Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 17(2): e0262826, 2022.
Article in English | MEDLINE | ID: mdl-35113893

ABSTRACT

BACKGROUND: To identify magnetic resonance (MR) angiography derived predictors of progressive dilatation and surgery of the aortic root in Marfan syndrome. MATERIAL AND METHODS: We retrospectively included 111 patients (32.7±16.5 years, range: 7-75 years) with a total of 446 MR angiographies. Aortic diameter growth rates of the entire thoracic aorta and Z-scores were estimated from annual diameter measurements. Aortic root shape was subdivided into three different types: (T0) normal; (T1) localized dilatation; (T2) generalized aortic root dilatation. Aortic diameter, Z-score, age, and aortic root shape at baseline were tested as predictors of aortic root dilatation using a multivariate logistic regression model. RESULTS: The highest aortic growth rate was observed at the level of the sinuses of Valsalva. Higher aortic root diameters and Z-scores at baseline predicted an increased growth of the aortic root (p = 0.003 and p<0.001). Young age (<30 years) was a predictor for the increase of Z-scores when compared to patients ≥30 years (p = 0.019). 25/111 patients (22.5%) had a T0 aortic root shape, 59/111 patients (53.2%) had a T1 aortic root shape, and 27/111 patients (24.3%) had a T2 aortic root shape. Aortic root shape did not predict further aortic growth (p>0.05). However, significantly more patients undergoing surgery had a generalized aortic dilatation (19/28, 76.9%) than a localized aortic root dilatation (9/28, 32.1%) (p = 0.001). CONCLUSION: Larger baseline aortic root diameter and Z-score as well as young age predict solely progressive aortic root dilatation in Marfan patients. MR angiography derived type of aortic root shape does not predict aortic growth, but patients with generalized aortic root dilatation are referred more frequently for aortic surgery.


Subject(s)
Marfan Syndrome
2.
Int J Cardiovasc Imaging ; 36(8): 1533-1542, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32314122

ABSTRACT

Aortic diameter measurements play a crucial role for the indication of aortic root surgery in Marfan patients. However, for magnetic resonance angiography (MRA)-derived measurements, there is no consensus on whether the aortic wall should be included or excluded in the aortic diameter. The purpose of this retrospective study was to compare the reliability of non-contrast bright blood MRA aortic inner-to-inner and outer-to-outer edge measurements in patients with Marfan syndrome. Forty Marfan patients underwent ECG-gated balanced steady-state free-precession MRA of the aorta at 1.5 T. Two readers independently performed inner and outer measurements at different aortic levels. They rated the image quality of the delineation of both inner and outer vessel wall edges on a four-point scale. MRA-derived diameters of the sinuses of Valsalva were compared with echocardiography-derived diameters. Aortic vessel wall delineation score was rated higher at all levels for inner than for outer vessel walls (p < 0.001). Inter- and intraobserver variances of aortic measurements were smaller for inner-to-inner measurements at the sinuses of Valsalva, sinotubular junction and ascending aorta (p < 0.03). There was a difference of 1.1 ± 2.3 mm for inner MRA measurements (p = 0.014) and 6.9 ± 3.1 mm for outer MRA measurements (p < 0.001) when compared to echocardiographic leading-edge measurements. Inner-to-inner vessel wall diameter measurements in non-contrast bright blood MRA provide more reliable diameters when compared to outer-to-outer vessel wall measurements of the aortic root. Therefore, we propose to rely on inner rather than outer aortic wall measurements in non-contrast-MRA when monitoring aortic diameters in patients with Marfan syndrome.


Subject(s)
Aorta/diagnostic imaging , Aortic Aneurysm/diagnostic imaging , Magnetic Resonance Angiography , Marfan Syndrome/complications , Sinus of Valsalva/diagnostic imaging , Adolescent , Adult , Aorta/physiopathology , Aortic Aneurysm/etiology , Aortic Aneurysm/physiopathology , Cardiac-Gated Imaging Techniques , Dilatation, Pathologic , Electrocardiography , Female , Humans , Male , Marfan Syndrome/diagnosis , Middle Aged , Observer Variation , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies , Sinus of Valsalva/physiopathology , Vascular Remodeling , Young Adult
3.
Magn Reson Med Sci ; 16(2): 98-108, 2017 Apr 10.
Article in English | MEDLINE | ID: mdl-27001390

ABSTRACT

PURPOSE: Electrocardiogram (ECG) triggering for cardiac magnetic resonance (CMR) may be influenced by electromagnetic interferences with increasing magnetic field strength. The aim of this study was to evaluate the performance of Doppler ultrasound (DUS) as an alternative trigger technique for CMR in comparison to ECG and pulse oximetry (POX) at 3T and using different sequence types. METHODS: Balanced turbo field echo two-dimensional (2D) short axis cine CMR and 2D phase-contrast angiography of the ascending aorta was performed in 11 healthy volunteers at 3T using ECG, DUS, and POX for cardiac triggering. DUS and POX triggering were compared to the reference standard of ECG in terms of trigger quality (trigger detection and temporal variability), image quality [endocardial blurring (EB)], and functional measurements [left ventricular (LV) volumetry and aortic blood flow velocimetry]. RESULTS: Trigger signal detection and temporal variability did not differ significantly between ECG/DUS (I = 0.6) and ECG/POX (P = 0.4). Averaged EB was similar for ECG, DUS, and POX (pECG/DUS = 0.4, pECG/POX = 0.9). Diastolic EB was significantly decreased for DUS in comparison to ECG (P = 0.02) and POX (P = 0.04). The LV function assessment and aortic blood flow were not significantly different. CONCLUSION: This study demonstrated the feasibility of DUS for gating human CMR at 3T. The magnetohydrodynamic effect did not significantly disturb ECG triggering in this small healthy volunteer study. DUS showed a significant improvement in diastolic EB but could not be identified as a superior trigger method. The potential benefit of DUS has to be evaluated in a larger clinical patient population.


Subject(s)
Aorta/anatomy & histology , Aorta/diagnostic imaging , Magnetic Resonance Imaging/methods , Ultrasonography, Doppler/methods , Adult , Electrocardiography/methods , Feasibility Studies , Humans , Male , Oximetry , Reference Values , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...