Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
Med Phys ; 51(5): 3165-3172, 2024 May.
Article in English | MEDLINE | ID: mdl-38588484

ABSTRACT

BACKGROUND: Simulated error training is a method to practice error detection in situations where the occurrence of error is low. Such is the case for the physics plan and chart review where a physicist may check several plans before encountering a significant problem. By simulating potentially hazardous errors, physicists can become familiar with how they manifest and learn from mistakes made during a simulated plan review. PURPOSE: The purpose of this project was to develop a series of training datasets that allows medical physicists and trainees to practice plan and chart reviews in a way that is familiar and accessible, and to provide exposure to the various failure modes (FMs) encountered in clinical scenarios. METHODS: A series of training datasets have been developed that include a variety of embedded errors based on the risk-assessment performed by American Association of Physicists in Medicine (AAPM) Task Group 275 for the physics plan and chart review. The training datasets comprise documentation, screen shots, and digital content derived from common treatment planning and radiation oncology information systems and are available via the Cloud-based platform ProKnow. RESULTS: Overall, 20 datasets have been created incorporating various software systems (Mosaiq, ARIA, Eclipse, RayStation, Pinnacle) and delivery techniques. A total of 110 errors representing 50 different FMs were embedded with the 20 datasets. The project was piloted at the 2021 AAPM Annual Meeting in a workshop where participants had the opportunity to review cases and answer survey questions related to errors they detected and their perception of the project's efficacy. In general, attendees detected higher-priority FMs at a higher rate, though no correlation was found between detection rate and the detectability of the FMs. Familiarity with a given system appeared to play a role in detecting errors, specifically when related to missing information at different locations within a given software system. Overall, 96% of respondents either agreed or strongly agreed that the ProKnow portal and training datasets were effective as a training tool, and 75% of respondents agreed or strongly agreed that they planned to use the tool at their local institution. CONCLUSIONS: The datasets and digital platform provide a standardized and accessible tool for training, performance assessment, and continuing education regarding the physics plan and chart review. Work is ongoing to expand the project to include more modalities, radiation oncology treatment planning and information systems, and FMs based on emerging techniques such as auto-contouring and auto-planning.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Radiotherapy Planning, Computer-Assisted/methods , Health Physics/education , Humans , Medical Errors/prevention & control
2.
Pract Radiat Oncol ; 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38508451

ABSTRACT

PURPOSE: There have been numerous significant ransomware attacks impacting Radiation Oncology in the past 5 years. Research into ransomware attack response in Radiation Oncology has consisted of case reports and descriptive articles and has lacked quantitative studies. The purpose of this work was to identify the significant safety risks to patients being treated with radiation therapy during a ransomware attack scenario, using Failure Modes and Effects Analysis. METHODS AND MATERIALS: A multi-institutional and multidisciplinary team conducted a Failure Modes and Effects Analysis by developing process maps and using Risk Priority Number (RPN) scores to quantify the increased likelihood of incidents in a ransomware attack scenario. The situation that was simulated was a ransomware attack that had removed the capability to access the Record and Verify (R&V) system. Five situations were considered: 1) a standard treatment of a patient with and without an R&V, 2) a standard treatment of a patient for the first fraction right after the R&V capabilities are disabled, and 3) 3 situations in which a plan modification was required. RPN scores were compared with and without R&V functionality. RESULTS: The data indicate that RPN scores increased by 71% (range, 38%-96%) when R&V functionality is disabled compared with a nonransomware attack state where R&V functionality is available. The failure modes with the highest RPN in the simulated ransomware attack state included incorrectly identifying patients on treatment, incorrectly identifying where a patient is in their course of treatment, treating the incorrect patient, and incorrectly tracking delivered fractions. CONCLUSIONS: The presented study quantifies the increased risk of incidents when treating in a ransomware attack state, identifies key failure modes that should be prioritized when preparing for a ransomware attack, and provides data that can be used to guide future ransomware resiliency research.

3.
J Appl Clin Med Phys ; 24(10): e14130, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37646429

ABSTRACT

Concept inventories are multiple choice exams designed with the intention to test core concepts on specific subjects and evaluate common misconceptions. These tests serve as a useful tool in the classroom to assess value added by the instructor's educational methods and to better understand how students learn. They can provide educators with a method to evaluate their current teaching strategies and to make modifications that enhance student learning and ultimately elevate the quality of medical physics education. The use of concept inventories in introductory college physics courses revealed important gaps in conceptual understanding of physics by undergraduate students and motivated a shift of physics teaching towards more effective methods, such as active learning techniques. The goal of this review is to introduce medical physicists to concept inventories as educational evaluation tools and discuss potential applications to medical physics education by development through multi-institutional collaboration.

