Clin Chem Lab Med ; 60(5): 689-700, 2022 04 26.
Article in English | MEDLINE | ID: mdl-35073617

ABSTRACT

OBJECTIVES: The use of BD Vacutainer® Barricor™ tubes (BAR) can reduce turnaround time (TAT) and improve separation of plasma from cellular components using a specific mechanical separator. Concentrations of amino acids (AAs) and cytokines, known to be labile during pre-analytical time delays, were compared in heparin (BAR, BD Heparin standard tube [PST]), EDTA and serum gel tubes (SER) to validate previously identified quality indicators (QIs) in BAR. METHODS: Samples of healthy individuals (n=10) were collected in heparin, EDTA and SER tubes and exposed to varying pre- and post-centrifugation delays at room temperature (RT). Cytokines (interleukin [IL]-8, IL-16 and sCD40L) were analyzed by enzyme-linked immunosorbent assay (ELISA) and AAs were characterized by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). RESULTS: All QIs, AAs/AA ratio and cytokines increased during prolonged blood storage in heparin plasma (PST, BAR) and SER tubes. Comparison of 53 h/1 h pre-centrifugation delay resulted in an increase in taurine (Tau) and glutamic acid (Glu) concentrations by more than three times, soluble CD40L increased by 13.6, 9.2 and 4.3 fold in PST, BAR-CTRL and BAR-FAST, and IL-8 increased even more by 112.8 (PST), 266.1 (BAR-CTRL), 268.1 (BAR-FAST) and 70.0 (SER) fold, respectively. Overall, compared to prolonged blood storage, effects of post-centrifugation delays were less pronounced in all tested materials. CONCLUSIONS: BAR tubes are compatible with the use of several established QIs and can therefore be used in clinical biobanking to reduce pre-analytical TAT without compromising QIs and thus pre-analytical sample quality analysis.


Subject(s)
Amino Acids , Cytokines , Biological Specimen Banks , Blood Specimen Collection/methods , Chromatography, Liquid , Humans , Quality Indicators, Health Care , Tandem Mass Spectrometry
2.
Metabolites ; 11(9)2021 Sep 18.
Article in English | MEDLINE | ID: mdl-34564454

ABSTRACT

In clinical diagnostics and research, blood samples are one of the most frequently used materials. Nevertheless, exploring the chemical composition of human plasma and serum is challenging due to the highly dynamic influence of pre-analytical variation. A prominent example is the variability in pre-centrifugation delay (time-to-centrifugation; TTC). Quality indicators (QI) reflecting sample TTC are of utmost importance in assessing sample history and resulting sample quality, which is essential for accurate diagnostics and conclusive, reproducible research. In the present study, we subjected human blood to varying TTCs at room temperature prior to processing for plasma or serum preparation. Potential sample QIs were identified by Ultra high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) based metabolite profiling in samples from healthy volunteers (n = 10). Selected QIs were validated by a targeted MS/MS approach in two independent sets of samples from patients (n = 40 and n = 70). In serum, the hypoxanthine/guanosine (HG) and hypoxanthine/inosine (HI) ratios demonstrated high diagnostic performance (Sensitivity/Specificity > 80%) for the discrimination of samples with a TTC > 1 h. We identified several eicosanoids, such as 12-HETE, 15-(S)-HETE, 8-(S)-HETE, 12-oxo-HETE, (±)13-HODE and 12-(S)-HEPE as QIs for a pre-centrifugation delay > 2 h. 12-HETE, 12-oxo-HETE, 8-(S)-HETE, and 12-(S)-HEPE, and the HI- and HG-ratios could be validated in patient samples.

SELECTION OF CITATIONS
SEARCH DETAIL
...