Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
1.
JAMA Netw Open ; 6(6): e2317164, 2023 06 01.
Article in English | MEDLINE | ID: mdl-37278998

ABSTRACT

Importance: Fractures of the hip have devastating effects on function and quality of life. Intramedullary nails (IMN) are the dominant implant choice for the treatment of trochanteric fractures of the hip. Higher costs of IMNs and inconclusive benefit in comparison with sliding hip screws (SHSs) convey the need for definitive evidence. Objective: To compare 1-year outcomes of patients with trochanteric fractures treated with the IMN vs an SHS. Design, Setting, and Participants: This randomized clinical trial was conducted at 25 international sites across 12 countries. Participants included ambulatory patients aged 18 years and older with low-energy trochanteric (AO Foundation and Orthopaedic Trauma Association [AO/OTA] type 31-A1 or 31-A2) fractures. Patient recruitment occurred between January 2012 and January 2016, and patients were followed up for 52 weeks (primary end point). Follow-up was completed in January 2017. The analysis was performed in July 2018 and confirmed in January 2022. Interventions: Surgical fixation with a Gamma3 IMN or an SHS. Main Outcomes and Measures: The primary outcome was health-related quality of life (HRQOL), measured by the EuroQol-5 Dimension (EQ5D) at 1-year postsurgery. Secondary outcomes included revision surgical procedure, fracture healing, adverse events, patient mobility (measured by the Parker mobility score), and hip function (measured by the Harris hip score). Results: In this randomized clinical trial, 850 patients were randomized (mean [range] age, 78.5 [18-102] years; 549 [64.6% female) with trochanteric fractures to undergo fixation with either the IMN (n = 423) or an SHS (n = 427). A total of 621 patients completed follow-up at 1 year postsurgery (304 treated with the IMN [71.9%], 317 treated with an SHS [74.2%]). There were no significant differences between groups in EQ5D scores (mean difference, 0.02 points; 95% CI, -0.03 to 0.07 points; P = .42). Furthermore, after adjusting for relevant covariables, there were no between-group differences in EQ5D scores (regression coefficient, 0.00; 95% CI, -0.04 to 0.05; P = .81). There were no between-group differences for any secondary outcomes. There were also no significant interactions for fracture stability (ß [SE] , 0.01 [0.05]; P = .82) or previous fracture (ß [SE], 0.01 [0.10]; P = .88) and treatment group. Conclusions and Relevance: This randomized clinical trial found that IMNs for the treatment of trochanteric fractures had similar 1-year outcomes compared with SHSs. These results suggest that the SHS is an acceptable lower-cost alternative for trochanteric fractures of the hip. Trial Registration: ClinicalTrials.gov Identifier: NCT01380444.


Subject(s)
Fracture Fixation, Intramedullary , Hip Fractures , Humans , Female , Aged , Male , Fracture Fixation, Intramedullary/adverse effects , Fracture Fixation, Intramedullary/methods , Bone Nails/adverse effects , Quality of Life , Bone Screws/adverse effects , Hip Fractures/surgery , Hip Fractures/etiology
2.
Injury ; 2023 Mar 12.
Article in English | MEDLINE | ID: mdl-36990902

ABSTRACT

AIM: To describe demographic findings, typical injuries and functional neurological outcomes in patients with cervical trauma and tetraplegia sustained after diving into shallow water. PATIENTS AND METHODS: A retrospective study was performed including all patients treated in BG Klinikum Hamburg suffering from tetraplegia after jumping into shallow water between 1st June 1980 and 31st July 2018. RESULTS: One hundred and sixty patients with cervical spinal injuries and tetraplegia following a dive into shallow water were evaluated. Of these, 156 patients (97.5%) were male. The mean age was 24.3 years ± 8.1 and the accidents occurred most often in inland waters (56.2%) and mostly between May and August (90.6%). In all cases there was one vertebra fractured, whereas in 48.1% of cases, two vertebrae were severed. In the majority of cases (n = 146), a surgical procedure was performed. Overall, the mean hospital stay was 202 days (±72, range: 31-403) and one patient died. On admission, 106 patients (66.2%) showed a complete lesion according to AIS A, with incomplete lesions in the remaining 54 patients (AIS B: n = 25 [15.6%], AIS C: n = 26 [16.3%], AIS D: n = 3 [1.9%]). In two thirds of the patients, the level of paralysis on admission was at the level of segments C4 (31.9%) or C5 (33.7%). Seventeen patients (10.6%) needed prehospital resuscitation. In 55 patients (34.4%), the neurological findings improved during the course of inpatient treatment and rehabilitation. Sixty-eight patients (42.5%) developed pneumonia, of which 52 patients (76.5%) were ventilated. In addition, 56.5% of patients with paralysis levels C0-C3 required ventilation, whereas only 6.3% of patients with paralysis levels C6-C7 were affected. Three patients (1.9%) were discharged from hospital with continuous ventilation. Overall, 27.4% of all AIS A patients, 56% of all AIS B patients and 46.2% of all AIS C patients improved neurologically, with 17% of all patients being able to walk. CONCLUSIONS: The consequences of a cervical spine injury after diving into shallow water are severe and lifelong. Functionally, patients may benefit from care in a specialised centre, both in the acute phase and during rehabilitation. The more incomplete the primary paralysis, the greater the possibility of neurological recovery.