4.
J Appl Clin Med Phys ; 24(6): e14007, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37118926

ABSTRACT

PURPOSE: The purpose of this survey study is to compare the experiences of programs and applicants in the MedPhys Match (MPM) in the 2020-21 match cycle with experiences reported from previous match cycles. The 2020-21 match cycle was unique in that recruitment and interviewing were almost exclusively virtual during the COVID-19 pandemic. METHODS: A survey was sent to all applicants and programs registered for the 2020-21 MPM. Survey questions asked about the pre-interview screening, interview, ranking, and post-match stages of the residency match process. Survey data were analyzed using graphical methods and spreadsheet tools. RESULTS: Advantages and disadvantages to the virtual interviewing experience were reported by applicants and program directors (PDs). The advantages included reduced cost and greater scheduling flexibility with fewer scheduling conflicts, allowing applicants to consider more programs. These advantages greatly outweighed the disadvantages such as the inability to meet faculty/staff and current residents in person and gauge the feel of the program. PDs recognized the advantages of minimal costs and time savings for applicants. Programs reported it was difficult to convey workplace culture and the physical environment and to gauge personality and interpersonal skills of the applicants. CONCLUSION: The virtual interviewing environment for residency recruitment in medical physics is strongly preferred by applicants over required in-person interviews. The advantages identified by applicants outweigh the disadvantages, allowing applicants to feel confident in their ranking decisions and overall satisfied with their match results. PDs acknowledge the greater equity of access to interviews for applicants in the virtual environment, however, they are overall less satisfied with their ability to showcase their program's strengths and to assess the personality of applicants. Caution is urged when considering a hybrid interview model to ensure fair assessments that do not depend on whether an applicant chooses to accept an optional in-person interview or site visit.


Subject(s)
COVID-19 , Internship and Residency , Humans , COVID-19/epidemiology , Pandemics , Faculty , Surveys and Questionnaires
5.
J Appl Clin Med Phys ; 24(3): e13895, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36739483

ABSTRACT

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8000 members and is the principal organization of medical physicists in the US. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the US. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines: Must and must not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. While must is the term to be used in the guidelines, if an entity that adopts the guideline has shall as the preferred term, the AAPM considers that must and shall have the same meaning. Should and should not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances.


Subject(s)
Health Physics , Radiation Oncology , Humans , United States , Health Physics/education , Checklist , Societies
6.
Brachytherapy ; 21(6): 823-832, 2022.
Article in English | MEDLINE | ID: mdl-36192312

ABSTRACT

PURPOSE: We report the feasibility, experience, and early outcomes of the combined intracavitary and interstitial dedicated applicator using the Kelowna GYN template (Varian, Palo Alto, CA). METHODS AND MATERIALS: The Kelowna GYN template is CT compatible and used for the treatment of gynecologic cancers. In cases with patients that have an intact uterus, a modified applicator system using the Kelowna GYN template and a 3D printed adapter piece allows for compatibility with an intrautaerine tandem. RESULTS: We reviewed the treatment course of 23 patients comprising of 86 fractions of HDR treatment. Median D90 for cervical tumors (n = 7) was 82.4 Gy (range 77.7-92.6); for postoperative cervical tumors (n = 2) was 73.9 Gy (range 72.0-5.8); for vaginal tumors (n = 4) was 85.8 Gy (range 79.8-88.1); for recurrent endometrial (n = 10) was 86.9 Gy (range 74.8-103.2). Median EQD2 D2cc for bladder was 72.4 Gy (range 47.7-99.4), for rectum was 61.2 Gy (range 52.4-80.6), and for sigmoid colon of 50.5 Gy (44.3-66.9). At a median follow-up of 12 months, 2 patients had a local recurrence. Two patients had distant recurrence: one with carcinomatosis at 6 months, and one with pulmonary metastases at 3 months. No patients had late grade three toxicities. CONCLUSIONS: Our single institutional experience supports the use of the Kelowna template as a robust system as a combined IC-IS applicator resulting in versatile and reproducible implants for a variety of gynecologic malignancies.


