.7%); cannula/circuit thrombosis, n = 26 (5.2%); peripheral embolism, n = 11 (2.2%); device exchange for haemolysis, n = 8 (1.6%)]. Another 246 patients (48.8%) had at least 1 haemocompatibility-related adverse event. Preoperative dual antiplatelet therapy [adjusted odds ratio (OR): 1.83, 95% confidence interval (CI): 1.063-3.137] and ECLS duration (adjusted OR: 1.14, 95% CI: 1.086-1.197) were identified as independent risk factors for haemorrhage. Prior stroke/transient ischaemic attack (adjusted OR: 1.91, 95% CI: 1.08-3.83) and ECLS duration (adjusted OR: 1.09, 95% CI: 1.04-1.15) were identified as risk factors for thrombotic events. CONCLUSIONS: Bleeding complications in patients on ECLS are common and significantly impair survival. Nearly half of the patients were affected by any haemocompatibility-related event.


Subject(s)
Brain Ischemia , Extracorporeal Membrane Oxygenation , Stroke , Thrombosis , Humans , Extracorporeal Membrane Oxygenation/adverse effects , Retrospective Studies , Brain Ischemia/etiology , Stroke/etiology , Hemorrhage/epidemiology , Hemorrhage/etiology , Thrombosis/epidemiology , Thrombosis/etiology
6.
Int J Mol Sci ; 23(24)2022 Dec 07.
Article in English | MEDLINE | ID: mdl-36555139

ABSTRACT

Thoracic aortic aneurysm (TAA) is an age-related and life-threatening vascular disease. Telomere shortening is a predictor of age-related diseases, and its progression is associated with premature vascular disease. The aim of the present work was to investigate the impacts of chronic hypoxia and telomeric DNA damage on cellular homeostasis and vascular degeneration of TAA. We analyzed healthy and aortic aneurysm specimens (215 samples) for telomere length (TL), chronic DNA damage, and resulting changes in cellular homeostasis, focusing on senescence and apoptosis. Compared with healthy thoracic aorta (HTA), patients with tricuspid aortic valve (TAV) showed telomere shortening with increasing TAA size, in contrast to genetically predisposed bicuspid aortic valve (BAV). In addition, TL was associated with chronic hypoxia and telomeric DNA damage and with the induction of senescence-associated secretory phenotype (SASP). TAA-TAV specimens showed a significant difference in SASP-marker expression of IL-6, NF-κB, mTOR, and cell-cycle regulators (γH2AX, Rb, p53, p21), compared to HTA and TAA-BAV. Furthermore, we observed an increase in CD163+ macrophages and a correlation between hypoxic DNA damage and the number of aortic telocytes. We conclude that chronic hypoxia is associated with telomeric DNA damage and the induction of SASP in a diseased aortic wall, promising a new therapeutic target.


Subject(s)
Aortic Aneurysm, Thoracic , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Humans , Heart Valve Diseases/metabolism , Senescence-Associated Secretory Phenotype , Aortic Aneurysm, Thoracic/genetics , Aortic Aneurysm, Thoracic/complications , Aortic Valve/metabolism
8.
J Heart Lung Transplant ; 41(12): 1850-1857, 2022 12.
Article in English | MEDLINE | ID: mdl-36137868

