Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Atherosclerosis ; 318: 22-31, 2021 02.
Article in English | MEDLINE | ID: mdl-33450475

ABSTRACT

BACKGROUND AND AIMS: The value of serial coronary artery calcium (CAC) scores to predict changes in absolute myocardial perfusion and epicardial vasomotor function is poorly documented. This study explored the association between progression of CAC score and changes in absolute myocardial perfusion. METHODS: Fifty-three patients (26% female) with de novo single-vessel coronary artery disease underwent [15O]H2O positron emission tomography/computed tomography at 1 month (baseline), 1 year, and 3 years after complete revascularization with percutaneous coronary intervention (PCI) to assess CAC scores, hyperemic myocardial blood flow (hMBF), coronary flow reserve (CFR) and cold pressor test MBF (CPT-MBF), within the context of the VANISH trial. RESULTS: Baseline CAC score was 0 in 9%, 0.1-99.9 in 40%, 100-399.9 in 36% and ≥400 in 15% of patients, respectively. Mixed model-analysis allowed for averaging perfusion indices over all time points: hMBF (3.74 ± 0.83; 3.33 ± 0.79; 3.08 ± 0.78 and 2.44 ± 0.74 mL min-1·g-1) and CFR (3.82 ± 1.12; 3.17 ± 0.80; 3.19 ± 0.81; 2.63 ± 0.92) were lower among higher baseline CAC groups (p < 0.01; p = 0.03). However, no significant interaction was found between baseline CAC groups and time after PCI for all perfusion indices, denoting that evolution of perfusion indices over time was not significantly different between CAC groups. Furthermore, CAC progression was not correlated with evolution of hMBF (r = 0.08, p = 0.57), CFR (r = 0.09, p = 0.53) or CPT-MBF (r = 0.03, p = 0.82) during 3 years of follow-up. CONCLUSIONS: Higher baseline CAC was associated with lower hMBF and CFR. However, both baseline CAC and its progression were not associated with evolution of absolute hMBF, CFR and CPT-MBF over time, suggesting that CAC score and progression of CAC are poor indicators of change in absolute myocardial perfusion.


Subject(s)
Coronary Artery Disease , Myocardial Perfusion Imaging , Percutaneous Coronary Intervention , Calcium , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Circulation , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Female , Humans , Male , Percutaneous Coronary Intervention/adverse effects , Perfusion , Positron Emission Tomography Computed Tomography , Positron-Emission Tomography
2.
Neth Heart J ; 28(Suppl 1): 57-65, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32780333

ABSTRACT

Determining the anatomic severity and extent of coronary artery disease (CAD) by means of coronary computed tomography angiography (CCTA) and its effect on perfusion using myocardial perfusion imaging (MPI) form the pillars of the non-invasive imaging assessment of CAD. This review will 1) focus on CCTA and [15O]H2O positron emission tomography MPI as stand-alone imaging modalities and their combined use for detecting CAD, 2) highlight some of the lessons learned from the PACIFIC trial (Comparison of Coronary CT Angiography, SPECT, PET, and Hybrid Imaging for Diagnosis of Ischemic Heart Disease Determined by Fractional Flow Reserve (FFR) (NCT01521468)), and 3) discuss the use of [15O]H2O PET MPI in the clinical work-up of patients with a chronic coronary total occlusion (CTO).

3.
J Cardiovasc Comput Tomogr ; 14(1): 60-67, 2020.
Article in English | MEDLINE | ID: mdl-31302028

ABSTRACT

BACKGROUND: Scan quality can have a significant effect on the diagnostic performance of non-invasive imaging techniques. However, the extent of its influence has scarcely been investigated in a head-to-head manner. METHODS: Two-hundred and eight patients underwent CCTA, SPECT, and PET prior to invasive fractional flow reserve measurements. Scan quality was classified as either good, moderate, or poor. RESULTS: Distribution of good, moderate, and poor quality scans was; CCTA; 66%, 22%, 13%; SPECT; 52%, 38%, 9%; PET; 86%, 13%, 1%. Good quality CCTA scans possessed a higher specificity (75% vs. 31%, p = 0.001), positive predictive value (PPV, 71% vs. 51%, p = 0.050), and accuracy (80% vs. 60%, p = 0.009) compared to moderate quality scans, while sensitivity (94%) and negative predictive value (NPV, 88%) were similar to moderate and poor quality scans. Sensitivity (76%), NPV (84%), and accuracy (85%) of good quality SPECT scans was superior to those of moderate (41% p = 0.001, 56% p = 0.010, 70% p = 0.010) and poor quality (30% p = 0.003, 65% p = 0.069, 63% p = 0.038). Specificity (92%) and PPV (87%) of good quality SPECT scans did not differ from scans of diminished quality. Good quality PET scans exhibited high sensitivity (84%), specificity (86%), NPV (88%), PPV (81%) and accuracy (85%), which was comparable to scans of lesser quality. Good quality CCTA, SPECT, and PET scans demonstrated a similar diagnostic accuracy (p = 0.247). CONCLUSION: Diagnostic performance of CCTA, and SPECT is hampered by scan quality, while the diagnostic value of PET is not affected. Good quality CCTA, SPECT, and PET scans possess a high diagnostic accuracy.