Subject(s)
Brachytherapy , Genital Neoplasms, Female , Uterine Cervical Neoplasms , Female , Humans , Brachytherapy/methods , Genital Neoplasms, Female/radiotherapy , Radiotherapy Dosage , Uterine Cervical Neoplasms/radiotherapy , Uterine Cervical Neoplasms/pathology , Treatment Outcome , Radiotherapy Planning, Computer-Assisted/methods
7.
Int J Radiat Oncol Biol Phys ; 112(4): 986-995, 2022 03 15.
Article in English | MEDLINE | ID: mdl-34767934

ABSTRACT

PURPOSE: Radiation pneumonitis remains a major limitation in the radiation therapy treatment of patients with lung cancer. Functional avoidance radiation therapy uses functional imaging to reduce pulmonary toxic effects by designing radiation therapy plans that reduce doses to functional regions of the lung. Lung functional imaging has been developed that uses 4-dimensional computed tomography (4DCT) imaging to calculate 4DCT-based lung ventilation (4DCT-ventilation). A phase 2 multicenter study was initiated to evaluate 4DCT-ventilation functional avoidance radiation therapy. The study hypothesis was that functional avoidance radiation therapy could reduce the rate of grade ≥2 radiation pneumonitis to 12% compared with a 25% historical rate, with the trial being positive if ≤16.4% of patients experienced grade ≥2 pneumonitis. METHODS AND MATERIALS: Lung cancer patients receiving curative-intent radiation therapy (prescription doses of 45-75 Gy) and chemotherapy were accrued. Patient 4DCT scans were used to generate 4DCT-ventilation images. The 4DCT-ventilation images were used to generate functional avoidance plans that reduced doses to functional portions of the lung while delivering the prescribed tumor dose. Pneumonitis was evaluated by a clinician at 3, 6, and 12 months after radiation therapy. RESULTS: Sixty-seven evaluable patients were accrued between April 2015 and December 2019. The median prescription dose was 60 Gy (range, 45-66 Gy) delivered in 30 fractions (range, 15-33 fractions). The average reduction in the functional volume of lung receiving ≥20 Gy with functional avoidance was 3.5% (range, 0%-12.8%). The median follow-up was 312 days. The rate of grade ≥2 radiation pneumonitis was 10 of 67 patients (14.9%; 95% upper CI, 24.0%), meeting the phase 2 criteria. CONCLUSIONS: 4DCT-ventilation offers an imaging modality that is convenient and provides functional imaging without an extra procedure necessary. This first report of a multicenter study of 4DCT-ventilation functional avoidance radiation therapy provided data showing that the trial met phase 2 criteria and that evaluation in a phase 3 study is warranted.


Subject(s)
Lung Neoplasms , Radiation Pneumonitis , Four-Dimensional Computed Tomography/methods , Humans , Lung/pathology , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Lung Neoplasms/radiotherapy , Pulmonary Ventilation/radiation effects , Radiation Pneumonitis/etiology , Radiation Pneumonitis/prevention & control , Radiotherapy Planning, Computer-Assisted/methods
8.
Cureus ; 14(12): e33100, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36721584

ABSTRACT

The purpose of this report is to present the implementation of a process for after-hours radiation treatment (RT) utilizing remote treatment planning based on optimized diagnostic computed tomography (CT) scans for the urgent palliative treatment of inpatients. A standardized operating procedure was developed by an interprofessional panel to improve the quality of after-hours RT and minimize the risk of treatment errors. A new diagnostic CT protocol was created that could be performed after-hours on hospital scanners and would ensure a reproducible patient position and adequate field of view. An on-call structure for dosimetry staff was created utilizing remote treatment planning. The optimized CT protocol was developed in collaboration with the radiology department, and a novel order set was created in the electronic health system. The clinical workflow begins with the radiation oncologist notifying the on-call team (therapist, dosimetrist, and physicist) and obtaining an optimized diagnostic CT scan on a hospital-based scanner. The dosimetrist remotely creates a plan; the physicist checks the plan; and the patient is treated. Plans are intentionally simple (parallel opposed fields, symmetric jaws) to expedite care and reduce the risk of error. Education on the new process was provided for all relevant staff. Our process was successfully implemented with the use of an optimized CT protocol and remote treatment planning. This approach has the potential to improve the quality and safety of emergent after-hours RT by better approximating the normal process of care.

