Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
2.
Cardiovasc Intervent Radiol ; 38(1): 25-32, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25472936

ABSTRACT

PURPOSE: The hypothesis that covered stents are superior to bare-metal stents (BMS) in long femoropopliteal artery disease was tested. The one-year results of the VIASTAR trial revealed a patency benefit of covered stents in the treatment-per-protocol (TPP) analysis only. METHODS: A prospective, randomized, single-blind, multicenter study evaluated 141 patients with symptomatic peripheral arterial disease (PAD) after treatment with heparin-bonded covered stents (VIABAHN(®) Endoprosthesis) or BMS. Clinical outcomes and patency rates were assessed at 1, 6, 12, and 24 months. Mean lesion length was 19.0 ± 6.3 cm in the VIABAHN(®) versus 17.3 ± 6.6 cm in the BMS group. RESULTS: The 24-month primary patency rates in the VIABAHN(®) and BMS group were: intention-to-treat 63.1 (95 % CI 0.52-0.76) versus 41.2 % (95 % CI 0.29-0.57; log rank p = 0.04) and TPP 69.4 (95 % CI 0.58-0.83) versus 40.0 % (95 % CI 0.28-0.56; log rank p = 0.004). Freedom from target-lesion-revascularization (TLR) was 79.4 (95 % CI 0.70-0.90) versus 73.0 % (95 % CI 0.63-0.85) for VIABAHN(®) versus BMS (log rank p = 0.37). For the TPP group in lesions ≥20 cm, the 24-month patency rates were 65.2 (95 % CI 0.50-0.85) versus 26.7 % (95 % CI 0.12-0.59; log rank p = 0.004) for VIABAHN(®) versus BMS, and freedom from TLR was 80.0 (95 % CI 0.68-0.94) versus 61.9 % (95 % CI 0.44-0.87; log rank p = 0.13). The ankle brachial index was 0.89 ± 0.18 versus 0.91 ± 0.17 (p = 0.76) at 24-month in the VIABAHN(®) versus the BMS group, respectively. CONCLUSION: At 24-month, this trial in PAD patients with long femoropopliteal lesions demonstrated a significantly improved primary patency rate for heparin-bonded covered stents compared to BMS, however, without a significant impact on clinical outcomes and TLR rate (Reg. Nr. ISRCTN48164244).


Subject(s)
Coated Materials, Biocompatible/therapeutic use , Drug-Eluting Stents , Peripheral Arterial Disease/therapy , Aged , Ankle Brachial Index , Anticoagulants/administration & dosage , Equipment Design , Female , Femoral Artery/diagnostic imaging , Follow-Up Studies , Heparin/administration & dosage , Humans , Male , Popliteal Artery/diagnostic imaging , Prospective Studies , Single-Blind Method , Tomography, X-Ray Computed , Treatment Outcome , Ultrasonography, Doppler, Color
3.
J Am Coll Cardiol ; 62(15): 1320-7, 2013 Oct 08.
Article in English | MEDLINE | ID: mdl-23831445

