Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 48
Filter
1.
Lung Cancer ; 187: 107427, 2024 01.
Article in English | MEDLINE | ID: mdl-38043395

ABSTRACT

AIM: Osimertinib is a third-generation epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor (TKI) approved for patients with EGFR mutated non-small cell lung cancer as first-line treatment. However, treatment resistance inevitably emerges and may present as oligo-progressive disease (OPD) or systemic progressive disease (SPD). The incidence of OPD on first-line osimertinib is unknown. METHODS: We retrospectively analyzed patients who received first-line osimertinib at 13 Swiss centers. The rate of OPD (PD in ≤ 5 lesions) and treatment outcomes were analyzed. RESULTS: The median age of the 148 patients was 68.2 years (range. 38.0-93.3). There were 62 % females, 83 % with a PS ≤ 1, 59 % never smokers, 57 % of patients with an EGFR exon 19 deletion and 37 % with EGFR p.L858R exon 21. 77 % experienced OPD. Median overall survival (OS) was 51.6 months (95 % CI, 38.4-65.0). Median progression-free survival (PFS) was 19.2 (95 % CI, 14.3-23.5) and 8.7 (95 % CI, 2.8-15.6) months for patients with common and uncommon EGFR mutations. Patients with OPD compared to SPD had a significantly longer time to treatment failure and longer OS of (22.9 vs. 10.8 months, p < 0.001 and 51.6 vs. 26.4 months, p = 0.004, respectively). The most common organ sites of PD were lung (62 %), brain (30 %), lymph nodes (30 %), bone (27 %) and pleura (27 %). Twenty-six patients (45 %) with OPD received local ablative treatment (LAT). The OS of OPD patients with LAT was 60.0 (95 % CI, 51.6-NA) vs. 51.4 (95 % CI 38.4-65.3) months (p = 0.43) without LAT. CONCLUSION: The rate of OPD of patients receiving first line osimertinib was 77 %. Patients with OPD had a significantly better OS compared to patients with SPD (51.6 vs. 26.4 months). Patients with OPD receiving LAT had the longest median OS (60.0 months).


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Female , Humans , Male , Carcinoma, Non-Small-Cell Lung/drug therapy , Carcinoma, Non-Small-Cell Lung/genetics , Lung Neoplasms/drug therapy , Lung Neoplasms/genetics , Cohort Studies , Retrospective Studies , Switzerland , Protein Kinase Inhibitors/pharmacology , Aniline Compounds/therapeutic use , ErbB Receptors/genetics , Mutation
2.
J Synchrotron Radiat ; 29(Pt 5): 1299-1308, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-36073890

ABSTRACT

The SASE3 soft X-ray beamline at the European XFEL has been designed and built to provide experiments with a pink or monochromatic beam in the photon energy range 250-3000 eV. Here, the focus is monochromatic operation of the SASE3 beamline, and the design and performance of the SASE3 grating monochromator are reported. The unique capability of a free-electron laser source to produce short femtosecond pulses of a high degree of coherence challenges the monochromator design by demanding control of both photon energy and temporal resolution. The aim to transport close to transform-limited pulses poses very high demands on the optics quality, in particular on the grating. The current realization of the SASE3 monochromator is discussed in comparison with optimal design performance. At present, the monochromator operates with two gratings: the low-resolution grating is optimized for time-resolved experiments and allows for moderate resolving power of about 2000-5000 along with pulse stretching of a few to a few tens of femtoseconds RMS, and the high-resolution grating reaches a resolving power of 10 000 at the cost of larger pulse stretching.