3.
J Clin Med ; 11(1)2021 Dec 22.
Article in English | MEDLINE | ID: mdl-35011766

ABSTRACT

To study the mortality, cause and risk indicators of death in German patients with traumatic spinal cord injury, patients with traumatic spinal cord injury admitted to Berufsgenossenschaftliches Trauma Hospital Hamburg between 1 January 1997 and 31 December 2018, aged between 16 and 60 with a minimal survival of one year after injury, were included. Further criteria were the absence of life-limiting comorbidities at the time of injury. 223 deceased patients with traumatic spinal cord injury were identified, investigated on and partly compared to the surviving subjects. We aimed to discover specific complications that were related to Spinal Cord Injury and responsible for a possibly limited life expectancy. Data collection was performed during in- and outpatient treatment. A statistical analysis was performed to compare groups. The post-injury life expectancy was 25.0 years with a significant correlation regarding the level of lesion and severity of injury. The leading causes of death were cardiovascular diseases and pneumonia. Bladder cancer was the most common fatal malignant tumor. The life expectancy of patients suffering from traumatic spinal cord injury is limited. The longer a patient survives after injury and the lower the level of lesion, the more likely an age-related cause of death becomes. Bladder cancer is significantly more frequent when compared to the overall distribution of tumor diseases in Germany.

4.
Global Spine J ; 11(7): 1089-1098, 2021 Sep.
Article in English | MEDLINE | ID: mdl-32744071

ABSTRACT

STUDY DESIGN: Biomechanical. OBJECTIVE: This study evaluates the biomechanical properties of lag-screws used in vertebral pincer fractures at the thoracolumbar junction. METHODS: Pincer fractures were created in 18 bisegmental human specimens. The specimens were assigned to three groups depending on their treatment perspective, either bolted, with the thread positioned in the cortical or cancellous bone, or control. The specimens were mounted in a servo-hydraulic testing machine and loaded with a 500 N follower load. They were consecutively tested in 3 different conditions: intact, fractured, and bolted/control. For each condition 10 cycles in extension/flexion, torsion, and lateral bending were applied. After each tested condition, a computed tomography (CT) scan was performed. Finally, an extension/flexion fatigue loading was applied to all specimens. RESULTS: Biomechanical results revealed a nonsignificant increase in stiffness in extension/flexion of the fractured specimens compared with the intact ones. For lateral bending and torsion, the stiffness was significantly lower. Compared with the fractured specimens, no changes in stiffness due to bolting were discovered. CT scans showed an increasing fracture gap during axial loading both in extension/flexion, torsion, and lateral bending in the control specimens. In bolted specimens, the anterior fragment was approximated, and the fracture gap nullified. This refers to both the cortical and the cancellous thread positions. CONCLUSION: The results of this study concerning the effect of lag-screws on pincer fractures appear promising. Though there was little effect on stiffness, CT scans reveal a bony contact in the bolted specimens, which is a requirement for bony healing.

5.
Biomed Tech (Berl) ; 62(4): 365-373, 2017 Aug 28.
Article in English | MEDLINE | ID: mdl-27626763

ABSTRACT

BACKGROUND: Osteochondral injuries often lead to osteoarthritis of the affected joint. All established systems for refixation of osteochondral defects show certain disadvantages. To address the problem of reduced stability in resorbable implants, ultrasound-activated pins were developed. By ultrasound-activated melting of the tip of these implants, a more secure anchoring is assumed. MATERIALS AND METHODS: The aim of the study was to investigate if ultrasound-activated pins can provide secure fixation of osteochondral fragments compared to screws and conventional resorbable pins. In a biomechanical laboratory setting, osteochondral fragments of the medial femoral condyle of sheep were refixated with ultrasound-activated pins [US fused poly(L-lactide-co-D,L-lactide) (PLDLLA) pins], polydioxanone (PDA) pins and conventional titanium screws. Anchoring forces of the different fixation methods were examined, registered and compared concerning shear force and tensile force. RESULTS: Concerning the pull out test, the US fused PLDLLA pins and titanium screws (~122 N and ~203 N) showed comparable good results, while the PDA pins showed significantly lower anchoring forces (~18 N). Examination of shear forces showed a significantly higher anchoring of the screws (~248 N) than the US fused PLDLLA pins (~218 N). Nevertheless, the US fused PLDLLA pins could significantly outperform the PDA pins (~68 N) concerning shear forces. CONCLUSION: The US fused PLDLLA pins demonstrated a comparable anchorage to the fixation with screws, but were free from the disadvantages of metal implants, i.e. the need for implant removal. The PDA pin application showed inferior biomechanical properties.