9.
Med Phys ; 47(10): 5061-5069, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32562501

ABSTRACT

PURPOSE: Automatic detection and identification of setup devices, using a deep convolutional neural network (CNN) for real-time multiclass object detection, has the potential to reduce errors in the treatment delivery process by avoiding documentation errors. METHODS: A database of the setup device photos from the most recent 1200 patients treated at our institution was downloaded from the record and verify (R&V) system along with the corresponding setup notes. Images were manually labeled with bounding boxes of each device. A real-time object detection CNN using the "you only look once" (YOLOv2) architecture was trained using transfer learning of a pretrained CNN (ResNet50). The CNN was trained to detect and identify 11 of the most common treatment accessories used at our institution. RESULTS: Using transfer learning of a CNN for multiclass object detection, we are able to automatically detect and identify setup devices in photographs with an accuracy of 96%. CONCLUSIONS: Automation in radiation oncology has the potential to reduce risk. Automatic detection of setup devices is possible using a CNN and transfer learning. This work shows both the value of incident learning systems (ILS) in practice knowledge dissemination, and shows how automation of clinical processes and less reliance on manual documentation has the potential for risk reduction in radiation oncology treatments.


Subject(s)
Deep Learning , Automation , Humans , Neural Networks, Computer , Patient Positioning
10.
J Appl Clin Med Phys ; 21(7): 100-106, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32426947

ABSTRACT

PURPOSE: To identify causes of error, and present the concept of an automated technique that improves efficiency and helps to reduce transcription and manual data entry errors in the treatment planning of total body irradiation (TBI). METHODS: Analysis of incidents submitted to incident learning system (ILS) was performed to identify potential avenues for improvement by implementation of automation of the manual treatment planning process for total body irradiation (TBI). Following this analysis, it became obvious that while the individual components of the TBI treatment planning process were well implemented, the manual 'bridging' of the components (transcribing data, manual data entry etc.) were leading to high potential for error. A C#-based plug-in treatment planning script was developed to remove the manual parts of the treatment planning workflow that were contributing to increased risk. RESULTS: Here we present an example of the implementation of "Glue" programming, combining treatment planning C# scripts with existing spreadsheet calculation worksheets. Prior to the implementation of automation, 35 incident reports related to the TBI treatment process were submitted to the ILS over a 6-year period, with an average of 1.4 ± 1.7 reports submitted per quarter. While no incidents reached patients, reports ranged from minor documentation issues to potential for mistreatment if not caught before delivery. Since the implementation of automated treatment planning and documentation, treatment planning time per patient, including documentation, has been reduced; from an average of 45 min pre-automation to <20 min post-automation. CONCLUSIONS: Manual treatment planning techniques may be well validated, but they are time-intensive and have potential for error. Often the barrier to automating these techniques becomes the time required to "re-code" existing solutions in unfamiliar computer languages. We present the workflow here as a proof of concept that automation may help to improve clinical efficiency and safety for special procedures.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Whole-Body Irradiation , Automation , Humans , Risk Management , Workflow
11.
Pract Radiat Oncol ; 10(3): e166-e172, 2020.
Article in English | MEDLINE | ID: mdl-31526898

ABSTRACT

PURPOSE: This study aimed to identify the current state of residency training in physics plan reviews. METHODS AND MATERIALS: A voluntary, anonymous survey was sent to all program directors of accredited therapeutic medical physics residency programs in North America. Survey questions were developed to determine whether and how residents are trained in physics plan reviews. Survey questions were developed using expert validation and cognitive pretesting. RESULTS: Using a prospectively approved study (COMIRB 18-1073), responses were collected from 70 program directors, representing a 70% response rate. All respondents (100%) designated patient safety to be the purpose of physics plan reviews. Of the respondents, 94% indicated that physicists should first receive training in physics plan reviews while in a residency program. The vast majority of respondents (99%) provide training to residents in physics plan reviews. Although 57 programs (81% of respondents) have residents perform physics plan reviews as part of clinical practice (with varying levels of independence), 13 programs (19% of respondents) do not. The majority of respondents use the following training methods: observe staff physicists (96%), perform supervised reviews on actual patients for training or clinical practice (93%), use a checklist (80%), and read reference materials (62%). Although simulation plans with embedded errors would be implemented by 71% of respondents, they are currently used in only 19% of programs. CONCLUSIONS: The present study is the first to characterize chart-check teaching practices in medical physics residency programs. The vast majority of programs currently train residents in physics plan reviews. The most common teaching methods are observing and performing physics plan reviews, but there is variability in the level of resident involvement in clinical practice for physics plan reviews. There is room for the field to consider advancing current training methods, which is especially important given the critical roles that physics plan reviews have with regard to patient safety.


