Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Struct Biol ; 192(2): 146-50, 2015 Nov.
Article in English | MEDLINE | ID: mdl-25882513

ABSTRACT

The MRC binary file format is widely used in the three-dimensional electron microscopy field for storing image and volume data. Files contain a header which describes the kind of data held, together with other important metadata. In response to advances in electron microscopy techniques, a number of variants to the file format have emerged which contain useful additional data, but which limit interoperability between different software packages. Following extensive discussions, the authors, who represent leading software packages in the field, propose a set of extensions to the MRC format standard designed to accommodate these variants, while restoring interoperability. The MRC format is equivalent to the map format used in the CCP4 suite for macromolecular crystallography, and the proposal also maintains interoperability with crystallography software. This Technical Note describes the proposed extensions, and serves as a reference for the standard.


Subject(s)
Cryoelectron Microscopy/methods , Electron Microscope Tomography/methods , Information Storage and Retrieval/methods , Imaging, Three-Dimensional/methods , Software
2.
Ultramicroscopy ; 111(8): 1029-36, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21740865

ABSTRACT

Today, the resolution in phase-contrast cryo-electron tomography is for a significant part limited by the contrast transfer function (CTF) of the microscope. The CTF is a function of defocus and thus varies spatially as a result of the tilting of the specimen and the finite specimen thickness. Models that include spatial dependencies have not been adopted in daily practice because of their high computational complexity. Here we present an algorithm which reduces the processing time for computing the 'tilted' CTF by more than a factor 100. Our implementation of the full 3D CTF has a processing time on the order of a Radon transform of a full tilt-series. We derive and validate an expression for the damping envelope function describing the loss of resolution due to specimen thickness. Using simulations we quantify the effects of specimen thickness on the accuracy of various forward models. We study the influence of spatially varying CTF correction and subsequent tomographic reconstruction by simulation and present a new approach for space-variant phase-flipping. We show that our CTF correction strategies are successful in increasing the resolution after tomographic reconstruction.

SELECTION OF CITATIONS
SEARCH DETAIL
...