Subject(s)
Photons , Synchrotrons , Lasers , Radiography , X-Rays
3.
Sci Rep ; 10(1): 9836, 2020 06 17.
Article in English | MEDLINE | ID: mdl-32555309

ABSTRACT

A cross-linking technique involving application of Bacteriochlorophyll Derivative WST-11 mixed with dextran (WST-D) to the epithelium-debrided cornea and illumination with Near Infrared (NIR), has been identified as a promising therapy for stiffening pathologically weakened corneas. To investigate its effect on corneal collagen architecture, x-ray scattering and electron microscopy data were collected from paired WST-D/NIR treated and untreated rabbit corneas. The treated eye received 2.5 mg/mL WST-D and was illuminated by a NIR diode laser (755 nm, 10 mW/cm2). An increase in corneal thickness (caused by corneal oedema) occurred at 1-day post-treatment but resolved in the majority of cases within 4 days. The epithelium was fully healed after 6-8 days. X-ray scattering revealed no difference in average collagen interfibrillar spacing, fibril diameter, D-periodicity or intermolecular spacing between treated and untreated specimens. Similarly, electron microscopy images of the anterior and posterior stroma in healed WST-D/NIR corneas and untreated controls revealed no obvious differences in collagen organisation or fibril diameter. As the size and organisation of stromal collagen is closely associated with the optical properties of the cornea, the absence of any large-scale changes following treatment confirms the potential of WST-D/NIR therapy as a means of safely stiffening the cornea.


Subject(s)
Bacteriochlorophylls/pharmacology , Corneal Stroma/drug effects , Corneal Stroma/radiation effects , Infrared Rays , Animals , Collagen/metabolism , Corneal Stroma/metabolism , Corneal Stroma/ultrastructure , Lasers , Microscopy, Electron , Rabbits
4.
Photodiagnosis Photodyn Ther ; 20: 165-168, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28887222

ABSTRACT

AIMS: To evaluate the accuracy of contrast-enhanced ultrasound (CEUS) for monitoring tumor necrosis following WST-11 vascular targeted photodynamic therapy (VTP) using imaging-pathology correlation. METHODS: Renal adenocarcinoma cells were injected into the hindlimb of 13 BalB/c mice resulting in tumors ranging from 9.8 to 194.3mm3. US guidance was used to place a laser fiber into the tumor, and VTP was performed. CEUS was performed prior to animal sacrifice, 24h post-VTP. Whole tumors were extracted for histopathologic analysis using H&E and TUNEL staining. Pathology samples corresponding to the CEUS imaging plane were prepared in order to compare the size and extents of tumor necrosis. RESULTS: Tumor necrosis following VTP appeared as a central region of non-enhancement on CEUS, while viable tumor appeared as patchy regions of enhancement in the tumor periphery. The region of tumor necrosis measured in mean 66% and 64.8% of total tumor area on CEUS and pathology respectively (p=0.2). The size and location of the necrosis on CEUS images and pathology samples were found correlative with no inter-observer difference (weighted kappa of 0.771 and 0.823, respectively). CONCLUSION: CEUS allows accurate monitoring of VTP induced tumor necrosis in a small animal model.


Subject(s)
Neoplasms/diagnostic imaging , Neoplasms/drug therapy , Photochemotherapy/methods , Ultrasonography/methods , Animals , Disease Models, Animal , Mice , Mice, Inbred BALB C , Neoplasms/pathology
5.
Phys Rev Lett ; 117(2): 027401, 2016 Jul 08.
Article in English | MEDLINE | ID: mdl-27447522

ABSTRACT

X-ray diffractive imaging with laterally coherent x-ray free-electron laser (XFEL) pulses is increasingly utilized to obtain ultrafast snapshots of matter. Here we report the amazing disappearance of single-shot charge and magnetic diffraction patterns recorded with resonantly tuned, narrow bandwidth XFEL pulses. Our experimental results reveal the exquisite sensitivity of single-shot charge and magnetic diffraction patterns of a magnetic film to the onset of field-induced stimulated elastic x-ray forward scattering. The loss in diffraction contrast, measured over 3 orders of magnitude in intensity, is in remarkable quantitative agreement with a recent theory that is extended to include diffraction.

6.
Phys Rev Lett ; 116(1): 019902, 2016 Jan 08.
Article in English | MEDLINE | ID: mdl-26799050

ABSTRACT

This corrects the article DOI: 10.1103/PhysRevLett.115.107402.

