1.
J Breath Res ; 16(4)2022 06 28.
Article in English | MEDLINE | ID: mdl-35688126

ABSTRACT

The analysis of human breath is a very active area of research, driven by the vision of a fast, easy, and non-invasive tool for medical diagnoses at the point of care. Millimeter-wave gas spectroscopy (MMWGS) is a novel, well-suited technique for this application as it provides high sensitivity, specificity and selectivity. Most of all, it offers the perspective of compact low-cost systems to be used in doctors' offices or hospitals. In this work, we demonstrate the analysis of breath samples acquired in a medical environment using MMWGS and evaluate validity, reliability, as well as limitations and perspectives of the method. To this end, we investigated 28 duplicate samples from chronic obstructive lung disease patients and compared the results to gas chromatography-mass spectrometry (GC-MS). The quantification of the data was conducted using a calibration-free fit model, which describes the data precisely and delivers absolute quantities. For ethanol, acetone, and acetonitrile, the results agree well with the GC-MS measurements and are as reliable as GC-MS. The duplicate samples deviate from the mean values by only 6% to 18%. Detection limits of MMWGS depend strongly on the molecular species. For example, acetonitrile can be traced down to 1.8 × 10-12mol by the MMWGS system, which is comparable to the GC-MS system. We observed correlations of abundances between formaldehyde and acetaldehyde as well as between acetonitrile and acetaldehyde, which demonstrates the potential of MMWGS for breath research.


Subject(s)
Breath Tests , Pulmonary Disease, Chronic Obstructive , Acetaldehyde , Acetonitriles , Breath Tests/methods , Gas Chromatography-Mass Spectrometry/methods , Gases , Humans , Pulmonary Disease, Chronic Obstructive/diagnosis , Reproducibility of Results , Spectrum Analysis
2.
Sensors (Basel) ; 19(12)2019 Jun 17.
Article in English | MEDLINE | ID: mdl-31212999

ABSTRACT

Breath gas analysis is a promising tool for medical research and diagnosis. A particularly powerful technological approach is millimeter-wave/terahertz (mmW/THz) spectroscopy, because it is a very sensitive and highly selective technique. In addition, it offers the potential for compact and affordable sensing systems for wide use. In this work, we demonstrate the capability of a mmW/THz spectrometer for breath analysis. Samples from three volunteers and a sample from ambient air were analyzed with respect to 31 different molecular species. High-resolution absorption spectra were measured by scanning two absorption lines from each species. Out of the 31, a total of 21 species were detected. The results demonstrate the potential of mmW/THz spectroscopy for breath analysis.


Subject(s)
Breath Tests/methods , Gases/analysis , Terahertz Spectroscopy/methods , Electromagnetic Phenomena , Humans , Refractometry/methods