Subject(s)
Computed Tomography Angiography , Coronary Angiography , Fractional Flow Reserve, Myocardial , Multidetector Computed Tomography , Myocardial Ischemia/diagnostic imaging , Myocardial Perfusion Imaging , Positron Emission Tomography Computed Tomography , Tomography, Emission-Computed, Single-Photon , Aged , Clinical Trials as Topic , Female , Humans , Male , Middle Aged , Myocardial Ischemia/physiopathology , Predictive Value of Tests , Reproducibility of Results
4.
Data Brief ; 27: 104584, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31687432

ABSTRACT

Scan quality directly impacts the diagnostic performance of non-invasive imaging modalities as reported in a substudy of the PACIFC-trial: "Impact of Scan Quality on the Diagnostic Performance of CCTA, SPECT, and PET for Diagnosing Myocardial Ischemia Defined by Fractional Flow Reserve" [1]. This Data-in-Brief paper supplements the hereinabove mentioned article by presenting the diagnostic performance of CCTA, SPECT, and PET on a per vessel level for the detection of hemodynamic significant coronary artery disease (CAD) when stratified according to scan quality and vascular territory.

5.
J Cardiovasc Comput Tomogr ; 13(4): 179-187, 2019.
Article in English | MEDLINE | ID: mdl-31302027

ABSTRACT

BACKGROUND: A diminished coronary lumen volume to left ventricle mass ratio (V/M) derived from coronary computed tomography angiography (CCTA) has been proposed as factor contributing to impaired myocardial blood flow (MBF) even in the absence of obstructive disease on invasive coronary angiography (ICA). METHODS: Patients underwent CCTA, and positron emission tomography (PET) prior to ICA. Matched global V/M, global, and vessel specific hyperaemic MBF (hMBF), coronary flow reserve (CFR), and, FFR were available for 431 vessels in 152 patients. The median V/M (20.71 mm3/g) was used to divide the population into patients with either a low V/M or a high V/M. RESULTS: Overall, a higher percentage of vessels with an abnormal hMBF and FFR (34% vs. 19%, p = 0.009 and 20% vs. 9%, p = 0.004), as well as a lower FFR (0.93 [interquartile range: 0.85-0.97] vs. 0.95 [0.89-0.98], p = 0.016) values were observed in the low V/M group. V/M was weakly associated with vessel specific hMBF (R = 0.148, p = 0.027), and FFR (R = 0.156, p < 0.001). Among vessels with non-obstructive CAD on ICA (361 vessels), no association between V/M and vessel specific hMBF nor CFR was noted. However, in the absence of obstructive CAD, V/M was associated with (R = 0.081, p = 0.027), and independently predictive for FFR (p = 0.047). CONCLUSION: Overall, an abnormal vessel specific hMBF and FFR were more prevalent in patients with a low V/M compared to those with a high V/M. Furthermore, V/M was weakly associated with vessel specific hMBF and FFR. In the absence of obstructive CAD on ICA, V/M was weakly associated with notwithstanding independently predictive for FFR.


