Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
NPJ Parkinsons Dis ; 10(1): 61, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38491070

ABSTRACT

The synthetic tetrahydrocannabinol-analog nabilone improved non-motor symptoms (NMS) in Parkinson's disease (PD) patients in a placebo-controlled, double-blind, parallel-group, randomized withdrawal trial with enriched enrollment (NMS-Nab-study). This was a single-center open-label extension study to assess the long-term safety and efficacy of nabilone for NMS in PD. To be eligible for this study, patients had to be treatment responders during the previous NMS-Nab-trial and complete its double-blind phase without experiencing a drug-related serious/severe/moderate adverse event (AE). Patients were re-introduced to nabilone during an up-titration phase until their overall NMS burden improved. Nabilone was continued for six months with clinic visits every 3 months. Evaluation of AEs was based on self-report and clinical assessment. Twenty-two patients participated in the NMS-Nab2-study (age-median 68.33 y, 52% females, disease duration-median 7.42 y). Nabilone was well tolerated with concentration difficulties as the most common treatment-related AE (possibly/not related n = 1 each). One in two drop-outs discontinued because of an AE for which a prohibited concomitant medication needed to be introduced (night-time sleep problems). Efficacy evaluation showed a significant and lasting improvement in NMS burden according to the CGI-I (79% at V3). Nabilone improved overall sleep (NMSS Domain-2: -8.26 points; 95%CI -13.82 to -2.71; p = 0.004; ES = -0.72), night-time sleep problems (MDS-UPDRS-1.7: -1.42 points; 95 CI -2.16 to -0.68; p = 0.002; ES = -0.92), and overall pain (KPPS Total Score: -8.00 points; 95%CI -15.05 to -0.95; p = 0.046; ES -0.55 and MDS-UPDRS-1.9: -0.74 points; 95%CI -1.21 to -0.26; p = 0.008; ES = -0.74). This study demonstrates continuous long-term safety and efficacy in PD patients responding early to nabilone without intolerable side effects.

2.
Gerontology ; 68(10): 1139-1144, 2022.
Article in English | MEDLINE | ID: mdl-34963115

ABSTRACT

BACKGROUND: Recurrent falls represent a major source of serious adverse health outcomes in the general older population. Gait impairment has been linked to recurrent falls, but there are only limited long-term data on this association. OBJECTIVES: The objective of the study was to investigate the association of gait disorders (GDs) and gait tests with future falls in an existing longitudinal population-based cohort. METHOD: The study was performed in participants of the Bruneck Study cohort 2010 aged 60-97 years, with prospective 5-year follow-up. At baseline, participants underwent a clinical gait assessment (to determine neurological and non-neurological GDs according to an established classification) and were also evaluated by quantitative and semiquantitative gait tests (Hauser Index, Tinetti balance and gait test, and gait speed). Logistic regression analysis adjusted for age and sex was used to determine the relationship of baseline variables with incident recurrent falls at 5-year follow-up. RESULTS: Of 328 included participants, 22 (6.7%) reported recurrent falls at follow-up. Baseline presence of GDs was associated with recurrent falls at follow-up (odds ratio [OR] 4.2; 95% confidence interval [CI] 1.6-11.1; p = 0.004), and this effect was largely driven by neurological GDs (OR 5.5; 95% CI 1.7-17.4; p = 0.004). All 3 simple gait tests were predictive for incident falls (Hauser Index, p = 0.002; Tinetti test, p = 0.006; and gait speed, p < 0.001). CONCLUSIONS: Clinical assessment of GDs and gait tests both had independent significant predictive value for recurrent falls over a 5-year follow-up period. This highlights the potential of such assessments for early fall risk screening and timely implementation of fall-preventive measures.


