Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 54
Filter
Add more filters










Publication year range
1.
J Microsc ; 295(2): 140-146, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38372408

ABSTRACT

Atomic electric fields in a thin GaN sample are measured with the centre-of-mass approach in 4D-scanning transmission electron microscopy (4D-STEM) using a 12-segmented STEM detector in a Spectra 300 microscope. The electric fields, charge density and potential are compared to simulations and an experimental measurement using a pixelated 4D-STEM detector. The segmented detector benefits from a high recording speed, which enables measurements at low radiation doses. However, there is measurement uncertainty due to the limited number of segments analysed in this study.

2.
Adv Mater ; 35(28): e2211104, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37029337

ABSTRACT

The development of a novel reactive spray technology based on the well-known gas-phase metal oxide synthesis route provides innumerable opportunities for the production of non-oxide nanoparticles. Among these materials, metal sulfides are expected to have a high impact, especially in the development of electrochemical and photochemical high-surface-area materials. As a proof-of-principle, MnS, CoS, Cu2 S, ZnS, Ag2 S, In2 S3 , SnS, and Bi2 S3 are synthesized in an O2 -lean and sulfur-rich environment. In addition, the formation of Cu2 S in a single-droplet combustion experiment is reported. The multiscale approach combining flame sprays with single-droplet combustion is expected to pave the way toward a fundamental understanding of the gas-phase formation of metal sulfides in the future. The knowledge acquired can open the possibility for the development of a next-generation gas-phase technology facilitating the scalable synthesis of functional binary/ternary metal sulfides.


Subject(s)
Nanoparticles , Oxygen , Temperature , Aerosols , Sulfides
3.
Ultramicroscopy ; 245: 113661, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36529039

ABSTRACT

The ISTEM mode for TEM has been demonstrated to have several advantages in regard to resolution and precision. While previous works primarily focussed on the advantages due to the reduced spatial coherence, the actual image contrast, i.e. how bright or dark certain atom columns are imaged, has mostly been of secondary concern. The present work sets out to achieve the contrast of annular bright field STEM in ISTEM, producing the high contrast of light elements, for which this method is popular. It is shown from theoretical considerations that using an annular condenser aperture this aim can be realised. The optimal size of this aperture is found by simulative studies. It is then manufactured from platinum foil and installed in an image-aberration corrected microscope. ABF-like ISTEM images of strontium titanate in [100] projection are acquired. The pure oxygen columns are clearly resolved with significant contrast. The image pattern is indeed identical to what is achieved by ABF STEM. A close look at the image formation also shows that the dose needed for a given signal-to-noise ratio is at least a quarter smaller for ABF-like ISTEM compared to ABF STEM, assuming detectors of similar detective quantum efficiency.

4.
Ultramicroscopy ; 238: 113535, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35526315

ABSTRACT

In this paper we perform angular resolved annular-dark field (ADF) scanning-transmission electron microscopy (STEM) to study the scattered intensity in an InGaN layer buried in GaN as a function of the scattering angle. We achieved angular resolution with a motorized iris aperture in front of the ADF detector. Using this setup, we investigated how the intensities measured in various angular ranges agree with multislice simulations in the frozen-lattice approximation. We observed a strong influence of relaxation induced surface-strain fields on the ADF intensity, measured its angular characteristics and compared the result with simulations. To assess the agreement of the measured intensity with simulations, we evaluated the specimen thickness in GaN and the indium concentration in InGaN for each angular interval by comparing the measured intensities with simulations. The thickness was strongly overestimated for scattering angles below 40mrad and also the evaluated indium concentration varies with the considered angular range. Using simulations, we investigated which angular ranges show a high sensitivity to variations of the thickness and which intervals strongly depend on the indium concentration. By combining two angular intervals, the indium concentration and the specimen thickness were determined simultaneously, which has potential advantages over the usual quantification method. It is shown that inelastic scattering, surface contamination and mistilt can have an influence on the measured intensity, especially at lower scattering angles below 30-50mrad, which might explain the observed difference between the frozen lattice simulation and the experiment.