Subject(s)
Computed Tomography Angiography , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Fractional Flow Reserve, Myocardial , Heart Ventricles/diagnostic imaging , Aged , Clinical Trials as Topic , Coronary Artery Disease/physiopathology , Coronary Vessels/physiopathology , Female , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Predictive Value of Tests
6.
Eur J Nucl Med Mol Imaging ; 45(7): 1091-1100, 2018 07.
Article in English | MEDLINE | ID: mdl-29470616

ABSTRACT

PURPOSE: Traditionally, interpretation of myocardial perfusion imaging (MPI) is based on visual assessment. Computer-based automated analysis might be a simple alternative obviating the need for extensive reading experience. Therefore, the aim of the present study was to compare the diagnostic performance of automated analysis with that of expert visual reading for the detection of obstructive coronary artery disease (CAD). METHODS: 206 Patients (64% men, age 58.2 ± 8.7 years) with suspected CAD were included prospectively. All patients underwent 99mTc-tetrofosmin single-photon emission computed tomography (SPECT) and invasive coronary angiography with fractional flow reserve (FFR) measurements. Non-corrected (NC) and attenuation-corrected (AC) SPECT images were analyzed both visually as well as automatically by commercially available SPECT software. Automated analysis comprised a segmental summed stress score (SSS), summed difference score (SDS), stress total perfusion deficit (S-TPD), and ischemic total perfusion deficit (I-TPD), representing the extent and severity of hypoperfused myocardium. Subsequently, software was optimized with an institutional normal database and thresholds. Diagnostic performances of automated and visual analysis were compared taking FFR as a reference. RESULTS: Sensitivity did not differ significantly between visual reading and most automated scoring parameters, except for SDS, which was significantly higher than visual assessment (p < 0.001). Specificity, however, was significantly higher for visual reading than for any of the automated scores (p < 0.001 for all). Diagnostic accuracy was significantly higher for visual scoring (77.2%) than for all NC images scores (p < 0.05), but not compared with SSS AC and S-TPD AC (69.8% and 71.2%, p = 0.063 and p = 0.134). After optimization of the automated software, diagnostic accuracies were similar for visual (73.8%) and automated analysis. Among the automated parameters, S-TPD AC showed the highest accuracy (73.5%). CONCLUSION: Automated analysis of myocardial perfusion SPECT can be as accurate as visual interpretation by an expert reader in detecting significant CAD defined by FFR.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Image Processing, Computer-Assisted , Myocardial Perfusion Imaging , Tomography, Emission-Computed, Single-Photon , Adult , Automation , Coronary Angiography , Female , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity
7.
BMC Nephrol ; 18(1): 149, 2017 May 02.
Article in English | MEDLINE | ID: mdl-28464802

ABSTRACT

BACKGROUND: Vascular calcification is a major contributing factor to mortality in end stage renal disease (ESRD). Despite the efficacy of phosphate binders to improve hyperphosphatemia, data on vascular calcification are less clear. There seems to be a difference in attenuation or delay in progression between different binders. In this in vitro experiment we tested whether phosphate binders could limit bioavailability of vitamin K2 by undesired binding. Vitamin K-deficiency limits activation of the vascular tissue mineralization inhibitor matrix γ-carboxyglutamate (Gla) protein (MGP) thereby exacerbating vascular calcification. METHODS: In this experiment vitamin K2 (menaquinone-7; MK-7) binding was assessed by adding 1 mg of vitamin K2 to a medium with pH 6 containing 67 mg phosphate binder with either 7 mg of phosphate or no phosphate. Five different phosphate binders were tested. After five and a half hours vitamin K was analyzed by HPLC. All experiments were performed in triplicate. RESULTS: Sucroferric-oxyhydroxide and sevelamer carbonate did not significantly bind vitamin K2, both in solution only containing vitamin K2 or in combination with phosphate. Calcium acetate/magnesium carbonate binds vitamin K2 strongly both in absence (p = 0.001) and presence of phosphate (p = 0.003). Lanthanum carbonate significantly binds vitamin K2 in solution containing only vitamin K2 (p = 0.005) whereas no significant binding of vitamin K2 was observed in the solution containing vitamin K2 and phosphate (p = 0.462). Calcium carbonate binds vitamin K2 significantly in a solution with vitamin K2 and phosphate (p = 0.009) whereas without phosphate no significant binding of vitamin K2 was observed (p = 0.123). CONCLUSIONS: Sucroferric-oxyhydroxide and sevelamer carbonate were the only binders of the five binders studied that did not bind vitamin K2 in vitro. The presence or absence of phosphate significantly interferes with vitamin K2 binding so phosphate binders could potentially limit bioavailability vitamin K2.


Subject(s)
Chelating Agents/chemistry , Phosphates/chemistry , Vitamin K/chemistry , Protein Binding
SELECTION OF CITATIONS
SEARCH DETAIL
...