ABSTRACT

OBJECTIVES: The hypothesis that endovascular treatment with covered stents has equal risks but higher efficacy than bare-metal stents (BMS) in long femoropopliteal artery disease was tested. BACKGROUND: Although endovascular treatment of short superficial femoral artery lesions revealed excellent results, efficacy in long lesions remains unsatisfactory. METHODS: In a prospective, randomized, single-blind, multicenter study, 141 patients with symptomatic peripheral arterial disease were assigned to treatment with heparin-bonded, covered stents (Viabahn 72 patients) or BMS (69 patients). Clinical outcomes and patency rates were assessed at 1, 6, and 12 months. RESULTS: Mean ± SD lesion length was 19.0 ± 6.3 cm in the Viabahn group and 17.3 ± 6.6 cm in the BMS group. Major complications within 30 days were observed in 1.4%. The 12-month primary patency rates in the Viabahn and BMS groups were: intention-to-treat (ITT) 70.9% (95% confidence interval [CI]: 0.58 to 0.80) and 55.1% (95% CI: 0.41 to 0.67) (log-rank test p = 0.11); treatment per-protocol (TPP) 78.1% (95% CI: 0.65 to 0.86) and 53.5% (95% CI: 0.39 to 0.65) (hazard ratio: 2.23 [95% CI: 1.14 to 4.34) (log-rank test p = 0.009). In lesions ≥20 cm, (TransAtlantic Inter-Society Consensus class D), the 12-month patency rate was significantly longer in VIA patients in the ITT analysis (VIA 71.3% vs. BMS 36.8%; p = 0.01) and the TPP analysis (VIA 73.3% vs. BMS 33.3%; p = 0.004). Freedom from target lesion revascularization was 84.6% for Viabahn (95% CI: 0.72 to 0.91) versus 77.0% for BMS (95% CI: 0.63 to 0.85; p = 0.37). The ankle-brachial index in the Viabahn group significantly increased to 0.94 ± 0.23 compared with the BMS group (0.85 ± 0.23; p < 0.05) at 12 months. CONCLUSIONS: This randomized trial in symptomatic patients with peripheral arterial disease who underwent endovascular treatment for long femoropopliteal lesions demonstrated significant clinical and patency benefits for heparin-bonded covered stents compared with BMS in lesions ≥20 cm and for all lesions in the TPP analysis. In the ITT analysis for all lesions, which was flawed by major protocol deviations in 8.5% of the patients, the difference was not significant. (GORE VIABAHN® endoprosthesis with bioactive propaten surface versus bare nitinol stent in the treatment of TASC B, C and D lesions in superficial femoral artery occlusive disease; ISRCTN48164244).


Subject(s)
Anticoagulants/administration & dosage , Drug-Eluting Stents , Heparin/administration & dosage , Peripheral Arterial Disease/therapy , Aged , Alloys , Ankle Brachial Index , Coated Materials, Biocompatible , Female , Femoral Artery/surgery , Humans , Male , Polytetrafluoroethylene , Popliteal Artery/surgery , Proportional Hazards Models , Prospective Studies , Single-Blind Method , Stents , Vascular Patency
4.
Acta Radiol ; 54(2): 137-43, 2013 Mar 01.
Article in English | MEDLINE | ID: mdl-23319718

ABSTRACT

BACKGROUND: Breast cancer screening programs have been established worldwide and early detection of breast cancer has increased steadily. The most common way to confirm dignity of non-palpable and sonographically-occult suspicious findings on mammography is the stereotactically-guided vacuum-assisted breast biopsy PURPOSE: To compare two stereotactically guided vacuum-assisted breast biopsy systems measuring time effectiveness and quality of harvested material in clinical practice. MATERIAL AND METHODS: One hundred and forty-six patients presenting with suspicious microcalcifications on mammography were included in the study. Biopsies were carried out with either the Mammotome(®) system (11-gauge and 8-gauge) or the ATEC(®) system (12-gauge and 9-gauge). Lesions with a diameter <15 mm on mammography were biopsied with 11-gauge or 12-gauge devices whereas lesions >15 mm were targeted with 8-gauge and 9-gauge. Mammotome(®) system 8-gauge device was used in 34 patients, the 11-gauge system in 37 patients. The ATEC(®) system 9-gauge system was used in 37 patients and 12-gauge in 38 patients. Time was taken, focusing on preparing the system, time of collecting the samples, preparing the samples, and cleaning the site. During the biopsies 24 samples were taken. The histologic quality of the tissue samples was judged by a pathologist in a blinded fashion according to a specimen grading classification concerning tissue fragmentation, artefacts, and the adequacy of the tissue for diagnosis. RESULTS: The median overall time for the Mammotome(®) system was 879 s (11-gauge) and 934 s (8-gauge) and for the ATEC(®) system 671 s (12-gauge) and 673 s (9-gauge). The ATEC(®) system displays a significantly shorter overall time for small and large biopsy devices (U-test, P < 0.001). Concerning the mean time difference of the overall time comparing small and large systems the ATEC(®) system was 267.6 s faster using the small and 244.8 s faster using the large system. Comparing the histologic quality of tissue samples the Mammotome(®) system shows significantly higher values for the large and the small system (Chi-square test, P < 0.001). CONCLUSION: Both biopsy systems meet all requirements for daily practice and confirm the diagnosis of suspicious microcalcifications. The ATEC(®) system was observed to be faster but this difference of about 250 s might not be relevant in daily practice. The Mammotome(®) system provides a better histologic quality of tissue samples.