5.
Ultramicroscopy ; 236: 113503, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35278874

ABSTRACT

The measurement of electric fields in scanning transmission electron microscopy (STEM) is a highly investigated field of research. The constant improvement of spatial resolution in STEM and the development of new hardware for the fast acquisition of diffraction patterns even paved the way for the measurement of atomic electric fields. Although the basic principle that an electric field leads to a tilt of the focussed electron probe that can be detected as a shift of the diffraction pattern in the back focal plane of the objective lens seems quite simple, many challenges arose in the measurement of fields in a quantitative way. In the present study we investigate whether a shift of the diffraction pattern that occurs at an interface between two materials can be related to the electric field which is caused by the difference of the mean inner potentials of the two materials. To this end, experiments and simulations are compared. It is demonstrated that the difference in mean inner potential has an influence on the observed effect, but a quantitative interpretation is difficult. The influence of image recording effects such as shot noise and the modulation transfer function are investigated as well as further effects such as e.g. sample tilt. In addition, the influence of the observed effect on a strain measurement is shown.

6.
ChemistryOpen ; 10(7): 697-712, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34251087

ABSTRACT

Porous networks of Pt nanoparticles interlinked by bifunctional organic ligands have shown high potential as catalysts in micro-machined hydrogen gas sensors. By varying the ligand among p-phenylenediamine, benzidine, 4,4''-diamino-p-terphenyl, 1,5-diaminonaphthalene, and trans-1,4-diaminocyclohexane, new variants of such networks were synthesized. Inter-particle distances within the networks, determined via transmission electron microscopy tomography, varied from 0.8 to 1.4 nm in accordance with the nominal length of the respective ligand. While stable structures with intact and coordinatively bonded diamines were formed with all ligands, aromatic diamines showed superior thermal stability. The networks exhibited mesoporous structures depending on ligand and synthesis strategy and performed well as catalysts in hydrogen gas microsensors. They demonstrate the possibility of deliberately tuning micro- and mesoporosity and thereby transport properties and steric demands by choice of the right ligand also for other applications in heterogeneous catalysis.

7.
Microsc Microanal ; 27(4): 678-686, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34085625

ABSTRACT

Quantitative structural characterization of nanomaterials is important to tailor their functional properties. Corrosion of AgAu-alloy nanoparticles (NPs) results in porous structures, making them interesting for applications especially in the fields of catalysis and surface-enhanced Raman spectroscopy. For the present report, structures of dealloyed NPs were reconstructed three-dimensionally using scanning transmission electron microscopy tomography. These reconstructions were evaluated quantitatively, revealing structural information such as pore size, porosity, specific surface area, and tortuosity. Results show significant differences compared to the structure of dealloyed bulk samples and can be used as input for simulations of diffusion or mass transport processes, for example, in catalytic applications.

8.
Materials (Basel) ; 14(9)2021 May 04.
Article in English | MEDLINE | ID: mdl-34064513

ABSTRACT

The film thickness plays an important role in the performance of materials applicable to different technologies including chemical sensors, catalysis and/or energy materials. The relationship between the surface and volume of the functional layers is key to high performance evaluations. Here we demonstrate the thermophoretic deposition of different thicknesses of the functional layers designed using flame combustion of tin 2-ethylhexanoate dissolved in xylene, and measurement of thickness by scanning electron microscopy and focused ion beam. The parameters such as spray fluid concentration (differing Sn2+ content), substrate-nozzle distance and time of the spray were considered to investigate the layer growth. The results showed ≈ 23, 124 and 161 µm thickness of the SnO2 layer after flame spray of 0.1, 0.5 M and 1.0 M tin 2-EHA-Xylene solutions for 1200 s. While Sn2+ concentration was 0.5 M for all the flame sprays, the substrates placed at 250, 220 and 200 mm from the flame nozzle had layer thicknesses of 113, 116 and 132 µm, respectively. Spray time dependent thickness growth showed a linear increase from 8.5 to 152.1 µm when the substrates were flame sprayed for 30 s to 1200 s using 0.5 M tin 2-EHA-Xylene solutions. Changing the dispersion oxygen flow (3-7 L/min) had almost no effect on layer thickness. Layers fabricated were compared to a model found in literature, which seems to describe the thickness well in the domain of varied parameters. It turned out that primary particle size deposited on the substrate can be tuned without altering the layer thickness and with little effect on porosity. Applications depending on porosity, such as catalysis or gas sensing, can benefit from tuning the layer thickness and primary particle size.

