Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 29
Filter
1.
Laryngoscope Investig Otolaryngol ; 5(6): 1140-1146, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33364405

ABSTRACT

OBJECTIVE: To evaluate the success rate of eustachian tube (ET) occlusion in subtotal petrosectomy relative to the occlusive material used and to the varying protympanum anatomy, by means of standardized alignment of the cochlea-carotid artery relation on computed tomography images. PATIENTS AND METHODS: All cases of subtotal petrosectomy carried out by the same surgeon at a tertiary care referral center were retrospectively evaluated. Only cases with available computed tomography prior to second stage cochlear or middle ear implantation were included. The occlusive material was either muscle tissue or oxidized regenerated cellulose in combination with bone wax. On 3D multiplanar image reconstruction, the varying topographic interrelation of the cochlea and the petrous carotid artery was measured and categorized into two groups: detachment or overlapping. RESULTS: In 9 (31%) of the 29 included cases there was insufficient occlusion of the ET. In none of these cases was an infection of the fat filling in the obliterated cavity observed during the implantation procedure on second stage (average 10 months interval). The failure rate of both occlusion materials was almost the same (using muscle tissue, in 4 (33.3%) of 12 or oxidized regenerated cellulose, in 5 (29.4%) of 17 cases). It was also similar for both materials in each of the anatomic variation groups. CONCLUSIONS: An incomplete occlusion of the ET alone does not appear to lead to an infection of the obliterated cavity. Autologous muscle tissue and oxidized regenerated cellulose had similar rates of ET occlusion failure. The topographical variance of the protympanum appears to have no direct influence on the success of the ET occlusion.

2.
Eur Arch Otorhinolaryngol ; 277(2): 423-438, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31749056

ABSTRACT

PURPOSE: To review types and frequencies of adverse events (AE) associated with bone-conduction hearing implants (BCHIs) and active middle-ear implants (aMEIs) as reported in the literature. METHODS: Cochrane, PubMed, and EMBASE libraries were searched for primary articles in English or German language that reported on adverse events following BCHI or aMEI implantation, included at least five patients and were published between 1996 and 2016. Study characteristics, demographics, and counts of adverse events were tabulated and analyzed within the R statistical programming environment. RESULTS: Following assessment of the reporting quality of adverse events, we present a brief guideline that potentially improves AE reporting in this field of research. For the full dataset, we summarize study-level adverse event frequencies in terms of ratio of events to ears (REE) by AE groups and by device. For a subset of studies, we also report cumulative incidence (risk) for minor- and major adverse-events by device and by device groups. CONCLUSIONS: Data analyzed in this review show that: (1) the reporting quality of adverse events associated with BCHI and aMEIs is often very low; (2) adverse events associated with BCHI and aMEIs are qualitatively different and not equally frequent among devices; (3) state-of-the-art implantable BCHIs and aMEIs are a safe treatment option for hearing loss.


Subject(s)
Cochlear Implants/adverse effects , Hearing Aids/adverse effects , Hearing Loss/surgery , Ossicular Prosthesis/adverse effects , Prosthesis Implantation/adverse effects , Adult , Humans
3.
4.
Audiol Neurootol ; 23(2): 105-115, 2018.
Article in English | MEDLINE | ID: mdl-30196279

ABSTRACT

There is currently no standardized method for reporting audiological, surgical and subjective outcome measures in clinical trials with active middle ear implants (AMEIs). It is often difficult to compare studies due to data incompatibility and to perform meta-analyses across different centres is almost impossible. A committee of ENT and audiological experts from Germany, Austria and Switzerland decided to address this issue by developing new minimal standards for reporting the outcomes of AMEI clinical trials. The consensus presented here aims to provide a recommendation to enable better inter-study comparability.


