J Tissue Eng Regen Med ; 11(7): 2081-2089, 2017 07.
Article in English | MEDLINE | ID: mdl-26648044

ABSTRACT

The properties of osteoblasts (OBs) isolated from the axial skeleton (tOBs) differ from OBs of the orofacial skeleton (mOBs) due to the different embryological origins of the bones. The aim of the study was to assess and compare the regenerative potential of allogenic bone marrow-derived mesenchymal progenitor cells with allogenic tOBs and allogenic mOBs in combination with a mPCL-TCP scaffold in critical-sized segmental bone defects in sheep tibiae. After 6 months, the tibiae were explanted and underwent biomechanical testing, micro-computed tomography (microCT) and histological and immunohistochemical analyses. Allogenic MPCs demonstrated a trend towards a better outcome in biomechanical testing and the mean values of newly formed bone. Biomechanical, microCT and histological analysis showed no significant differences in the bone regeneration potential of tOBs and mOBs in our in vitro study, as well as in the bone regeneration potential of different cell types in vivo. Copyright © 2015 John Wiley & Sons, Ltd.


Subject(s)
Bone Regeneration , Mesenchymal Stem Cell Transplantation , Mesenchymal Stem Cells/metabolism , Osteoblasts , Tibia/injuries , Tibia/metabolism , Tissue Scaffolds , Allografts , Animals , Osteoblasts/metabolism , Osteoblasts/transplantation , Osteogenesis , Sheep , Tibia/diagnostic imaging , Tissue Engineering/methods , X-Ray Microtomography
2.
Med Eng Phys ; 37(4): 367-74, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25666401

ABSTRACT

Intramedullary nailing is the standard fixation method for displaced diaphyseal fractures of tibia. Selection of the correct nail insertion point is important for axial alignment of bone fragments and to avoid iatrogenic fractures. However, the standard entry point (SEP) may not always optimise the bone-nail fit due to geometric variations of bones. This study aimed to investigate the optimal entry for a given bone-nail pair using the fit quantification software tool previously developed by the authors. The misfit was quantified for 20 bones with two nail designs (ETN and ETN-Proximal Bend) related to the SEP and 5 entry points which were 5 mm and 10 mm away from the SEP. The SEP was the optimal entry point for 50% of the bones used. For the remaining bones, the optimal entry point was located 5 mm away from the SEP, which improved the overall fit by 40% on average. However, entry points 10 mm away from the SEP doubled the misfit. The optimised bone-nail fit can be achieved through the SEP and within the range of a 5 mm radius, except posteriorly. The study results suggest that the optimal entry point should be selected by considering the fit during insertion and not only at the final position.


Subject(s)
Bone Nails , Tibia/anatomy & histology , Tibia/surgery , Adult , Aged , Female , History, Ancient , Humans , Imaging, Three-Dimensional , Middle Aged , Models, Biological , Pattern Recognition, Automated/methods , Prosthesis Design , Software , Tibia/diagnostic imaging , Tomography, X-Ray Computed
3.
Acta Biomater ; 9(8): 7874-84, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23628773

ABSTRACT

Mesenchymal progenitor cells (MPCs) represent an attractive cell population for bone tissue engineering. Their special immunological characteristics suggest that MPCs may be used in allogenic applications. The objective of this study was to compare the regenerative potential of autologous vs. allogenic MPCs in an ovine critical size segmental defect model. Ovine MPCs were isolated from bone marrow aspirates, expanded and cultured with osteogenic medium for 2weeks before implantation. Autologous and allogenic transplantation was performed using the cell-seeded scaffolds and unloaded scaffolds, while the application of autologous bone grafts served as a control group (n=6). Bone healing was assessed 12weeks after surgery by radiology, microcomputed tomography, biomechanical testing and histology. Radiology, biomechanical testing and histology revealed no significant differences in bone formation between the autologous and allogenic groups. Both cell groups showed more bone formation than the scaffold alone, whereas the biomechanical data showed no significant differences between the cell groups and the unloaded scaffolds. The results of the study suggest that scaffold-based bone tissue engineering using allogenic cells offers the potential for an off-the-shelf product. Thus the results of this study serve as an important baseline for translation of the assessed concepts into clinical applications.