9.
Ultramicroscopy ; 228: 113321, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34175788

ABSTRACT

4D-scanning transmission electron microscopy (4D-STEM) can be used to measure electric fields such as atomic fields or polarization-induced electric fields in crystal heterostructures. The paper focuses on effects occurring in 4D-STEM at interfaces, where two model systems are used: an AlN/GaN nanowire superlattice as well as a GaN/vacuum interface. Two different methods are applied: First, we employ the centre-of mass (COM) technique which uses the average momentum transfer evaluated from the intensity distribution in the diffraction pattern. Second, we measure the shift of the undiffracted disc (disc-detection method) in nano-beam electron diffraction (NBED). Both methods are applied to experimental and simulated 4D-STEM data sets. We find for both techniques distinct variations in the momentum transfer at interfaces between materials: In both model systems, peaks occur at the interfaces and we investigate possible sources and routes of interpretation. In case of the AlN/GaN superlattice, the COM and disc-detection methods are used to measure internal polarization-induced electric fields and we observed a reduction of the measured fields with increasing specimen thickness.

10.
ACS Appl Energy Mater ; 4(5): 4428-4443, 2021 May 24.
Article in English | MEDLINE | ID: mdl-34060544

ABSTRACT

The spinel LiMn2O4 (LMO) is a promising cathode material for rechargeable Li-ion batteries due to its excellent properties, including cost effectiveness, eco-friendliness, high energy density, and rate capability. The commercial application of LiMn2O4 is limited by its fast capacity fading during cycling, which lowers the electrochemical performance. In the present work, phase-pure and crystalline LiMn2O4 spinel in the nanoscale were synthesized using single flame spray pyrolysis via screening 16 different precursor-solvent combinations. To overcome the drawback of capacity fading, LiMn2O4 was homogeneously mixed with different percentages of AlPO4 using versatile multiple flame sprays. The mixing was realized by producing AlPO4 and LiMn2O4 aerosol streams in two independent flames placed at 20° to the vertical axis. The structural and morphological analyses by X-ray diffraction indicated the formation of a pure LMO phase and/or AlPO4-mixed LiMn2O4. Electrochemical analysis indicated that LMO nanoparticles of 17.8 nm (d BET) had the best electrochemical performance among the pure LMOs with an initial capacity and a capacity retention of 111.4 mA h g-1 and 88% after 100 cycles, respectively. A further increase in the capacity retention to 93% and an outstanding initial capacity of 116.1 mA h g-1 were acquired for 1% AlPO4.

11.
Ultramicroscopy ; 227: 113325, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34045084

ABSTRACT

In this paper we study the effect of lens aberrations (spherical aberration and astigmatism), beam tilt, contamination and shot noise on the accuracy and precision of position determination in imaging scanning transmission electron microscopy (ISTEM) on the example of BaTiO3. ISTEM images are simulated as a function of sample thickness and defocus starting from a nearly perfect microscope setting. A defocus range was identified, in which atom column positions were reliably visible and could be decently measured. By averaging over this defocus and thickness range a figure of merit was defined and used to study the influence of above mentioned disturbing effects as a function of their strength. It turned out that column positions might become inaccurate, but distances are measured accurately. These were used to obtain recommendations for the experimental setup to measure the atomic arrangement that induces ferroelectric switching of BaTiO3.

12.
Ultramicroscopy ; 223: 113221, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33588232

ABSTRACT

Modern quantitative TEM methods such as the ζ-factor technique require precise knowledge of the electron beam current. To this end, a macroscopic Faraday cup was designed and constructed. It can replace the viewing screen in the projection chamber of a TEM and guarantees highly accurate measurement of the electron beam with precision only limited by the used amperemeter. The easy to install, affordable device is shown to be highly apt for precision measurement of currents >5pA. The Faraday cup results are used for an assessment and a comparison of various other beam current measurement methods. It is found that the built-in screen amperemeter of the used TEM is quite inaccurate and that measurements using the screen in general tend to underestimate the current. If present, the drift tube of a spectrometer can also be used as a Faraday cup, but certain described peculiarities have to be taken into account. Direct ultrafast electron detection cameras allow precise measurement at very small currents. For the electron counting technique, which exploits single electron detection capabilities of STEM detectors, a systematic current underestimation was observed and investigated. This results in a reformulated routine for the method and with these improvements it is demonstrated to be capable of accurate high-precision measurements for currents <5pA.

