Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 10(1): 1527, 2020 01 30.
Article in English | MEDLINE | ID: mdl-32001782

ABSTRACT

Ventilation heterogeneity is frequent in bronchial asthma and can be assessed using multiple breath wash-out testing (MBW). Most data is available in paediatric patients and using nitrogen as a tracer gas. We aimed to evaluate sulphur hexafluoride (SF6) MBW in adult asthmatics. Spirometry, whole-body plethysmography, impulse oscillometry and SF6-MBW were prospectively performed. MBW parameters reflecting global (lung clearance index, LCI), acinar (Sacin) and conductive (Scond) ventilation heterogeneity were derived from three consecutive wash-outs. LCI was calculated for the traditional 2.5% and an earlier 5% stopping point that has the potential to reduce wash-out times. 91 asthmatics (66%) and 47 non-asthmatic controls (34%) were included in final analysis. LCI2.5 and LCI5 were higher in asthmatics (p < 0.001). Likewise, Sacin and Scond were elevated (p < 0.001 and p < 0.01). Coefficient of variation was 3.4% for LCI2.5 and 3.5% for LCI5 in asthmatics. Forty-one asthmatic patients had normal spirometry. ROC analysis revealed an AUC of 0.906 for the differentiation from non-asthmatic controls exceeding diagnostic performance of individual and conventional parameters (AUC = 0.819, p < 0.05). SF6-MBW is feasible and reproducible in adult asthmatics. Ventilation heterogeneity is increased as compared to non-asthmatic controls persisting in asthmatic patients with normal spirometry. Diagnostic performance is not affected using an earlier LCI stopping point while reducing wash-out duration considerably.


Subject(s)
Pulmonary Ventilation/physiology , Respiratory Function Tests/methods , Sulfur Hexafluoride/metabolism , Adult , Aged , Asthma/diagnosis , Asthma/metabolism , Asthma/physiopathology , Breath Tests/methods , Feasibility Studies , Female , Humans , Lung/metabolism , Male , Middle Aged , Respiration , Spirometry/methods
2.
J Clin Med ; 7(12)2018 Dec 09.
Article in English | MEDLINE | ID: mdl-30544842

ABSTRACT

Airways obstruction is frequent in patients with pulmonary hypertension (PH). Small airway disease (SAD) was identified as a major contributor to resistance and symptoms. However, it is easily missed using current diagnostic approaches. We aimed to evaluate more elaborate diagnostic tests such as impulse oscillometry (IOS) and SF6-multiple-breath-washout (MBW) for the assessment of SAD in PH. Twenty-five PH patients undergoing body-plethysmography, IOS and MBW testing were prospectively included and equally matched to pulmonary healthy and non-healthy controls. Lung clearance index (LCI) and acinar ventilation heterogeneity (Sacin) differed significantly between PH, healthy and non-healthy controls. Likewise, differences were found for all IOS parameters between PH and healthy, but not non-healthy controls. Transfer factor corrected for ventilated alveolar volume (TLCO/VA), frequency dependency of resistance (D5-20), resonance frequency (Fres) and Sacin allowed complete differentiation between PH and healthy controls (AUC (area under the curve) = 1.0). Likewise, PH patients were separated from non-healthy controls (AUC 0.762) by D5-20, LCI and conductive ventilation heterogeneity (Scond). Maximal expiratory flow (MEF) values were not associated with additional diagnostic values. MBW and IOS are feasible in PH patients both providing additional information. This can be used to discriminate PH from healthy and non-healthy controls. Therefore, further research targeting SAD in PH and evaluation of therapeutic implications is justified.

3.
BMC Pulm Med ; 17(1): 185, 2017 Dec 11.
Article in English | MEDLINE | ID: mdl-29228942

ABSTRACT

BACKGROUND: Multiple breath washout (MBW) became a valuable research tool assessing ventilation heterogeneity. However, routine clinical application still faces several challenges. Deriving MBW parameters from three technically acceptable measurements according to current recommendations prolongs test times. We therefore aimed to evaluate reporting only duplicate measurements in healthy adults and pulmonary disease. METHODS: One hundred and fifty-three subjects prospectively underwent conventional lung function testing and closed-circuit SF6-MBW. Three technically acceptable MBW-measurements were obtained in 103 subjects. RESULTS: Lung clearance index (LCI) differed significantly among 19 controls (7.4 ± 0.8), 19 patients with sarcoidosis (8.1 ± 1.2), 32 with bronchial asthma (9.2 ± 1.9) and 33 with COPD (10.8 ± 2.2, p < 0.001). Within-test repeatability was high (coefficient of variation between 2.5% in controls and 3.6% in COPD) and remained unchanged when only including the first two measurements. Likewise, LCI remained stable with mean absolute changes ranging from 0.9 ± 0.8% in controls to 1.5 ± 0.9% in COPD (p = 0.1). Mean test time reduction differed significantly between groups reaching 200 s in COPD (p = 0.01). CONCLUSIONS: Duplicate SF6-MBW-measurements are sufficient in adult patients with pulmonary disease and healthy controls. LCI values and intra-test repeatability are not affected reducing total test time statistically significant. Our findings have the potential to further facilitate application of MBW in research and clinical routine. TRIAL REGISTRATION: NCT03176745 , June 2, 2017 retrospectively registered.


Subject(s)
Asthma/diagnosis , Lung , Pulmonary Disease, Chronic Obstructive/diagnosis , Sarcoidosis, Pulmonary/diagnosis , Adult , Female , Humans , Lung/pathology , Lung/physiopathology , Male , Reproducibility of Results , Respiratory Function Tests/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...