1.
Commun Med (Lond) ; 1: 13, 2021.
Article in English | MEDLINE | ID: mdl-35602189

ABSTRACT

Background: In spring 2020, at the beginning of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic in Europe, we set up an assay system for large-scale testing of virus-specific and neutralising antibodies including their longevity. Methods: We analysed the sera of 1655 adult employees for SARS-CoV-2-specific antibodies using the S1 subunit of the spike protein of SARS-CoV-2. Sera containing S1-reactive antibodies were further evaluated for receptor-binding domain (RBD)- and nucleocapsid protein (NCP)-specific antibodies in relation to the neutralisation test (NT) results at three time points over six months. Results: We detect immunoglobulin G (IgG) and/or IgA antibodies reactive to the S1 protein in 10.15% (n = 168) of the participants. In total, 0.97% (n = 16) are positive for S1-IgG, 0.91% (n = 15) were S1-IgG- borderline and 8.28% (n = 137) exhibit only S1-IgA antibodies. Of the 168 S1-reactive sera, 8.33% (n = 14) have detectable RBD-specific antibodies and 6.55% (n = 11) NCP-specific antibodies. The latter correlates with NTs (kappa coefficient = 0.8660) but start to decline after 3 months. RBD-specific antibodies correlate most closely with the NT (kappa = 0.9448) and only these antibodies are stable for up to six months. All participants with virus-neutralising antibodies report symptoms, of which anosmia and/or dysgeusia correlate most closely with the detection of virus-neutralising antibodies. Conclusions: RBD-specific antibodies are most reliably detected post-infection, independent of the number/severity of symptoms, and correlate with neutralising antibodies at least for six months. They thus qualify best for large-scale seroepidemiological evaluation of both antibody reactivity and virus neutralisation.

2.
Water Res ; 159: 464-479, 2019 Aug 01.
Article in English | MEDLINE | ID: mdl-31128471

ABSTRACT

Cooling towers for heating, ventilation and air conditioning are ubiquitous in the built environment. Often located on rooftops, their semi-open water basins provide a suitable environment for microbial growth. They are recognized as a potential source of bacterial pathogens and have been associated with disease outbreaks such as Legionnaires' disease. While measures to minimize public health risks are in place, the general microbial and protist community structure and dynamics in these systems remain largely elusive. In this study, we analysed the microbiome of the bulk water from the basins of three cooling towers by 16S and 18S rRNA gene amplicon sequencing over the course of one year. Bacterial diversity in all three towers was broadly comparable to other freshwater systems, yet less diverse than natural environments; the most abundant taxa are also frequently found in freshwater or drinking water. While each cooling tower had a pronounced site-specific microbial community, taxa shared among all locations mainly included groups generally associated with biofilm formation. We also detected several groups related to known opportunistic pathogens, such as Legionella, Mycobacterium, and Pseudomonas species, albeit at generally low abundance. Although cooling towers represent a rather stable environment, microbial community composition was highly dynamic and subject to seasonal change. Protists are important members of the cooling tower water microbiome and known reservoirs for bacterial pathogens. Co-occurrence analysis of bacteria and protist taxa successfully captured known interactions between amoeba-associated bacteria and their hosts, and predicted a large number of additional relationships involving ciliates and other protists. Together, this study provides an unbiased and comprehensive overview of microbial diversity of cooling tower water basins, establishing a framework for investigating and assessing public health risks associated with these man-made freshwater environments.


Subject(s)
Legionella , Legionnaires' Disease , Microbiota , Humans , Seasons , Water , Water Microbiology
3.
Sci Rep ; 7(1): 3394, 2017 06 13.
Article in English | MEDLINE | ID: mdl-28611430

ABSTRACT

Free-living amoebae are well known for their role in controlling microbial community composition through grazing, but some groups, namely Acanthamoeba species, also frequently serve as hosts for bacterial symbionts. Here we report the first identification of a bacterial symbiont in the testate amoeba Cochliopodium. The amoeba was isolated from a cooling tower water sample and identified as C. minus. Fluorescence in situ hybridization and transmission electron microscopy revealed intracellular symbionts located in vacuoles. 16S rRNA-based phylogenetic analysis identified the endosymbiont as member of a monophyletic group within the family Coxiellaceae (Gammaprotebacteria; Legionellales), only moderately related to known amoeba symbionts. We propose to tentatively classify these bacteria as 'Candidatus Cochliophilus cryoturris'. Our findings add both, a novel group of amoeba and a novel group of symbionts, to the growing list of bacteria-amoeba relationships.