7.
Phys Rev Lett ; 115(10): 107402, 2015 Sep 04.
Article in English | MEDLINE | ID: mdl-26382702

ABSTRACT

X-ray absorption by matter has long been described by the famous Beer-Lambert law. Here, we show how this fundamental law needs to be modified for high-intensity coherent x-ray pulses, now available at x-ray free electron lasers, due to the onset of stimulated elastic forward scattering. We present an analytical expression for the modified polarization-dependent Beer-Lambert law for the case of resonant core-to-valence electronic transitions and incident transform limited x-ray pulses. Upon transmission through a solid, the resonant absorption and dichroic contrasts are found to vanish with increasing x-ray intensity, with the stimulation threshold lowered by orders of magnitude through a resonant superradiantlike effect. Our results have broad implications for the study of matter with x-ray lasers.


Subject(s)
Models, Theoretical , X-Ray Diffraction , Circular Dichroism/methods , Cobalt/chemistry , Elasticity , Iron/chemistry , Magnetics/methods , Nickel/chemistry
8.
World J Urol ; 33(7): 945-53, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25712310

ABSTRACT

PURPOSE: To evaluate the 6-month effects of the recommended drug and light dosage in focal vascular-targeted photodynamic therapy (VTP) using TOOKAD(®) Soluble in patients with localized prostate cancer (LPCa). METHODS: We performed a pooled analysis of 117 men with LPCa, PSA <10 ng/mL, and Gleason score ≤ 7 (3 + 4), from 3 studies who received a 10-min intravenous infusion of a single dose of 4 mg/kg TOOKAD(®) Soluble, activated by a 753-nm light at 200 J/cm delivered in the prostate by transperineal fibres under transrectal ultrasound guidance. Primary endpoint was 6-month negative biopsies in the treated lobe(s). PSA was measured at month 1, 3, and 6. Magnetic resonance imaging was performed at day 7, month 3, and 6. International Prostate Symptom Score (IPSS), International Index of Erectile Function (IIEF-5) and adverse events were reported at day 7, month 1, 3, and 6. RESULTS: Month 6 negative biopsy rate was 68.4 % in the overall evaluable population (N = 114) and 80.6 % for patients treated by hemiablation with light density index (LDI) ≥ 1 (N = 67). Mean prostate necroses at week-1 were 76.5 and 86.3 %, respectively. In both groups, PSA levels at month 6 decreased by 2.0 ng/mL. Small changes from baseline for IPSS and IIEF-5 indicated a slight improvement in urinary function and a slight deterioration in sexual function. CONCLUSIONS: Focal VTP treatment with TOOKAD(®) Soluble at 4 mg/kg and 200 J/cm resulted in a negative 6-month biopsy rate of 68.4 % for the whole population and 80.6 % for patients treated by hemiablation with LDI ≥ 1. The treatment was well tolerated. Two phase III studies will reach completion in early 2015.


Subject(s)
Bacteriochlorophylls/therapeutic use , Photochemotherapy/methods , Photosensitizing Agents/therapeutic use , Prostatic Neoplasms/drug therapy , Clinical Trials, Phase II as Topic , Humans , Male , Treatment Outcome
9.
Nat Mater ; 12(10): 882-6, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23892787

ABSTRACT

As the oldest known magnetic material, magnetite (Fe3O4) has fascinated mankind for millennia. As the first oxide in which a relationship between electrical conductivity and fluctuating/localized electronic order was shown, magnetite represents a model system for understanding correlated oxides in general. Nevertheless, the exact mechanism of the insulator-metal, or Verwey, transition has long remained inaccessible. Recently, three-Fe-site lattice distortions called trimerons were identified as the characteristic building blocks of the low-temperature insulating electronically ordered phase. Here we investigate the Verwey transition with pump-probe X-ray diffraction and optical reflectivity techniques, and show how trimerons become mobile across the insulator-metal transition. We find this to be a two-step process. After an initial 300 fs destruction of individual trimerons, phase separation occurs on a 1.5±0.2 ps timescale to yield residual insulating and metallic regions. This work establishes the speed limit for switching in future oxide electronics.