Subject(s)
Hearing Aids , Hearing Loss, Sensorineural/surgery , Ossicular Prosthesis , Outcome Assessment, Health Care/standards , Austria , Consensus , Germany , Hearing , Hearing Tests , Humans , Switzerland , Treatment Outcome
5.
Article in English | MEDLINE | ID: mdl-29902786

ABSTRACT

OBJECTIVE: To evaluate possible increases in bone conduction (BC) hearing thresholds in patients undergoing subtotal petrosectomy (SP) with fat obliteration and blind sac closure of the outer ear canal and subsequent round window vibroplasty. PATIENTS AND INTERVENTIONS: Between 1997 and 2013, 43 patients (45 ears) with combined hearing loss and recurrent chronic otitis or status post formation of a radical cavity underwent SP around 6 months prior to implantation of a Vibrant SoundbridgeTM. Pure tone audiograms (0.5, 1, 1.5, 2, 3, 4, and 6 kHz) prior to SP, after SP, prior to implantation, after implantation, and at first fitting around 5 weeks after implantation were collected and statistically analyzed. RESULTS: The comparison between BC thresholds before SP and at first fitting showed an overall decline during the two-step procedure between 2.8 and 6 dB that was significant (p < 0.05, Student t test) at 2, 3, 4, and 6 kHz. CONCLUSION: In some cases, SP is the only way to eradicate chronic otitis and to achieve a suitable environment for the implantation of active middle ear implants. The present data demonstrate a relatively small but significant decline in BC thresholds throughout the whole procedure. Knowledge of its extent is mandatory for a correct indication for later implantation of a Vibrant SoundbridgeTM.


Subject(s)
Bone Conduction , Hearing Loss, Mixed Conductive-Sensorineural/surgery , Ossicular Prosthesis , Ossicular Replacement/methods , Petrous Bone/surgery , Round Window, Ear/surgery , Audiometry , Hearing Aids , Hearing Loss, Mixed Conductive-Sensorineural/rehabilitation , Humans , Middle Aged
6.
Otol Neurotol ; 37(6): 685-91, 2016 07.
Article in English | MEDLINE | ID: mdl-27093021

ABSTRACT

OBJECTIVES: In conductive, mixed hearing losses and single-sided-deafness bone-anchored hearing aids are a well-established treatment. The transcutaneous transmission across the intact skin avoids the percutaneous abutment of a bone-anchored device with the usual risk of infections and requires less care.In this study, the audiological results of the Bonebridge transcutaneous bone conduction implant (MED-EL) are compared to the generally used percutaneous device BP100 (Cochlear Ltd., Sydney, Australia). METHODS: Ten patients implanted with the transcutaneous hearing implant were compared to 10 matched patients implanted with a percutaneous device. Tests included pure-tone AC and BC thresholds and unaided and aided sound field thresholds. Speech intelligibility was determined in quiet using the Freiburg monosyllable test and in noise with the Oldenburg sentence test (OLSA) in sound field with speech from the front (S0). The subjective benefit was assessed with the Abbreviated Profile of Hearing Aid Benefit. RESULTS: In comparison with the unaided condition there was a significant improvement in aided thresholds, word recognition scores (WRS), and speech reception thresholds (SRT) in noise, measured in sound field, for both devices. The comparison of the two devices revealed a minor but not significant difference in functional gain (Bonebridge: PTA = 27.5 dB [mean]; BAHA: PTA = 26.3 dB [mean]). No significant difference between the two devices was found when comparing the improvement in WRSs and SRTs (Bonebridge: improvement WRS = 80% [median], improvement SRT = 6.5 dB SNR [median]; BAHA: improvement WRS = 77.5% [median], BAHA: improvement SRT = 6.9 dB SNR [median]). CONCLUSION: Our data show that the transcutaneous bone conduction hearing implant is an audiologically equivalent alternative to percutaneous bone-anchored devices in conductive hearing loss with a minor sensorineural hearing loss component.


