Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
ASAIO J ; 68(9): 1197-1203, 2022 09 01.
Article in English | MEDLINE | ID: mdl-36066356

ABSTRACT

Low flow extracorporeal carbon dioxide removal (ECCO2R) is a promising approach to correct hypercapnic lung failure, facilitate lung protective ventilation in acute respiratory distress syndrome and to possibly prevent the application of invasive ventilation. However, the predominant availability of adult membrane lungs (MLs) at most intensive care units are burdens for low flow ECCO2R that intends to reduce cannula size and promote the mobility of the patients. Herein, in a mock setup, we combine the idea of a low flow ECCO2R and the use of adult MLs by installing a recirculation channel into the circuit and comparing the new setup to an already clinically established setup, "the Homburg lung." Furthermore, to make stronger reference to hypercapnic respiratory failure, we investigate the influence of CO2 partial pressure in blood on CO2 removal of both setups. A linear association between CO2 partial pressure in blood and CO2 removal of the ML in the physiologically relevant range was observed. To understand this linear dependence, a simplified mathematical model was proposed. Our new ECCO2R mock setup combines the idea of a low flow ECCO2R and an adult size ML. It shows a reasonable alternative to the current available low flow setups based on pediatric MLs.


Subject(s)
Respiratory Distress Syndrome , Respiratory Insufficiency , Adult , Carbon Dioxide , Child , Extracorporeal Circulation , Humans , Hypercapnia , Respiration, Artificial , Respiratory Distress Syndrome/therapy
2.
Med Educ Online ; 27(1): 2101417, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35850619

ABSTRACT

As a consequence of the continued Covid-19 lockdown in Germany, in-hospital teaching for medical students was impossible. While lectures and other theoretical training were relatively easily converted into online sessions using platforms such as Moodle, Zoom and Microsoft Teams, this was not the case for practical skills and clinical interventions, such as bronchoscopy or colonoscopy. This study describes a workaround that was implemented at the Saarland University Hospital utilizing virtual reality equipment to convey the impressions of shadowing clinical procedures to the students without physical presence. To achieve this, 3D 180° videos of key clinical interventions of various internal medicine specialities were recorded, cut, and censored. The videos were uploaded to the e-learning YouTube channel of our institution and shared with the students via the private share function. The students could choose whether to use a VR-viewer to watch the videos immersively or to watch them without a viewer on a screen non-immersively. At the end of the course after 1 week, the students completed a questionnaire anonymously focusing on learning-success regarding the presented topics, a self-assessment, and an evaluation of the course. A total of 27 students watched the videos with a VR-Viewer and 74 watched non-immersively. Although the VR-viewer group self-assessed their expertise higher, there was no significant difference between the two groups in the learning-success test score. However, students in the VR-viewer group rated the learning atmosphere, comprehensibility, and overall recommendation of the course significantly higher. They also agreed significantly more to the statement, that they gained a better conception of the presented procedures, and that virtual reality might be an appropriate tool for online teaching. Video-assisted teaching facilitates learning and might be a valuable add-on to conventional teaching.Abbreviations: Covid-19: severe acute respiratory syndrome coronavirus 2; 3D: three-dimensional; 2D: Two-dimensional; VR: virtual reality.


Subject(s)
COVID-19 , Students, Medical , Virtual Reality , Communicable Disease Control , Germany , Hospitals , Humans , Surveys and Questionnaires
3.
Membranes (Basel) ; 12(5)2022 Apr 30.
Article in English | MEDLINE | ID: mdl-35629818

ABSTRACT

Extracorporeal membrane oxygenation (ECMO) has become an important therapeutic approach in the COVID-19 pandemic. The development and research in this field strongly relies on animal models; however, efforts are being made to find alternatives. In this work, we present a new mock circuit for ECMO that allows measurements of the oxygen transfer rate of a membrane lung at full ECMO blood flow. The mock utilizes a large reservoir of heparinized porcine blood to measure the oxygen transfer rate of the membrane lung in a single passage. The oxygen transfer rate is calculated from blood flow, hemoglobin value, venous saturation, and post-membrane arterial oxygen pressure. Before the next measuring sequence, the blood is regenerated to a venous condition with a sweep gas of nitrogen and carbon dioxide. The presented mock was applied to investigate the effect of a recirculation loop on the oxygen transfer rate of an ECMO setup. The recirculation loop caused a significant increase in post-membrane arterial oxygen pressure (paO2). The effect was strongest for the highest recirculation flow. This was attributed to a smaller boundary layer on gas fibers due to the increased blood velocity. However, the increase in paO2 did not translate to significant increases in the oxygen transfer rate because of the minor significance of physically dissolved oxygen for gas transfer. In conclusion, our results regarding a new ECMO mock setup demonstrate that recirculation loops can improve ECMO performance, but not enough to be clinically relevant.