10.
Nat Mater ; 12(4): 293-8, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23503010

ABSTRACT

Ultrafast laser techniques have revealed extraordinary spin dynamics in magnetic materials that equilibrium descriptions of magnetism cannot explain. Particularly important for future applications is understanding non-equilibrium spin dynamics following laser excitation on the nanoscale, yet the limited spatial resolution of optical laser techniques has impeded such nanoscale studies. Here we present ultrafast diffraction experiments with an X-ray laser that probes the nanoscale spin dynamics following optical laser excitation in the ferrimagnetic alloy GdFeCo, which exhibits macroscopic all-optical switching. Our study reveals that GdFeCo displays nanoscale chemical and magnetic inhomogeneities that affect the spin dynamics. In particular, we observe Gd spin reversal in Gd-rich nanoregions within the first picosecond driven by the non-local transfer of angular momentum from larger adjacent Fe-rich nanoregions. These results suggest that a magnetic material's microstructure can be engineered to control transient laser-excited spins, potentially allowing faster (~ 1 ps) spin reversal than in present technologies.

11.
Phys Rev Lett ; 109(6): 065002, 2012 Aug 10.
Article in English | MEDLINE | ID: mdl-23006275

ABSTRACT

We have used the Linac Coherent Light Source to generate solid-density aluminum plasmas at temperatures of up to 180 eV. By varying the photon energy of the x rays that both create and probe the plasma, and observing the K-α fluorescence, we can directly measure the position of the K edge of the highly charged ions within the system. The results are found to disagree with the predictions of the extensively used Stewart-Pyatt model, but are consistent with the earlier model of Ecker and Kröll, which predicts significantly greater depression of the ionization potential.

12.
Rev Sci Instrum ; 83(4): 043107, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22559515

ABSTRACT

The soft x-ray materials science instrument is the second operational beamline at the linac coherent light source x-ray free electron laser. The instrument operates with a photon energy range of 480-2000 eV and features a grating monochromator as well as bendable refocusing mirrors. A broad range of experimental stations may be installed to study diverse scientific topics such as: ultrafast chemistry, surface science, highly correlated electron systems, matter under extreme conditions, and laboratory astrophysics. Preliminary commissioning results are presented including the first soft x-ray single-shot energy spectrum from a free electron laser.

13.
Nature ; 482(7383): 59-62, 2012 Jan 25.
Article in English | MEDLINE | ID: mdl-22278059

ABSTRACT

Matter with a high energy density (>10(5) joules per cm(3)) is prevalent throughout the Universe, being present in all types of stars and towards the centre of the giant planets; it is also relevant for inertial confinement fusion. Its thermodynamic and transport properties are challenging to measure, requiring the creation of sufficiently long-lived samples at homogeneous temperatures and densities. With the advent of the Linac Coherent Light Source (LCLS) X-ray laser, high-intensity radiation (>10(17) watts per cm(2), previously the domain of optical lasers) can be produced at X-ray wavelengths. The interaction of single atoms with such intense X-rays has recently been investigated. An understanding of the contrasting case of intense X-ray interaction with dense systems is important from a fundamental viewpoint and for applications. Here we report the experimental creation of a solid-density plasma at temperatures in excess of 10(6) kelvin on inertial-confinement timescales using an X-ray free-electron laser. We discuss the pertinent physics of the intense X-ray-matter interactions, and illustrate the importance of electron-ion collisions. Detailed simulations of the interaction process conducted with a radiative-collisional code show good qualitative agreement with the experimental results. We obtain insights into the evolution of the charge state distribution of the system, the electron density and temperature, and the timescales of collisional processes. Our results should inform future high-intensity X-ray experiments involving dense samples, such as X-ray diffractive imaging of biological systems, material science investigations, and the study of matter in extreme conditions.