Subject(s)
Internship and Residency/organization & administration , Physics/education , Humans , Internet , North America , Prospective Studies , Surveys and Questionnaires
13.
Int J Radiat Oncol Biol Phys ; 102(4): 1357-1365, 2018 11 15.
Article in English | MEDLINE | ID: mdl-30353873

ABSTRACT

PURPOSE: Functional imaging has been proposed that uses 4DCT images to calculate 4DCT-based lung ventilation (4DCT-ventilation). We have started a 2-institution, phase 2 prospective trial evaluating the feasibility, safety, and preliminary efficacy of 4DCT-ventilation functional avoidance. The trial hypothesis is that the rate of grade ≥2 radiation pneumonitis could be reduced to 12% with functional avoidance, compared with a 25% rate of pneumonitis with a historical control. The trial employed a Simon 2-stage design with a planned futility analysis after 17 evaluable patients. The purpose of this work is to present the trial design and implementation, dosimetric data, and clinical results for the planned futility analysis. METHODS AND MATERIALS: Eligible patients were patients with lung cancer who were prescribed doses of 45 to 75 Gy. For each patient, the 4DCT data were used to generate a 4DCT-ventilation image using the Hounsfield unit technique along with a compressible flow-based image registration algorithm. Two intensity modulated radiation therapy treatment plans were generated: (1) a standard lung plan and (2) a functional avoidance treatment plan that aimed to reduce dose to functional lung while meeting target and normal tissue constraints. Patients were treated with the functional avoidance plan and evaluated for thoracic toxicity (presented as rate and 95% confidence intervals [CI]) with a 1-year follow-up. RESULTS: The V20 to functional lung was 21.6% ± 9.5% (mean ± standard deviation) with functional avoidance, representing a decrease of 3.2% (P < .01) relative to standard, nonfunctional treatment plans. The rates of grade ≥2 and grade ≥3 radiation pneumonitis were 17.6% (95% CI, 3.8%-43.4%) and 5.9% (95% CI, 0.1%-28.7%), respectively. CONCLUSIONS: Dosimetrically, functional avoidance achieved reduction in doses to functional lung while meeting target and organ at risk constraints. On the basis of Simon's 2-stage design and the 17.6% grade ≥2 pneumonitis rate, the trial met its futility criteria and has continued accrual.


Subject(s)
Four-Dimensional Computed Tomography/methods , Lung Neoplasms/radiotherapy , Radiation Pneumonitis/epidemiology , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated/adverse effects , Female , Humans , Male , Prospective Studies , Pulmonary Ventilation , Radiotherapy Dosage , Research Design
14.
J Appl Clin Med Phys ; 19(6): 298-305, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30225861

ABSTRACT

PURPOSE: The purpose of this work is to describe our experience launching an expanded incident learning system for patient safety and quality that takes into account aspects beyond therapeutic dose delivery, specifically imaging/simulation incidents, medical care incidents, and operational issues. METHODS: Our ILS was designed for a newly created health system comprised of a midsized academic hospital and two smaller community hospitals. The main design goal was to create a highly sensitive system to capture as much information throughout the department as possible. Reports were classified according to incidents and near misses involving therapeutic radiation, imaging/simulation, and patient care (not involving radiation), unsafe conditions, operational issues, and accolades/suggestions. Reports were analyzed according to impact on various steps in the process of care. Actions made in response to reports were assessed and characterized by intervention reliability. RESULTS: A total of 1125 reports were submitted in the first 23 months. For all three departments, therapeutic radiation incidents and near misses consisted of less than one-third of all reports submitted. For the midsized academic department, operational issues and unsafe conditions comprised the largest percentage of reports (70%). Although the majority of reports impacted steps related to the technical aspects of treatment (simulation, planning, and treatment delivery), 20% impacted other steps such as scheduling or clinic visits. More than 160 actions were performed in response to reports. Of these actions, 63 were quality improvement interventions to improve practices, while 97 were learning actions for raising awareness. CONCLUSIONS: We have developed an ILS that identifies issues related to the entire process of care delivery in radiation oncology, as evidenced by frequent and varied reported events. By identifying a broad spectrum of issues in a department, opportunities for improvement can be identified.


