1.
Invest Radiol ; 43(6): 439-46, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18496050

ABSTRACT

OBJECTIVE: Dynamic ventilation (3)He-MRI is a new method to assess pulmonary gas inflow. As differing airway diameters throughout the ventilatory cycle can influence gas inflow this study intends to investigate the influence of volume and timing of a He gas bolus with respect to the beginning of the tidal volume on inspiratory gas distribution. MATERIALS AND METHODS: An ultrafast 2-dimensional spoiled gradient echo sequence (temporal resolution 100 milliseconds) was used for dynamic ventilation (3)He-MRI of 11 anesthetized and mechanically ventilated pigs. The applied (3)He gas bolus was varied in volume between 100 and 200 mL. A 150-mL bolus was varied in its application time after the beginning of the tidal volume between 0 and 1200 milliseconds. Signal kinetics were evaluated using an in-house developed software after definition of parameters for the quantitative description of (3)He gas inflow. RESULTS: The signal rise time (time interval between signal in the parenchyma reaches 10% and 90% of its maximum) was prolonged with increasing bolus volume. The parameter was shortened with increasing delay of (3)He application after the beginning of the tidal volume. Timing variation as well as volume variation showed no clear interrelation to the signal delay time 10 (time interval between signal in the trachea reaches 50% of its maximum and signal in the parenchyma reaches 10% of its maximum). CONCLUSIONS: Dynamic ventilation (3)He-MRI is able to detect differences in bolus geometry performed by volume variation. Pulmonary gas inflow as investigated by dynamic ventilation (3)He-MRI tends to be accelerated by an increasing application delay of a (3)He gas bolus after the beginning of the tidal volume.


Subject(s)
Helium/pharmacokinetics , Lung/physiology , Magnetic Resonance Imaging/methods , Administration, Inhalation , Animals , Isotopes , Lung/metabolism , Pulmonary Gas Exchange/physiology , Pulmonary Ventilation/physiology , Software , Swine
2.
Eur Radiol ; 18(3): 530-7, 2008 Mar.
Article in English | MEDLINE | ID: mdl-17926041

ABSTRACT

Oxygen-sensitive 3He-MRI was studied for the detection of differences in intrapulmonary oxygen partial pressure (pO2) between patients with normal lung transplants and those with bronchiolitis obliterans syndrome (BOS). Using software developed in-house, oxygen-sensitive 3He-MRI datasets from patients with normal lung grafts (n = 8) and with BOS (n = 6) were evaluated quantitatively. Datasets were acqiured on a 1.5-T system using a spoiled gradient echo pulse sequence. Underlying diseases were pulmonary emphysema (n = 10 datasets) and fibrosis (n = 4). BOS status was verified by pulmonary function tests. Additionally, 3He-MRI was assessed blindedly for ventilation defects. Median intrapulmonary pO2 in patients with normal lung grafts was 146 mbar compared with 108 mbar in patients with BOS. Homogeneity of pO2 distribution was greater in normal grafts (standard deviation pO2 34 versus 43 mbar). Median oxygen decrease rate during breath hold was higher in unaffected patients (-1.75 mbar/s versus -0.38 mbar/s). Normal grafts showed fewer ventilation defects (5% versus 28%, medians). Oxygen-sensitive 3He-MRI appears capable of demonstrating differences of intrapulmonary pO2 between normal lung grafts and grafts affected by BOS. Oxygen-sensitive 3He-MRI may add helpful regional information to other diagnostic techniques for the assessment and follow-up of lung transplant recipients.


Subject(s)
Bronchiolitis Obliterans/diagnosis , Helium , Lung Transplantation , Magnetic Resonance Imaging/methods , Oxygen/analysis , Adult , Bronchiolitis Obliterans/complications , Female , Follow-Up Studies , Humans , Male , Middle Aged , Partial Pressure , Retrospective Studies
3.
Eur Radiol ; 14(1): 78-85, 2004 Jan.
Article in English | MEDLINE | ID: mdl-14564471

ABSTRACT

The aim of this study was to evaluate the possible contribution of (3)He-MRI to detect obliterative bronchiolitis (OB) in the follow-up of lung transplant recipients. Nine single- and double-lung transplanted patients were studied by an initial and a follow-up (3)He-MRI study. Images were evaluated subjectively by estimation of ventilation defect area and quantitatively by individually adapted threshold segmentation and subsequent calculation of ventilated lung volume. Bronchiolitis obliterans syndrome (BOS) was diagnosed using pulmonary function tests. At (3)He-MRI, OB was suspected if ventilated lung volume had decreased by 10% or more at the follow-up MRI study compared with the initial study. General accordance between pulmonary function testing and (3)He-MRI was good, although subjective evaluation of (3)He-MRI underestimated improvement in ventilation as obtained by pulmonary function tests. The (3)He-MRI indicated OB in 6 cases. According to pulmonary function tests, BOS was diagnosed in 5 cases. All diagnoses of BOS were also detected by (3)He-MRI. In 2 of these 5 cases, (3)He-MRI indicated OB earlier than pulmonary function tests. The results support the hypothesis that (3)He-MRI may be sensitive for early detection of OB and emphasize the need for larger prospective follow-up studies.


Subject(s)
Bronchiolitis Obliterans/diagnosis , Helium , Lung Transplantation/adverse effects , Magnetic Resonance Imaging/methods , Radiographic Image Enhancement , Adult , Female , Graft Rejection , Graft Survival , Humans , Image Interpretation, Computer-Assisted , Lung Transplantation/methods , Male , Middle Aged , Monitoring, Physiologic/methods , Postoperative Care/methods , Prognosis , Respiratory Function Tests , Retrospective Studies , Risk Assessment , Sensitivity and Specificity , Severity of Illness Index
SELECTION OF CITATIONS