ABSTRACT

BACKGROUND: The use of polytetrafluoroethylene (PTFE) material as a protective cover for left ventricular assist device (LVAD) outflow grafts (OG) is a common practice. However, it has descriptively been linked to the development of blood flow obstruction (BFO). METHODS: Patient data from 194 consecutive HVAD (Medtronic Inc; Medtronic, Minneapolis, MN) recipients implanted between March 2006 and January 2021 were retrospectively analyzed. PTFE covers were used in 102 patients. Study outcomes included the incidence of BFO and survival on LVAD support. RESULTS: Thirty-seven patients (19.1%) developed BFO during the study period. On a multivariable Cox regression analysis, PTFE use was an independent predictor for the development of BFO (HR 2.15, 95% CI 1.03-4.48, p = .04). BFO comprised of 2 types of device malfunction: eleven patients (5.7%) developed outflow graft stenosis (OGS), and 31 patients (16.0%) developed pump thrombosis (PT). There was a significantly higher cumulative incidence of OGS in patients with PTFE cover than in those without (Gray's test, p =.03). However, the observed higher cumulative incidence of PT in PTFE patients was non-significant (Gray's test, p =.06). In a multivariable Cox regression model, the effect of PTFE use on survival was non-significant (HR 0.95, 95% CI 0.60-1.48, p =.81), while the development of BFO was independently associated with increased mortality (HR 3.43, 95% CI 1.94-6.06, p < .0001). CONCLUSIONS: The use of PTFE OG cover in LVAD patients is associated with an increased cumulative probability of development of BFO, the latter adversely impacting survival and is therefore, harmful.


Subject(s)
Heart-Assist Devices , Thrombosis , Humans , Heart-Assist Devices/adverse effects , Polytetrafluoroethylene , Retrospective Studies , Thrombosis/epidemiology , Thrombosis/etiology , Thrombosis/prevention & control , Incidence
9.
Front Cardiovasc Med ; 9: 888269, 2022.
Article in English | MEDLINE | ID: mdl-35548436

ABSTRACT

Background: Contemporary Left Ventricular Assist Devices (LVADs) mainly operate at a constant speed, only insufficiently adapting to changes in patient demand. Automatic physiological speed control promises tighter integration of the LVAD into patient physiology, increasing the level of support during activity and decreasing support when it is excessive. Methods: A sensorless modular control algorithm was developed for a centrifugal LVAD (HVAD, Medtronic plc, MN, USA). It consists of a heart rate-, a pulsatility-, a suction reaction-and a supervisor module. These modules were embedded into a safe testing environment and investigated in a single-center, blinded, crossover, clinical pilot trial (clinicaltrials.gov, NCT04786236). Patients completed a protocol consisting of orthostatic changes, Valsalva maneuver and submaximal bicycle ergometry in constant speed and physiological control mode in randomized sequence. Endpoints for the study were reduction of suction burden, adequate pump speed and flowrate adaptations of the control algorithm for each protocol item and no necessity for intervention via the hardware safety systems. Results: A total of six patients (median age 53.5, 100% male) completed 13 tests in the intermediate care unit or in an outpatient setting, without necessity for intervention during control mode operation. Physiological control reduced speed and flowrate during patient rest, in sitting by a median of -75 [Interquartile Range (IQR): -137, 65] rpm and in supine position by -130 [-150, 30] rpm, thereby reducing suction burden in scenarios prone to overpumping in most tests [0 [-10, 2] Suction events/minute] in orthostatic upwards transitions and by -2 [-6, 0] Suction events/min in Valsalva maneuver. During submaximal ergometry speed was increased by 86 [31, 193] rpm compared to constant speed for a median flow increase of 0.2 [0.1, 0.8] L/min. In 3 tests speed could not be increased above constant set speed due to recurring suction and in 3 tests speed could be increased by up to 500 rpm with a pump flowrate increase of up to 0.9 L/min. Conclusion: In this pilot study, safety, short-term efficacy, and physiological responsiveness of a sensorless automated speed control system for a centrifugal LVAD was established. Long term studies are needed to show improved clinical outcomes. Clinical Trial Registration: ClinicalTrials.gov, identifier: NCT04786236.