Subject(s)
Hearing Aids , Hearing Loss, Conductive/surgery , Hearing , Speech Intelligibility , Australia , Bone Conduction , Hearing Tests , Suture Anchors
7.
Eur Arch Otorhinolaryngol ; 273(11): 3641-3646, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27015665

ABSTRACT

The objective of the study was to examine the impact of the surgical wound closure technique as protection of the obliterated tympanomastoid cavity on the revision surgery rate after subtotal petrosectomy (SP). This is a retrospective case series conducted in a tertiary care referral center. 199 patients (212 ears) with recurrent chronic otitis media underwent SP followed by tympanomastoid obliteration with abdominal fat at a single tertiary referral center between 2005 and 2015. 124 SP were carried out without (group A), 74 with temporalis muscle flap (group B) and 14 with reinforcing material like polydioxanone foil or bovine pericardium or allogenic fascia lata (group C) for wound closure. The evaluated follow-up was either until the scheduled device implantation or 6 months postoperatively. We assessed the rate of postoperative wound healing disorder with revision surgery according to the surgical technique for closure of the obliterated cleft. Revision surgery due to impaired wound healing was necessary in 16 % of the total cases (group A: 18.5 %, group B: 10.8 %, group C: 21.4 %). Further analysis concerning the dehiscent area in both sites (retroauricular and blind sac of the external auditory canal) was conducted and discussed. There was no significant difference observed in the rate of revision surgery between the three groups. The wound healing process after SP is determined by many factors and cannot be significantly influenced solely by reinforcing tissue like the temporalis muscle flap or supporting materials.


Subject(s)
Otitis Media/surgery , Otologic Surgical Procedures , Wound Closure Techniques , Adolescent , Adult , Aged , Aged, 80 and over , Animals , Cattle , Child , Chronic Disease , Female , Follow-Up Studies , Humans , Male , Middle Aged , Reoperation/statistics & numerical data , Retrospective Studies , Surgical Wound , Treatment Outcome , Wound Healing , Young Adult
8.
Hear Res ; 340: 185-190, 2016 10.
Article in English | MEDLINE | ID: mdl-26836967

ABSTRACT

The new implantable hearing system Codacs™ was designed to close the treatment gap between active middle ear implants and cochlear implants in cases of severe-to-profound mixed hearing loss. The Codacs™ actuator is attached to conventional stapes prosthesis during the implantation and thereby provides acoustical stimulation through a stapedotomy to the cochlea. Cochlear implants (CIs) on the other hand are an established treatment option for profoundly deaf patients including mixed hearing losses that are possible candidates for the Codacs™. In this retrospective study, we compared the clinical outcome of 25 patients with the Codacs™ (≥3 month post-activation) to 54 CI patients (two years post-activation) with comparable pre-operative bone conduction (BC) thresholds that were potential candidates for both categories of devices. The word recognition score (Freiburg monosyllables test) in quiet was significantly (p < 0.05) better in the Codacs™ than in the corresponding CI patients for average pre-operative bone conduction below 60 dB HL and equal in patients with a pre-operative BC PTA between 60 and 70 dB HL. Speech in noise intelligibility (HSM sentences test at +10 dB SNR) was significantly (p < 0.001) better in Codacs™ (80% median) than in CI patients (25% median) in all tested groups. Our results indicate for patients with sufficient cochlear reserve that speech intelligibility in noise with the Codacs™ hearing implant is significantly better than with a CI. Further, results in Codacs™ were better predictable, encouraging the extension of the indication to patients with less cochlear reserve than reported here.


Subject(s)
Acoustic Stimulation/methods , Cochlea/surgery , Cochlear Implants , Hearing Loss, Mixed Conductive-Sensorineural/therapy , Adult , Aged , Auditory Threshold/physiology , Cochlear Implantation , Female , Humans , Male , Middle Aged , Noise , Ossicular Prosthesis , Retrospective Studies , Speech Intelligibility , Speech Perception/physiology , Young Adult
9.
Eur Arch Otorhinolaryngol ; 273(6): 1387-91, 2016 Jun.
Article in English | MEDLINE | ID: mdl-26092235