Subject(s)
Biopsy/instrumentation , Breast/pathology , Stereotaxic Techniques/instrumentation , Biopsy/methods , Calcinosis/pathology , Female , Humans , Middle Aged , Vacuum
5.
Cardiovasc Intervent Radiol ; 33(4): 828-34, 2010 Aug.
Article in English | MEDLINE | ID: mdl-19967366

ABSTRACT

The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helically bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 +/- 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 +/- 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 +/- 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 +/- 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 +/- 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.


Subject(s)
Biopsy/instrumentation , Lung/diagnostic imaging , Lung/pathology , Tomography, X-Ray Computed/methods , Animals , Catheters , Diaphragm , Fluoroscopy/methods , Models, Animal , Models, Biological , Phantoms, Imaging , Respiratory Mechanics , Swine
6.
Cardiovasc Intervent Radiol ; 33(3): 583-5, 2010 Jun.
Article in English | MEDLINE | ID: mdl-19937025

ABSTRACT

We present a safe and quick technique for crossover embolization procedures of the internal iliac artery with high-profile guiding catheter systems, after a pull-through maneuver with establishment of a crossover catheter-snare system. The attached snare is used to stabilize and direct the guiding catheter.


Subject(s)
Aortic Aneurysm/therapy , Catheterization, Peripheral/methods , Embolization, Therapeutic/methods , Iliac Aneurysm/therapy , Angiography , Catheterization, Peripheral/instrumentation , Embolization, Therapeutic/instrumentation , Humans , Radiography, Interventional
7.
J Vasc Interv Radiol ; 19(2 Pt 1): 182-8, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18341946

ABSTRACT

PURPOSE: To analyze the immediate and midterm success of low-profile stent placement in calcified ulcerated lesions of the infrarenal aorta in patients with arterial occlusive disease. MATERIALS AND METHODS: In this prospective case series, 13 symptomatic patients (eight men, five women; mean age, 64.8 years +/- 12.1; age range, 44-84 years) with focal calcified ulcerated stenoses of the infrarenal aorta were treated with stent placement by using a low-profile technique in a radiology intervention center during a 4-year period. Clinical examinations and duplex ultrasonography were used to evaluate the stents? patency and clinical success. Kaplan-Meier graphs were calculated to analyze the freedom-of-symptom rate. RESULTS: The initial technical success rate was 92% (12 of 13 patients). Due to extended calcifications, a residual stenosis of 50%-60% remained in one patient. No peri-interventional complications occurred. The mean follow-up was 26 months (range, 5-53 months). During follow-up, one patient had a restenosis after 7 months and presented clinically with Fontaine stage IIb. Two patients had iliac and/or femoral stenoses, and both presented with Fontaine stage IIb. One patient's symptoms originated from the lumbar spine. Primary patency and primary clinical success rates were 85% and 69%, respectively. According to Kaplan-Meier tables, the freedom-from-symptom rates were 92%, 84%, 73%, and 63% at 0, 7, 12, and 21 months, respectively. CONCLUSIONS: Low-profile stent placement in calcified, ulcerated lesions of the infrarenal aorta is an effective and safe treatment for symptomatic stenoses in patients with arterial occlusive disease after a mean follow-up of 26 months.


