1.
Med Phys ; 35(11): 4945-54, 2008 Nov.
Article in English | MEDLINE | ID: mdl-19070228

ABSTRACT

A proton beam delivery system on a gantry with continuous uniform scanning and dose layer stacking at the Midwest Proton Radiotherapy Institute has been commissioned and accepted for clinical use. This paper was motivated by a lack of guidance on the testing and characterization for clinical uniform scanning systems. As such, it describes how these tasks were performed with a uniform scanning beam delivery system. This paper reports the methods used and important dosimetric characteristics of radiation fields produced by the system. The commissioning data include the transverse and longitudinal dose distributions, penumbra, and absolute dose values. Using a 208 MeV cyclotron's proton beam, the system provides field sizes up to 20 and 30 cm in diameter for proton ranges in water up to 27 and 20 cm, respectively. The dose layer stacking method allows for the flexible construction of spread-out Bragg peaks with uniform modulation of up to 15 cm in water, at typical dose rates of 1-3 Gy/min. For measuring relative dose distributions, multielement ion chamber arrays, small-volume ion chambers, and radiographic films were employed. Measurements during the clinical commissioning of the system have shown that the lateral and longitudinal dose uniformity of 2.5% or better can be achieved for all clinically important field sizes and ranges. The measured transverse penumbra widths offer a slight improvement in comparison to those achieved with a double scattering beam spreading technique at the facility. Absolute dose measurements were done using calibrated ion chambers, thermoluminescent and alanine detectors. Dose intercomparisons conducted using various types of detectors traceable to a national standards laboratory indicate that the measured dosimetry data agree with each other within 5%.


Subject(s)
Proton Therapy , Radiation Dosage , Radiometry/methods , Humans
2.
Int J Med Robot ; 3: 72-81, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17441029

ABSTRACT

BACKGROUND: Protons beams deliver targeted radiation doses with greater precision than is possible with electrons or megavoltage X-ray photons, but to retain this advantage, patient positioning systems at proton clinics must meet tighter accuracy requirements. For this and other reasons, robots were incorporated into the treatment room systems at MPRI. METHODS: The Midwest Proton Radiotherapy Institute (MPRI) is the first radiotherapy facility in the United States to use commercial robots with six degrees of freedom for patient positioning, rather than a traditional bed with four degrees of freedom. RESULTS: This paper outlines the ways in which robots are used at MPRI and attempts to distil insights from the experience of treating over 200 radiotherapy patients with a robotic system from February 2004 to late 2006. CONCLUSIONS: The system has performed well, and with great reliability, but there is room for future improvement, especially in ease of use and in reducing the time to get patients into position.


Subject(s)
Posture , Proton Therapy , Radiotherapy, Computer-Assisted/instrumentation , Radiotherapy, Computer-Assisted/methods , Radiotherapy, Conformal/instrumentation , Restraint, Physical/instrumentation , Robotics/instrumentation , Equipment Design , Humans , Industry/instrumentation , Radiotherapy, Conformal/methods , Restraint, Physical/methods , Robotics/methods , Technology Assessment, Biomedical
3.
Phys Med Biol ; 48(10): 1345-59, 2003 May 21.
Article in English | MEDLINE | ID: mdl-12812451

ABSTRACT

The ICRU tissue to A-150 tissue equivalent plastic kerma ratio is needed for neutron therapy dosimetry. The current ICRU protocol for neutron dosimetry recommends using a common conversion factor of 0.95 at all high-energy neutron therapy facilities. In an effort to determine facility specific ICRU tissue to A-150 plastic kerma ratios, an experimental approach was pursued. Four low pressure proportional counters that differed in wall materials (i.e. A-150, carbon, zirconium and zirconium-oxide) were used as dosimeters and integral kerma ratios were determined directly in the clinical beam. Measurements were performed at two p(66)Be facilities: iThemba LABS near Cape Town and Fermilab near Chicago. At the iThemba facility the clinical neutron beam is routinely filtered by a flattening and hardening filter combination. The influence of beam filtration on the kerma ratio was evaluated. Using two recent gas-to-wall dose conversion factor (r(m,g) value) evaluations a mean ICRU tissue to A-150 plastic kerma ratio of 0.93 +/- 0.05 was determined for the clinical beam at iThemba LABS. The respective value for the Fermilab beam is 0.95 +/- 0.05. The experimentally determined ICRU tissue to A-150 plastic kerma ratios for the two clinical beams are in agreement with theoretical evaluations. Beam filtration reduces the kerma ratio by 3 +/- 2%.


