Forensic Sci Int Genet ; 40: 96-104, 2019 05.
Article in English | MEDLINE | ID: mdl-30785062

ABSTRACT

For several decades, a common approach for processing sexual assault evidence has been to use the "standard" differential extraction to separate the evidence into a non-sperm-cell fraction and a sperm-cell fraction for further analysis. In this standard approach (P. Gill et al., Nature 318 (1985) 577-579), an initial mild chemical lysis step preferentially digests the mainly epithelial cells, which allows for removing this lysate as a non-sperm-cell fraction. The undigested sperm cells in the remaining fraction may then be purified by a series of wash and centrifugation steps, after which more robust lysis conditions are used to digest this sperm-cell fraction. Although this standard approach has been generally effective, it has been difficult to fully automate, due to the variety of different types of manipulations required for sample processing (e.g., incubation, shaking, substrate separation by centrifugation, and multiple liquid transfers for sperm-pellet centrifugation and washing steps). We describe here a fully automated standard differential extraction procedure that uses the Hamilton AutoLys STAR liquid handling assay-ready workstation, which is configured with on-deck components for sample incubation, shaking and centrifugation steps, and works with unique AutoLys-A® sample tubes for front-end sample processing. In this proof-of-concept procedure, up to 24 samples may be processed, "hands-free," in a single automated workflow. The automated procedure was tested by performing differential extractions on mock sexual assault swabs. For comparison, manual differential extractions were performed on identically prepared swabs in a side-by-side manner. DNA quantification and STR typing results showed that similar levels of separation efficiency were achieved for the sperm-cell fractions using both automated and manual procedures, although the results suggest that somewhat higher male DNA yields may be achieved for samples with extremely low semen levels (<∼0.1 µL) using the manual processing procedure. In addition to these mock samples, automated differential extractions were also performed on a set of authentic post-coital swabs (24, 48, 72, and 96 hours, post-coitus); primarily male STR profiles for the sperm-cell fractions were obtained for each sample in this set.


Subject(s)
Automation , DNA/isolation & purification , Robotics , Sex Offenses , Specimen Handling/methods , DNA Fingerprinting , Female , Humans , Male , Microsatellite Repeats , Polymerase Chain Reaction , Semen/chemistry
2.
Croat Med J ; 52(3): 280-92, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21674824

ABSTRACT

AIM: To describe and assess the scientific and technical aspects of animal forensic testing at the University of California, Davis. The findings and recommendations contained in this report are designed to assess the past, evaluate the present, and recommend reforms that will assist the animal forensic science community in providing the best possible services that comply with court standards and bear judicial scrutiny. METHODS: A batch of 32 closed files of domestic dog DNA cases processed at the University of California, Davis, between August 2003 and July 2005 were reviewed in this study. The case files comprised copies of all original paperwork, copies of the cover letter or final report, laboratory notes, notes on analyses, submission forms, internal chains of custody, printed images and photocopies of evidence, as well as the administrative and technical reviews of those cases. RESULTS: While the fundamental aspects of animal DNA testing may be reliable and acceptable, the scientific basis for forensic testing animal DNA needs to be improved substantially. In addition to a lack of standardized and validated genetic testing protocols, improvements are needed in a wide range of topics including quality assurance and quality control measures, sample handling, evidence testing, statistical analysis, and reporting. CONCLUSION: This review implies that although a standardized panel of short tandem repeat and mitochondrial DNA markers and publicly accessible genetic databases for canine forensic DNA analysis are already available, the persistent lack of supporting resources, including standardized quality assurance and quality control programs, still plagues the animal forensic community. This report focuses on closed cases from the period 2003-2005, but extends its scope more widely to include other animal DNA forensic testing services.


Subject(s)
DNA, Mitochondrial/analysis , Forensic Genetics/methods , Genetic Markers , Microsatellite Repeats/genetics , Animals , California , Crime , DNA/analysis , Databases, Genetic , Dogs , Feasibility Studies , Quality Control , Reproducibility of Results