Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Hum Vaccin Immunother ; 16(2): 452-459, 2020.
Article in English | MEDLINE | ID: mdl-31549899

ABSTRACT

We conducted a clinical trial to assess the safety and putative efficacy of an additional human rabies immune globulin (HRIG; KEDRAB) versus an older product (Comparator, HyperRAB S/D® [Grifols]) and determine whether HRIG interferes with development of endogenous antibodies versus Comparator, when each is given with an active rabies vaccine. This was a prospective, double-blind, single-period, non-inferiority study in which subjects were randomized (1:1) to a single dose (20 IU/kg) of HRIG or Comparator on day 0 and rabies vaccine (RabAvert® [GlaxoSmithKline]; 1 mL of ≥2.5 IU/mL) on days 0, 3, 7, 14, and 28. Anti-rabies antibodies were measured by rapid fluorescent focus inhibition test on day 14, and subjects were followed until day 185. Rabies virus neutralizing antibody (RVNA) titers ≥0.5 IU/mL were considered seroconversion putatively indicative of protection. The non-inferiority criterion was the lower limit of the 90% confidence interval (CI) >-10%, for the between-group difference in the proportion of subjects achieving RVNA ≥0.5 IU/mL. On day 14, 98.3% of 59 subjects in the HRIG group and 100% of 59 in the Comparator group had RVNA ≥0.5 IU/mL (difference between proportions - 1.8%; 90% CI, - 8.2, 3.1; non-inferiority criterion met). One subject in the HRIG group did not meet the seroconversion criteria for anti-rabies antibody, and one subject in the Comparator group showed an anamnestic response, with much higher than expected anti-rabies antibody levels at both baseline and on day 14. Thus, HRIG allows for prophylactic anti-rabies antibody titers and is non-inferior to Comparator, when administered with rabies vaccine.


Subject(s)
Rabies Vaccines , Rabies virus , Rabies , Antibodies, Viral , Healthy Volunteers , Humans , Post-Exposure Prophylaxis , Prospective Studies , Rabies/prevention & control , Rabies Vaccines/adverse effects
2.
J Pharmacol Exp Ther ; 359(3): 482-490, 2016 12.
Article in English | MEDLINE | ID: mdl-27821710

ABSTRACT

Life-long weekly infusions of human α1-antitrypsin (hAAT) are currently administered as augmentation therapy for patients with genetic AAT deficiency (AATD). Several recent clinical trials attempt to extend hAAT therapy to conditions outside AATD, including type 1 diabetes. Since the endpoint for AATD is primarily the reduction of risk for pulmonary emphysema, the present study explores hAAT dose protocols and routes of administration in attempt to optimize hAAT therapy for islet-related injury. Islet-grafted mice were treated with hAAT (Glassia™; i.p. or s.c.) under an array of clinically relevant dosing plans. Serum hAAT and immunocyte cell membrane association were examined, as well as parameters of islet survival. Results indicate that dividing the commonly prescribed 60 mg/kg i.p. dose to three 20 mg/kg injections is superior in affording islet graft survival; in addition, a short dynamic descending dose protocol (240→120→60→60 mg/kg i.p.) is comparable in outcomes to indefinite 60 mg/kg injections. While hAAT pharmacokinetics after i.p. administration in mice resembles exogenous hAAT treatment in humans, s.c. administration better imitated the physiological progressive rise of hAAT during acute phase responses; nonetheless, only the 60 mg/kg dose depicted an advantage using the s.c. route. Taken together, this study provides a platform for extrapolating an islet-relevant clinical protocol from animal models that use hAAT to protect islets. In addition, the study places emphasis on outcome-oriented analyses of drug efficacy, particularly important when considering that hAAT is presently at an era of drug-repurposing towards an extended list of clinical indications outside genetic AATD.

3.
IEEE Trans Inf Technol Biomed ; 8(4): 415-27, 2004 Dec.
Article in English | MEDLINE | ID: mdl-15615032

ABSTRACT

This paper describes an advanced care and alert portable telemedical monitor (AMON), a wearable medical monitoring and alert system targeting high-risk cardiac/respiratory patients. The system includes continuous collection and evaluation of multiple vital signs, intelligent multiparameter medical emergency detection, and a cellular connection to a medical center. By integrating the whole system in an unobtrusive, wrist-worn enclosure and applying aggressive low-power design techniques, continuous long-term monitoring can be performed without interfering with the patients' everyday activities and without restricting their mobility. In the first two and a half years of this EU IST sponsored project, the AMON consortium has designed, implemented, and tested the described wrist-worn device, a communication link, and a comprehensive medical center software package. The performance of the system has been validated by a medical study with a set of 33 subjects. The paper describes the main concepts behind the AMON system and presents details of the individual subsystems and solutions as well as the results of the medical validation.


Subject(s)
Diagnosis, Computer-Assisted/instrumentation , Information Storage and Retrieval/methods , Internet , Monitoring, Ambulatory/instrumentation , Signal Processing, Computer-Assisted/instrumentation , Telemedicine/instrumentation , Telemetry/instrumentation , Activities of Daily Living , Adolescent , Adult , Aged , Algorithms , Blood Pressure , Diagnosis, Computer-Assisted/methods , Equipment Design , Equipment Failure , Equipment Failure Analysis/methods , Feasibility Studies , Female , Heart Rate/physiology , Humans , Male , Medical Records Systems, Computerized , Middle Aged , Miniaturization/methods , Monitoring, Ambulatory/methods , Reproducibility of Results , Sensitivity and Specificity , Skin Temperature , Systems Integration , Telemedicine/methods , Telemetry/methods , Transducers
SELECTION OF CITATIONS
SEARCH DETAIL
...