Subject(s)
Disease Models, Animal , Mesenchymal Stem Cell Transplantation/methods , Plastic Surgery Procedures/methods , Tibial Fractures/pathology , Tibial Fractures/surgery , Tissue Scaffolds , Animals , Cells, Cultured , Equipment Design , Equipment Failure Analysis , Humans , Sheep , Transplantation, Autologous/methods , Transplantation, Homologous , Treatment Outcome
4.
Med Hypotheses ; 81(2): 225-7, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23688741

ABSTRACT

The mechanical conditions in the repair tissues are known to influence the outcome of fracture healing. These mechanical conditions are determined by the stiffness of fixation and limb loading. Experimental studies have shown that there is a range of beneficial fixation stiffness for timely healing and that fixation stiffness that is either too flexible or too stiff impairs callus healing. However, much less is known about how mechanical conditions influence the biological processes that make up the sequence of bone repair and if indeed mechanical stimulation is required at all stages of repair. Secondary bone healing occurs through a sequence of events broadly characterised by inflammation, proliferation, consolidation and remodelling. It is our hypothesis that a change in fixation stiffness from very flexible to stiff can shorten the time to healing relative to constant fixation stiffness. Flexible fixation has the benefit of promoting greater callus formation and needs to be applied during the proliferative stage of repair. The greater callus size helps to stabilize the fragments earlier allowing mineralization to occur faster. Together with stable/rigid fixation applied during the latter stage of repair to ensure mineralization of the callus. The predicted benefits of inverse dynamization are shortened healing in comparison to very flexible fixation and healing time comparable or faster than stable fixation with greater callus stiffness.


Subject(s)
Fracture Healing , Humans
5.
Comput Biol Med ; 42(10): 957-63, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22901677

ABSTRACT

The finite element (FE) analysis is an effective method to study the strength and predict the fracture risk of endodontically-treated teeth. This paper presents a rapid method developed to generate a comprehensive tooth FE model using data retrieved from micro-computed tomography (µCT). With this method, the inhomogeneity of material properties of teeth was included into the model without dividing the tooth model into different regions. The material properties of the tooth were assumed to be related to the mineral density. The fracture risk at different tooth portions was assessed for root canal treatments. The micro-CT images of a tooth were processed by a Matlab software programme and the CT numbers were retrieved. The tooth contours were obtained with thresholding segmentation using Amira. The inner and outer surfaces of the tooth were imported into Solidworks and a three-dimensional (3D) tooth model was constructed. An assembly of the tooth model with the periodontal ligament (PDL) layer and surrounding bone was imported into ABAQUS. The material properties of the tooth were calculated from the retrieved CT numbers via ABAQUS user's subroutines. Three root canal geometries (original and two enlargements) were investigated. The proposed method in this study can generate detailed 3D finite element models of a tooth with different root canal enlargements and filling materials, and would be very useful for the assessment of the fracture risk at different tooth portions after root canal treatments.


Subject(s)
Image Processing, Computer-Assisted/methods , Models, Dental , Tooth Fractures/pathology , X-Ray Microtomography/methods , Databases, Factual , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/physiology , Elastic Modulus , Finite Element Analysis , Humans , Molar/diagnostic imaging , Molar/physiology , Risk Assessment , Stress, Mechanical , Tooth Fractures/diagnostic imaging , Tooth Root/diagnostic imaging , Tooth Root/physiology , Tooth, Nonvital
6.
Orthopade ; 41(4): 280-7, 2012 Apr.
Article in German | MEDLINE | ID: mdl-22476418

ABSTRACT

Well-established therapies for bone defects are restricted to bone grafts which face significant disadvantages (limited availability, donor site morbidity, insufficient integration). Therefore, the objective was to develop an alternative approach investigating the regenerative potential of medical grade polycaprolactone-tricalcium phosphate (mPCL-TCP) and silk-hydroxyapatite (silk-HA) scaffolds.Critical sized ovine tibial defects were created and stabilized. Defects were left untreated, reconstructed with autologous bone grafts (ABG) and mPCL-TCP or silk-HA scaffolds. Animals were observed for 12 weeks. X-ray analysis, torsion testing and quantitative computed tomography (CT) analyses were performed. Radiological analysis confirmed the critical nature of the defects. Full defect bridging occurred in the autograft and partial bridging in the mPCL-TCP group. Only little bone formation was observed with silk-HA scaffolds. Biomechanical testing revealed a higher torsional moment/stiffness (p < 0.05) and CT analysis a significantly higher amount of bone formation for the ABG group when compared to the silk-HA group. No significant difference was determined between the ABG and mPCL-TCP groups. The results of this study suggest that mPCL-TCP scaffolds combined can serve as an alternative to autologous bone grafting in long bone defect regeneration. The combination of mPCL-TCP with osteogenic cells or growth factors represents an attractive means to further enhance bone formation.