Subject(s)
Absorbable Implants , Bone Nails , Knee Joint/surgery , Polyesters/chemistry , Animals , Biomechanical Phenomena , Humans , Knee Joint/physiopathology , Sheep
7.
Open Orthop J ; 8: 85-92, 2014.
Article in English | MEDLINE | ID: mdl-24851140

ABSTRACT

UNLABELLED: Reconstructive osteotomies for the treatment of Hallux valgus are among the most prevalent procedures in foot and ankle surgery. The combination of biodegradable materials with an innovative method for fixation by application of ultrasonic energy facilitates a new bonding method for fractures or osteotomies. As clinical experience is still limited, the aim of this study was to assess the safety and performance of the SonicPin system for fixation of Austin/Chevron osteotomies. Chevron osteotomy was performed on 30 patients for the treatment of Hallux valgus. The used SonicPins were made from polylactide and are selectively melted into the cancellous bone structure during insertion by ultrasonic energy. Patients were followed for one year, which included X-ray and MRI examinations as well as evaluation of life quality by EQ-5D (EuroQol). The MRI after three months showed adequate bone healing in all cases and no signs of foreign body reactions, which was again confirmed by MRI 12 months postoperatively. The bony healing after 12 months was uneventful without any signs of foreign body reactions. In summary, based on the low complication rate and the significant improvement in health related quality of life (EQ-5D) reported in this study, fixation of an Austin/Chevron osteotomy with a SonicPin for treatment of Hallux valgus can be considered to be safe and efficient over the short term. LEVEL OF CLINICAL EVIDENCE: Therapeutic Level III.

8.
BMC Musculoskelet Disord ; 14: 96, 2013 Mar 14.
Article in English | MEDLINE | ID: mdl-23496954

ABSTRACT

BACKGROUND: Manufacturers of implants and materials in the field of orthopaedics use significant amounts of funding to produce informational material to influence the decision-making process of orthopaedic surgeons with regards to choice between novel implants and techniques. It remains unclear how far orthopaedic surgeons are really influenced by the materials supplied by companies or whether other, evidence-based publications have a higher impact on their decision-making. The objective was to evaluate the subjective usefulness and usage of different sources of information upon which orthopaedic surgeons base their decisions when acquiring new implants or techniques. METHODS: We undertook an online survey of 1174 orthopaedic surgeons worldwide (of whom n = 305 were head of their department). The questionnaire included 34 items. Sequences were randomized to reduce possible bias. Questions were closed or semi-open with single or multiple answers. The usage and relevance of different sources of information when learning about and selecting orthopaedic treatments were evaluated. Orthopaedic surgeons and trainees were targeted, and were only allowed to respond once over a period of two weeks. Baseline information included country of workplace, level of experience and orthopaedic subspecialisation. The results were statistically evaluated. RESULTS: Independent scientific proof had the highest influence on decisions for treatment while OEM (Original Equipment Manufacturer) driven activities like newsletters, white papers or workshops had the least impact. Comparison of answers from the three best-represented countries in this study (Germany, UK and USA) showed some significant differences: Scientific literature and congresses are significantly more important in the US than in the UK or Germany, although they are very important in all countries. CONCLUSIONS: Independent and peer-reviewed sources of information are preferred by surgeons when choosing between methods and implants. Manufacturers of medical devices in orthopaedics employ a considerable workforce to inform or influence hospital managers and leading doctors with marketing activities. Our results indicate that it might be far more effective to channel at least some of these funds into peer-reviewed research projects, thereby assuring significantly higher acceptance of the related products.


Subject(s)
Access to Information , Choice Behavior , Decision Support Techniques , Orthopedic Procedures , Patient Selection , Attitude of Health Personnel , Chi-Square Distribution , Education, Medical, Continuing , Evidence-Based Medicine , Health Care Surveys , Health Knowledge, Attitudes, Practice , Humans , Internet , Orthopedic Procedures/education , Orthopedic Procedures/instrumentation , Orthopedic Procedures/methods , Surveys and Questionnaires
9.
Int Orthop ; 37(4): 667-72, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23359099

