1.
Sensors (Basel) ; 24(6)2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38544153

ABSTRACT

Repeated single-point measurements of thoracic bioimpedance at a single (low) frequency are strongly related to fluid changes during hemodialysis. Extension to semi-continuous measurements may provide longitudinal details in the time pattern of the bioimpedance signal, and multi-frequency measurements may add in-depth information on the distribution between intra- and extracellular fluid. This study aimed to investigate the feasibility of semi-continuous multi-frequency thoracic bioimpedance measurements by a wearable device in hemodialysis patients. Therefore, thoracic bioimpedance was recorded semi-continuously (i.e., every ten minutes) at nine frequencies (8-160 kHz) in 68 patients during two consecutive hemodialysis sessions, complemented by a single-point measurement at home in-between both sessions. On average, the resistance signals increased during both hemodialysis sessions and decreased during the interdialytic interval. The increase during dialysis was larger at 8 kHz (∆ 32.6 Ω during session 1 and ∆ 10 Ω during session 2), compared to 160 kHz (∆ 29.5 Ω during session 1 and ∆ 5.1 Ω during session 2). Whereas the resistance at 8 kHz showed a linear time pattern, the evolution of the resistance at 160 kHz was significantly different (p < 0.0001). Measuring bioimpedance semi-continuously and with a multi-frequency current is a major step forward in the understanding of fluid dynamics in hemodialysis patients. This study paves the road towards remote fluid monitoring.


Subject(s)
Renal Dialysis , Wearable Electronic Devices , Humans , Feasibility Studies , Electric Impedance , Extracellular Fluid
2.
J Appl Physiol (1985) ; 135(6): 1330-1338, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37767559

ABSTRACT

In contrast to whole body bioimpedance, which estimates fluid status at a single point in time, thoracic bioimpedance applied by a wearable device could enable continuous measurements. However, clinical experience with thoracic bioimpedance in patients on dialysis is limited. To test the reproducibility of whole body and thoracic bioimpedance measurements and to compare their relationship with hemodynamic changes during hemodialysis, these parameters were measured pre- and end-dialysis in 54 patients during two sessions. The resistance from both bioimpedance techniques was moderately reproducible between two dialysis sessions (intraclass correlations of pre- to end-dialysis whole body and thoracic resistance between session 1 and 2 were 0.711 [0.58-0.8] and 0.723 [0.6-0.81], respectively). There was a very high to high correlation between changes in ultrafiltration volume and changes in whole body thoracic resistance. Changes in systolic blood pressure negatively correlated to both bioimpedance techniques. Although the relationship between changes in ultrafiltration volume and changes in resistance was stronger for whole body bioimpedance, the relationship with changes in blood pressure was at least comparable for thoracic measurements. These results suggest that thoracic bioimpedance, measured by a wearable device, may serve as an interesting alternative to whole body measurements for continuous hemodynamic monitoring during hemodialysis.NEW & NOTEWORTHY We examined the role of whole body and thoracic bioimpedance in hemodynamic changes during hemodialysis. Whole body and thoracic bioimpedance signals were strongly related to ultrafiltration volume and moderately, negatively, to changes in blood pressure. This work supports the further development of a wearable device measuring thoracic bioimpedance longitudinally in patients on hemodialysis. As such, it may serve as an innovative tool for continuous hemodynamic monitoring during hemodialysis in hospital or in a home-based setting.


Subject(s)
Renal Dialysis , Ultrafiltration , Humans , Ultrafiltration/methods , Blood Pressure , Reproducibility of Results , Electric Impedance
5.
J Am Soc Nephrol ; 32(12): 3208-3220, 2021 12 01.
Article in English | MEDLINE | ID: mdl-34588184