4.
Membranes (Basel) ; 11(6)2021 May 27.
Article in English | MEDLINE | ID: mdl-34072067

ABSTRACT

Extracorporeal carbon dioxide removal (ECCO2R) is an important technique to treat critical lung diseases such as exacerbated chronic obstructive pulmonary disease (COPD) and mild or moderate acute respiratory distress syndrome (ARDS). This study applies our previously presented ECCO2R mock circuit to compare the CO2 removal capacity of circular versus parallel-plated membrane lungs at different sweep gas flow rates (0.5, 2, 4, 6 L/min) and blood flow rates (0.3 L/min, 0.9 L/min). For both designs, two low-flow polypropylene membrane lungs (Medos Hilte 1000, Quadrox-i Neonatal) and two mid-flow polymethylpentene membrane lungs (Novalung Minilung, Quadrox-iD Pediatric) were compared. While the parallel-plated Quadrox-iD Pediatric achieved the overall highest CO2 removal rates under medium and high sweep gas flow rates, the two circular membrane lungs performed relatively better at the lowest gas flow rate of 0.5 L/min. The low-flow Hilite 1000, although overall better than the Quadrox i-Neonatal, had the most significant advantage at a gas flow of 0.5 L/min. Moreover, the circular Minilung, despite being significantly less efficient than the Quadrox-iD Pediatric at medium and high sweep gas flow rates, did not show a significantly worse CO2 removal rate at a gas flow of 0.5 L/min but rather a slight advantage. We suggest that circular membrane lungs have an advantage at low sweep gas flow rates due to reduced shunting as a result of their fiber orientation. Efficiency for such low gas flow scenarios might be relevant for possible future portable ECCO2R devices.

5.
Intensive Care Med Exp ; 8(1): 52, 2020 Sep 11.
Article in English | MEDLINE | ID: mdl-32915322

ABSTRACT

BACKGROUND: Extracorporeal carbon dioxide removal (ECCO2R) is a promising yet limited researched therapy for hypercapnic respiratory failure in acute respiratory distress syndrome and exacerbated chronic obstructive pulmonary disease. Herein, we describe a new mock circuit that enables experimental ECCO2R research without animal models. In a second step, we use this model to investigate three experimental scenarios of ECCO2R: (I) the influence of hemoglobin concentration on CO2 removal. (II) a potentially portable ECCO2R that uses air instead of oxygen, (III) a low-flow ECCO2R that achieves effective CO2 clearance by recirculation and acidification of the limited blood volume of a small dual lumen cannula (such as a dialysis catheter). RESULTS: With the presented ECCO2R mock, CO2 removal rates comparable to previous studies were obtained. The mock works with either fresh porcine blood or diluted expired human packed red blood cells. However, fresh porcine blood was preferred because of better handling and availability. In the second step of this work, hemoglobin concentration was identified as an important factor for CO2 removal. In the second scenario, an air-driven ECCO2R setup showed only a slightly lower CO2 wash-out than the same setup with pure oxygen as sweep gas. In the last scenario, the low-flow ECCO2R, the blood flow at the test membrane lung was successfully raised with a recirculation channel without the need to increase cannula flow. Low recirculation ratios resulted in increased efficiency, while high recirculation ratios caused slightly reduced CO2 removal rates. Acidification of the CO2 depleted blood in the recirculation channel caused an increase in CO2 removal rate. CONCLUSIONS: We demonstrate a simple and cost effective, yet powerful, "in-vitro" ECCO2R model that can be used as an alternative to animal experiments for many research scenarios. Moreover, in our approach parameters such as hemoglobin level can be modified more easily than in animal models.

SELECTION OF CITATIONS
SEARCH DETAIL
...