10.
Transpl Int ; 35: 10057, 2022.
Article in English | MEDLINE | ID: mdl-35497886

ABSTRACT

Objectives: Cold ischemia and subsequent reperfusion injury are non-immunologic cornerstones in the development of graft injury after heart transplantation. The nitric oxide donor S-nitroso-human-serum-albumin (S-NO-HSA) is known to attenuate myocardial ischemia-reperfusion (I/R)-injury. We assessed whether donor preservation with S-NO-HSA affects isograft injury and myocardial expression of GATA2 as well as miR-126-3p, which are considered protective against vascular and endothelial injury. Methods: Donor C57BL/6 mice received intravenous (0.1 µmol/kg/h) S-NO-HSA (n = 12), or 0.9% saline (control, n = 11) for 20 min. Donor hearts were stored in cold histidine-tryptophan-α-ketoglutarate-N solution for 12 h and underwent heterotopic, isogenic transplantation, except 5 hearts of each group, which were analysed immediately after preservation. Fibrosis was quantified and expression of GATA2 and miR-126-3p assessed by RT-qPCR after 60 days or immediately after preservation. Results: Fibrosis was significantly reduced in the S-NO-HSA group (6.47% ± 1.76 vs. 11.52% ± 2.16; p = 0.0023; 12 h-S-NO-HSA-hHTX vs. 12 h-control-hHTX). Expression of miR-126-3p was downregulated in all hearts after ischemia compared to native myocardium, but the effect was significantly attenuated when donors received S-NO-HSA (1 ± 0.27 vs. 0.33 ± 0.31; p = 0.0187; 12 h-S-NO-HSA-hHTX vs. 12 h-control-hHTX; normalized expression to U6 snRNA). Conclusion: Donor pre-treatment with S-NO-HSA lead to reduced fibrosis and preservation of myocardial miR-126-3p and GATA2 levels in murine cardiac isografts 60 days after transplantation.


Subject(s)
Heart Transplantation , MicroRNAs , Animals , Fibrosis , Humans , Isografts , Mice , Mice, Inbred C57BL , Myocardium , Serum Albumin, Human , Tissue Donors
11.
Life (Basel) ; 12(3)2022 Mar 20.
Article in English | MEDLINE | ID: mdl-35330210

ABSTRACT

Right heart failure (RHF) is a severe complication after left ventricular assist device (LVAD) implantation. The aim of this study was to analyze the incidence, risk factors, and biomarkers for late RHF including the possible superiority of the device and implantation method. This retrospective, single-center study included patients who underwent LVAD implantation between 2014 and 2018. Primary outcome was freedom from RHF over one-year after LVAD implantation; secondary outcomes included pre- and postoperative risk factors and biomarkers for RHF. Of the 145 consecutive patients (HeartMate 3/HVAD: n = 70/75; female: 13.8%), thirty-one patients (21.4%) suffered RHF after a mean LVAD support of median (IQR) 105 (118) days. LVAD implantation method (less invasive: 46.7% vs. 35.1%, p = 0.29) did not differ significantly in patients with or without RHF, whereas the incidence of RHF was lower in HeartMate 3 vs. HVAD patients (12.9% vs. 29.3%, p = 0.016). Multivariate Cox proportional hazard analysis identified HVAD (HR 4.61, 95% CI 1.12-18.98; p = 0.03), early post-op heart rate (HR 0.96, 95% CI 0.93-0.99; p = 0.02), and central venous pressure (CVP) (HR 1.21, 95% CI 1.05-1.39; p = 0.01) as independent risk factors for RHF, but no association of RHF with increased all-cause mortality (HR 1.00, 95% CI 0.99-1.01; p = 0.50) was found. To conclude, HVAD use, lower heart rate, and higher CVP early post-op were independent risk factors for RHF following LVAD implantation.