Subject(s)
Aorta, Abdominal , Aortic Diseases/therapy , Arterial Occlusive Diseases/therapy , Calcinosis/therapy , Stents , Adult , Aged , Female , Humans , Male , Middle Aged , Prospective Studies , Radiography, Interventional , Recurrence , Treatment Outcome , Vascular Patency
8.
J Vasc Interv Radiol ; 18(10): 1241-8, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17911514

ABSTRACT

PURPOSE: To characterize a new protocol of computed tomographic (CT) fluoroscopy-guided biopsy of the lung and upper abdomen to minimize the intervention time, complication rate, and exposure to ionizing radiation for both the patient and the radiologist. MATERIALS AND METHODS: Fifty patients (23 women, 27 men; mean age, 64.3 years; age range, 36-83 years) with lung (n = 41) or upper abdomen (n = 9) nodules 15 mm or smaller underwent CT fluoroscopy-guided biopsy from November 2005 to October 2006. The mean nodule diameter was 12.6 mm (range, 8-15 mm), the mean depth to skin was 57.3 mm (range, 20-114 mm), and the mean depth of nodules from pleura and/or peritoneum was 18.9 mm (range, 1-77 mm). Histopathologic evaluation of samples was performed on the day of the procedure. A CT fluoroscopy-guided biopsy protocol was established as follows: (a) native CT with breath-holding at an intermediate respiration level, (b) selection of section position with target nodule and insertion of an 18-gauge coaxial biopsy needle extrapleurally and/or extraperitoneally virtually targeting at nodule, (c) start of CT fluoroscopy (130 kVp, 30 mAs, 5-mm-thick sections) at inspiration level with the patient expiring, (d) stop of CT fluoroscopy when the target nodule reaches the section position, short breath-hold, needle advancement to the target nodule, (e) control of needle position with CT fluoroscopy, and (f) biopsy. RESULTS: The mean total table time was 23.8 minutes (range, 15-41 minutes), the mean duration of CT fluoroscopy was 8.2 seconds (range, 4-23 seconds), and the mean duration of breath-holding--including needle insertion to target nodule and control CT fluoroscopy--was 10.3 seconds (range, 5-15 seconds). There were three minor pneumothoraces that required no further intervention, seven minor pulmonary hemorrhages, three moderate pulmonary hemorrhages with hemoptysis, and one moderate liver hematoma. There were no major complications. The diagnostic accuracy of biopsy samples was 96%. CONCLUSIONS: The presented modification of CT fluoroscopy-guided biopsy of mobile pulmonary and upper abdominal lesions is a rapid and safe procedure, requiring only short exposure to ionizing radiation.


Subject(s)
Abdominal Neoplasms/diagnostic imaging , Biopsy, Needle/methods , Lung Neoplasms/diagnostic imaging , Radiography, Interventional , Respiration , Tomography, X-Ray Computed , Abdominal Neoplasms/pathology , Abdominal Neoplasms/physiopathology , Adult , Aged , Aged, 80 and over , Biopsy, Needle/adverse effects , Female , Fluoroscopy , Hematoma/etiology , Hemoptysis/etiology , Hemorrhage/etiology , Humans , Liver Diseases/etiology , Lung Diseases/etiology , Lung Neoplasms/pathology , Lung Neoplasms/physiopathology , Male , Middle Aged , Pneumothorax/etiology , Predictive Value of Tests , Prospective Studies , Severity of Illness Index , Time Factors
9.
Cardiovasc Intervent Radiol ; 30(3): 376-82, 2007.
Article in English | MEDLINE | ID: mdl-17278036

ABSTRACT

The objective of the study was to prove the value of single-dose contrast-enhanced magnetic resonance angiography [three-dimensional (3D) ceMRA] in abdominal and iliac arteries versus the reference standard intra-arterial digital subtraction angiography (i.a.DSA) when indicating a therapy. Patients suspected of having abdominal or iliac artery stenosis were included in this study. A positive vote of the local Ethics Committe was given. After written informed consent was obtained, 37 patients were enrolled, of which 34 were available for image evaluation. Both 3D ceMRA and i.a. DSA were performed for each patient. The dosage for 3D ceMRA was 0.1 mmol/kg body weight in a 1.5-T scanner with a phased-array coil. The parameters of the 3D-FLASH sequence were as follows: TR/TE 4.6/1.8 ms, effective thickness 3.5 mm, matrix 512 x 200, flip angle 30 degrees , field of view 420 mm, TA 23 s, coronal scan orientation. Totally, 476 vessel segments were evaluated for stenosis degree by two radiologists in a consensus fashion in a blinded read. For each patient, a therapy was proposed, if clinically indicated. Sensitivity, specificity, positive and negative predictive values, and accuracy for stenoses > or = 50% were 68%, 92%, 44%, 97%, and 90%, respectively. In 13/34 patients, a discrepancy was found concerning therapy decisions based on MRA findings versus therapy decisions based on the reference standard DSA. The results showed that the used MRA imaging technique of abdominal and iliac arteries is not competitive to i.a. DSA, with a high rate of misinterpretation of the MRAs resulting in incorrect therapies.


