Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chem ; 73(3): 434-8, 2001 Feb 01.
Article in English | MEDLINE | ID: mdl-11217742

ABSTRACT

We present a new MALD1 sample preparation technique for peptide analysis using the matrix alpha-cyano-4-hydroxy-cinnamic acid (CHCA) and prestructured sample supports. The preparation integrates sample purification, based on the affinity of microcrystalline CHCA for peptides, thereby simplifying the analysis of crude peptide mixtures. Enzymatic digests can thus be prepared directly, without preceding purification. Prepared samples are homogeneous, facilitating automatic spectra acquisition. This method allows preparation of large numbers of samples with little effort and without the need for automation. These features make the described preparation suitable for cost-efficient high-throughput protein identification. Performance of the sample preparation is demonstrated with in situ proteolytic digests of human brain proteins separated by two-dimensional gel electrophoresis.


Subject(s)
Coumaric Acids/chemistry , Peptides/analysis , Proteome , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Brain Chemistry , Humans
2.
Anal Chem ; 72(15): 3436-42, 2000 Aug 01.
Article in English | MEDLINE | ID: mdl-10952524

ABSTRACT

Prestructured MALDI-MS sample supports have been developed that simplify high-throughput analysis of biomolecules and improve the detection sensitivity. The mass spectrometric sample support is coated with a thin layer of hydrophobic Teflon that carries an array of 200-microm gold spots, which provide hydrophilic sample anchors. Each transferred sample droplet contacts one anchor, on top of which, after solvent evaporation, the sample is exclusively deposited due to the strongly water repellent nature of the Teflon surface. The initial matrix concentration is kept low, enabling sample up-concentration by more than 2 orders of magnitudes before crystallization commences. As a result, the detection sensitivity is improved as documented by mass spectra recorded from 100 amol of various peptides, 1 fmol of a DNA 20 mer, and 5 fmol of a 130 bp PCR product. Size and spacing of the hydrophilic anchors are optimized for MALDI-MS performance (sample spot size approximately = laser irradiation spot size), for short analysis times (predetermined sample coordinates), and for high throughput sample preparation (sample anchor array according to the 1536 microtiter plate format).


Subject(s)
DNA/analysis , Peptides/analysis , Humans , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...