Subject(s)
Bone Substitutes/therapeutic use , Guided Tissue Regeneration/instrumentation , Osteogenesis/physiology , Tibial Fractures/surgery , Tissue Scaffolds , Animals , Equipment Failure Analysis , Prosthesis Design , Sheep , Treatment Outcome
7.
Injury ; 41 Suppl 1: S14-5, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20621829

ABSTRACT

The collaboration of clinicians with basic science researchers is crucial for addressing clinically relevant research questions. In order to initiate such mutually beneficial relationships, we propose a model where early career clinicians spend a designated time embedded in established basic science research groups, in order to pursue a postgraduate qualification. During this time, clinicians become integral members of the research team, fostering long term relationships and opening up opportunities for continuing collaboration. However, for these collaborations to be successful there are pitfalls to be avoided. Limited time and funding can lead to attempts to answer clinical challenges with highly complex research projects characterised by a large number of "clinical" factors being introduced in the hope that the research outcomes will be more clinically relevant. As a result, the complexity of such studies and variability of its outcomes may lead to difficulties in drawing scientifically justified and clinically useful conclusions. Consequently, we stress that it is the basic science researcher and the clinician's obligation to be mindful of the limitations and challenges of such multi-factorial research projects. A systematic step-by-step approach to address clinical research questions with limited, but highly targeted and well defined research projects provides the solid foundation which may lead to the development of a longer term research program for addressing more challenging clinical problems. Ultimately, we believe that it is such models, encouraging the vital collaboration between clinicians and researchers for the work on targeted, well defined research projects, which will result in answers to the important clinical challenges of today.


Subject(s)
Biomedical Research/standards , Research Design/standards , Research Personnel/standards , Wounds and Injuries , Australia , Biomedical Research/education , Cooperative Behavior , Humans , Research Personnel/education
8.
Proc Inst Mech Eng H ; 224(1): 119-26, 2010.
Article in English | MEDLINE | ID: mdl-20225463

ABSTRACT

This paper investigated the biomechanics of two clinical cases of bone fracture treatments. Both fractures were treated with the same locking compression plate but with different numbers of screws as well as different plate materials. The fracture treated with 12 screws (rigid fixation) failed at 7 weeks with the plate breaking; the fracture with six screws (flexible fixation) endured the entire healing process. It was hypothesized that the plate failure in the unsuccessful case was due to the material fatigue induced by stress concentration in the plate. As the two clinical cases had different fracture locations and different plate materials, finite element simulations were undertaken for each fractured bone fixed by both a rigid and a flexible method. This enabled comparisons to be made between the rigid and flexible fixation methods. The fatigue life was assessed for each fixation method. The results showed that the stress in the rigid fixation methods could be significantly higher than that in flexible fixation methods. The fatigue analyses showed that, with the stress level in flexible fixation (i.e. with fewer screws), the plate was able to endure 2000 days, and that the plate in rigid fixation could fail by fatigue fracture in 20 days. The paper concludes that the rigid fixation method resulted in serious stress concentrations in the plate, which induced fatigue failure. The flexible fixation gave sufficient stability and was better for fracture healing.


Subject(s)
Bone Plates , Bone Screws , Femoral Fractures/physiopathology , Femoral Fractures/surgery , Fracture Fixation, Internal/instrumentation , Models, Biological , Adult , Aged , Computer Simulation , Elastic Modulus , Female , Femur/physiopathology , Femur/surgery , Fracture Fixation, Internal/methods , Humans , Male , Prosthesis Failure , Stress, Mechanical , Treatment Outcome
9.
Injury ; 41(2): 216-9, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19879577