12.
Interact Cardiovasc Thorac Surg ; 34(5): 841-848, 2022 05 02.
Article in English | MEDLINE | ID: mdl-35137102

ABSTRACT

OBJECTIVES: Up-regulation of tenascin C (TNC), a matricellular protein, produced mainly by vascular smooth muscle cells (VSMC), is associated with the progression and dilation of abdominal aortic aneurysms (AAA). The aims of this study were (i) to evaluate whether serum levels of TNC in patients with AAA patients correlate with aortic diameter and (ii) to clarify the role of TNC in formation and progression of AAA in a murine model. METHODS: In 15 patients with AAA serum levels of TNC were measured and correlated with aortic diameters. Moreover, in a murine calcium chloride AAA model, the impact of TNC deficiency on AAA diameter was evaluated. Finally, human VSMC were incubated with TNC to clarify its regulating potential. RESULTS: In the clinical cohort, there was a trend of correlation between serum TNC levels and AAA diameter (P = 0.055). TNC knock out mice with AAA showed significantly lower diameter ratios compared to the wild-type group (WT) 3 weeks (P < 0.05) and 10 weeks (P < 0.05) after AAA induction. Immunohistochemistry revealed increased TNC expression in aortic tissue from WT with AAA as compared sham-operated mice. Furthermore, WT with AAA showed a more disrupted Elastin structure than TNC knock out mice 10 weeks after AAA induction. In human aortic VSMC, TNC incubation induced expression of remodelling associated proteins. CONCLUSIONS: TNC might play a causative role in the formation, dilation and progression of AAA. Our results indicate that TNC might be a biomarker as well as a potential therapeutic target in the treatment of AAA.


Subject(s)
Aortic Aneurysm, Abdominal , Animals , Aorta, Abdominal , Disease Models, Animal , Humans , Mice , Mice, Inbred C57BL , Mice, Knockout , Tenascin/metabolism
13.
Eur J Cardiothorac Surg ; 61(5): 1178-1185, 2022 05 02.
Article in English | MEDLINE | ID: mdl-35092269

ABSTRACT

OBJECTIVES: Although post-cardiotomy extracorporeal life support (PC-ECLS) is a potentially life-saving resource for patients with cardiopulmonary failure after cardiac surgery, adverse outcomes have been reported even in successfully weaned patients. The goal of this study was to assess outcome in patients weaned from PC-ECLS. METHODS: Of 573 consecutive patients who received PC-ECLS at a single centre between 2000 and 2019, 478 patients were included in a retrospective analysis. Successful weaning was defined as survival >24 h after extracorporeal life support (ECLS) explantation. Mortality of patients on ECLS, as well as in-hospital mortality of weaned patients, was assessed. A binary logistic regression model with backward elimination was used to identify predictors for in-hospital mortality after successful ECLS explantation. RESULTS: Of 478 included patients, 120 patients (25.1%) died on ECLS or within 24 h after ECLS explantation. A total of 358 patients were successfully separated from ECLS and survived for >24 h (n = 352 weaned, n = 3 transitioned to durable left ventricular assist device and n = 3 transitioned to a heart transplant). A total of 35.5% of patients who were successfully weaned from ECLS did not survive until hospital discharge. In-hospital deaths of the whole cohort were 51.7% (247/478 patients). For patients who survived to discharge (231/478 patients, 48.3%), survival was 87% after 1 year and 68.9% after 5 years. CONCLUSIONS: In-hospital mortality of patients requiring PC-ECLS is high even in case of successful weaning. Longer ECLS duration, older age, female gender and low preoperative glomerular filtration rate were risk factors for in-hospital mortality after ECLS weaning. Survival of patients discharged after PC-ECLS was encouraging.


Subject(s)
Cardiac Surgical Procedures , Extracorporeal Membrane Oxygenation , Heart Transplantation , Heart-Assist Devices , Cardiac Surgical Procedures/adverse effects , Extracorporeal Membrane Oxygenation/adverse effects , Female , Humans , Retrospective Studies , Treatment Outcome
14.
Eur J Cardiothorac Surg ; 61(3): 716-724, 2022 Feb 18.
Article in English | MEDLINE | ID: mdl-34468714