ABSTRACT

BACKGROUND: Preliminary evidence suggests patients on hemodialysis have a blunted early serological response to SARS-CoV-2 vaccination. Optimizing the vaccination strategy in this population requires a thorough understanding of predictors and dynamics of humoral and cellular immune responses to different SARS-CoV-2 vaccines. METHODS: This prospective multicenter study of 543 patients on hemodialysis and 75 healthy volunteers evaluated the immune responses at 4 or 5 weeks and 8 or 9 weeks after administration of the BNT162b2 or mRNA-1273 vaccine, respectively. We assessed anti-SARS-CoV-2 spike antibodies and T cell responses by IFN-γ secretion of peripheral blood lymphocytes upon SARS-CoV-2 glycoprotein stimulation (QuantiFERON assay) and evaluated potential predictors of the responses. RESULTS: Compared with healthy volunteers, patients on hemodialysis had an incomplete, delayed humoral immune response and a blunted cellular immune response. Geometric mean antibody titers at both time points were significantly greater in patients vaccinated with mRNA-1273 versus BNT162b2, and a larger proportion of them achieved the threshold of 4160 AU/ml, corresponding with high neutralizing antibody titers in vitro (53.6% versus 31.8% at 8 or 9 weeks, P <0.0001). Patients vaccinated with mRNA-1273 versus BNT162b2 exhibited significantly greater median QuantiFERON responses at both time points, and a larger proportion achieved the threshold of 0.15 IU/ml (64.4% versus 46.9% at 8 or 9 weeks, P <0.0001). Multivariate analysis identified COVID-19 experience, vaccine type, use of immunosuppressive drugs, serum albumin, lymphocyte count, hepatitis B vaccine nonresponder status, and dialysis vintage as independent predictors of the humoral and cellular responses. CONCLUSIONS: The mRNA-1273 vaccine's greater immunogenicity may be related to its higher mRNA dose. This suggests a high-dose vaccine might improve the impaired immune response to SARS-CoV-2 vaccination in patients on hemodialysis.


Subject(s)
COVID-19 Vaccines , COVID-19 , Humans , BNT162 Vaccine , 2019-nCoV Vaccine mRNA-1273 , Prospective Studies , COVID-19/prevention & control , SARS-CoV-2 , Antibodies, Viral , Immunity, Cellular
6.
J Clin Med ; 9(10)2020 Sep 29.
Article in English | MEDLINE | ID: mdl-33003544

ABSTRACT

Cardiac rehabilitation (CR) is a highly recommended secondary prevention measure for patients with diagnosed cardiovascular disease. Unfortunately, participation rates are low due to enrollment and adherence issues. As such, new CR delivery strategies are of interest, as to improve overall CR delivery. The goal of the study was to obtain a better understanding of the short-term progression of functional capacity throughout multidisciplinary CR, measured as the change in walking distance between baseline six-minute walking test (6MWT) and four consecutive follow-up tests. One-hundred-and-twenty-nine patients diagnosed with cardiovascular disease participated in the study, of which 89 patients who completed the whole study protocol were included in the statistical analysis. A one-way repeated measures ANOVA was conducted to determine whether there was a significant change in mean 6MWT distance (6MWD) throughout CR. A three-way-mixed ANOVA was performed to determine the influence of categorical variables on the progression in 6MWD between groups. Significant differences in mean 6MWD between consecutive measurements were observed. Two subgroups were identified based on the change in distance between baseline and end-of-study. Patients who increased most showed a linear progression. In the other group progression leveled off halfway through rehabilitation. Moreover, the improvement during the initial phase of CR seemed to be indicative for overall progression. The current study adds to the understanding of the short-term progression in exercise capacity of patients diagnosed with cardiovascular disease throughout a CR program. The results are not only of interest for CR in general, but could be particularly relevant in the setting of home-based CR.

7.
BMC Nephrol ; 21(1): 264, 2020 07 11.
Article in English | MEDLINE | ID: mdl-32652949

ABSTRACT

BACKGROUND: Haemodialysis (HD) patients are burdened by frequent fluid shifts which amplify their comorbidities. Bioimpedance (bioZ) is a promising technique to monitor changes in fluid status. The aim of this study is to investigate if the thoracic bioZ signal can track fluid changes during a HD session. METHODS: Prevalent patients from a single centre HD unit were monitored during one to six consecutive HD sessions using a wearable multi-frequency thoracic bioZ device. Ultrafiltration volume (UFV) was determined based on the interdialytic weight gain and target dry weight set by clinicians. The correlation between the bioZ signal and UFV was analysed on population level. Additionally regression models were built and validated per dialysis session. RESULTS: 66 patients were included, resulting in a total of 133 HD sessions. Spearman correlation between the thoracic bioZ and UFV showed a significant strong correlation of 0.755 (p < 0.01) on population level. Regression analysis per session revealed a strong relation between the bioZ value and the UFV (R2 = 0.982). The fluid extraction prediction error of the leave-one-out cross validation was very small (56.2 ml [- 121.1-194.1 ml]) across all sessions at all frequencies. CONCLUSIONS: This study demonstrated that thoracic bioZ is strongly correlated with fluid shifts during HD over a large range of UFVs. Furthermore, leave-one-out cross validation is a step towards personalized fluid monitoring during HD and could contribute to the creation of autonomous dialysis.


