Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Chromatogr ; 35(12): e5224, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34363425

ABSTRACT

A liquid chromatography-tandem mass spectrometry method was developed and validated to quantify alectinib, crizotinib, erlotinib and gefitinib. This assay can be combined with our method for osimertinib, allowing quantification of the most used ALK- and EGFR-tyrosine kinase inhibitors (TKIs) in non-small cell lung cancer with a single-assay setup. Chromatographic separation was performed on a HyPurity® C18 analytical column using an elution gradient of ammonium acetate in water and in methanol, both acidified with formic acid 0.1%. Detection and quantification were performed using a triple quad mass spectrometer with an electrospray ionization interface. This method led to robust results, as the selectivity, carryover, precision and accuracy met all pre-specified requirements. The assay was validated over a linear range of 100-2,000 ng/ml for alectinib and erlotinib and 50-1,000 ng/ml for crizotinib and gefitinib. Alectinib, crizotinib, erlotinib and gefitinib were all stable for at least 4 h in whole blood (at room temperature and at 4°C) and for at least 1 month in EDTA plasma when stored at -80°C, while osimertinib proved to be unstable at room temperature. Although high-performance liquid chromatography was used, the run time was short and comparable with other methods using ultra-high performance liquid chromatography.


Subject(s)
Antineoplastic Agents/blood , Chromatography, High Pressure Liquid/methods , Protein Kinase Inhibitors/blood , Tandem Mass Spectrometry/methods , Humans , Limit of Detection , Linear Models , Reproducibility of Results
2.
Langmuir ; 24(1): 19-21, 2008 Jan 01.
Article in English | MEDLINE | ID: mdl-18044939

ABSTRACT

Membranes prepared by the adsorption of phospholipid vesicles on solid supports are much-used model systems in biomedical research. However, there is accumulating evidence that such membranes may not always be equivalent to the free-standing cellular membranes that they are modeling. In the present study, sonicated DOPC/DOPS (80/20 mol %) vesicles were adsorbed on hydrophilic silica surfaces, a system that has been demonstrated to produce confluent bilayers. In addition, pure DOPC and DLPC membranes were studied. It is demonstrated that ethanol-induced membrane interdigitation, as demonstrated for free-standing bilayers, does not occur in these supported membranes.


Subject(s)
Ethanol/chemistry , Lipid Bilayers/chemistry , Membranes, Artificial , Phospholipids/chemistry , Silicon Dioxide/chemistry , Adsorption , Surface Properties , Temperature , Time Factors