ABSTRACT

Subtotal petrosectomy combined with obliteration of the tympanomastoid is a standard procedure to treat temporal bones in patients with radical cavity and chronic infections. Currently, patients with profound-to-severe sensorineural hearing loss are often fitted with cochlear implants. In the case of profound mixed hearing loss, active middle ear implants have been used successfully. The new Codacs™ system provides an effective treatment for patients with severe-to-profound mixed hearing loss; however, only aerated middle ears have been treated with this device. The question arises whether the Codacs™ can be implanted in patients with radical cavity or ears with chronic otorrhea. Of the 41 patients who were implanted with the Codacs™ at the department, 4 received the device after subtotal petrosectomy and obliteration with abdominal fat. Clinical and audiological results were assessed. The device was implanted without any complications in the obliterated subtotal petrosectomy. The preliminary results of the first two patients showed stable bone conduction thresholds and indicated improved speech intelligibility in quiet and noise. Implanting the Codacs™ device after subtotal petrosectomy and obliteration with abdominal fat has been proven to be a feasible and suitable procedure for patients with radical cavity or chronic otorrhea. The speech intelligibility outcome directly after activation was comparable to patients with aerated middle ears.


Subject(s)
Cochlear Implantation/methods , Cochlear Implants , Hearing Loss, Mixed Conductive-Sensorineural/rehabilitation , Otitis Media , Petrous Bone/surgery , Abdominal Fat/transplantation , Aged , Chronic Disease , Ear Diseases/surgery , Ear, Middle/surgery , Female , Humans , Male , Mastoid/surgery , Middle Aged , Ossicular Prosthesis , Speech Intelligibility , Temporal Bone/surgery , Treatment Outcome
10.
Audiol Neurootol ; 20(2): 136-146, 2015.
Article in English | MEDLINE | ID: mdl-25824716

ABSTRACT

OBJECTIVES: The principal aim of this study was to assess the safety and effectiveness of the middle ear implant Vibrant Soundbridge (VSB) in patients with moderate-to-severe sensorineural hearing loss up to a mean (± standard deviation) duration of 11.1 ± 2.1 years (min. = 8.2, max. = 13.9, n = 16) after the intervention. DESIGN: This was a retrospective, single-subject repeated-measurements study over a long-term period. A total of 104 German-speaking adults (for 122 implants) were included in this study (54 male, 50 female). The mean age at implantation was 54.5 years (min. = 19.0, max. = 80.4). Audiological outcome and speech intelligibility were assessed in all VSB patients at different time points in non-overlapping groups. RESULTS: Bone conduction (BC) thresholds were preserved after the implantation and no indication was found of an increase over time of the small air-bone gaps introduced by the implantation. BC and air conduction thresholds worsened similarly in both implanted and non-implanted ears over time. The decrease in audiological benefit provided by the VSB was moderate and the Word Recognition Score in quiet conditions at 65 dB SPL was still largely improved with the VSB in the longest observed group. CONCLUSIONS: These results confirm that the VSB does not affect the integrity of the inner/middle ear and is still beneficial in long-term follow-up.


Subject(s)
Incus/surgery , Ossicular Prosthesis , Ossicular Replacement/methods , Adult , Aged , Aged, 80 and over , Audiometry, Pure-Tone , Bone Conduction , Female , Hearing Loss, Sensorineural , Humans , Longitudinal Studies , Male , Middle Aged , Retrospective Studies , Severity of Illness Index , Speech Perception , Treatment Outcome , Young Adult
11.
Int J Audiol ; 54(6): 391-400, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25735204

ABSTRACT

OBJECTIVE: To compare audiological outcomes in mild-to-moderate mixed hearing loss patients treated with a bone-anchored hearing aid or an active middle-ear implant. Analysis aimed to refine criteria used in preoperative selection of implant type. DESIGN: Retrospective comparative analysis of audiological data. Follow-up time ranged between 0.55 and 8.8 years. STUDY SAMPLE: For detailed comparative analysis, 12 patients (six in each group) with comparable bone conduction thresholds and similar clinical characteristics were selected. A larger cohort of 48 patient files were used to evaluate overall audiological indication criteria (24 per group). RESULTS: In free-field tone audiometry, Baha patients showed mean aided thresholds between 40-48 dB, whereas hearing thresholds for VSB patients were 25-43 dB. Baha and VSB users had mean WRS of 56% and 82%, respectively, at 65 dB. Better speech understanding in noise was seen with the VSB. CONCLUSION: Analysis of the main cohort (n = 48) showed that treatment with round window vibroplasty leads to better hearing performance than treatment with a bone-anchored hearing device, if the bone conduction pure-tone average (0.5 to 4 kHz) is poorer than 35 dB HL. Audiological analysis in the smaller comparative analysis showed similar findings.