ABSTRACT

PURPOSE: A biomechanical study was performed to test the hypothesis that a new anatomically preformed, thinner, soft-tissue protecting plate system for distal humeral fractures (Tifix®-hybridplate [HP]) would show comparable results in the quasi-static and dynamic testings compared to two conventional implants: The 3.5-mm reconstruction plate (RP) providing primary stability with normal bone mineral density (BMD), and a multidirectional locking plate (Tifix(®)-plate [P]) which can be used with poor bone quality. METHODS: The Tifix(®)-HP was developed by the working group. The biomechanical testing was performed on a C2-fracture-model in 24 synthetic humeri. Three groups, each with eight bone-implant-constructs, were analysed in quasi-static and dynamic tests. RESULTS: The quasi-static measurements showed that under extension loading both locking plates (Tifix(®)-P, Tifix(®)-HP) were significantly stiffer than the reconstruction plate, and that the Tifix(®)-HP had a significantly lower stiffness than the two other implants under flexion loading. In the dynamic tests the Tifix(®)-P allowed significantly less fracture motion compared to the Tifix(®)-HP and the reconstruction plate. In an osteopaenic bone model locking plates failed only under much higher dynamic force than the reconstruction plate. The reconstruction plate and the Tifix(®)-P always failed through screw loosening, whereas the newly developed Tifix(®)-HP showed screw loosening in only one third of cases. CONCLUSION: The hypothesis that the newly designed plate system showed comparable results in the quasi-static and dynamic tests compared to the conventional implants with a significantly lower implant volume and thickness was confirmed.


Subject(s)
Bone Plates , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Humeral Fractures/surgery , Internal Fixators , Biomechanical Phenomena , Bone Screws , Humans , Humerus/injuries , Humerus/surgery , Materials Testing , Stress, Mechanical
10.
Pacing Clin Electrophysiol ; 36(6): 714-8, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23305494

ABSTRACT

BACKGROUND: Stability of threshold currents during long-term use of phrenic nerve stimulation has been questioned. METHODS AND RESULTS: Between January 5, 1988, and March 5, 2008, 49 patients with functional C2-tetraplegia received an Atrostim PNS (Atrotech Ltd., Tampere, Finland) as treatment of their respiratory insufficiency; a follow-up of 35 of such patients was carried out exclusively in our institution for 6.3 (4.44) 0.04-15.75 years (mean [standard deviation (SD)] range). The device employed four-pole sequential nerve stimulation, which provided four threshold currents subsequently evaluated for each phrenic nerve. Stimulation data were prospectively recorded. The differences between threshold currents recorded 1 year after implantation and the last recorded values were 0.33-0.43 (0.44-0.63) 0-2.9 mA. After having excluded the data of eight patients with values >1 mA (= mean + SD), we registered the differences for the remaining patients of 0.15-0.24 (0.14-0.24) 0-0.95 mA, which is just twice the adjustment accuracy of the device. Out of the eight problem cases one had, and two were suspected to have, surgical trauma; all three nerves recovered. In two cases the values steadily increasing over years might have been caused by unspecific foreign body reaction. Two cases with values >1 mA for different durations at different electrodes might be caused by biofilm, and one patient displaying steadily increasing values lived, unwilling to live, only 2 years after the implantation. CONCLUSION: Thus, there was no permanent nerve injury and in 77% of the presented cases threshold currents remained stable.


Subject(s)
Electrodes , Phrenic Nerve , Quadriplegia/complications , Quadriplegia/rehabilitation , Sleep Apnea, Central/etiology , Sleep Apnea, Central/prevention & control , Transcutaneous Electric Nerve Stimulation/instrumentation , Adolescent , Adult , Aged , Child , Child, Preschool , Differential Threshold , Equipment Design , Equipment Failure Analysis , Female , Humans , Infant , Male , Middle Aged , Platinum/chemistry , Quadriplegia/diagnosis , Sleep Apnea, Central/diagnosis , Treatment Outcome , Young Adult
11.
Open Access J Sports Med ; 4: 243-9, 2013.
Article in English | MEDLINE | ID: mdl-24379730