Subject(s)
Health Plan Implementation , Hospitals/standards , Medical Errors/prevention & control , Near Miss, Healthcare/legislation & jurisprudence , Patient Safety , Risk Management , Safety Management , Humans , Near Miss, Healthcare/organization & administration , Near Miss, Healthcare/statistics & numerical data , Quality Improvement
15.
Radiother Oncol ; 129(3): 494-498, 2018 12.
Article in English | MEDLINE | ID: mdl-29628292

ABSTRACT

BACKGROUND AND PURPOSE: There are two significant challenges when implementing functional-guided radiotherapy using 4DCT-ventilation imaging: (1) lack of knowledge of realistic patient specific dosimetric goals for functional lung and (2) ensuring consistent plan quality across multiple planners. Knowledge-based planning (KBP) is positioned to address both concerns. MATERIAL AND METHODS: A KBP model was created from 30 previously planned functional-guided lung patients. Standard organs at risk (OAR) in lung radiotherapy and a ventilation contour delineating areas of high ventilation were included. Model validation compared dose-metrics to standard OARs and functional dose-metrics from 20 independent cases that were planned with and without KBP. RESULTS: A significant improvement was observed for KBP optimized plans in V20Gy and mean dose to functional lung (p = 0.005 and 0.001, respectively), V20Gy and mean dose to total lung minus GTV (p = 0.002 and 0.01, respectively), and mean doses to esophagus (p = 0.005). CONCLUSION: The current work developed a KBP model for functional-guided radiotherapy. Modest, but statistically significant, improvements were observed in functional lung and total lung doses.


Subject(s)
Knowledge Bases , Lung Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Four-Dimensional Computed Tomography , Humans , Organs at Risk , Radiotherapy Dosage , Respiration
16.
J Appl Clin Med Phys ; 18(3): 144-152, 2017 May.
Article in English | MEDLINE | ID: mdl-28436107

ABSTRACT

INTRODUCTION: 4DCT-ventilation is an exciting new imaging modality that uses 4DCT data to calculate lung-function maps. Because 4DCTs are acquired as standard of care for lung cancer patients undergoing radiotherapy, 4DCT-ventiltation provides functional information at no extra dosimetric or monetary cost to the patient. The development of clinical trials is underway to use 4DCT-ventilation imaging to spare functional lung in patients undergoing radiotherapy. The purpose of this work was to perform a virtual trial using retrospective data to develop the practical aspects of a 4DCT-ventilation functional avoidance clinical trial. METHODS: The study included 96 stage III lung cancer patients. A 4DCT-ventilation map was calculated using the patient's 4DCT-imaging, deformable registration, and a density-change-based algorithm. Clinical trial inclusion assessment used quantitative and qualitative metrics based on the patient's spatial ventilation profile. Clinical and functional plans were generated for 25 patients. The functional plan aimed to reduce dose to functional lung while meeting standard target and critical structure constraints. Standard and dose-function metrics were compared between the clinical and functional plans. RESULTS: Our data showed that 69% and 59% of stage III patients have regional variability in function based on qualitative and quantitative metrics, respectively. Functional planning demonstrated an average reduction of 2.8 Gy (maximum 8.2 Gy) in the mean dose to functional lung. CONCLUSIONS: Our work demonstrated that 60-70% of stage III patients would be eligible for functional planning and that a typical functional lung mean dose reduction of 2.8 Gy can be expected relative to standard clinical plans. These findings provide salient data for the development of functional clinical trials.


Subject(s)
Clinical Trials as Topic , Four-Dimensional Computed Tomography , Lung Neoplasms/physiopathology , Pulmonary Ventilation , Algorithms , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Lung Neoplasms/radiotherapy , Prospective Studies , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Conformal , Respiration , Retrospective Studies
17.
Med Phys ; 44(1): 200-208, 2017 Jan.
Article in English | MEDLINE | ID: mdl-28102961