Subject(s)
Amebiasis/microbiology , Amoebida/classification , Coxiellaceae/physiology , Phylogeny , Symbiosis , Amoebida/isolation & purification , RNA, Bacterial/analysis , RNA, Ribosomal, 16S
4.
Parasitol Res ; 115(9): 3365-74, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27177720

ABSTRACT

Free-living amoebae (FLA) are widely spread in the environment and known to cause rare but often serious infections. Besides this, FLA may serve as vehicles for bacterial pathogens. In particular, Legionella pneumophila is known to replicate within FLA thereby also gaining enhanced infectivity. Cooling towers have been the source of outbreaks of Legionnaires' disease in the past and are thus usually screened for legionellae on a routine basis, not considering, however, FLA and their vehicle function. The aim of this study was to incorporate a screening system for host amoebae into a Legionella routine screening. A new real-time PCR-based screening system for various groups of FLA was established. Three cooling towers were screened every 2 weeks over the period of 1 year for FLA and Legionella spp., by culture and molecular methods in parallel. Altogether, 83.3 % of the cooling tower samples were positive for FLA, Acanthamoeba being the dominating genus. Interestingly, 69.7 % of the cooling tower samples were not suitable for the standard Legionella screening due to their high organic burden. In the remaining samples, positivity for Legionella spp. was 25 % by culture, but overall positivity was 50 % by molecular methods. Several amoebal isolates revealed intracellular bacteria.


Subject(s)
Amoeba/microbiology , Bacteria/isolation & purification , Fresh Water/microbiology , Fresh Water/parasitology , Amoeba/classification , Austria , Bacteria/classification , Bacteria/genetics , Disease Outbreaks
5.
J Eukaryot Microbiol ; 62(1): 3-11, 2015.
Article in English | MEDLINE | ID: mdl-25047131

ABSTRACT

Acanthamoebae are the causative agents of an often seriously progressing keratitis (AK) occurring predominantly in contact lens wearers and can cause several disseminating infections potentially resulting in granulomatous amoebic encephalitis (GAE) in the immunocompromised host. Our institution is the Austrian reference laboratory for Acanthamoeba diagnostics and the aim of this study was to give an overview of proven cases of Acanthamoeba infections in Austria during the past 20 yr. All samples of patients with suspected AK or GAE were screened for Acanthamoeba spp. by culture and/or PCR and the detected amoebae were genotyped. Altogether, 154 cases of AK and three cases of GAE were diagnosed. Age of the AK patients ranged from 8 to 82 yr (mean 37.8) and 58% of the patients were female. Approximately 89% of the AK patients were contact lens wearers, almost all cases were unilateral and 19% of the patients required a keratoplasty. Age of the GAE patients ranged from 2 to 25 yr (mean 14.7), all were HIV-negative, but two were severely immunosuppressed at the time of diagnosis. The predominant genotype in the AK cases was T4, other genotypes found were T3, T5, T6, T10 and T11. The three GAE cases involved genotypes T2, T4 and T5.


Subject(s)
Acanthamoeba Keratitis/diagnosis , Acanthamoeba/genetics , Amebiasis/diagnosis , Contact Lenses/parasitology , Encephalitis/diagnosis , Immunocompromised Host , Acanthamoeba/classification , Acanthamoeba/isolation & purification , Acanthamoeba Keratitis/immunology , Acanthamoeba Keratitis/parasitology , Acanthamoeba Keratitis/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Amebiasis/immunology , Amebiasis/parasitology , Amebiasis/surgery , Child , Child, Preschool , Corneal Transplantation/methods , Encephalitis/immunology , Encephalitis/parasitology , Encephalitis/surgery , Female , Genotype , Humans , Male , Middle Aged
6.
Eur J Protistol ; 50(4): 422-9, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25062389

ABSTRACT

Legionella pneumophila is known as the causative agent of Legionnaires' disease and free-living amoebae (FLA) can serve as vehicles for legionellae. The aim of this study was to screen industrial waters for the occurrence of FLA and their co-occurrence with legionellae. A total of 201 water samples, including 129 cooling waters and 72 process waters, and 30 cooling lubricants were included in the study. Treated waters were screened periodically, pre and post treatment. Altogether, 72.6% of the water samples were positive for FLA, acanthamoebae being most prevalent (in 23.9% of the samples) followed by Vermamoeba vermiformis (19.4%). Only one cooling lubricant was positive (Acanthamoeba genotype T4). Legionella spp. were detected in 34.8% of the water samples and in 15% in high concentrations (>1000 CFU/100 ml). Altogether, 81.4% of the Legionella-positive samples were positive for FLA by standard methods. By applying a highly sensitive nested PCR to a representative set of random samples it was revealed that Legionella spp. always co-occurred with Acanthamoeba spp. Although the addition of disinfectants did influence amoebal density and diversity, treated waters showed no difference concerning FLA in the interphases of disinfection. It appears that FLA can re-colonize treated waters within a short period of time.


Subject(s)
Amoeba/physiology , Fresh Water/microbiology , Fresh Water/parasitology , Legionella pneumophila/physiology , Water Microbiology , Amoeba/genetics , Amoeba/isolation & purification , Austria , Bacterial Load , Legionella pneumophila/isolation & purification , RNA, Ribosomal, 18S/genetics