Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
2.
Anaesthesiologie ; 73(2): 124-129, 2024 02.
Article in German | MEDLINE | ID: mdl-38214706

ABSTRACT

Patients benefit from the use of check valves when drugs with a particularly short half-life (e.g., catecholamines) are continually administered through a one-way valve or when an accidental retrograde bolus application must be prevented, as in the event of a rapid sequence induction and intubation. The lack of a check valve can prevent the administered drug from working in the intended manner resulting in potentially insufficient treatment and negative consequences for the patient. In order to ensure the highest level of patient safety while using check valves appropriate training of medical personnel is essential. In contrast, preventable dangers (e.g., infections, awareness) exist when safety measures are disregarded, including the re-use of medications, syringes or disposable materials in successive patients after having only exchanged the check valves. It is not clear how often this is practiced in German-speaking areas.


Subject(s)
Patient Safety , Syringes , Humans , Syringes/adverse effects , Health Personnel
3.
Anaesthesist ; 69(3): 192-197, 2020 03.
Article in English | MEDLINE | ID: mdl-32055882

ABSTRACT

BACKGROUND: In recent years, ultrasound (US) has become more incorporated into anesthesia and intensive care medicine. The German Anesthesia Society established a modular curriculum to teach US skills. Until now, the efficacy of this modular curriculum has not been validated. OBJECTIVE: The main objective of this study was to determine whether there is an increase of knowledge and of psychomotor skills for the trainees in this curriculum. MATERIAL AND METHODS: After ethical committee approval, 41 anesthesia physicians were enrolled. To determine the increase of knowledge and of practical skills theoretical and practical tests performed were evaluated before and after two different US courses. RESULTS: Comparing before and after course tests, the participants showed significant improvement in theoretical multiple choice tests (p = 0.008). Regarding psychomotor skills following course 1, the trainees improved significantly in the time needed to perform the two practical tests (p = 0.03), but not in the performance of the test. Better needle visualization during simulated US-guided vessel puncture (p = 0.52) and better identification of the anatomical structures in the axillary region (p = 0.56) could not be achieved. CONCLUSION: This study shows that although this US course curriculum has positively enhanced the trainees' theoretical knowledge of US practice, it does not enhance the practical application of that theoretical knowledge. To improve this curriculum, a supervised clinically practical training should follow the course.


Subject(s)
Anesthesiologists/education , Ultrasonography/trends , Adult , Anesthesiology , Curriculum , Education, Medical/methods , Educational Measurement , Female , Germany , Humans , Internship and Residency , Male , Professional Practice Gaps
4.
Med Klin Intensivmed Notfmed ; 113(3): 202-207, 2018 04.
Article in German | MEDLINE | ID: mdl-28497206

ABSTRACT

BACKGROUND: Lung ultrasound (LUS) is a point-of-care technique which can quickly identify or rule out pathological findings. To date, it is unclear if knowledge about the use of LUS is readily available. OBJECTIVES: We aimed to identify how much knowledge about the use of LUS is present, if there is a need for teaching in LUS, as well as the preferred teaching method in LUS. MATERIALS AND METHODS: A total of 54 participants from two university departments of anesthesiology were randomized into the groups Online, Classroom, and Control. The Online group was taught by videos, the Classroom group by a traditional lecture with hands-on training, and the Control group was not taught at all. We conducted a pre- and posttest as well as a retention test 4 weeks after the end of the study by means of a survey (comparison with Mann-Whitney U test or t­test, respectively, with p < 0.05 considered to be significant). RESULTS: LUS is used "rarely" or "never", and mainly if there is a suspicion for pleural effusion (41.3%). There is a need for LUS (Online: 21.7%; Classroom: 60.9%; Control: 62.5%, p < 0.05). Hybrid teaching consisting of classroom-based and online-based teaching is preferred by the users (Online: 52.2%; Classroom: 56.5%; Control: 62.5%). At the end of the study, 32.6% of the participants of the intervention groups had used LUS in the diagnosis of a pneumothorax. Of the participants, 93.5% planned to use LUS more often in the future. CONCLUSIONS: LUS is rarely used. There is a considerable need for teaching of LUS. Internet-based teaching and traditional lectures are considered equal. Both teaching methods improve the knowledge about LUS and lead to increased use of LUS in daily practice. The participants prefer hybrid teaching incorporating both teaching methods.