ABSTRACT

INTRODUCTION: Although known as a possible graft option for decades, quadriceps tendon grafts have often been termed a second-line graft option. We report a consecutive case series using this method as the primary treatment line. The rationale for this study was to evaluate the midterm results of this method in a prospective and consecutive case series. The primary study question was to determine the clinical results 24-36 months after primary anterior cruciate ligament (ACL) reconstruction using a bone plug-free quadriceps tendon autograft fixed with bioabsorbable cross-pins. MATERIALS AND METHODS: The study population included 55 patients, of whom 24 were female (43.6%). The mean age at the index procedure was 31.7 years (15-58 years). All patients received an ACL construction using a bone block-free quadriceps tendon graft fixed with resorbable cross-pins. The postoperative regimen included partial weight-bearing for 3 weeks and flexion limited to 90° for six weeks; an orthosis was not used. The mean follow-up duration was 29.5 months (24.3-38.5 months) after the index procedure. The International Knee Documentation Committee (IKDC) subjective score and examination form was assessed, as well as the Lysholm and Gillquist score and the Tegner activity index. The Rolimeter arthrometer was used to assess the anterior laxity of the knee. RESULTS: Graft harvesting was possible in all cases; a bony extension was never required. On average, graft length was measured at 8.8 cm (7.5-10 cm). The mean IKDC subjective score at follow-up was 80.44 points (55.17-100 points, standard deviation [SD] 12.05). The mean preinjury Tegner activity index was 4.98 (2-7) compared to a mean value of 4.16 (2-7, SD 0.8) at follow-up. There was a mean loss of 0.82 index points. The average Lysholm and Gillquist score was 89 points (65-100, SD 17.7). Of the results, 89.1% were in the good or very good groups; in one case (1.8%), the result was poor, while the rest were fair. CONCLUSION: ACL reconstruction using a bone plug-free quadriceps tendon autograft achieved satisfactory results in a midterm review.

12.
BMC Musculoskelet Disord ; 13: 141, 2012 Aug 08.
Article in English | MEDLINE | ID: mdl-22873207

ABSTRACT

BACKGROUND: A minimal invasive approach for elective hip surgery has been implemented in our institution in the past. It is widely hypothesized that implanting artificial hips in a minimal invasive fashion decreases surgical trauma and is helpful in the rehabilitation process in elective hip surgery. Thereby geriatric patients requiring emergency hip surgery also could theoretically benefit from a procedure that involves less tissue trauma. METHODS: Sixty patients who sustained a fractured neck of femur were randomly assigned into two groups. In the minimal invasive arm, the so called "direct anterior approach" (DAA) was chosen, in the conventional arm the Watson-Jones-Approach was used for implantation of a bipolar hemi-arthroplasty.Primary outcome parameter was the mobility as measured by the four-item-Barthel index. Secondary outcome parameters included pain, haemoglobin-levels, complications, duration of surgery, administration of blood transfusion and external length of incision. Radiographs were evaluated. RESULTS: A statistically significant difference (p = 0,009) regarding the mobility as measured with the four-item Barthel index was found at the 5th postoperative day, favouring the DAA. Evaluation of the intensity of pain with a visual analogue scale (VAS) showed a statistically significant difference (p = 0,035) at day 16. No difference was evident in the comparison of radiographic results. CONCLUSIONS: Comparing two different approaches to the hip joint for the implantation of a bipolar hemi-arthroplasty after fractured neck of femur, it can be stated that mobilization status is improved for the DAA compared to the WJA when measured by the four-item Barthel index, there is less pain as measured using the VAS. There is no radiographic evidence that a minimal invasive technique leads to inferior implant position. LEVEL OF EVIDENCE: Level II therapeutic study.


Subject(s)
Femoral Neck Fractures/surgery , Hemiarthroplasty/methods , Hip Joint/surgery , Activities of Daily Living , Aged , Aged, 80 and over , Biomechanical Phenomena , Disability Evaluation , Female , Femoral Neck Fractures/diagnostic imaging , Femoral Neck Fractures/physiopathology , Fracture Healing , Germany , Hemiarthroplasty/adverse effects , Hip Joint/diagnostic imaging , Hip Joint/physiopathology , Humans , Male , Minimally Invasive Surgical Procedures , Mobility Limitation , Pain Measurement , Pain, Postoperative/diagnosis , Pain, Postoperative/etiology , Prospective Studies , Radiography , Recovery of Function , Time Factors , Treatment Outcome
13.
Clin Orthop Relat Res ; 470(7): 2021-8, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22585352

ABSTRACT

BACKGROUND: Anterior screw fixation has been widely adopted for the treatment of type II dens fractures. However, there is still controversy regarding whether one- or two-screw fixation is more appropriate. QUESTIONS/PURPOSES: We addressed three questions: (1) Do one- and two-screw fixation techniques differ regarding shear stiffness and rotational stiffness? (2) Can shear stiffness and rotational stiffness after screw fixation be restored to normal? (3) Does stiffness after screw fixation correlate with bone mineral density (BMD)? METHODS: We randomly assigned 14 fresh axes into two groups (seven axes each): one receiving one-screw fixation and another receiving two-screw fixation. Shear and torsional stiffness were measured using a nondestructive low-load test in six directions. A transverse osteotomy then was created at the base of the dens and fixed using one or two screws. Shear and torsional stiffness were tested again under the same testing conditions. RESULTS: Mean stiffness in all directions after screw fixation was similar in both groups. The stiffness after one- and two-screw fixation was not restored to normal: the mean shear stiffness restored ratio was less than 50% and the mean torsional stiffness restored ratio was less than 6% in both groups. BMD did not correlate with mean stiffness after screw fixation in both groups. CONCLUSIONS: One- and two-screw fixation for type II dens fractures provide similar stability but neither restores normal shear or torsional stiffness. CLINICAL RELEVANCE: One-screw fixation might be used as an alternative to two-screw fixation. Assumed BMD should not influence surgical decision making.


