Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 23(20)2023 Oct 20.
Article in English | MEDLINE | ID: mdl-37896700

ABSTRACT

High-aspect-ratio carbon nanotubes can be directly mixed into polymers to create piezoresistive polymers. Reducing the cross-sensitivity and creating unidirectional sensitive sensors can be achieved by aligning the nanotubes before they are cured in the polymer layer. This research presents and characterises this alignment of carbon nanotubes inside polydimethylsiloxane and gives the corresponding strain sensor results. The influence on the alignment method, as well as the field strength, frequency and time is shown. An analytical model is created to investigate the sensor's behaviour and determine the effect of electron-tunnelling in the sensor. A numerical model gives insight into the necessary applied field strength, frequency and time to facilitate alignment in viscous liquids. The experimental data show a two-phase piezoresistive response; first, a linear strain response, after which the more dominant electron-tunnelling piezoresistive phase starts with high gauge factors up to k ≈ 4500 in the preferential direction, depending on the carbon nanotube concentration. Gauge factors in the orthogonal direction remain low (k ≈ 22). Finally, the dynamic stability of the sensors is proven by exposing the sensors to a cyclic strain. Small initial drifts are observed but appear to stabilise after several cycles.

2.
Polymers (Basel) ; 14(18)2022 Sep 06.
Article in English | MEDLINE | ID: mdl-36145847

ABSTRACT

The lack of long-term stability of polymeric neural interfaces remains one of the most important and less tackled issues in this research field. To address this issue, we fabricated two test structures based on interdigitated electrodes (IDEs) encapsulated with polyimide (PI). One of the test samples was pretreated with barrel oxygen plasma prior to spin coating of the second PI layer. The second test structure was pretreated using a reactive ion etching (RIE) process. The test samples were immersed in an electrolyte solution at elevated temperatures to mimic the conditions inside the human brain. The samples were then electrically and mechanically stressed to accelerate their degradation. Real-time monitoring of the electrical insulation stability was used to compare the impact of the pretreatment on the long-term stability. Barrel-plasma-activated test samples showed a mean lifetime of 1.5 days, whereas RIE pretreatment increased the mean lifetime to 24 days. Therefore, RIE-pretreated test samples exhibited 16 times longer mean stability compared to purely chemically activated test samples. Furthermore, the electrical measurements were correlated with mechanical adhesion tests. Chemically activated test samples showed significant delamination, whereas RIE pretreatment enhanced the adhesion, and no delamination could be observed. The correlation of these investigations suggests that the adhesion between different layers is higher following RIE pretreatment compared to pretreatment with chemical barrel plasma. In conclusion, the adhesion between the two PI foils seems to play a key role in the long-term stability of such devices.

3.
Micromachines (Basel) ; 12(11)2021 Oct 20.
Article in English | MEDLINE | ID: mdl-34832690

ABSTRACT

For chronic applications of flexible neural implants, e.g., intracortical probes, the flexible substrate material has to encapsulate the electrical conductors with a long-term stability against the saline environment of the neural tissue. The biocompatible polymer polyimide is often used for this purpose. Due to its chemical inertness, the adhesion between two polyimide layers is, however, a challenge, which can lead to delamination and, finally, to short circuits. The state-of-the-art method to improve the adhesion strength is activating the polyimide surface using oxygen reactive ion etching (O2 RIE). However, the influence of the process variations (etching time, bias power) on the long-term stability is still unclear. Therefore, we establish a test method, where the aging of a gold interdigital structure embedded in two polyimide layers and immersed in saline solution is accelerated using an elevated temperature, mechanical stress and an electrical field. A continuous measurement of a leakage current is used to define the failure state. The results show that the variation of the O2 RIE plasma process has a significant effect on the long-term stability of the test samples. Comparing the two different plasma treatments 0.5 min at 25 W and 1 min at 50 W, the long-term stability could be increased from 20.9 ± 19.1 days to 44.9 ± 18.9 days. This corresponds to more than a doubled lifetime. An ideal solution for the delamination problem is still not available; however, the study shows that the fine-tuning of the fabrication processes can improve the long-term stability of chronically implanted neural electrodes.