Subject(s)
Fast Neutrons/therapeutic use , Radiotherapy Planning, Computer-Assisted/statistics & numerical data , Biophysical Phenomena , Biophysics , Humans , Neoplasms/radiotherapy , Phantoms, Imaging , Plastics , Radiometry/instrumentation
4.
Radiother Oncol ; 61(2): 177-84, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11690684

ABSTRACT

BACKGROUND AND PURPOSE: To determine the influence of the number of fractions (or the dose per fraction) on the proton relative biological effectiveness (RBE). MATERIALS AND METHODS: Intestinal crypt regeneration in mice was used as the biological endpoint. RBE was determined relative to cobalt-60 gamma rays for irradiations in one, three and ten fractions separated by a time interval of 3.5h. Proton irradiations were performed at the middle of a 7-cm Spread Out Bragg Peak (SOBP). RESULTS: Proton RBEs (and corresponding gamma dose per fraction) at the level of 20 regenerated crypts per circumference were found equal to 1.15+/-0.04 (10.0 Gy), 1.15+/-0.05 (4.8 Gy) and 1.14+/-0.07 (1.7 Gy) for irradiations in one, three and ten fractions, respectively. Alpha/beta ratios as derived from direct analysis of the 'quantal radiation response data' were found to be 7.6 Gy for gamma rays and 8.2 Gy for protons. Additional proton irradiations in ten fractions at the end of the SOBP were found to be more effective than at the middle of the SOBP by a factor of 1.14 (1.05-1.23). CONCLUSION: Proton RBE for crypt regeneration was found to be independent of fractionation up to ten fractions. One can expect that it remains unchanged for higher number of fractions as the lethalities for doses smaller than 3 Gy are exclusively due to direct lethal events. As a tendency for increased effectiveness at the end of the SOBP is reported in the majority of the studies, for clinical applications it would be advisable to allow for by arranging a sloping depth dose curve in the deeper part of the target volume. Finally, it must be noticed that most of in vitro and in vivo RBE values for protons are larger than the current clinical RBE (RBE=1.10).


Subject(s)
Dose Fractionation, Radiation , Intestines/radiation effects , Radiation Tolerance , Animals , Female , Gamma Rays , Intestines/pathology , Intestines/physiology , Male , Mice , Mice, Inbred BALB C , Protons , Radiotherapy, High-Energy , Random Allocation , Regeneration , Whole-Body Irradiation
5.
Int J Radiat Oncol Biol Phys ; 47(4): 1051-8, 2000 Jul 01.
Article in English | MEDLINE | ID: mdl-10863078

ABSTRACT

PURPOSE: This study aims at providing relative biological effectiveness (RBE) data under reference conditions accounting for the determination of the "clinical RBE" of protons. METHODS AND MATERIALS: RBE (ref. (60)Co gamma-rays) of the 200 MeV clinical proton beam produced at the National Accelerator Centre (South Africa) was determined for lung tolerance assessed by survival after selective irradiation of the thorax in mice. Irradiations were performed in 1, 3, or 10 fractions separated by 12 h. Proton irradiations were performed at the middle of a 7-cm spread out Bragg peak (SOBP). Control gamma irradiations were randomized with proton irradiations and performed simultaneously. A total of 1008 mice was used, of which 96 were assessed for histopathology. RESULTS: RBEs derived from LD50 ratios were found not to vary significantly with fractionation (corresponding dose range, approximately 2-20 Gy). They, however, tend to increase with time and reach (mean of the RBEs for 1, 3 and 10 fractions) 1.00, 1.08, 1.14, and 1.25 for LD50 at 180, 210, 240, and 270 days, respectively (confidence interval approximately 20%). alpha/beta ratios for protons and gamma are very similar and average 2.3 (0.6-4.8) for the different endpoints. Additional irradiations in 10 fractions at the end of the SOBP were found slightly more effective ( approximately 6%) than at the middle of the SOBP. A control experiment for intestinal crypt regeneration in mice was randomized with the lung experiment and yielded an RBE of 1.14 +/- 0.03, i.e., the same value as obtained previously, which vouches for the reliability of the experimental procedure. CONCLUSION: There is no need to raise the clinical RBE of protons in consideration of the late tolerance of healthy tissues in the extent that RBE for lung tolerance was found not to vary with fractionation nor to differ significantly from those of the majority of early- and late-responding tissues.