ABSTRACT

OBJECTIVES: We reviewed our institutional experience with outflow graft stenosis (OGS) in 3 contemporary left ventricular assist devices (LVAD). METHODS: Data from 347 consecutive adult recipients of LVAD [Medtronic HVAD (n = 184, 53.0%), Abbott HeartMate II (n = 62, 17.9%) and Abbott HeartMate 3 (n = 101, 29.1%)] implanted between March 2006 and October 2019 were analysed retrospectively. Primary study end points were the incidence of OGS necessitating treatment and survival on LVAD support. RESULTS: During the study period, 17 patients (4.9%) developed OGS requiring treatment with a probability of 0.6% at 1 year, 1.9% at 2 years, 3.8% at 3 years, 4.7% at 4 years and 5.9% at 5 years of LVAD support. Notably, in 13.8% of patients, a compression-related narrowing of the outflow graft with a probability of 1.5% at 6 months, 1.8% 1 year, 6.0% at 2 years, 12.3% at 3 years, 15.4% at 4 years and 16.6% at 5 years of LVAD support with no difference between devices (P = 0.26) was observed. There was a trend towards increased risk of mortality with OGS (hazard ratio 2.21, 95% confidence interval 0.87-5.51; P = 0.09). OGS preferentially occurred in segments of the outflow graft covered by a protective coating. CONCLUSIONS: OGS is a rare but potentially lethal complication during LVAD support. Modifications of pump design and implant techniques may be needed because OGS preferentially occurs within covered portions of the outflow graft. Systematic screening may be warranted.


Subject(s)
Heart Failure , Heart-Assist Devices , Adult , Constriction, Pathologic/etiology , Heart Failure/etiology , Heart Failure/surgery , Heart-Assist Devices/adverse effects , Humans , Incidence , Retrospective Studies
15.
J Thorac Cardiovasc Surg ; 164(5): 1546-1558.e8, 2022 11.
Article in English | MEDLINE | ID: mdl-34949456

ABSTRACT

OBJECTIVE: To assess the influence of primary arterial access in patients receiving peripheral postcardiotomy extracorporeal life support on associated complications and outcome. METHODS: Of 573 consecutive patients requiring PC-ECLS between 2000 and 2019 at a single center, 436 were included in a retrospective analysis and grouped according to primary arterial extracorporeal life support access site. Survival and rate of access-site-related complications with special emphasis on fatal/disabling stroke were compared. RESULTS: The axillary artery was cannulated in 250 patients (57.3%), whereas the femoral artery was used as primary arterial access in 186 patients (42.6%). There was no significant difference in 30-day (axillary: 62%; femoral: 64.7%; P = .561) and 1-year survival (axillary: 42.5%; femoral: 44.8%; P = .657). Cerebral computed tomography-confirmed stroke with a modified ranking scale ≥4 was significantly more frequent in the axillary group (axillary: n = 28, 11.2%; femoral: n = 4, 2.2%; P = .0003). Stroke localization was right hemispheric (n = 20; 62.5%); left hemispheric (n = 5; 15.6%), bilateral (n = 5; 15.6%), or infratentorial (n = 2; 6.25%). Although no difference in major cannulation site bleeding was observed, cannulation site change for bleeding was more frequent in the axillary group (axillary: n = 13; 5.2%; femoral: n = 2; 1.1%; P = .03). Clinically apparent limb ischemia was significantly more frequent in the femoral group (axillary: n = 12, 4.8%; femoral: n = 31, 16.7%; P < .0001). CONCLUSIONS: Although survival did not differ, surgeons should be aware of access-site-specific complications when choosing peripheral PC-ECLS access. Although lower rates of limb ischemia and the advantage of antegrade flow seem beneficial for axillary cannulation, the high incidence of right hemispheric strokes in axillary artery cannulation should be considered.


Subject(s)
Catheterization, Peripheral , Extracorporeal Membrane Oxygenation , Stroke , Catheterization, Peripheral/adverse effects , Extracorporeal Membrane Oxygenation/adverse effects , Femoral Artery/diagnostic imaging , Humans , Ischemia/etiology , Retrospective Studies , Stroke/etiology
16.
Life (Basel) ; 11(9)2021 Sep 05.
Article in English | MEDLINE | ID: mdl-34575071