14.
Phys Rev Lett ; 109(24): 245003, 2012 Dec 14.
Article in English | MEDLINE | ID: mdl-23368333

ABSTRACT

The x-ray intensities made available by x-ray free electron lasers (FEL) open up new x-ray matter interaction channels not accessible with previous sources. We report here on the resonant generation of Kα emission, that is to say the production of copious Kα radiation by tuning the x-ray FEL pulse to photon energies below that of the K edge of a solid aluminum sample. The sequential absorption of multiple photons in the same atom during the 80 fs pulse, with photons creating L-shell holes and then one resonantly exciting a K-shell electron into one of these holes, opens up a channel for the Kα production, as well as the absorption of further photons. We demonstrate rich spectra of such channels, and investigate the emission produced by tuning the FEL energy to the K-L transitions of those highly charged ions that have transition energies below the K edge of the cold material. The spectra are sensitive to x-ray intensity dependent opacity effects, with ions containing L-shell holes readily reabsorbing the Kα radiation.

15.
Phys Rev Lett ; 107(14): 144801, 2011 Sep 30.
Article in English | MEDLINE | ID: mdl-22107200

ABSTRACT

Measurements of the spatial and temporal coherence of single, femtosecond x-ray pulses generated by the first hard x-ray free-electron laser, the Linac Coherent Light Source, are presented. Single-shot measurements were performed at 780 eV x-ray photon energy using apertures containing double pinholes in "diffract-and-destroy" mode. We determined a coherence length of 17 µm in the vertical direction, which is approximately the size of the focused Linac Coherent Light Source beam in the same direction. The analysis of the diffraction patterns produced by the pinholes with the largest separation yields an estimate of the temporal coherence time of 0.55 fs. We find that the total degree of transverse coherence is 56% and that the x-ray pulses are adequately described by two transverse coherent modes in each direction. This leads us to the conclusion that 78% of the total power is contained in the dominant mode.

16.
Opt Lett ; 34(5): 650-2, 2009 Mar 01.
Article in English | MEDLINE | ID: mdl-19252581

ABSTRACT

We propose and demonstrate a method to gauge and optimize the signal-to-noise ratios (SNRs) in lensless imaging using partially coherent sources. Through spatial filtering we tuned the coherence width of an incoherent soft x-ray undulator source, and we deduce that there exists an optimal spatial filter setting for imaging micrometer-sized objects, while high-resolution imaging is best executed without spatial filtering. Our SNR analysis, given spatial coherence, allows for an estimation of the required exposure time at synchrotron sources and pulse fluence at x-ray laser sources.

17.
Phys Rev Lett ; 101(7): 076101, 2008 Aug 15.
Article in English | MEDLINE | ID: mdl-18764556

ABSTRACT

The methodology of multiple-wavelength anomalous diffraction, widely used for macromolecular structure determination, is extended to the imaging of nonperiodic nanostructures. We demonstrate the solution of the phase problem by a combination of two resonantly recorded coherent scattering patterns at the carbon K edge (285 eV). Our approach merges iterative phase retrieval and x-ray holography approaches, yielding unique and rapid reconstructions. The element, chemical, and magnetic state specificity of our method further renders it widely applicable to a broad range of nanostructures, providing a spatial resolution that is limited, in principle, by wavelength only.

18.
Hum Reprod ; 23(7): 1491-8, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18287105

ABSTRACT

BACKGROUND: To test the feasibility of photodynamic therapy (PDT)-based ablation of rat embryos as a model for PDT of extrauterine pregnancy (EUP) in humans. METHODS: A controlled pre-clinical study. Selected rat embryos [one per litter, n = 30, embryonic day 14 (E14)] were subjected to placental injection of a Palladium-bacteriochlorophyll derivative and illuminated to achieve selective photo-ablation. Histopathology studies were performed 48 h after treatment (E16). Parturition (E21) and breeding (approximately 12 weeks) after treatment were also evaluated. RESULTS: Using direct placental injection, nearly 80% of the treated rat embryos were selectively photo-ablated, leaving the remaining litter unharmed to achieve normal parturition. Treated animals retained fertility and normally implanted in both treated and untreated uterine horns attesting to the confined toxicity inherent to this approach. CONCLUSIONS: Although requiring respective adaptation to clinical application in terms of treatment protocols and designated hardware, photodynamic interventions using novel bacteriochlorophyll-based photosensitizers may prove applicable to treatment of EUP, as well as other gynecological pathologies and malignancies in a safe, minimally invasive manner.