Subject(s)
Body Water , Electric Impedance , Extracellular Fluid , Intracellular Fluid , Kidney Failure, Chronic/therapy , Renal Dialysis/methods , Aged , Aged, 80 and over , Cohort Studies , Female , Humans , Male , Middle Aged , Prospective Studies
8.
Sensors (Basel) ; 20(12)2020 Jun 26.
Article in English | MEDLINE | ID: mdl-32604829

ABSTRACT

Cardiovascular diseases (CVD) are often characterized by their multifactorial complexity. This makes remote monitoring and ambulatory cardiac rehabilitation (CR) therapy challenging. Current wearable multimodal devices enable remote monitoring. Machine learning (ML) and artificial intelligence (AI) can help in tackling multifaceted datasets. However, for clinical acceptance, easy interpretability of the AI models is crucial. The goal of the present study was to investigate whether a multi-parameter sensor could be used during a standardized activity test to interpret functional capacity in the longitudinal follow-up of CR patients. A total of 129 patients were followed for 3 months during CR using 6-min walking tests (6MWT) equipped with a wearable ECG and accelerometer device. Functional capacity was assessed based on 6MWT distance (6MWD). Linear and nonlinear interpretable models were explored to predict 6MWD. The t-distributed stochastic neighboring embedding (t-SNE) technique was exploited to embed and visualize high dimensional data. The performance of support vector machine (SVM) models, combining different features and using different kernel types, to predict functional capacity was evaluated. The SVM model, using chronotropic response and effort as input features, showed a mean absolute error of 42.8 m (±36.8 m). The 3D-maps derived using the t-SNE technique visualized the relationship between sensor-derived biomarkers and functional capacity, which enables tracking of the evolution of patients throughout the CR program. The current study showed that wearable monitoring combined with interpretable ML can objectively track clinical progression in a CR population. These results pave the road towards ambulatory CR.


Subject(s)
Cardiac Rehabilitation , Monitoring, Ambulatory/instrumentation , Remote Sensing Technology , Support Vector Machine , Wearable Electronic Devices , Female , Humans , Male , Middle Aged
9.
J Med Internet Res ; 22(5): e17326, 2020 05 20.
Article in English | MEDLINE | ID: mdl-32432552

ABSTRACT

BACKGROUND: Cardiac rehabilitation (CR) is known for its beneficial effects on functional capacity and is a key component within current cardiovascular disease management strategies. In addition, a larger increase in functional capacity is accompanied by better clinical outcomes. However, not all patients respond in a similar way to CR. Therefore, a patient-tailored approach to CR could open up the possibility to achieve an optimal increase in functional capacity in every patient. Before treatment can be optimized, the differences in response of patients in terms of cardiac adaptation to exercise should first be understood. In addition, digital biomarkers to steer CR need to be identified. OBJECTIVE: The aim of the study was to investigate the difference in cardiac response between patients characterized by a clear improvement in functional capacity and patients showing only a minor improvement following CR therapy. METHODS: A total of 129 patients in CR performed a 6-minute walking test (6MWT) at baseline and during four consecutive short-term follow-up tests while being equipped with a wearable electrocardiogram (ECG) device. The 6MWTs were used to evaluate functional capacity. Patients were divided into high- and low-response groups, based on the improvement in functional capacity during the CR program. Commonly used heart rate parameters and cardiac digital biomarkers representative of the heart rate behavior during the 6MWT and their evolution over time were investigated. RESULTS: All participating patients improved in functional capacity throughout the CR program (P<.001). The heart rate parameters, which are commonly used in practice, evolved differently for both groups throughout CR. The peak heart rate (HRpeak) from patients in the high-response group increased significantly throughout CR, while no change was observed in the low-response group (F4,92=8.321, P<.001). Similar results were obtained for the recovery heart rate (HRrec) values, which increased significantly over time during every minute of recuperation, for the high-response group (HRrec1: P<.001, HRrec2: P<.001, HRrec3: P<.001, HRrec4: P<.001, and HRrec5: P=.02). The other digital biomarkers showed that the evolution of heart rate behavior during a standardized activity test differed throughout CR between both groups. These digital biomarkers, derived from the continuous measurements, contribute to more in-depth insight into the progression of patients' cardiac responses. CONCLUSIONS: This study showed that when using wearable sensor technology, the differences in response of patients to CR can be characterized by means of commonly used heart rate parameters and digital biomarkers that are representative of cardiac response to exercise. These digital biomarkers, derived by innovative analysis techniques, allow for more in-depth insights into the cardiac response of cardiac patients during standardized activity. These results open up the possibility to optimized and more patient-tailored treatment strategies and to potentially improve CR outcome.