13.
Ultramicroscopy ; 221: 113196, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33341079

ABSTRACT

Strain analysis by nano-beam electron diffraction allows for measurements of strain with nanometre resolution in a large field of view. This is done by evaluating distances between diffraction discs in diffraction patterns acquired while a focussed electron beam is scanned across the sample in a transmission electron microscope. The bottleneck of this method is a precise determination of diffraction disc positions, which suffers from the inner structure of the discs caused by dynamical diffraction. Electron beam precession is a tool that solves this problem but it is not commonly available in every microscope. Without precession significant progress has been reported recently by using patterned condenser apertures. The pattern of the aperture is reproduced in patterns of the diffraction discs allowing for a more precise position determination. In this report the accuracy of measured strain profiles using patterned apertures is investigated by evaluation of realistic simulations. This is done especially at interfaces between regions with different lattice plane spacing. It is found by evaluation of the simulations that measured strain profiles are more blurred and hence the accuracy at the interface is worse the more patterns are imprinted to the condenser aperture. An explanation of this effect is given and as a proof of principle a solution to this problem is provided applying geometric phase analysis ptychography.

14.
Ultramicroscopy ; 221: 113175, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33383361

ABSTRACT

The angle-resolved electron scattering is investigated in scanning-transmission electron microscopy (STEM) using a motorised iris aperture placed above a conventional annular detector. The electron intensity scattered into various angle ranges is compared with simulations that were carried out in the frozen-lattice approximation. As figure of merit for the agreement of experiment and simulation we evaluate the specimen thickness which is compared with the thickness obtained from position-averaged convergent beam electron diffraction (PACBED). We find deviations whose strengths depend on the angular range of the detected electrons. As possible sources of error we investigate, for example, the influences of amorphous surface layers, inelastic scattering (plasmon excitation), phonon-correlation within the frozen-lattice approach, and distortions in the diffraction plane of the microscope. The evaluation is performed for four experimental thicknesses and two angle-resolved STEM series under different camera lengths. The results clearly show that especially for scattering angles below 50 mrad, it is mandatory that the simulations take scattering effects into account which are usually neglected for simulating high-angle scattering. Most influences predominantly affect the low-angle range, but also high scattering angles can be affected (e.g. by amorphous surface covering).

15.
Sci Rep ; 10(1): 17890, 2020 Oct 21.
Article in English | MEDLINE | ID: mdl-33087734

ABSTRACT

Scanning transmission electron microscopy (STEM) allows to gain quantitative information on the atomic-scale structure and composition of materials, satisfying one of todays major needs in the development of novel nanoscale devices. The aim of this study is to quantify the impact of inelastic, i.e. plasmon excitations (PE), on the angular dependence of STEM intensities and answer the question whether these excitations are responsible for a drastic mismatch between experiments and contemporary image simulations observed at scattering angles below [Formula: see text] 40 mrad. For the two materials silicon and platinum, the angular dependencies of elastic and inelastic scattering are investigated. We utilize energy filtering in two complementary microscopes, which are representative for the systems used for quantitative STEM, to form position-averaged diffraction patterns as well as atomically resolved 4D STEM data sets for different energy ranges. The resulting five-dimensional data are used to elucidate the distinct features in real and momentum space for different energy losses. We find different angular distributions for the elastic and inelastic scattering, resulting in an increased low-angle intensity ([Formula: see text] 10-40 mrad). The ratio of inelastic/elastic scattering increases with rising sample thickness, while the general shape of the angular dependency is maintained. Moreover, the ratio increases with the distance to an atomic column in the low-angle regime. Since PE are usually neglected in image simulations, consequently the experimental intensity is underestimated at these angles, which especially affects bright field or low-angle annular dark field imaging. The high-angle regime, however, is unaffected. In addition, we find negligible impact of inelastic scattering on first-moment imaging in momentum-resolved STEM, which is important for STEM techniques to measure internal electric fields in functional nanostructures. To resolve the discrepancies between experiment and simulation, we present an adopted simulation scheme including PE. This study highlights the necessity to take into account PE to achieve quantitative agreement between simulation and experiment. Besides solving the fundamental question of missing physics in established simulations, this finally allows for the quantitative evaluation of low-angle scattering, which contains valuable information about the material investigated.