Subject(s)
Bone Screws , Fracture Fixation, Internal/instrumentation , Odontoid Process/surgery , Spinal Fractures/surgery , Aged , Aged, 80 and over , Analysis of Variance , Biomechanical Phenomena , Bone Density , Cadaver , Female , Germany , Humans , Male , Middle Aged , Odontoid Process/diagnostic imaging , Odontoid Process/injuries , Odontoid Process/physiopathology , Prosthesis Design , Radiography , Rotation , Spinal Fractures/diagnostic imaging , Spinal Fractures/physiopathology , Stress, Mechanical , Time Factors , Torsion, Mechanical , Treatment Outcome
14.
Open Orthop J ; 6: 1-7, 2012.
Article in English | MEDLINE | ID: mdl-22312417

ABSTRACT

Development of novel implants in orthopaedic trauma surgery is based on limited datasets of cadaver trials or artificial bone models. A method has been developed whereby implants can be constructed in an evidence based method founded on a large anatomic database consisting of more than 2.000 datasets of bones extracted from CT scans. The aim of this study was the development and clinical application of an anatomically pre-contoured plate for the treatment of distal fibular fractures based on the anatomical database.48 Caucasian and Asian bone models (left and right) from the database were used for the preliminary optimization process and validation of the fibula plate. The implant was constructed to fit bilaterally in a lateral position of the fibula. Then a biomechanical comparison of the designed implant to the current gold standard in the treatment of distal fibular fractures (locking 1/3 tubular plate) was conducted. Finally, a clinical surveillance study to evaluate the grade of implant fit achieved was performed. The results showed that with a virtual anatomic database it was possible to design a fibula plate with an optimized fit for a large proportion of the population. Biomechanical testing showed the novel fibula plate to be superior to 1/3 tubular plates in 4-point bending tests. The clinical application showed a very high degree of primary implant fit. Only in a small minority of cases further intra-operative implant bending was necessary. Therefore, the goal to develop an implant for the treatment of distal fibular fractures based on the evidence of a large anatomical database could be attained. Biomechanical testing showed good results regarding the stability and the clinical application confirmed the high grade of anatomical fit.

15.
J Orthop Surg Res ; 6: 46, 2011 Sep 18.
Article in English | MEDLINE | ID: mdl-21923948

ABSTRACT

BACKGROUND: Elastic Stable intramedullary Nailing (ESIN) of dislocated diaphyseal femur fractures has become an accepted method for the treatment in children and adolescents with open physis. Studies focused on complications of this technique showed problems regarding stability, usually in complex fracture types such as spiral fractures and in older children weighing > 40 kg. Biomechanical in vitro testing was performed to evaluate the stability of simulated spiral femoral fractures after retrograde flexible titanium intramedullary nail fixation with and without End caps. METHODS: Eight synthetic adolescent-size femoral bone models (Sawbones® with a medullar canal of 10 mm and a spiral fracture of 100 mm length identically sawn by the manufacturer) were used for each group. Both groups underwent retrograde fixation with two 3.5 mm Titanium C-shaped nails inserted from medial and lateral entry portals. In the End Cap group the ends of the nails of the eight specimens were covered with End Caps (Synthes Company, Oberdorf, Switzerland) at the distal entry. RESULTS: Beside posterior-anterior stress (4.11 Nm/mm vs. 1.78 Nm/mm, p < 0.001), the use of End Caps demonstrated no higher stability in 4-point bending compared to the group without End Caps (anterior-posterior bending 0.27 Nm/mm vs. 0.77 Nm/mm, p < 0.001; medial-lateral bending 0.8 Nm/mm vs. 1.10 Nm/mm, p < 0.01; lateral-medial bending 0.53 Nm/mm vs. 0.86 Nm/mm, p < 0.001) as well as during internal rotation (0.11 Nm/° vs. 0.14 Nm/°, p < 0.05). During compression in 9°- position and external rotation there was no statistical significant difference (0.37 Nm/° vs. 0.32 Nm/°, p = 0.13 and 1.29 mm vs. 2.18 mm, p = 0.20, respectively) compared to the "classic" 2-C-shaped osteosynthesis without End Caps. CONCLUSION: In this biomechanical study the use of End Caps did not improve the stability of the intramedullary flexible nail osteosynthesis.


