Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Radiol Prot ; 43(1)2023 02 21.
Article in English | MEDLINE | ID: mdl-36745918

ABSTRACT

In order to evaluate the localised magnetic field (MF) exposure of the cashier's hand due to a particular demagnetization device (deactivator) for single-use labels of an acoustomagnetic (AM) electronic article surveillance (EAS) system, comprehensive measurements of the MF near the surface of the deactivator, and numerical computations of the induced electric field strengthEi, were performed in high-resolution anatomical hand models of different postures and positions with respect to the deactivator. The measurement results for magnetic inductionBwere assessed with respect to the action levels (AL) for limb exposure, and the computational results forEiwere evaluated with respect to the exposure limit values (ELV) for health effects according to European Union (EU) directive 2013/35/EU. For the ELV-based assessment, a maximum of the 2 × 2 × 2 mm3averagedEi(maxEi,avg) and the respective 99.9th, 99.5th, and 99.0th percentiles were used. As the MF impulse emitted by the deactivator for demagnetization of the AM-EAS labels was highly nonsinusoidal, measurement results were assessed based on the weighted peak method in the time domain (WPM-TD). A newly developed scaling technique was proposed to also apply the WPM-TD to the assessment of the (nonsinusoidal)Eiregarding the ELV. It was used to calculate the resulting WPM-TD-based exposure index (EI) from frequency domain computations. The assessment regarding the AL for limbs yielded peak values of magnetic induction of up to 97 mT (measured with a 3 cm2MF probe on top of the deactivator surface) corresponding to an EI of 443%. However, this was considered an overestimation of the actual exposure in terms ofEias the AL were intentionally defined conservatively. A WPM-TD-based assessment ofEifinally led to the worst case EI of up to 135%, 93%, 78%, and 72% when using the maxEi,avg, 99.9th, 99.5th, and 99.0th percentiles, respectively.


Subject(s)
Electricity , Occupational Exposure , Magnets , Models, Anatomic , European Union , Electromagnetic Fields , Magnetic Fields
2.
Sci Rep ; 11(1): 6039, 2021 03 16.
Article in English | MEDLINE | ID: mdl-33727602

ABSTRACT

Multifunctional nanoparticles are discussed as versatile probes for homogeneous immunoassays for in-vitro diagnostics. Top-down fabrication allows to combine and tailor magnetic and plasmonic anisotropic properties. The combination of nanoimprint lithography, thin film deposition, and lift-off processing provides a top-down fabrication platform, which is both flexible and reliable. Here, we discuss the material compositions and geometrical designs of monodisperse multicomponent nanoparticles and their consequences on optical and magnetic properties. The rotational hydrodynamics of nanoparticles is measured and considered under the influence of magnetic shape anisotropy in the framework of the Stoner-Wohlfarth theory. The plasmon-optical properties are explained by discrete-dipole finite-element simulations. Rotational dynamical measurements of imprinted nanoprobes for two test proteins demonstrate the applicability as highly sensitive biomolecular nanoprobes.

3.
Med Biol Eng Comput ; 59(1): 107-119, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33269461

ABSTRACT

Electric contact currents (CC) can cause muscle contractions, burns, or ventricular fibrillation which may result in life-threatening situations. In vivo studies with CC are rare due to potentially hazardous effects for participants. Cadaver studies are limited to the range of tissue's electrical properties and the utilized probes' size, relative position, and sensitivity. Thus, the general safety standards for protection against CC depend on a limited scientific basis. The aim of this study was therefore to develop an extendable and adaptable validated numerical body model for computational CC dosimetry for frequencies between DC and 1 MHz. Applying the developed model for calculations of the IEC heart current factors (HCF) revealed that in the case of transversal CCs, HCFs are frequency dependent, while for longitudinal CCs, the HCFs seem to be unaffected by frequency. HCFs for current paths from chest or back to hand appear to be underestimated by the International Electrotechnical Commission (IEC 60479-1). Unlike the HCFs provided in IEC 60479-1 for longitudinal current paths, our work predicts the HCFs equal 1.0, possibly due to a previously unappreciated current flow through the blood vessels. However, our results must be investigated by further research in order to make a definitive statement. Contact currents of frequencies from DC up to 100 kHz were conducted through the numerical body model Duke by seven contact electrodes on longitudinal and transversal paths. The resulting induced electric field and current enable the evaluation of the body impedance and the heart current factors for each frequency and current path.


Subject(s)
Electricity , Radiometry , Computer Simulation , Electric Impedance , Electrodes , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...