Subject(s)
Angiography, Digital Subtraction/methods , Aortic Diseases/diagnosis , Aortography/methods , Arterial Occlusive Diseases/diagnosis , Contrast Media , Gadolinium DTPA , Iliac Artery , Image Processing, Computer-Assisted/methods , Magnetic Resonance Angiography/methods , Aged , Angioplasty, Balloon , Aortic Diseases/therapy , Blood Vessel Prosthesis Implantation , Female , Humans , Iliac Artery/pathology , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Sensitivity and Specificity , Stents , Triiodobenzoic Acids
10.
Abdom Imaging ; 32(3): 304-9, 2007.
Article in English | MEDLINE | ID: mdl-16955377

ABSTRACT

This article focuses on stent placement in mesenteric arteries in patients with the rare diagnosis of chronic mesenteric ischemia. We present a survey from the initial stage of recognition of this gastrointestinal disorder and its manifestations to treatment by stenting to avoid further ischemic episodes and bowel infarction and necrosis. The advantages of stent placement in splanchnic arteries are discussed in comparison to open surgical revascularization.


Subject(s)
Mesenteric Arteries , Mesenteric Vascular Occlusion/therapy , Stents , Chronic Disease , Humans , Mesenteric Vascular Occlusion/diagnostic imaging , Radiography, Interventional
11.
Eur J Radiol ; 61(2): 315-23, 2007 Feb.
Article in English | MEDLINE | ID: mdl-17074459

ABSTRACT

PURPOSE: Prospective evaluation of diagnostic accuracy of single field-of-view contrast-enhanced MR Angiography (ceMRA) with 1.0M gadobutrol compared to intraarterial DSA in body arteries. MATERIALS AND METHODS: In an European multicenter study 179 patients underwent ceMRA and DSA. For each indication five prospectively defined vessel segments were evaluated by local investigators onsite and by three site-independent blinded readers (BR) independently. RESULTS: The agreement between ceMRA and DSA diagnosis was statistically significant in the onsite (96.6%) and blinded reader (86.6-90.2%) evaluation. Sensitivity, specificity, accuracy, positive (PPV) and negative predictive values (NPV) for detection of relevant stenosis (>50%) were calculated for the right and left internal carotid arteries, and common and external iliac arteries: Sensitivity was 95-98% (onsite) and 76-96% (BR), specificity 94-96% (onsite) and 86-94% (BR), accuracy 96% (onsite) and 87-93% (BR), NPV 98-99% (onsite) and 84-98% (BR), and PPV 79-93% (onsite) and 44-91% (BR), respectively. CONCLUSION: CeMRA of body arteries using 1.0M gadobutrol provides diagnostic information comparable to intraarterial DSA.


Subject(s)
Angiography, Digital Subtraction , Arteries/pathology , Magnetic Resonance Angiography/methods , Adult , Aged , Aged, 80 and over , Constriction, Pathologic/diagnosis , Contrast Media , Gadolinium , Humans , Male , Middle Aged , Organometallic Compounds , Prospective Studies , Sensitivity and Specificity , Single-Blind Method
12.
J Vasc Interv Radiol ; 17(4): 637-43, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16614146

