Radiography (Lond) ; 29(1): 19-27, 2023 01.
Article in English | MEDLINE | ID: mdl-36209641

ABSTRACT

INTRODUCTION: The aim of this study was to evaluate the influence of a noise optimized virtual monoenergetic reconstruction algorithm (VMI+) on the image quality and assessability of dual energy (DE) computed tomography angiography (CTA) of the lower extremity runoff. METHODS: A total of 118 lower extremity runoff CTA performed on a 3rd generation DE-CT scanner in 109 patients (54 females; 75.6 ± 9.5 years) were included in this retrospective study. Axial image stacks were reconstructed with a standard 120 kV setting and VMI+ of different keV levels. Objective image quality criteria (contrast attenuation, signal-to-noise [SNR] and contrast-to-noise ratio [CNR]) were measured. Two radiologists evaluated subjective image quality regarding intraluminal attenuation and image noise using a 5-point Likert scale. Diagnostic accuracy for significant stenosis (>75%) and vessel occlusion was assessed for 120 kV and 50 keV VMI+ images rated by two radiologists. In all patients, a digital subtraction angiography (DSA) rated by on board-certified radiologist served as the standard of reference. RESULTS: Intraluminal attenuation was highest in 40/50 keV VMI+ while SNR were similar to 120 kV images. In subjective assessment, intraluminal contrast of 50 keV images was deemed superior compared to 120 kV despite higher image noise. Sensitivity, specificity, and accuracy for detection of a vessel occlusion were similar in 50 keV VMI+ compared to 120 kV (70%/92%/84%; 70%/91%/83%; p < 0.001) but 13 of 118 (11%) lower leg runoffs were only assessable with 50 keV VMI+. CONCLUSION: VMI+ reconstructions improve assessability of DE-CTA by increased luminal attenuation with consistent image noise, also allowing the evaluation of lower leg arterial segments inassessable with standard reconstructions. IMPLICATIONS FOR PRACTICE: Providing higher intraluminal attenuation and similar image noise compared with conventional reconstructions, 50 keV VMI+ may be appropriate for routine evaluation of DE-CTA.


Subject(s)
Computed Tomography Angiography , Radiography, Dual-Energy Scanned Projection , Female , Humans , Computed Tomography Angiography/methods , Leg/diagnostic imaging , Signal-To-Noise Ratio , Retrospective Studies , Radiography, Dual-Energy Scanned Projection/methods , Lower Extremity/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...