4.
Polymers (Basel) ; 13(12)2021 Jun 12.
Article in English | MEDLINE | ID: mdl-34204615

ABSTRACT

Polyimide films are currently of great interest for the development of flexible electronics and sensors. In order to ensure a proper integration with other materials and PI itself, some sort of surface modification is required. In this work, microwave oxygen plasma, reactive ion etching oxygen plasma, combination of KOH and HCl solutions, and polyethylenimine solution were used as surface treatments of PI films. Treatments were compared to find the best method to promote the adhesion between two polyimide films. The first selection of the treatment conditions for each method was based on changes in the contact angle with deionized water. Afterward, further qualitative (scratch test) and a quantitative adhesion assessment (peel test) were performed. Both scratch test and peel strength indicated that oxygen plasma treatment using reactive ion etching equipment is the most promising approach for promoting the adhesion between polyimide films.

5.
J Neurophysiol ; 122(4): 1634-1648, 2019 10 01.
Article in English | MEDLINE | ID: mdl-31412218

ABSTRACT

Recordings of epidural field potentials (EFPs) allow neuronal activity to be acquired over a large region of cortical tissue with minimal invasiveness. Because electrodes are placed on top of the dura and do not enter the neuronal tissue, EFPs offer intriguing options for both clinical and basic science research. On the other hand, EFPs represent the integrated activity of larger neuronal populations and possess a higher trial-by-trial variability and a reduced signal-to-noise ratio due the additional barrier of the dura. It is thus unclear whether and to what extent EFPs have sufficient spatial selectivity to allow for conclusions about the underlying functional cortical architecture, and whether single EFP trials provide enough information on the short timescales relevant for many clinical and basic neuroscience purposes. We used the high spatial resolution of primary visual cortex to address these issues and investigated the extent to which very short EFP traces allow reliable decoding of spatial information. We briefly presented different visual objects at one of nine closely adjacent locations and recorded neuronal activity with a high-density epidural multielectrode array in three macaque monkeys. With the use of receiver operating characteristics (ROC) to identify the most informative data, machine-learning algorithms provided close-to-perfect classification rates for all 27 stimulus conditions. A binary classifier applying a simple max function on ROC-selected data further showed that single trials might be classified with 100% performance even without advanced offline classifiers. Thus, although highly variable, EFPs constitute an extremely valuable source of information and offer new perspectives for minimally invasive recording of large-scale networks.NEW & NOTEWORTHY Epidural field potential (EFP) recordings provide a minimally invasive approach to investigate large-scale neural networks, but little is known about whether they possess the required specificity for basic and clinical neuroscience. By making use of the spatial selectivity of primary visual cortex, we show that single-trial information can be decoded with close-to-perfect performance, even without using advanced classifiers and based on very few data. This labels EFPs as a highly attractive and widely usable signal.


Subject(s)
Evoked Potentials, Visual , Visual Cortex/physiology , Visual Perception/physiology , Animals , Dura Mater/physiology , Electrodes, Implanted , Macaca mulatta , Machine Learning , Male , ROC Curve , Signal Processing, Computer-Assisted , Signal-To-Noise Ratio
6.
Micromachines (Basel) ; 9(3)2018 Mar 16.
Article in English | MEDLINE | ID: mdl-30424065

ABSTRACT

Bidirectional neural interfaces for multi-channel, high-density recording and electrical stimulation of neural activity in the central nervous system are fundamental tools for neuroscience and medical applications. Especially for clinical use, these electrical interfaces must be stable over several years, which is still a major challenge due to the foreign body response of neural tissue. A feasible solution to reduce this inflammatory response is to enable a free-floating implantation of high-density, silicon-based neural probes to avoid mechanical coupling between the skull and the cortex during brain micromotion. This paper presents our latest development of a reproducible microfabrication process, which allows a monolithic integration of a highly-flexible, polyimide-based cable with a silicon-stiffened neural probe at a high resolution of 1 µm. For a precise and complete insertion of the free-floating probes into the cortex, a new silicon-based, vacuum-actuated insertion tool is presented, which can be attached to commercially available electrode drives. To reduce the electrode impedance and enable safe and stable microstimulation an additional coating with the electrical conductive polymer PEDOT:PSS is used. The long-term stability of the presented free-floating neural probes is demonstrated in vitro and in vivo. The promising results suggest the feasibility of these neural probes for chronic applications.

SELECTION OF CITATIONS
SEARCH DETAIL
...