ABSTRACT

PURPOSE: To analyze the immediate and midterm success of stenting of mesenteric arteries by a monorail technique in patients with chronic mesenteric ischemia. MATERIALS AND METHODS: In this prospective case series, 19 patients (11 male, 8 female; mean age, 62.9 +/- 10.4 y; range, 36-82 y) with 23 symptomatic stenoses of mesenteric arteries were treated with stent placement by a monorail technique in a radiologic intervention center over a period of 4.5 years. Clinical examinations and duplex sonography were used to evaluate the stents' patency and clinical success. Kaplan-Meier graphs were calculated to analyze the patency and freedom-from-symptom rate. RESULTS: Initial technical success rate was 22/23 (96%). Mean follow-up was 17 months (range, 1-58 mo). Primary patency and primary clinical success rates were 82% and 78%, respectively. According to Kaplan-Meier tables, the patency rates were 96%, 87%, 76%, and 61% at 0, 1, 15, and 24 months, respectively, and the freedom-from-symptom rates were 95%, 90%, 72%, and 54% at 0, 1, 24, and 30 months, respectively. No peri-interventional complications occurred. Two patients died of cardiac failure in the hospital within 30 days after intervention; deaths were not related to the intervention. CONCLUSIONS: Stent placement by a monorail technique in mesenteric arteries is an effective and safe treatment for symptomatic stenoses in patients with chronic mesenteric ischemia after a mean follow-up of 17 months.


Subject(s)
Mesenteric Vascular Occlusion/therapy , Stents , Adult , Aged , Aged, 80 and over , Angiography, Digital Subtraction , Female , Humans , Male , Mesenteric Arteries , Mesenteric Vascular Occlusion/diagnostic imaging , Middle Aged , Prospective Studies , Radiography, Interventional , Treatment Outcome , Ultrasonography, Doppler, Duplex , Ultrasonography, Interventional , Vascular Patency
13.
Eur J Radiol ; 58(3): 411-5, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16466674

ABSTRACT

OBJECTIVE: To evaluate fat-suppressed (FS) proton-density-weighted (PDw) turbo spin-echo (TSE) magnetic resonance imaging for the detection of anterior and posterior cruciate ligament lesions in comparison to arthroscopy. MATERIALS AND METHODS: In a prospective study 31 knee joints were imaged on a 1.5T MR scanner (Vision, Siemens, Erlangen) prior to arthroscopy using following sequences: (a) sagittal FS-PDw/T2w TSE (TR/TE: 4009/15/105 ms); (b) sagittal PDw/T2w TSE (TR/TE:3800/15/105 ms). Further imaging parameters: slice thickness 3mm, FOV 160 mm, matrix 256 x 256. A total of 62 anterior and posterior cruciate ligaments (ACL/PCL) were evaluated, standard of reference was arthroscopy. Sensitivity, specificity, positive (ppv) and negative predictive value (npv) and accuracy were calculated. RESULTS: Twenty-one cruciate ligament ruptures were detected in arthroscopy, 19 ACL- and 2 PCL-ruptures (on MRI 34/124, 25/62 ACL, 9/62 PCL lesions). For all four sequences in the 31 patients with arthroscopic correlation sensitivity, specificity, ppv, npv and accuracy were 86%, 98%, 95%, 93% and 94% for detection of tears, and 84%, 100%, 100%, 80% and 90% for ACL-ruptures respectively. The two PCL-ruptures were true positive in all sequences, one intact PCL was diagnosed as torn (false positive). CONCLUSIONS: Fat-suppressed PDw/T2w TSE-MR sequences are comparable to PDw TSE sequences for the detection of ACL/PCL-lesions.