ABSTRACT

Several risk scores and classifications are available to predict peri- and post-operative mortality of patients with end stage heart failure receiving Left Ventricular Assist Device (LVAD) therapy. Sarcopenia has been suggested as a sensitive predictor for post-operative mortality. We evaluated whether the psoas muscle area can predict mortality in patients undergoing LVAD implantation. The indexed psoas mean area (PMAi) was obtained by measuring the psoas muscle area at the superior endplate of the third lumbar vertebra correlated to body surface area of 106 adult patients undergoing LVAD implantation (Medtronic HVAD n = 41, Abbott HeartMate II n = 4, Abbott HeartMate 3 n = 61; mean age 65, IQR 12, 90.6% male; INTERMACS Level 1 24.5%; ischemic CMP 64.2%). Patients were divided in two groups: high/moderate and low muscle mass. The primary endpoint was 30-day mortality, assessed using a multivariate Cox proportional hazards model. Baseline characteristics did not differ between patients with high or moderate and low PMAi. Estimated survival calculated a significant higher 30-day mortality in patients with low PMAi (p = 0.04). Multivariable Cox proportional hazards regression analysis indicated low PMAi, history of previous cardiac surgery and levels of bilirubin as independent predictors of mortality in the first 30 days. In conclusion, indexed psoas muscle area predicts mortality after LVAD implantation and can be used as an additional tool for risk stratification.

17.
Biomolecules ; 11(5)2021 05 17.
Article in English | MEDLINE | ID: mdl-34067880

ABSTRACT

(1) Alkaline phosphatase (AP) is consumed during cardiopulmonary bypass (CPB). A high AP depletion leads to an impaired outcome after cardiac surgery. However, data is scarce on the postoperative course of AP under venoarterial ECMO (VA-ECMO) support. (2) A total of 239 patients with VA-ECMO support between 2000 and 2019 at the Department of Cardiac Surgery (Vienna General Hospital, Austria) were included in this retrospective analysis. Blood samples were collected at several timepoints (baseline, postoperative day (POD) 1-7, POD 14 and 30). Patients were categorized according to the relative AP drop (<60% vs. ≥60%) and ECMO duration (<5 days vs. ≥5 days). (3) Overall, 44.4% reached the baseline AP values within 5 days-this was only the case for 28.6% with a higher AP drop (compared to 62.7% with a lower drop; p = 0.000). A greater AP drop was associated with a significantly higher need for renal replacement therapy (40.9% vs. 61.9%; p = 0.002) and an impaired 1-year survival (51.4% vs. 66.0%; p = 0.031). (4) CPB exceeds the negative impact of VA-ECMO; still, ECMO seems to delay alkaline phosphatase recovery. A greater initial AP drop bears the risk of higher morbidity and mortality.


Subject(s)
Alkaline Phosphatase/blood , Cardiopulmonary Bypass/adverse effects , Extracorporeal Membrane Oxygenation/methods , Aged , Female , Humans , Male , Middle Aged , Retrospective Studies , Survival Analysis , Treatment Outcome
18.
Article in English | MEDLINE | ID: mdl-33691041

ABSTRACT

The HeartMate 3 is a ventricular assist device that supports the heart with a centrifugal continuous flow. It contains a fully levitated rotor to minimize hemolysis and was initially designed as an apical intrapericardial implant. It can be used as a bridge to a transplant, to recovery, or to destination therapy. After we excise the ventricles, we implant 2 HeartMate 3 devices as a total artificial heart (HeartMate 6). The patient was 35 years old when the devices were implanted and had been diagnosed with Yamaguchi syndrome (apical hypertrophic cardiomyopathy) at 13 years of age. Being listed for a transplant was not an option due to secondary pulmonary hypertension. Furthermore, the conventional method of apically implanting a left ventricular assist device was not possible due to the underlying pathology. A HeartMate 6 implant as a bridge to transplant therapy was planned. Additionally, a CardioMEMS HF System was implanted to monitor the pulmonary artery pressure. The video tutorial provides step-by-step instructions for implanting 2 HeartMate 3 devices as a total artificial heart.


