Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Accid Anal Prev ; 30(6): 851-61, 1998 Nov.
Article in English | MEDLINE | ID: mdl-9805528

ABSTRACT

Statistical models were developed to help understand the relationship between the driver age and several important accident-related factors and circumstances such as injury severity, collision types, average daily traffic (ADT), roadway character, speed ratio, alcohol involvement, and accident location. By using techniques of categorical analysis on the 1994 and 1995 Florida accident database, four long-linear models with three variables in each model with all possible two-way interactions were developed. In order to compare the differences in response between the age groups and a particular accident-related variable, odds multipliers were computed. The effects of age and accident-related factors were examined, and interactions among them were considered. The results indicated significant relationships between the driver age and ADT, injury severity, manner of collision, speed, alcohol involvement, and roadway character. The findings' contribution to the understanding of the effect of age on accident involvement is addressed. A discussion of how log-linear and logit modeling with estimation of 'odds multipliers' may contribute to traffic safety studies is also provided.


Subject(s)
Accidents, Traffic/statistics & numerical data , Adolescent , Adult , Age Factors , Aged , Aged, 80 and over , Alcoholic Intoxication/epidemiology , Female , Florida/epidemiology , Humans , Linear Models , Male , Middle Aged , Odds Ratio , Risk
2.
Appl Opt ; 32(7): 1234-42, 1993 Mar 01.
Article in English | MEDLINE | ID: mdl-20820258

ABSTRACT

Currently, spectrophotometric standard reference materials are calibrated only by using the illumination and viewing geometries recommended by the Commission Internationale de l'Eclairage, and for some geometries the spectral range is limited to the visible wavelengths. A need exists for procedures that calibrate standards at many other geometries and for a broader spectral range. Two methods for calibrating the spectral bidirectional reflectance factor are described. The absolute bidirectional reflectance factor of a sintered polytetrafluoroethylene (PTFE) sample is determined for nearly all the possible illumination and viewing geometries from 400 nm to 2500 nm. The references are a 45/0 reflectance standard calibrated by the National Institute of Standards and Technology and a sintered PTFE sample with a directional, hemispherical reflectance factor traceable to the Institute. The results of the two methods agree to within 0.01 in reflectance factor values. With this PTFE sample as a transfer standard, the instrument described can also be used to measure the absolute bidirectional reflectance factor at nearly all the illumination and viewing geometries from 400 nm to 2500 nm.

SELECTION OF CITATIONS
SEARCH DETAIL
...