Subject(s)
Anterior Cruciate Ligament/pathology , Arthroscopy/methods , Image Enhancement/methods , Joint Diseases/diagnosis , Magnetic Resonance Imaging/methods , Posterior Cruciate Ligament/pathology , Adolescent , Adult , Aged , Female , Humans , Knee Joint/pathology , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Prospective Studies , Reproducibility of Results , Rupture/diagnosis , Sensitivity and Specificity
14.
Eur Radiol ; 16(7): 1488-93, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16435136

ABSTRACT

The objective of the study was to evaluate MRI for visualization of acromioclavicular (ac) joint structures in cadaveric shoulders, asymptomatic volunteers and symptomatic patients with trauma of the ac-joint. Three cadaveric shoulders were examined to find adequate planes and sequences for MRI. Afterwards, MR images were correlated to corresponding anatomical sections. Six asymptomatic volunteers and 13 patients were scanned in a 1.5 T Magnetom Vision with three sequences in the following planes: (1) parallel to the clavicle; (2) orthogonal to the ac joint, each time a fat-suppressed proton density-weighted + T2-sequence (TR/TE 4,000/15 ms) was performed; (3) parallel to the clavicle, T1-SE (TR/TE 817/20 ms). The parameters were: slice thickness 3 mm, field-of-view 180 mm, matrix 210x256 pixels. Standard of reference in the patients was clinical examination and conventional X-rays. Classification was by Rockwood grades I-VI. MRI allowed excellent visualization and diagnoses of ac-joint structures in volunteers and patients (n=6 normal, n=1 Rockwood I, n=5 Rockwood II, n=3 Rockwood III, n=4 Rockwood V). On MRI, in one lesion type II and III each, a lower lesion type was suspected clinically and by X-ray. In one patient additional information by MRI led to surgery. MRI allows excellent anatomical display of ac-joint structures and can give clinically relevant information on type and extension of ac-joint trauma, which may influence therapy.


Subject(s)
Acromioclavicular Joint/injuries , Acromioclavicular Joint/pathology , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Adult , Cadaver , Humans , In Vitro Techniques , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
15.
Radiology ; 238(3): 827-40, 2006 Mar.
Article in English | MEDLINE | ID: mdl-16424245

ABSTRACT

PURPOSE: To prospectively evaluate accuracy of gadolinium-enhanced three-dimensional (3D) magnetic resonance (MR) angiography with gadodiamide and gadopentetate dimeglumine (0.1 mmol/kg), with intraarterial DSA as reference standard, for imaging abdominal and iliac arterial stenoses. MATERIALS AND METHODS: The study was approved by all institutional review boards; informed consent was obtained from each subject before procedures. Two hundred forty-seven subjects were included; 240 received either contrast agent and were available for safety analysis; 222 were available for accuracy analysis. Enhanced 3D MR angiography and DSA were performed; image data were evaluated in a double-blinded randomized study. Stenoses were classified as not relevant (<50% stenosis) or relevant (> or =50%). For detection of main stenosis, accuracy with enhanced 3D MR angiography compared with that with DSA was determined. RESULTS: The difference in accuracy for imaging with gadodiamide and gadopentetate was 3.6%. Noninferiority was inferred because the lower bound of the exact two-sided 95% confidence interval was -10.1 and was above the noninferiority margin (-15%). Accuracy for detection of the main stenosis was low, 56.4% for gadodiamide and 52.8% for gadopentetate group. Subgroup analysis with exclusion of inferior mesenteric artery and internal iliac arteries and the most false-positive stenosis classifications yielded better results: 76.6% and 71.6%, respectively. Sensitivity, specificity, and negative and positive predictive values did not differ substantially between study groups. In the main analysis, values were 44%, 96%, 35%, and 97% for gadodiamide and 44%, 83%, 30%, and 90% for gadopentetate, respectively. In the subgroup analysis, values were 66%, 95%, 61%, and 96% for gadodiamide and 63%, 86%, 58%, and 88% for gadopentetate, respectively. CONCLUSION: Noninferiority of gadodiamide versus gadopentetate was verified based on the primary end point, which was accuracy for detection of the main stenosis with enhanced 3D MR angiography compared with DSA.


Subject(s)
Abdomen/blood supply , Arterial Occlusive Diseases/diagnosis , Contrast Media , Gadolinium DTPA , Iliac Artery , Imaging, Three-Dimensional , Magnetic Resonance Angiography/methods , Adult , Aged , Aged, 80 and over , Angiography, Digital Subtraction , Arterial Occlusive Diseases/diagnostic imaging , Double-Blind Method , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...