ABSTRACT

PURPOSE: A primary treatment option for lung cancer patients is surgical resection. Patients who have poor lung function prior to surgery are at increased risk of developing serious and life-threatening complications after surgical resection. Surgeons use nuclear medicine ventilation-perfusion (VQ) scans along with pulmonary function test (PFT) information to assess a patient's pre-surgical lung function. The nuclear medicine images and pre-surgery PFTs are used to calculate percent predicted postoperative (%PPO) PFT values by estimating the amount of functioning lung tissue that would be lost with surgical resection. Nuclear medicine imaging is currently considered the standard of care when evaluating the amount of ventilation that would be lost due to surgery. A novel lung function imaging modality has been developed in radiation oncology that uses 4-Dimensional computed tomography data to calculate ventilation maps (4DCT-ventilation). Compared to nuclear medicine, 4DCT-ventilation is cheaper, does not require a radioactive contrast agent, provides a faster imaging procedure, and has improved spatial resolution. In this work we perform a retrospective study to assess the use of 4DCT-ventilation as a pre-operative surgical lung function evaluation tool. Specifically, the purpose of our study was to compare %PPO PFT values calculated with 4DCT-ventilation and %PPO PFT values calculated with nuclear medicine ventilation-perfusion imaging. METHODS: The study included 16 lung cancer patients that had undergone 4DCT imaging, nuclear medicine imaging, and had Forced Expiratory Volume in 1 second (FEV1 ) acquired as part of a standard PFT. The 4DCT datasets, spatial registration, and a density-change-based model were used to compute 4DCT-ventilation maps. Both 4DCT-ventilation and nuclear medicine images were used to calculate %PPO FEV1 . The %PPO FEV1 was calculated by scaling the pre-surgical FEV1 by (1-fraction of total resected ventilation); where the resected ventilation was determined using either the 4DCT-ventilation or nuclear medicine imaging. Calculations were done assuming both lobectomy and pneumonectomy resections. The %PPO FEV1 values were compared between the 4DCT-ventilation-based calculations and the nuclear medicine-based calculations using correlation coefficients, average differences, and Receiver Operating Characteristic (ROC) analysis. RESULTS: Overall the 4DCT-ventilation derived %PPO FEV1 values agreed well with nuclear medicine-derived %PPO FEV1 data with correlations of 0.99 and 0.81 for lobectomy and pneumonectomy, respectively. The average differences between the 4DCT-ventilation and nuclear medicine-based calculation for %PPO FEV1 were less than 5%. ROC analysis revealed predictive accuracy that ranged from 87.5% to 100% when assessing the ability of 4DCT-ventilation to predict for nuclear medicine-based %PPO FEV1 values. CONCLUSIONS: 4DCT-ventilation is an innovative technology developed in radiation oncology that has great potential to translate to the surgical domain. The high correlation results when comparing 4DCT-ventilation to the current standard of care provide a strong rationale for a prospective clinical trial assessing 4DCT-ventilation in the clinical setting. 4DCT-ventilation can reduce the cost and imaging time for patients while providing improved spatial accuracy and quantitative results for surgeons.


Subject(s)
Four-Dimensional Computed Tomography , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/physiopathology , Pulmonary Ventilation , Respiratory Function Tests , Aged , Aged, 80 and over , Female , Humans , Lung Neoplasms/surgery , Male , Middle Aged , Preoperative Period , Retrospective Studies
18.
Int J Radiat Oncol Biol Phys ; 95(4): 1273-80, 2016 07 15.
Article in English | MEDLINE | ID: mdl-27354134

ABSTRACT

PURPOSE: The development of clinical trials is underway to use 4-dimensional computed tomography (4DCT) ventilation imaging to preferentially spare functional lung in patients undergoing radiation therapy. The purpose of this work was to generate data to aide with clinical trial design by retrospectively characterizing dosimetric and functional profiles for patients with different stages of lung cancer. METHODS AND MATERIALS: A total of 118 lung cancer patients (36% stage I and 64% stage III) from 2 institutions were used for the study. A 4DCT-ventilation map was calculated using the patient's 4DCT imaging, deformable image registration, and a density-change-based algorithm. To assess each patient's spatial ventilation profile both quantitative and qualitative metrics were developed, including an observer-based defect observation and metrics based on the ventilation in each lung third. For each patient we used the clinical doses to calculate functionally weighted mean lung doses and metrics that assessed the interplay between the spatial location of the dose and high-functioning lung. RESULTS: Both qualitative and quantitative metrics revealed a significant difference in functional profiles between the 2 stage groups (P<.01). We determined that 65% of stage III and 28% of stage I patients had ventilation defects. Average functionally weighted mean lung dose was 19.6 Gy and 5.4 Gy for stage III and I patients, respectively, with both groups containing patients with large spatial overlap between dose and high-function regions. CONCLUSION: Our 118-patient retrospective study found that 65% of stage III patients have regionally variant ventilation profiles that are suitable for functional avoidance. Our results suggest that regardless of disease stage, it is possible to have unique spatial interplay between dose and high-functional lung, highlighting the importance of evaluating the function of each patient and developing a personalized functional avoidance treatment approach.