16.
Combust Flame ; 215: 389-400, 2020 May.
Article in English | MEDLINE | ID: mdl-32903291

ABSTRACT

Tin dioxide (SnO2) nanoparticles synthesized via flame spray pyrolysis (FSP) have promising applications for gas sensors. The formation of SnO2 nanoparticles in the gas-phase has been investigated using single droplet combustion and FSP. Precursor solutions of Tin (II) 2-ethylhexanoate dissolved in Xylene with varying Sn concentrations were selected as the precursor-solvent system. The selected precursor-solvent system has its stability and ability to synthesize homogeneous nanoparticles, compared to metal nitrate based precursor solutions. The precursor-solvent system was studied using attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy and thermogravimetric analysis (TGA). The SnO2 nanoparticles were characterized using X-ray diffraction (XRD), Brunauer-Emmett-Teller (BET), and transmission electron microscopy (TEM). Droplet surface micro-explosions were observed during the single droplet combustion of the precursor solutions. It is because of the heterogeneous vapor-phase nucleation, which is beneath the liquid droplet surface and caused by precursor thermal decomposition. The results show that the size of nanoparticles obtained both from FSP and single droplet combustion increases with increasing metal-precursor concentration. The TEM images of the particles from such droplet combustion reveal two types of nanoparticles with different sizes and morphologies. The current work provides fundamental understanding of precursor decomposition and particle formation during single droplet combustion, which help in-depth understanding of the flame spray pyrolysis.

17.
Ultramicroscopy ; 196: 74-82, 2019 01.
Article in English | MEDLINE | ID: mdl-30291992

ABSTRACT

Images acquired in transmission electron microscopes can be distorted for various reasons such as e.g. aberrations of the lenses of the imaging system or inaccuracies of the image recording system. This results in inaccuracies of measures obtained from the distorted images. Here we report on measurement and correction of elliptical distortions of diffraction patterns. The effect of this correction on the measurement of crystal lattice strain is investigated. We show that the effect of the distortions is smaller than the precision of the measurement in cases where the strain is obtained from shifts of diffracted discs with respect to their positions in images acquired in an unstrained reference area of the sample. This can be explained by the fact that diffraction patterns acquired in the strain free reference area of the sample are distorted in the same manner as the diffraction patterns acquired in the strained region of interest. In contrast, for samples without a strain free reference region such as nanoparticles or nanoporous structures, where we evaluate ratios of lattice plane distances along different directions, the distortions are usually not negligible. Furthermore, two techniques for the detection of diffraction disc positions are compared showing that for samples in which the crystal orientation changes over the investigated area it is more precise to detect the positions of many diffraction discs simultaneously instead of detecting each disc position independently.

18.
Ultramicroscopy ; 190: 45-57, 2018 07.
Article in English | MEDLINE | ID: mdl-29783102

ABSTRACT

Strain analyses from experimental series of nano-beam electron diffraction (NBED) patterns in scanning transmission electron microscopy are performed for different specimen tilts. Simulations of NBED series are presented for which strain analysis gives results that are in accordance with experiment. This consequently allows to study the relation between measured strain and actual underlying strain. A two-tilt method which can be seen as lowest-order electron beam precession is suggested and experimentally implemented. Strain determination from NBED series with increasing beam convergence is performed in combination with the experimental realization of a probe-forming aperture with a cross inside. It is shown that using standard evaluation techniques, the influence of beam convergence on spatial resolution is lower than the influence of sharp rings around the diffraction disc which occur at interfaces and which are caused by the tails of the intensity distribution of the electron probe.

20.
Ultramicroscopy ; 189: 124-135, 2018 06.
Article in English | MEDLINE | ID: mdl-29660631

ABSTRACT

For simulation of transmission electron microscopic images and diffraction patterns, the accurate inclusion of thermal diffuse scattering by phonons is important. In the frozen phonon multislice algorithm, this is possible, if thermal displacements according to the realistic, quantum mechanical distribution can be generated. For pure crystals, quantum mechanical calculations based on DFT yield those displacements. But for alloys one is usually restricted to the Einstein approximation, where correlations between atoms are neglected. In this article, molecular dynamics simulations are discussed and used as an alternative method for displacement calculation. Employing an empirical Stillinger-Weber type potential, classical motion is used as an approximation for the quantum mechanical dynamics. Thereby, correlations and possible static atomic displacements are inherently included. An appropriate potential is devised for AlGaN by fitting to force constant matrices determined from DFT and elastic constants of AlN and GaN. A comparison shows that the empiric potential reproduces phonon dispersions and displacement expectations from DFT references. The validity for alloys is successfully demonstrated by comparison to DFT calculations in special quasirandom structures. Subsequently, molecular dynamics were used in multislice simulations of both conventional and scanning TEM images. The resulting images are in very good agreement with DFT based calculations, while a slight yet significant deviation from Einstein approximation results can be seen, which can be attributed to the neglect of correlations in the latter. The presented potential hence proves to be a useful tool for accurate TEM simulations of AlGaN alloys.

SELECTION OF CITATIONS
SEARCH DETAIL
...