Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Ultrasound Obstet Gynecol ; 30(5): 706-14, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17712870

ABSTRACT

OBJECTIVES: To determine the clinical significance of the presence of amniotic fluid (AF) 'sludge' among asymptomatic patients at high risk for spontaneous preterm delivery. METHODS: This retrospective case-control study included 281 patients with (n = 66) or without (n = 215) AF 'sludge', who underwent transvaginal ultrasound examination between 13 and 29 completed weeks of gestation. Patients with threatened preterm labor, multiple gestation, fetal anomalies, placenta previa or uterine contractions were excluded. RESULTS: The prevalence of AF 'sludge' in the study population was 23.5% (66/281). The rates of spontaneous preterm delivery at < 28 weeks, < 32 weeks, < 35 weeks and < 37 weeks of gestation were 14.7% (29/197), 21.3% (46/216), 28.7% (62/216) and 42.1% (91/216), respectively. Patients with 'sludge' had: (1) a higher rate of spontaneous preterm delivery at < 28 weeks (46.5% (20/43) vs. 5.8% (9/154); P < 0.001), < 32 weeks (55.6% (25/45) vs. 12.3% (21/171); P < 0.001) and < 35 weeks (62.2% (28/45) vs. 19.9% (34/171); P < 0.001); (2) a higher frequency of clinical chorioamnionitis (15.2% (10/66) vs. 5.1% (11/215); P = 0.007), histologic chorioamnionitis (61.5% (40/65) vs. 28% (54/193); P < 0.001) and funisitis (32.3% (21/65) vs. 19.2% (37/193); P = 0.03); (3) a higher frequency of preterm prelabor rupture of membranes (PROM) (39.4% (26/66) vs. 13.5% (29/215); P < 0.001), lower gestational age at preterm PROM (median 24.7 (interquartile range (IQR), 22.3-28.1) weeks vs. 32.3 (IQR, 27.7-34.8) weeks; P < 0.001); and (4) shorter median ultrasound-to-delivery interval ('sludge' positive 127 days (95% CI, 120-134 days) vs. 'sludge' negative 161 days (95% CI, 153-169 days); P < 0.001) and ultrasound-to-preterm PROM interval ('sludge' positive 23 days (95% CI, 7-39 days) vs. 'sludge' negative 57 days (95% CI, 38-77 days); P = 0.003) than those without 'sludge'. AF 'sludge' was an independent explanatory variable for the occurrence of spontaneous preterm delivery at < 28 weeks, < 32 weeks and < 35 weeks, preterm PROM, microbial invasion of the amniotic cavity (MIAC) and histologic chorioamnionitis. Moreover, the combination of a cervical length < 25 mm and 'sludge' conferred an odds ratio of 14.8 and 9.9 for spontaneous preterm delivery at < 28 weeks and < 32 weeks, respectively. CONCLUSIONS: AF 'sludge' is an independent risk factor for spontaneous preterm delivery, preterm PROM, MIAC and histologic chorioamnionitis in asymptomatic patients at high risk for spontaneous preterm delivery. Furthermore, the combination of 'sludge' and a short cervix confers a higher risk for spontaneous preterm delivery at < 28 weeks and < 32 weeks than a short cervix alone.


Subject(s)
Amniotic Fluid/diagnostic imaging , Obstetric Labor, Premature/etiology , Pregnancy Complications, Infectious/diagnostic imaging , Adult , Amniotic Fluid/microbiology , Case-Control Studies , Cervix Uteri/abnormalities , Female , Gestational Age , Humans , Pregnancy , Pregnancy Complications, Infectious/prevention & control , Retrospective Studies , Risk Factors , Ultrasonography
2.
Ultrasound Obstet Gynecol ; 24(7): 787-92, 2004 Dec.
Article in English | MEDLINE | ID: mdl-15543526

ABSTRACT

Congenital aneurysm of the membranous portion of the ventricular septum in association with absence of atrioventricular valve 'offsetting' was diagnosed in two fetuses at 29 and 34 weeks. In the first case the fetus had a normal karyotype and no other structural heart defects, whereas in the second case there was a partial deletion of the long arm of chromosome 5 and an absent pulmonary valve syndrome. The association of absence of 'offsetting' with aneurysms of the membranous ventricular septum may represent spontaneous closure of ventricular septal defects initially extended to the inlet.


Subject(s)
Heart Septal Defects/diagnostic imaging , Heart Valve Diseases/diagnostic imaging , Ultrasonography, Prenatal , Adolescent , Adult , Echocardiography, Doppler, Color , Female , Humans , Pregnancy
3.
Ultrasound Obstet Gynecol ; 21(2): 111-8, 2003 Feb.
Article in English | MEDLINE | ID: mdl-12601829

ABSTRACT

OBJECTIVES: This study was designed to compare a conventional multiplanar technique for three-dimensional (3D) ultrasound measurement of fetal lung volume with a rotational method using VOCAL trade mark (Virtual Organ Computer-aided AnaLysis). METHODS: Thirty-two fetuses with a variety of conditions at risk for pulmonary hypoplasia were studied. 3D volume data sets of the fetal lungs were acquired using a commercially available ultrasound system. The right and left lung volumes were calculated separately using VOCAL and the multiplanar technique. The level of agreement between two independent observers in categorizing the 3D volume data set as measurable or non-measurable was determined. The interobserver and intermethod variabilities were also evaluated for both methods. RESULTS: The intermethod variability was excellent (correlation r = 0.93 and r = 0.96 for the left and right lung, respectively), and there was substantial agreement between the results of both approaches (limits of agreement - 4.4 to 8.9 and - 3.4 to 4.8 mL for the right and left lung, respectively). Fetal lung estimation with VOCAL had a significantly higher interobserver variability than the multiplanar technique. Interobserver agreement in categorizing lung volume data sets as measurable or non-measurable was lower when VOCAL was used. CONCLUSION: Fetal lung volume measurements can be undertaken interchangeably using the multiplanar technique or the rotational method with VOCAL. However, the latter was less reproducible (lower degree of agreement and significantly higher interobserver variability) than the former.


Subject(s)
Lung/embryology , Ultrasonography, Prenatal/methods , Female , Gestational Age , Humans , Imaging, Three-Dimensional/methods , Lung/abnormalities , Lung/diagnostic imaging , Lung Volume Measurements/methods , Observer Variation , Pregnancy , Regression Analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...