Subject(s)
Lung Neoplasms/radiotherapy , Lung/physiopathology , Four-Dimensional Computed Tomography , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Lung Neoplasms/physiopathology , Neoplasm Staging , Radiotherapy Dosage , Retrospective Studies
19.
Pract Radiat Oncol ; 6(1): 34-43, 2016.
Article in English | MEDLINE | ID: mdl-26577008

ABSTRACT

PURPOSE: High-dose-rate (HDR) brachytherapy is a high-risk procedure with serious errors reported in the medical literature. Our goal was to develop a quality improvement framework for HDR brachytherapy using a multidisciplinary approach. This work describes the time, personnel, and materials involved in implementation as well as staff-reported safety benefits of quality improvement checklists. METHODS AND MATERIALS: Quality improvement was achieved using a department-wide multidisciplinary approach. Process mapping of the entire HDR program, from initial scheduling through follow-up, was performed. The scope of the project was narrowed to the point of treatment delivery. Two types of multidisciplinary checklists were created: a safety-timeout checklist to ensure safety-critical actions were performed before treatment initiation; and detailed procedure checklists that served as written procedures for physicians, physicists, dosimetrists, and nurses. Implementation was carried out through initial training led by various staff members, creation of visual training guides, piloting and use of checklists for all treatments, and auditing of checklist compliance. RESULTS: Process maps of the entire HDR program were generated and used to guide subsequent changes in the treatment delivery process. A single safety-timeout checklist and the individual procedure checklists were created and used at the time of treatment delivery. The 3-month audit showed that the safety-timeout checklist was used for 100% of treatment fractions. Individual procedure checklists were used for 85% of fractions. All cross-covering physicians and physicists continued to use these checklists 100% of the time. Staff survey results indicated improvements in safety and increased benefits for cross-covering staff. CONCLUSIONS: In using a multidisciplinary approach to quality improvement, process mapping and comprehensive checklists for HDR treatment delivery have been implemented. This has resulted in improved practices that are optimal in our department. This experience can provide others with practical strategies toward implementing such changes in their own facilities.


Subject(s)
Health Plan Implementation , Medical Errors/prevention & control , Neoplasms/radiotherapy , Quality Assurance, Health Care , Radiation Oncology/standards , Radiotherapy Planning, Computer-Assisted/methods , Checklist , Humans , Patient Safety , Quality Control , Radiation Oncology/statistics & numerical data , Radiotherapy Dosage , Radiotherapy Setup Errors/prevention & control
20.
Int J Radiat Oncol Biol Phys ; 92(2): 423-9, 2015 Jun 01.
Article in English | MEDLINE | ID: mdl-25817531

ABSTRACT

PURPOSE: A new form of functional imaging has been proposed in the form of 4-dimensional computed tomography (4DCT) ventilation. Because 4DCTs are acquired as part of routine care for lung cancer patients, calculating ventilation maps from 4DCTs provides spatial lung function information without added dosimetric or monetary cost to the patient. Before 4DCT-ventilation is implemented it needs to be clinically validated. Pulmonary function tests (PFTs) provide a clinically established way of evaluating lung function. The purpose of our work was to perform a clinical validation by comparing 4DCT-ventilation metrics with PFT data. METHODS AND MATERIALS: Ninety-eight lung cancer patients with pretreatment 4DCT and PFT data were included in the study. Pulmonary function test metrics used to diagnose obstructive lung disease were recorded: forced expiratory volume in 1 second (FEV1) and FEV1/forced vital capacity. Four-dimensional CT data sets and spatial registration were used to compute 4DCT-ventilation images using a density change-based and a Jacobian-based model. The ventilation maps were reduced to single metrics intended to reflect the degree of ventilation obstruction. Specifically, we computed the coefficient of variation (SD/mean), ventilation V20 (volume of lung ≤20% ventilation), and correlated the ventilation metrics with PFT data. Regression analysis was used to determine whether 4DCT ventilation data could predict for normal versus abnormal lung function using PFT thresholds. RESULTS: Correlation coefficients comparing 4DCT-ventilation with PFT data ranged from 0.63 to 0.72, with the best agreement between FEV1 and coefficient of variation. Four-dimensional CT ventilation metrics were able to significantly delineate between clinically normal versus abnormal PFT results. CONCLUSIONS: Validation of 4DCT ventilation with clinically relevant metrics is essential. We demonstrate good global agreement between PFTs and 4DCT-ventilation, indicating that 4DCT-ventilation provides a reliable assessment of lung function. Four-dimensional CT ventilation enables exciting opportunities to assess lung function and create functional avoidance radiation therapy plans. The present work provides supporting evidence for the integration of 4DCT-ventilation into clinical trials.


Subject(s)
Four-Dimensional Computed Tomography , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/physiopathology , Pulmonary Disease, Chronic Obstructive/diagnostic imaging , Pulmonary Disease, Chronic Obstructive/physiopathology , Respiratory Function Tests , Adult , Aged , Aged, 80 and over , Female , Forced Expiratory Volume , Humans , Male , Middle Aged , Regression Analysis , Vital Capacity
SELECTION OF CITATIONS
SEARCH DETAIL
...