Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
JPRAS Open ; 41: 61-74, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38948075

ABSTRACT

Flap necrosis continues to occur in skin free flap autologous breast reconstruction. Therefore, we investigated the benefits of indocyanine green angiography (ICGA) using quantitative parameters for the objective, perioperative evaluation of flap perfusion. In addition, we investigated the feasibility of hyperspectral (HSI) and thermal imaging (TI) for postoperative flap monitoring. A single-center, prospective observational study was performed on 15 patients who underwent deep inferior epigastric perforator (DIEP) flap breast reconstruction (n=21). DIEP-flap perfusion was evaluated using ICGA, HSI, and TI using a standardized imaging protocol. The ICGA perfusion curves and derived parameters, HSI extracted oxyhemoglobin (oxyHb) and deoxyhemoglobin (deoxyHb) values, and flap temperatures from TI were analyzed and correlated to the clinical outcomes. Post-hoc quantitative analysis of intraoperatively collected data of ICGA application accurately distinguished between adequately and insufficiently perfused DIEP flaps. ICG perfusion curves identified the lack of arterial inflow (n=2) and occlusion of the venous outflow (n=1). In addition, a postoperatively detected partial flap epidermolysis could have been predicted based on intraoperative quantitative ICGA data. During postoperative monitoring, HSI was used to identify impaired perfusion areas within the DIEP flap based on deoxyHb levels. The results of this study showed a limited added value of TI. Quantitative, post-hoc analysis of ICGA data produced objective and reproducible parameters that enabled the intraoperative detection of arterial and venous congested DIEP flaps. HSI appeared to be a promising technique for postoperative flap perfusion assessment. A diagnostic accuracy study is needed to investigate ICGA and HSI parameters in real-time and demonstrate their clinical benefit.

2.
J Cardiovasc Surg (Torino) ; 64(2): 142-149, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36897207

ABSTRACT

BACKGROUND: Fenestrated endovascular aortic aneurysm repair (FEVAR) is used in pararenal abdominal aortic aneurysms to achieve a durable proximal seal. This study investigated the mid-term course of the proximal fenestrated stent graft (FSG) sealing zone on the first and latest available post-FEVAR computed tomographic angiography (CTA) scan in a single-center series. METHODS: In 61 elective FEVAR patients, the shortest length of circumferential apposition between the FSG and the aortic wall (shortest apposition length [SAL]) was retrospectively assessed on the first and last available postoperative CTA scans. Patient records were reviewed for FEVAR-related procedural details, complications, and reinterventions. RESULTS: The median (interquartile range) time between the FEVAR procedure and the first and last CTA scan was 35 (30-48) days and 2.6 (1.2-4.3) years, respectively. The median (interquartile range) SAL was 38 (29-48) mm, and 44 (34-59) mm on the first and last CTA scans, respectively. During follow-up, the SAL increased >5 mm in 32 patients (52%), and decreased >5 mm in six patients (10%). Reintervention was performed for a type 1a endoleak in one patient. Twelve other patients needed 17 reinterventions for other FEVAR-related complications. CONCLUSIONS: Good mid-term apposition of the FSG in the pararenal aorta was achieved post-FEVAR, and the occurrence of type 1a endoleaks was low. The number of reinterventions was substantial, however, but for reasons other than loss of proximal seal.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Stents/adverse effects , Retrospective Studies , Treatment Outcome , Endovascular Procedures/adverse effects , Aorta/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...