Subject(s)
Acoustic Stimulation/methods , Correction of Hearing Impairment/methods , Hearing Aids , Hearing Loss, Mixed Conductive-Sensorineural/rehabilitation , Ossicular Prosthesis , Acoustic Stimulation/instrumentation , Adult , Aged , Audiometry , Auditory Threshold , Bone Conduction/physiology , Correction of Hearing Impairment/instrumentation , Female , Humans , Male , Middle Aged , Noise , Retrospective Studies , Round Window, Ear/physiopathology , Speech Perception , Young Adult
12.
Otol Neurotol ; 35(9): 1615-20, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25203563

ABSTRACT

OBJECTIVE: To compare surgical methods, functional gain, and speech discrimination using two different coupling methods for an active middle ear implant. Of several couplers enabling placement of the active element at various locations, two function directly at a cochlear membrane, bypassing a missing or malformed ossicular chain. This study evaluates whether either of these methods is more beneficial. STUDY DESIGN: Retrospective case review. SETTING: ENT surgical clinic. PATIENTS: Forty-seven German-speaking patients with moderate to severe mixed hearing loss. INTERVENTIONS: Records of patients implanted with either a round window (RW) or oval window (OW) coupler and active implant were examined. Preoperative and postoperative bone and air-conduction thresholds, auditory gain, and speech perception were compared. MAIN OUTCOME MEASURES: Functional gain, Freiburger monosyllables in quiet. RESULTS: The range of hearing benefit shown by functional gain in patients implanted with the RW coupler (median) was between 22.5 dB (at 0.25 kHz) and 52.5 dB (2 and 3 kHz). In the OW group, improvement was similar, ranging from 21 dB (at 8 kHz) to 50 dB (1 and 2 kHz). Patients in both groups showed a similar improvement in speech recognition. Median preoperative unaided word recognition was 0% at 60 dB HL for both patient groups, improved postoperatively in both groups to median 85% correct at 65 dB HL and 95% at 80 dB HL. CONCLUSION: Placement of an active middle ear implant using the RW and the OW coupler was found to be safe, although the surgical methods differ. Safety and efficacy of both couplers present no significant differences.


Subject(s)
Ear, Middle/surgery , Hearing Loss/surgery , Ossicular Prosthesis , Otologic Surgical Procedures/instrumentation , Adolescent , Adult , Aged , Female , Hearing Aids , Hearing Tests , Humans , Male , Middle Aged , Otologic Surgical Procedures/methods , Retrospective Studies , Speech Perception , Titanium , Treatment Outcome , Young Adult
13.
Hear Res ; 314: 1-9, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24727490

ABSTRACT

OBJECTIVE: Mechanical stimulation of the round window (RW) of the cochlea is successfully done with the Vibrant Soundbridge (Med-El), but clinical outcomes show a substantial degree of variability. One source of variability is variation in the static force applied by the stimulator to the round window (Maier et al., 2013). In this study we investigated other sources of variability by maintaining a constant pre-load testing the effect of a coupler device and the interposition of soft tissue between the stimulator and the RW. STUDY DESIGN: Experimental. METHODS: The stapes footplate displacement produced by stimulation of the round window was determined in fresh human temporal bones. The response to sound and actuator stimulation was measured with a Laser Doppler Velocimeter at the stapes footplate. The RW was stimulated by a Floating Mass Transducer (FMT) with/without (1) an additional RW coupler (supplied by the manufacturer), and (2) the interposition of TUTOPATCH between the stimulator and the RW, while maintaining a pre-load of ∼1.96 mN. RESULTS: In 8 temporal bones with normal stapes footplate response to sound, we found an average 11.9 dB increase (500 Hz-2 kHz) under controlled conditions by using the coupler together with the interposition. The increase was statistically significant at 500 Hz (p < 0.01). Additionally, the coupler/interposition combination reduced the variability between experiments (FMT alone SD = 10.9 dB; FMT with TUTOPATCH & coupler: SD = 3.4 dB @ 500 Hz) and increased the repeatability. CONCLUSION: At controlled static force an improved output level, inter-subject variability and repeatability were found by using a coupler/TUTOPATCH combination in RW stimulation with the FMT. The high variability found in clinical experience is not solely due to inter-subject variability, but to coupling conditions and can be optimized further.