Subject(s)
Bone Nails , Femoral Fractures/surgery , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Models, Biological , Biomechanical Phenomena , Equipment Design , Femur/diagnostic imaging , Femur/surgery , Fluoroscopy , Humans
16.
J Orthop Trauma ; 25(10): 596-602, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21670709

ABSTRACT

OBJECTIVES: To evaluate the results of plate osteosynthesis using either polyaxial or nonpolyaxially locked screw-plate systems in proximal humeral fractures in the elderly. DESIGN: Prospective, randomized. SETTING: Level I trauma center. METHODS: Fifty-six patients (older than 60 years) with isolated, displaced three- and four-part fractures were included. Twenty-five patients (median age, 75.5 years) were randomized to a polyaxial locking screw plate (Group 1), whereas 31 patients (median age, 72 years) were treated with a locking screw plate (Group 2). Follow-up evaluations were performed 3, 6, and 12 months postoperatively using the Simple Shoulder Test, Disabilities of the Arm, Shoulder and Hand score, and Constant score as well as radiographs. The results and the complications were compared between both groups. RESULTS: Forty-eight patients were available for follow-up (Group 1, 20 of 25; Group 2, 28 of 31). The Simple Shoulder Test, Disabilities of the Arm, Shoulder and Hand, and Constant score improved significantly from 3 to 12 months and did not differ between groups. Twelve months after the index procedure, the Simple Shoulder Test score was 8.6 ± 3.2 points in Group 1 and 9.7 ± 1.8 points in Group 2. The Disabilities of the Arm, Shoulder and Hand score was 17.8 ± 16.2 in Group 1 and 15.7 ± 11.8 in Group 2. The mean Constant score amounted to 73% ± 17% in Group 1 and 81% ± 13% in Group 2. There were six complications in Group 1 and eight in Group 2. CONCLUSIONS: Both the functional outcomes and the rate of complications after polyaxial locked plate osteosynthesis of proximal humeral fractures in elderly patients were comparable to those treated with nonpolyaxial implants. Despite the theoretical advantages of polyaxial locked plating in proximal humerus fractures, this study could not show a verifiable clinical advantage of these plates.


Subject(s)
Bone Plates , Bone Screws , Fracture Fixation, Internal/instrumentation , Shoulder Fractures/surgery , Aged , Humans , Prospective Studies , Prosthesis Design , Single-Blind Method , Surveys and Questionnaires , Time Factors
17.
Injury ; 42(1): 44-6, 2011 Jan.
Article in English | MEDLINE | ID: mdl-20828691

ABSTRACT

Only a minority of sternal fractures require osteosynthesis. Unstable non-union of the sternum is a very disabling condition which often requires treatment. The method most often used is tension-wiring. Due to loosening of the tensile strength or wire cut-out, this method often fails. We report the results of locked plate osteosynthesis of sternal non-union and displaced fractures. Over a five-year period, 12 patients have been treated using this method in a multicentre trial. Mean age at trauma was 32.8 years, the implant used in all cases was an 8-hole titanium plate, the fixation of the screws is based on the principles of angular stable fixation.In all cases the index procedure was possible, in all cases there was bony healing at follow-up examination.Multidirectional locked plating offers a reliable method for the successful treatment of sternal nonunion and displaced fractures.


Subject(s)
Bone Plates , Fracture Fixation, Internal/methods , Fractures, Ununited/surgery , Sternum/injuries , Adolescent , Adult , Bone Screws , Female , Fracture Fixation, Internal/instrumentation , Fractures, Ununited/physiopathology , Humans , Male , Middle Aged , Osteogenesis/physiology , Prospective Studies , Sternum/surgery , Surveys and Questionnaires , Titanium , Tomography, X-Ray Computed , Treatment Outcome , Young Adult
18.
Am J Sports Med ; 38(5): 983-91, 2010 May.
Article in English | MEDLINE | ID: mdl-20436053