Subject(s)
Accidental Falls , Movement Disorders , Accidental Falls/prevention & control , Aged , Gait , Humans , Prospective Studies , Walking Speed
3.
J Neurol ; 268(5): 1770-1779, 2021 May.
Article in English | MEDLINE | ID: mdl-33382439

ABSTRACT

BACKGROUND: Gait impairment is a pivotal feature of parkinsonian syndromes and increased gait variability is associated with postural instability and a higher risk of falls. OBJECTIVES: We compared gait variability at different walking velocities between and within groups of patients with Parkinson-variant multiple system atrophy, idiopathic Parkinson's disease, and a control group of older adults. METHODS: Gait metrics were recorded in 11 multiple system atrophy, 12 Parkinson's disease patients, and 18 controls using sensor-based gait analysis. Gait variability was analyzed for stride, swing and stance time, stride length and gait velocity. Values were compared between and within the groups at self-paced comfortable, fast and slow walking speed. RESULTS: Multiple system atrophy patients displayed higher gait variability except for stride time at all velocities compared with controls, while Parkinson's patients did not. Compared with Parkinson's disease, multiple system atrophy patients displayed higher variability of swing time, stride length and gait velocity at comfortable speed and at slow speed for swing and stance time, stride length and gait velocity (all P < 0.05). Stride time variability was significantly higher in slow compared to comfortable walking in patients with multiple system atrophy (P = 0.014). Variability parameters significantly correlated with the postural instability/gait difficulty subscore in both disease groups. Conversely, significant correlations between variability parameters and MDS-UPDRS III score was observed only for multiple system atrophy patients. CONCLUSION: This analysis suggests that gait variability parameters reflect the major axial impairment and postural instability displayed by multiple system atrophy patients compared with Parkinson's disease patients and controls.


Subject(s)
Gait Disorders, Neurologic , Multiple System Atrophy , Parkinson Disease , Aged , Gait , Gait Disorders, Neurologic/diagnosis , Gait Disorders, Neurologic/etiology , Humans , Multiple System Atrophy/complications , Parkinson Disease/complications , Walking
4.
Int J Radiat Oncol Biol Phys ; 70(3): 944-52, 2008 Mar 01.
Article in English | MEDLINE | ID: mdl-18164834

ABSTRACT

PURPOSE: The aim of this study is to implement augmented reality in real-time image-guided interstitial brachytherapy to allow an intuitive real-time intraoperative orientation. METHODS AND MATERIALS: The developed system consists of a common video projector, two high-resolution charge coupled device cameras, and an off-the-shelf notebook. The projector was used as a scanning device by projecting coded-light patterns to register the patient and superimpose the operating field with planning data and additional information in arbitrary colors. Subsequent movements of the nonfixed patient were detected by means of stereoscopically tracking passive markers attached to the patient. RESULTS: In a first clinical study, we evaluated the whole process chain from image acquisition to data projection and determined overall accuracy with 10 patients undergoing implantation. The described method enabled the surgeon to visualize planning data on top of any preoperatively segmented and triangulated surface (skin) with direct line of sight during the operation. Furthermore, the tracking system allowed dynamic adjustment of the data to the patient's current position and therefore eliminated the need for rigid fixation. Because of soft-part displacement, we obtained an average deviation of 1.1 mm by moving the patient, whereas changing the projector's position resulted in an average deviation of 0.9 mm. Mean deviation of all needles of an implant was 1.4 mm (range, 0.3-2.7 mm). CONCLUSIONS: The developed low-cost augmented-reality system proved to be accurate and feasible in interstitial brachytherapy. The system meets clinical demands and enables intuitive real-time intraoperative orientation and monitoring of needle implantation.


Subject(s)
Brachytherapy/instrumentation , Imaging, Three-Dimensional/instrumentation , Neoplasms/radiotherapy , Radiotherapy, Computer-Assisted/instrumentation , Brachytherapy/methods , Data Display , Equipment Design , Humans , Imaging, Three-Dimensional/methods , Intraoperative Period , Radiotherapy, Computer-Assisted/methods , Tomography, X-Ray Computed , User-Computer Interface
SELECTION OF CITATIONS
SEARCH DETAIL
...