Subject(s)
Abortion, Induced/methods , Photochemotherapy/methods , Animals , Bacteriochlorophylls/therapeutic use , Female , Fertility , Models, Animal , Photosensitizing Agents/therapeutic use , Pregnancy , Pregnancy Outcome , Pregnancy, Ectopic/drug therapy , Rats , Rats, Wistar
19.
J Urol ; 178(5): 1974-9; discussion 1979, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17869307

ABSTRACT

PURPOSE: Tookad is a novel intravascular photosensitizer. When activated by 763 nm light, it destroys tumors by damaging their blood supply. It then clears rapidly from the circulatory system. To our knowledge we report the first application of Tookad vascular targeted photodynamic therapy in humans. We assessed the safety, pharmacokinetics and preliminary treatment response as a salvage procedure after external beam radiation therapy. MATERIALS AND METHODS: Patients received escalating drug doses of 0.1 to 2 mg/kg at a fixed light dose of 100 J/cm or escalated light doses of 230 and 360 J/cm at the 2 mg/kg dose. Four optical fibers were placed transperineally in the prostate, including 2 for light delivery and 2 for light dosimetry. Treatment response was assessed primarily by hypovascular lesion formation on contrast enhanced magnetic resonance imaging and transrectal ultrasound guided biopsies targeting areas of lesion formation and secondarily by serum prostate specific antigen changes. RESULTS: Tookad vascular targeted photodynamic therapy was technically feasible. The plasma drug concentration was negligible by 2 hours after infusion. In the drug escalation arm 3 of 6 patients responded, as seen on magnetic resonance imaging, including 1 at 1 mg/kg and 2 at 2 mg/kg. The light dose escalation demonstrated an increasing volume of effect with 2 of 3 patients in the first light escalation cohort responding and all 6 responding at the highest light dose with lesions encompassing up to 70% of the peripheral zone. There were no serious adverse events, and continence and potency were maintained. CONCLUSIONS: Tookad vascular targeted photodynamic therapy salvage therapy is safe and well tolerated. Lesion formation is strongly drug and light dose dependent. Early histological and magnetic resonance imaging responses highlight the clinical potential of Tookad vascular targeted photodynamic therapy to manage post-external beam radiation therapy recurrence.


Subject(s)
Bacteriochlorophylls/administration & dosage , Brachytherapy/methods , Neoplasm Recurrence, Local/drug therapy , Photochemotherapy/methods , Prostatic Neoplasms/therapy , Bacteriochlorophylls/pharmacokinetics , Biopsy , Dose-Response Relationship, Drug , Humans , Infusions, Intravenous , Magnetic Resonance Imaging , Male , Neoplasm Recurrence, Local/blood , Neoplasm Recurrence, Local/radiotherapy , Prostate/blood supply , Prostate/diagnostic imaging , Prostate/pathology , Prostate-Specific Antigen/blood , Prostatic Neoplasms/blood , Prostatic Neoplasms/blood supply , Tomography, X-Ray Computed , Treatment Outcome
20.
Phys Rev Lett ; 95(25): 253006, 2005 Dec 16.
Article in English | MEDLINE | ID: mdl-16384459

ABSTRACT

The 2p-3d core-hole interaction in the L2.3 absorption spectra of the transition metals is treated within time-dependent density functional theory. A simple three-level model explains the origin of the strong deviations from the one-particle branching ratio and yields matrix elements of the unknown exchange-correlation kernel directly from experiment.

SELECTION OF CITATIONS
SEARCH DETAIL
...