Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Physiol Meas ; 32(5): 571-83, 2011 May.
Article in English | MEDLINE | ID: mdl-21454925

ABSTRACT

The forced oscillation technique (FOT) allows the measurement of respiratory mechanics in the intensive care setting. The aim of this study was to compare the FOT with a reference method during mechanical ventilation through a tracheal tube. The respiratory impedance spectra were measured by FOT in nine anaesthetized pigs, and resistance and compliance were estimated on the basis of a linear resistance-compliance inertance model. In comparison, resistance and compliance were quantified by the multiple linear regression analysis (LSF) of conventional ventilator waveforms to the equation of motion. The resistance of the sample was found to range from 6 to 21 cmH(2)O s l(-1) and the compliance from 12 to 32 ml cmH(2)O(-1). A Bland-Altman analysis of the resistance resulted in a sufficient agreement (bias -0.4 cmH(2)O s l(-1); standard deviation of differences 1.4 cmH(2)O s l(-1); correlation coefficient 0.93) and test-retest reliability (coefficient of variation of repeated measurements: FOT 2.1%; LSF 1.9%). The compliance, however, was poor in agreement (bias -8 ml cmH(2)O(-1), standard deviation of differences 7 ml cmH(2)O(-1), correlation coefficient 0.74) and repeatability (coefficient of variation: FOT 23%; LSF 1.7%). In conclusion, FOT provides an alternative for monitoring resistance, but not compliance, in tracheally intubated and ventilated subjects.


Subject(s)
Respiration, Artificial/methods , Respiratory Mechanics , Trachea , Animals , Lung Compliance/physiology , Reference Standards , Reproducibility of Results , Respiration, Artificial/instrumentation , Respiration, Artificial/standards , Swine , Time Factors
2.
Anesth Analg ; 110(6): 1661-8, 2010 Jun 01.
Article in English | MEDLINE | ID: mdl-20448078

ABSTRACT

BACKGROUND: Functional magnetic resonance imaging (fMRI) of fluorine-19 allows for the mapping of oxygen partial pressure within perfluorocarbons in the alveolar space (Pao(2)). Theoretically, fMRI-detected Pao(2) can be combined with the Fick principle approach, i.e., a mass balance of oxygen uptake by ventilation and delivery by perfusion, to quantify the ventilation-perfusion ratio (Va/Q) of a lung region: The mixed venous blood and the inspiratory oxygen fraction, which are equal for all lung regions, are measured. In addition, the local expiratory oxygen fraction and the end capillary oxygen content, both of which may differ between the lung regions, are calculated using the fMRI-detected Pao(2). We investigated this approach by numerical simulations and applied it to quantify local Va/Q in the perfluorocarbons during partial liquid ventilation. METHODS: Numerical simulations were performed to analyze the sensitivity of the Va/Q calculation and to compare this approach with another one proposed by Rizi et al. in 2004 (Magn Reson Med 2004;52:65-72). Experimentally, the method was used during partial liquid ventilation in 7 anesthetized pigs. The Pao(2) distribution in intraalveolar perflubron was measured by fluorine-19 MRI. Respiratory gas fractions together with arterial and mixed venous blood samples were taken to quantify oxygen partial pressure and content. Using the Fick principle, the local Va/Q was estimated. The impact of gravity (nondependent versus dependent) of perflubron dose (10 vs 20 mL/kg body weight) and of inspired oxygen fraction (Fio(2)) (0.4-1.0) on Va/Q was examined. RESULTS: In numerical simulations, the Fick principle proved to be appropriate over the Va/Q range from 0.02 to 2.5. Va/Q values were in acceptable agreement with the method published by Rizi et al. In the experimental setting, low mean Va/Q values were found in perflubron (confidence interval [CI] 0.08-0.29 with 20 mL/kg perflubron). At this dose, Va/Q in the nondependent lung was higher (CI 0.18-0.39) than in the dependent lung regions (CI 0.06-0.16; P = 0.006; Student t test). Differences depending on Fio(2) or perflubron dose were, however, small. CONCLUSION: The results show that derivation of Va/Q from local Po(2) measurements using fMRI in perflubron is feasible. The low detected Va/Q suggests that oxygen transport into the perflubron-filled alveolar space is significantly restrained.


Subject(s)
Contrast Media , Fluorocarbons , Liquid Ventilation , Magnetic Resonance Imaging/methods , Pulmonary Alveoli/physiology , Ventilation-Perfusion Ratio/physiology , Algorithms , Animals , Blood Gas Monitoring, Transcutaneous , Body Temperature , Computer Simulation , Fluorine Radioisotopes , Hemodynamics/physiology , Humans , Hydrocarbons, Brominated , Oxygen/blood , Pulmonary Alveoli/metabolism , Pulmonary Diffusing Capacity , Swine
3.
Magn Reson Imaging ; 27(4): 549-56, 2009 May.
Article in English | MEDLINE | ID: mdl-18930366

ABSTRACT

Magnetic resonance imaging of inhaled fluorinated inert gases ((19)F-MRI) such as sulfur hexafluoride (SF(6)) allows for analysis of ventilated air spaces. In this study, the possibility of using this technique to image lung function was assessed. For this, (19)F-MRI of inhaled SF(6) was compared with respiratory gas analysis, which is a global but reliable measure of alveolar gas fraction. Five anesthetized pigs underwent multiple-breath wash-in procedures with a gas mixture of 70% SF(6) and 30% oxygen. Two-dimensional (19)F-MRI and end-expiratory gas fraction analysis were performed after 4 to 24 inhaled breaths. Signal intensity of (19)F-MRI and end-expiratory SF(6) fraction were evaluated with respect to linear correlation and reproducibility. Time constants were estimated by both MRI and respiratory gas analysis data and compared for agreement. A good linear correlation between signal intensity and end-expiratory gas fraction was found (correlation coefficient 0.99+/-0.01). The data were reproducible (standard error of signal intensity 8% vs. that of gas fraction 5%) and the comparison of time constants yielded a sufficient agreement. According to the good linear correlation and the acceptable reproducibility, we suggest the (19)F-MRI to be a valuable tool for quantification of intrapulmonary SF(6) and hence lung function.


Subject(s)
Breath Tests/methods , Image Enhancement/methods , Lung/physiology , Magnetic Resonance Imaging/methods , Pulmonary Gas Exchange/physiology , Sulfur Hexafluoride/pharmacokinetics , Administration, Inhalation , Animals , Reproducibility of Results , Sensitivity and Specificity , Spirometry/methods , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...