Subject(s)
Heart Failure/surgery , Heart Transplantation/methods , Heart Ventricles/surgery , Heart-Assist Devices , Prostheses and Implants , Adult , Humans , Male
19.
Medicina (Kaunas) ; 58(1)2021 Dec 28.
Article in English | MEDLINE | ID: mdl-35056351

ABSTRACT

Background and objectives: Extracorporeal life support (ECLS) is a widely accepted and effective strategy for use in patients presenting with refractory cardiogenic shock. Implantation in awake and non-intubated patients allows for optimized evaluation of further therapy options while avoiding potential side effects associated with the need for sedation and intubation. The aim of the study was the assessment of safety and feasibility of awake ECLS implementation and of outcomes in patients treated with this concept. Materials and Methods: We retrospectively reviewed the concept of awake ECLS implantation in 16 consecutive patients (mean age 58 ± 8 years; male: 88%; ischemic cardiomyopathy: 50%) from 02/2017 to 01/2021. Study endpoints were survival to weaning or bridging to durable support or organ replacement and development of end-organ function and hemodynamic parameters on ECLS. Results: Fourteen patients (88%) were able to be successfully transitioned to definite therapy options. ECLS support stabilized end-organ function, led to a decrease in mean lactate levels (5.3 ± 3.7 mmol/L at baseline to 1.9 ± 1.3 mmol/L 12 h after ECLS start; p = 0.01) and improved hemodynamics (median central venous pressure 20 ± 5 mmHg vs. 10 ± 2 mmHg, p = 0.001) over a median duration of two days (1-8 days IQR). Two patients (13%) died on ECLS support due to multi-organ dysfunction syndrome. Survival to discharge of initially successfully bridged or weaned patients was 64%. Conclusions: Awake ECLS implantation is feasible and safe with the key advantage of omitting or delaying general anesthesia and intubation, with their associated risks in cardiogenic-shock patients, facilitating further decision making.


Subject(s)
Extracorporeal Membrane Oxygenation , Shock, Cardiogenic , Aged , Humans , Male , Middle Aged , Retrospective Studies , Shock, Cardiogenic/therapy , Treatment Outcome , Wakefulness
20.
Front Cardiovasc Med ; 8: 784208, 2021.
Article in English | MEDLINE | ID: mdl-34977190

ABSTRACT

Background: Risk factors for driveline infection (DLI) in patients with left ventricular assist devices are multifactorial. The aim of this study was to analyze the correlation between mechanical driveline features and DLI occurrence. Methods: A meta-analysis was conducted that included studies reporting DLI rates at 6 months after implantation of any of three contemporary devices (HVAD with Pellethane or Carbothane driveline, HeartMate II, and HeartMate 3). Further, outer driveline diameter measurements and ex-vivo experimental three-point bending and torsion tests were performed to compare the stiffness of the four different driveline types. Results: 21 studies with 5,393 patients were included in the meta-analysis. The mean weighted DLI rates ranged from 7.2% (HeartMate II) to 11.9% (HeartMate 3). The HeartMate II driveline had a significantly lower maximal bending force (Loadmax) (4.52 ± 0.19 N) compared to the Carbothane HVAD (8.50 ± 0.08 N), the HeartMate 3 (11.08 ± 0.3 N), and the Pellethane HVAD driveline (15.55 ± 0.14 N) (p < 0.001). The maximal torque (Torquemax) of the HeartMate II [41.44 (12.61) mNm] and the Carbothane HVAD driveline [46.06 (3.78) mNm] were significantly lower than Torquemax of the Pellethane HVAD [46.06 (3.78) mNm] and the HeartMate 3 [95.63 (26.60) mNm] driveline (p < 0.001). The driveline of the HeartMate 3 had the largest outer diameter [6.60 (0.58) mm]. A relationship between the mean weighted DLI rate and mechanical driveline features (Torquemax) was found, as the the HeartMate II driveline had the lowest Torquemax and lowest DLI rate, whereas the HeartMate 3 driveline had the highest Torquemax and highest DLI rate. Conclusions: Device-specific mechanical driveline features are an additional modifiable risk factor for DLI and may influence clinical outcomes of LVAD patients.

SELECTION OF CITATIONS
SEARCH DETAIL
...