Subject(s)
Lung/radiation effects , Protons , Radiation Tolerance , Relative Biological Effectiveness , Animals , Confidence Intervals , Dose Fractionation, Radiation , Dose-Response Relationship, Radiation , Female , Lung/physiology , Mice , Mice, Inbred BALB C , Radiobiology
6.
Strahlenther Onkol ; 175 Suppl 2: 10-2, 1999 Jun.
Article in English | MEDLINE | ID: mdl-10394385

ABSTRACT

A three-dimensional proton treatment planning system called PROXELPLAN has been used at the National Accelerator Centre (NAC) since October 1994. This system is entirely based on the VOXELPLAN planning system, developed at the Deutches Krebsforschungszentrum (DKFZ), Heidelberg, Germany. The VOXELPLAN system provides the treatment planning infrastructure while the proton dose distributions are calculated using a software module that was initially developed at the Royal Marsden Hospital, UK. The proton module has been extensively modified and refined. It uses a rayline-tracing algorithm which is suitable for planning current treatments but is not sufficiently dynamic to accommodate the use of compensators. A sophisticated pencil beam algorithm is currently under development.


Subject(s)
Proton Therapy , Radiotherapy Planning, Computer-Assisted , Algorithms , Humans , Phantoms, Imaging , Tomography, X-Ray Computed , Water
7.
Strahlenther Onkol ; 175 Suppl 2: 30-2, 1999 Jun.
Article in English | MEDLINE | ID: mdl-10394392

ABSTRACT

The 200 MeV cyclotron facility at the National Accelerator Centre has been operational since 1987. Between September 1988 and December 1997 a total of 973 patients (26,916 fields) had been treated on the 66 MeV p+Be isocentric neutron therapy system. Patients are currently being treated according to several protocols, including tumors of the head and neck, salivary gland and breast and soft tissue sarcomas, uterine sarcomas and paranasal sinuses. A multiblade post-collimator trimmer has recently being installed. This device provides improved neutron beam shaping capability. Between September 1993 and December 1997 a total of 243 patients (4008 fields) had been treated (mainly intracranial stereotactic irradiations) on the fixed horizontal 200 MeV proton therapy facility. The facility incorporates an innovative automatic patient positioning system. Two new fixed beam lines for proton therapy are presently being designed (horizontal and 30 degrees to the vertical) for an existing unused treatment vault. Spot scanning systems will be developed for both beam lines.


Subject(s)
Head and Neck Neoplasms/radiotherapy , Neoplasms/radiotherapy , Particle Accelerators , Radiotherapy Planning, Computer-Assisted , Humans , Neutrons/therapeutic use , Phantoms, Imaging , Proton Therapy , South Africa
8.
Radiother Oncol ; 42(3): 303-9, 1997 Mar.
Article in English | MEDLINE | ID: mdl-9155083

ABSTRACT

BACKGROUND AND PURPOSE: Thorough knowledge of the RBE of clinical proton beams is indispensable for exploiting their full ballistic advantage. Therefore, the RBE of the 200-MeV clinical proton beam produced at the National Accelerator Centre of Faure (South Africa) was measured at different critical points of the depth-dose distribution. MATERIAL AND METHODS: RBEs were determined at the initial plateau of the unmodulated and modulated beam (depth in Perspex = 43.5 mm), and at the beginning, middle and end of a 7-cm spread-out Bragg peak (SOBP) (depths in Perspex = 144.5, 165.5 and 191.5 mm, respectively). The biological system was the regeneration of intestinal crypts in mice after irradiation with a single fraction. RESULTS: Using 60Co gamma-rays as the reference, the RBE values (for a gamma-dose of 14.38 Gy corresponding to 10 regenerated crypts) were found equal to 1.16 +/- 0.04, 1.10 +/- 0.03, 1.18 +/- 0.04, 1.12 +/- 0.03 and 1.23 +/- 0.03, respectively. At all depths, RBEs were found to increase slightly (about 4%) with decreasing dose, in the investigated dose range (12-17 Gy). No significant RBE variation with depth was observed, although RBEs in the SOBP were found to average a higher value (1.18 +/- 0.06) than in the entrance plateau (1.13 +/- 0.04). CONCLUSION: An RBE value slightly larger than the current value of 1.10 should be adopted for clinical application with a 200-MeV proton beam.


Subject(s)
Particle Accelerators , Radiotherapy, High-Energy/methods , Animals , Cobalt Radioisotopes , Dose-Response Relationship, Radiation , Female , Gamma Rays , Intestinal Neoplasms/radiotherapy , Male , Mice , Mice, Inbred Strains , Neutrons , Precancerous Conditions/radiotherapy , Protons , Relative Biological Effectiveness , South Africa