Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
Knee ; 24(1): 9-15, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27836691

ABSTRACT

BACKGROUND: The purpose of the study was to evaluate the intra- and inter-observer reliabilities of the Genovese grading on MRI in patients after collagen meniscus substitution. METHODS: 84 MRI images of 74 consecutive patients who underwent partial meniscus substitution using collagen meniscus implant (CMI) were assessed. MRIs were evaluated using the Genovese grading system. Furthermore, meniscal extrusion was assessed. Two observers performed the grading twice, blinded to each other and to the previous results, with a six weeks interval. The inter- and intra-observer reliabilities were assessed using kappa and weighted kappa values. RESULTS: The criterion "morphology/size" showed a weighted kappa value inter-observer reliability of 0.069 (rater 1)/0.352 (rater 2) and intra-observer reliability of 0.170 (1st rating)/0.582 (2nd rating). The criterion "signal intensity" showed a weighted kappa value inter-observer reliability of 0.175/0.284 and intra-observer reliability of 0.294/0.458. The criterion "cartilage lesions" showed a kappa value inter-observer reliability of 0.091/0.525 and intra-observer reliability of 0.409/0.413. The criterion "bone marrow edema" showed a kappa value inter-observer reliability of 0.667/0.808 and intra-observer reliability of 0.702/0.715. The criterion "cartilage lesions" showed a kappa value inter-observer reliability of 0.091/0.525 and intra-observer reliability of 0.409/0.413. Regarding meniscal extrusion kappa values for the inter-observer reliability were 0.625/0.940 and 0.625/0.889 for intra-observer reliability. CONCLUSIONS: Three of the four Genovese grading items showed only slight to moderate inter- and intra-observer reliabilities in evaluating CMI on MRI. Hence, such grading results need to be considered with all due care. Only the criteria "bone marrow edema" and "meniscal extrusion" showed a good agreement for both inter- and intra-observer reliabilities.


Subject(s)
Collagen , Joint Diseases/diagnostic imaging , Magnetic Resonance Imaging , Menisci, Tibial/diagnostic imaging , Menisci, Tibial/surgery , Prostheses and Implants , Adult , Female , Humans , Joint Diseases/etiology , Joint Diseases/surgery , Male , Middle Aged , Observer Variation , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...