Subject(s)
Anesthesiology , Lung , Pneumothorax , Ultrasonography , Anesthesiology/education , Humans , Lung/diagnostic imaging , Point-of-Care Systems , Ultrasonography/methods
5.
Anaesthesist ; 61(7): 608-17, 2012 Jul.
Article in German | MEDLINE | ID: mdl-22772347

ABSTRACT

The development of modern critical care lung ultrasound is based on the classical representation of anatomical structures and the need for the assessment of specific sonography artefacts and phenomena. The air and fluid content of the lungs is interpreted using few typical artefacts and phenomena, with which the most important differential diagnoses can be made. According to a recent international consensus conference these include lung sliding, lung pulse, B-lines, lung point, reverberation artefacts, subpleural consolidations and intrapleural fluid collections. An increased number of B-lines is an unspecific sign for an increased quantity of fluid in the lungs resembling interstitial syndromes, for example in the case of cardiogenic pulmonary edema or lung contusion. In the diagnosis of interstitial syndromes lung ultrasound provides higher diagnostic accuracy (95%) than auscultation (55%) and chest radiography (72%). Diagnosis of pneumonia and pulmonary embolism can be achieved at the bedside by evaluating subpleural lung consolidations. Detection of lung sliding can help to detect asymmetrical ventilation and allows the exclusion of a pneumothorax. Ultrasound-based diagnosis of pneumothorax is superior to supine anterior chest radiography: for ultrasound the sensitivity is 92-100% and the specificity 91-100%. For the diagnosis of pneumothorax a simple algorithm was therefore designed: in the presence of lung sliding, lung pulse or B-lines, pneumothorax can be ruled out, in contrast a positive lung point is a highly specific sign of the presence of pneumothorax. Furthermore, lung ultrasound allows not only diagnosis of pleural effusion with significantly higher sensitivity than chest x-ray but also visual control in ultrasound-guided thoracocentesis.


Subject(s)
Critical Care/methods , Lung/diagnostic imaging , Acute Disease , Algorithms , Artifacts , Diagnosis, Differential , Humans , Lung Diseases/diagnostic imaging , Lung Diseases/therapy , Pleura/diagnostic imaging , Pneumonia/diagnosis , Pneumonia/diagnostic imaging , Pneumothorax/diagnosis , Pneumothorax/diagnostic imaging , Pulmonary Embolism/diagnosis , Pulmonary Embolism/diagnostic imaging , Radiography, Thoracic , Ultrasonography
8.
Anaesthesist ; 59(1): 53-61, 2010 Jan.
Article in German | MEDLINE | ID: mdl-20012427

ABSTRACT

Central venous line placement is a standard procedure in critical care and peri-operative medicine. This procedure can be associated with severe complications. In contrast to the landmark technique, ultrasound-guided punctures can significantly reduce the rate of complications. Patients with a high risk for difficult vascular access include critical care and emergency patients as well as patients on anticoagulation medication and dialysis. Placement of central venous catheters can be difficult in ventilated patients and if there has been prior surgery in the puncture area. In children and small infants central venous access can also be challenging due to the anatomical relationship in the head and neck region. Puncture techniques are explained briefly by means of ultrasound anatomy. Typical ultrasonographic images visualize pathological findings in order to identify dangers and complications in central venous catheterization.


Subject(s)
Catheterization, Central Venous/methods , Veins/diagnostic imaging , Adult , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Catheterization, Central Venous/adverse effects , Child , Critical Care , Emergency Medical Services , Femoral Vein/diagnostic imaging , Guidelines as Topic , Humans , Jugular Veins/diagnostic imaging , Respiration, Artificial , Subclavian Vein/diagnostic imaging , Ultrasonography
9.
Clin Exp Immunol ; 157(3): 370-6, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19664145

ABSTRACT

Interleukin (IL)-22 production triggered by innate immune mechanisms has been identified as key to efficient intestinal anti-bacterial host defence and preservation of homeostasis. We hypothesized that glucocorticoid therapy may impair IL-22 expression, which should promote intestinal epithelial damage with the potential of subsequent bacterial translocation. High-dose corticosteroid therapy in Crohn's disease has been associated with an increased rate of abscess formation and ultimately with a higher risk of developing postoperative infectious complications, including abdominal sepsis. Thus, we sought to investigate effects of the prototypic glucocorticoid dexamethasone on IL-22 production in the context of bacterial infection. Enhanced IL-22 plasma levels were detectable in rat sepsis. Moreover, heat-inactivated Staphylococcus epidermidis, used as a prototypic activator of innate immunity, induced robust production of IL-22 by human peripheral blood mononuclear cells (PBMC). Here, we report for the first time that dexamethasone mediates remarkable suppression of IL-22 as detected in S. epidermidis-activated PBMC and rat sepsis, respectively. The data presented herein suggest that insufficient IL-22 function may contribute to impaired intestinal host defence in the context of corticosteroid therapy.


Subject(s)
Dexamethasone/therapeutic use , Glucocorticoids/therapeutic use , Interleukins/immunology , Peritonitis/immunology , Staphylococcal Infections/immunology , Staphylococcus epidermidis , Animals , Case-Control Studies , Cells, Cultured , Depression, Chemical , Dexamethasone/analogs & derivatives , Gene Expression/drug effects , Humans , Interleukin-10/genetics , Interleukin-10/immunology , Interleukin-8/genetics , Interleukin-8/immunology , Interleukins/genetics , Male , Models, Animal , Peritonitis/drug therapy , RNA, Messenger/analysis , Random Allocation , Rats , Rats, Sprague-Dawley , Reverse Transcriptase Polymerase Chain Reaction/methods , Staphylococcal Infections/drug therapy , Interleukin-22
SELECTION OF CITATIONS
SEARCH DETAIL
...