ABSTRACT

BACKGROUND: The suture-bridging technique is a new arthroscopic technique to repair rotator cuff tears. Biomechanical advantages compared with double-row fixations have been described. HYPOTHESIS: The authors hypothesized that arthroscopic suture-bridging repair of the supraspinatus tendon would result in a superior clinical outcome and lower retear rates compared with previously published results after double-row fixation. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Fifty-one consecutive patients, with a median age of 62 years (range, 37-76 years), who had undergone an arthroscopic suture-bridging repair of an isolated supraspinatus tendon tear were evaluated in this prospective study 4, 12, and a median of 24 months postoperatively. Subjective and functional outcome was assessed using the simple shoulder test and Constant score. With magnetic resonance imaging 12 months postoperatively, the tendon integrity and potential predictors of failures were evaluated. RESULTS: The simple shoulder test scores improved significantly from 9 points (range, 1-12 points) at 4 months, to 12 points (range, 1-12 points) at 12 months, and 12 points (range, 5-12 points) at 24 months postoperatively. The Constant score increased significantly from preoperative 64% (range, 37%-92%) to 82% (range, 36%-100%) at 4 months, 96% (range, 49%-100%) at 12 months, and 96% (range, 64%-100%) at 24 months postoperatively. Magnetic resonance imaging 12 months after surgery showed retears in 28.9%. Two different types of retears could be observed: insufficiently healed and medially retorn supraspinatus tendons. The Constant score did not differ significantly between the groups with retears and intact repairs. A patient age of more than 60 years was found to influence tendon healing significantly. CONCLUSION: The hypothesis, that arthroscopic suture-bridging repair of the supraspinatus tendon would result in a superior clinical outcome and lower retear rates compared with previously published results after double-row fixation, could not be confirmed. The functional outcome after the new suture-bridging technique was good and comparable with the reported results after double-row repair from the literature. A structural failure of tendon repair was not identical to clinical failure.


Subject(s)
Arthroscopy/methods , Rotator Cuff Injuries , Rotator Cuff/surgery , Suture Techniques , Tendon Injuries/surgery , Adult , Aged , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Orthopedic Procedures/methods , Prospective Studies , Range of Motion, Articular , Plastic Surgery Procedures/methods , Rupture/diagnosis , Rupture/surgery , Treatment Outcome
19.
Eur J Trauma Emerg Surg ; 36(1): 53-9, 2010 Feb.
Article in English | MEDLINE | ID: mdl-26815569

ABSTRACT

We concluded a retrospective study of the outcomes of a consecutive series of Vancouver B1 and C femoral injuries using two specific locked implants. The study center is a dedicated trauma hospital with a large catchment area. Over a five-year period we treated 58 patients with a periprosthetic fracture of the femur with an angular stable plate, defined as the index procedure. The mean age at the index procedure was 72.4 years; 40 patients were female (69%). In 32 cases (55.2%) we saw a hip endoprosthesis, in 21 cases (36.2%) a knee endoprosthesis, and in five cases both (8.6%). Outcome measures were intra- and postoperative complications, bony union, degree of mobility and social status with comparison to the preoperative status, Barthel index, and timed ''up and go'' test. Union occurred in 56 cases (96.5%) after the index procedure. Three patients were bedridden before the injury; the remainder regained full weight-bearing status. The mean duration until full weight-bearing status in these patients was 8.6 weeks (4-13). Early implant failure with proximal dislocation of the screws occurred in two cases (3.5% revision rate). At follow up, 78% had maintained the same social status as before the injury. Fifty-two patients (89%) had regained their previous level of mobility. The mean Barthel index was 85 points (70-100) out of a possible 100, and improved from a mean of 35 points at the start of rehabilitation. It decreased on average by ten points compared to the preoperative status. The mean ''up and go'' time was measured as 21.4 s. In conclusion, polyaxial plates can achieve excellent surgical results. On the other hand, patients with this type of injury exhibit a clear deterioration in their social status, especially regarding lower limb motor function and self-independence.

20.
J Pediatr Orthop B ; 18(6): 296-301, 2009 Nov.
Article in English | MEDLINE | ID: mdl-19620894

ABSTRACT

Twenty-eight patients with 31 closed fractures (27 acute fractures and four with malalignment after conservative treatment) of the metacarpal bones 2-5 were treated with only one elastic stable intramedullary nail and followed prospectively. Treatment protocol was without immobilization or physiotherapy. These patients were reviewed at a mean follow-up time of 15 months for ultrasound results as well as functional outcome concerning complications, pain, range of motion, and grip strength measured with a Vernier-Dynamometer. Satisfaction of the patients was investigated by Clients Satisfaction Questionnaire. Radiographs before nail removal, ultrasound, and clinical examination always showed complete union of the fracture without deviation of axis. All patients gained full range of motion without any limits in daily activity and sports. There was no loss of grip strength compared with the other hand. Patients' satisfaction was very high, especially because of almost no postoperative pain and lack of immobilization. This method can be offered as an effective and safe alternative in the treatment of closed displaced fractures of the 2-5 metacarpus without significant complications.


Subject(s)
Fracture Fixation, Intramedullary/methods , Fractures, Closed/surgery , Metacarpal Bones/injuries , Adolescent , Bone Nails , Child , Female , Fracture Fixation, Intramedullary/instrumentation , Fractures, Closed/diagnostic imaging , Hand Strength/physiology , Humans , Male , Metacarpal Bones/diagnostic imaging , Metacarpal Bones/surgery , Patient Satisfaction , Prospective Studies , Radiography , Range of Motion, Articular , Recovery of Function , Surveys and Questionnaires , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...