Subject(s)
Biomarkers/chemistry , Biosensing Techniques/methods , Cardiac Rehabilitation/methods , Quality of Life/psychology , Female , Humans , Male , Middle Aged
10.
J Clin Med ; 9(2)2020 Feb 11.
Article in English | MEDLINE | ID: mdl-32054051

ABSTRACT

Intra-abdominal hypertension (IAH) causes severe organ dysfunction. Our aim is to evaluate the effect of increased intra-abdominal pressure (IAP) on renal function, hypothesizing that venous congestion may increase proteinuria and fluid retention without endothelial dysfunction. Three urine samples were collected from 32 non-pregnant women undergoing laparoscopic-assisted vaginal hysterectomy (LAVH) and from 10 controls placed in Trendelenburg position for 60 min. Urine sampling was done before (PRE), during or immediately after (PER), and two hours after (POST) the procedure. Urinary albumin, protein and creatinine concentrations were measured in each sample, and ratios were calculated and compared within and between groups. During LAVH, the albumin/creatinine ratio (ACR) increased and persisted POST-procedure, which was not observed in controls. A positive correlation existed between the LAVH duration and the relative change in both ACR and protein/creatinine ratio (PCR) PER- and POST-procedure. Iatrogenic IAH increases urinary ACR and PCR in non-pregnant women via a process of venous congestion. This mechanism might explain the presentation of one specific subtype of late-onset preeclampsia, where no drop of maternal cardiac output is observed.

11.
Br J Gen Pract ; 62(603): e718-25, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23265232

ABSTRACT

BACKGROUND: According to recent recommendations, healthcare professionals in palliative care should be able to perform a spiritual history-taking. Previous findings suggest that the FICA tool is feasible for the clinical assessment of spirituality. However, little is known about the views of GPs on the use of this tool. AIM: To provide a solid overview of the views of Flemish GPs concerning spirituality and the use of the FICA tool for spiritual history-taking in palliative care. DESIGN AND SETTING: Qualitative interview study in Flanders, Belgium. METHOD: Twenty-three GPs participated in a semi-structured interview. The interviews were analysed by thematic analysis, which includes line-by-line coding and the generation of descriptive and analytical themes. RESULTS: The interviewees stated that they would keep in mind the questions of the FICA tool while having a spiritual conversation, but not use them as a checklist. The content of the tool was generally appreciated as relevant, however, many GPs found the tool too structured and prescribed, and that it limited their spontaneity. They suggested rephrasing the questions into spoken language. The perceived barriers during spiritual conversations included feelings of discomfort and fear, and the lack of time and specific training. Factors that facilitated spiritual conversations included the patients' acceptance of their diagnosis, a trusting relationship, and respect for the patients' beliefs. CONCLUSION: A palliative care process with attention focused on the patient's spirituality was generally perceived as a tough but rewarding experience. The study concludes that the FICA tool could be a feasible instrument for the clinical assessment of spirituality, provided that certain substantive and linguistic adjustments are made. Additional research is needed to find the most suitable model for spiritual history-taking, in response to the specific needs of GPs.


Subject(s)
Attitude of Health Personnel , General Practitioners/psychology , Palliative Care/psychology , Spirituality , Surveys and Questionnaires , Adult , Belgium , Female , Humans , Male , Middle Aged , Physician's Role , Physician-Patient Relations , Qualitative Research
SELECTION OF CITATIONS
SEARCH DETAIL
...