ABSTRACT

Intramedullary nailing is the standard fixation method for displaced diaphyseal fractures of the tibia in adults. The bends in modern tibial nails allow for an easier insertion, enhance the 'bone-nail construct' stability, and reduce axial malalignments of the main fragments. Anecdotal clinical evidence indicates that current nail designs do not fit optimally for patients of Asian origin. The aim of this study was to develop a method to quantitatively assess the anatomical fitting of two different nail designs for Asian tibiae by utilising 3D computer modelling. We used 3D models of two different tibial nail designs (ETN (Expert Tibia Nail) and ETN-Proximal-Bend, Synthes), and 20 CT-based 3D cortex models of Japanese cadaver tibiae. With the aid of computer graphical methods, the 3D nail models were positioned inside the medullary cavity of the intact 3D tibia models. The anatomical fitting between nail and bone was assessed by the extent of the nail protrusion from the medullary cavity into the cortical bone, in a real bone this might lead to axial malalignments of the main fragments. The fitting was quantified in terms of the total surface area, and the maximum distance by which the nail was protruding into the cortex of the virtual bone model. In all 20 bone models, the total area of the nail protruding from the medullary cavity was smaller for the ETN-Proximal-Bend (average 540 mm(2)) compared to the ETN (average 1044 mm(2)). Also, the maximum distance of the nail protruding from the medullary cavity was smaller for the ETN-Proximal-Bend (average 1.2mm) compared to the ETN (average 2.7 mm). The differences were statistically significant (p<0.05) for both the total surface area and the maximum distance measurements. By utilising computer graphical methods it was possible to conduct a quantitative fit assessment of different nail designs. The ETN-Proximal-Bend shows a statistical significantly better intramedullary fit with less cortical protrusion than the original ETN. In addition to the application in implant design, the developed method could potentially be suitable for pre-operative planning enabling the surgeon to choose the most appropriate nail design for a particular patient.


Subject(s)
Bone Nails , Fracture Fixation, Intramedullary/instrumentation , Models, Anatomic , Prosthesis Design/methods , Tibial Fractures/surgery , Adult , Aged , Asian People , Cadaver , Computer-Aided Design , Female , Humans , Imaging, Three-Dimensional/methods , Male , Middle Aged , Tibial Fractures/ethnology
10.
J Biomech ; 43(5): 1011-5, 2010 Mar 22.
Article in English | MEDLINE | ID: mdl-19942221

ABSTRACT

Generation of subject-specific finite element (FE) models from computed tomography (CT) datasets is of significance for application of the FE analysis to bone structures. A great challenge that remains is the automatic assignment of bone material properties from CT Hounsfield Units into finite element models. This paper proposes a new assignment approach, in which material properties are directly assigned to each integration point. Instead of modifying the dataset of FE models, the proposed approach divides the assignment procedure into two steps: generating the data file of the image intensity of a bone in a MATLAB program and reading the file into ABAQUS via user subroutines. Its accuracy has been validated by assigning the density of a bone phantom into a FE model. The proposed approach has been applied to the FE model of a sheep tibia and its applicability tested on a variety of element types. The proposed assignment approach is simple and illustrative. It can be easily modified to fit users' situations.


Subject(s)
Bone Density/physiology , Finite Element Analysis , Models, Biological , Radiographic Image Interpretation, Computer-Assisted/methods , Tibia/diagnostic imaging , Tibia/physiology , Tomography, X-Ray Computed/methods , Animals , Computer Simulation , Sheep
11.
J Biomech ; 42(15): 2575-83, 2009 Nov 13.
Article in English | MEDLINE | ID: mdl-19660757

ABSTRACT

The healing process for bone fractures is sensitive to mechanical stability and blood supply at the fracture site. Most currently available mechanobiological algorithms of bone healing are based solely on mechanical stimuli, while the explicit analysis of revascularization and its influences on the healing process have not been thoroughly investigated in the literature. In this paper, revascularization was described by two separate processes: angiogenesis and nutrition supply. The mathematical models for angiogenesis and nutrition supply have been proposed and integrated into an existing fuzzy algorithm of fracture healing. The computational algorithm of fracture healing, consisting of stress analysis, analyses of angiogenesis and nutrient supply, and tissue differentiation, has been tested on and compared with animal experimental results published previously. The simulation results showed that, for a small and medium-sized fracture gap, the nutrient supply is sufficient for bone healing, for a large fracture gap, non-union may be induced either by deficient nutrient supply or inadequate mechanical conditions. The comparisons with experimental results demonstrated that the improved computational algorithm is able to simulate a broad spectrum of fracture healing cases and to predict and explain delayed unions and non-union induced by large gap sizes and different mechanical conditions. The new algorithm will allow the simulation of more realistic clinical fracture healing cases with various fracture gaps and geometries and may be helpful to optimise implants and methods for fracture fixation.


Subject(s)
Bone and Bones/injuries , Bone and Bones/physiopathology , Fracture Healing/physiology , Fractures, Bone/physiopathology , Models, Biological , Neovascularization, Physiologic/physiology , Animals , Computer Simulation , Humans