Subject(s)
Ossicular Prosthesis , Prosthesis Design , Round Window, Ear/physiology , Stapes/physiology , Temporal Bone/physiology , Cadaver , Humans , Materials Testing , Reproducibility of Results , Signal Processing, Computer-Assisted , Signal-To-Noise Ratio , Stress, Mechanical , Transducers , Vibration
14.
Otol Neurotol ; 34(9): 1711-8, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24232068

ABSTRACT

OBJECTIVE: Patients with moderate-to-severe mixed hearing losses (MHLs) are hard to provide sufficient benefit with currently available conventional hearing aids. Here, the long-term safety of a direct acoustic cochlear stimulator (DACS) and the effectiveness compared with conventional "high-performance" hearing aids were investigated. STUDY DESIGN: Prospective, within patient reference, nonrandomized, interventional multicenter clinical study performed at these 3 centers: Medical University Hannover, University of Heidelberg, and Helios Hospital Krefeld. PATIENTS AND INTERVENTION: Ten otosclerosis patients with severe-to-profound MHL were preoperatively fitted with state-of-the-art conventional hearing aids (HA). After 2 months of testing conventional HA, 9 of the patients decided to be implanted with a DACS. MAIN OUTCOME MEASURES: Air conduction (AC) and bone conduction (BC) aided and unaided thresholds, speech discrimination before and after implantation and at 3, 6, and 12 months after activation. The subjective benefit was assessed by the Abbreviated Profile of Hearing Aid Benefit (APHAB). RESULTS: Preoperative hearing thresholds were preserved over the 12 month observation time after activation. Average functional gain (0.5-4 kHz) achieved with conventional HA was 47 dB compared with 56 dB with the DACS. Speech-in-noise tests revealed a lower SNR for DACS (3.1 dB) than for the HA (6.6 dB) and patients were more satisfied with the DACS. CONCLUSION: The DACS significantly improved hearing, speech intelligibility, and satisfaction in patients with a severe-to-profound mixed hearing loss and can be considered a safe and useful alternative to conventional hearing aids.


Subject(s)
Auditory Threshold/physiology , Hearing Aids , Hearing Loss, Mixed Conductive-Sensorineural/rehabilitation , Speech Perception/physiology , Acoustic Stimulation , Adult , Aged , Bone Conduction/physiology , Female , Hearing Loss, Mixed Conductive-Sensorineural/physiopathology , Humans , Male , Middle Aged , Prospective Studies
15.
Otol Neurotol ; 34(7): 1181-5, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23921921

ABSTRACT

OBJECTIVE: Implanting active middle ear implants (AMEI) at the round window has become a standard procedure to restore hearing for patients with moderate inner ear or mixed hearing loss. The round window (RW)-Coupler was developed as an alternative coupling aid to fit smaller RW diameters and require less drilling in the RW niche. The question arises whether using the RW-Coupler is useful and a safe procedure compared with the nonuse of the RW-Coupler MATERIALS AND METHODS: Forty-nine German-speaking patients were implanted with either a RW-Coupler attached to an AMEI floating mass transducer (FMT) or without coupler. They were evaluated preoperatively and postoperatively for bone and air conduction thresholds with and without the implant, as well as speech perception tests. RESULTS: Bone conduction thresholds remained stable preoperatively and postoperatively. The patient's functional gain was slightly better with the RW-Coupler. Focusing on the average speech perception performances, both groups presented an improvement of speech perception above 80% at 65 dB HL. CONCLUSION: RW-Coupler-Vibroplasty was found to be a safe procedure, which produced good results in this group of patients with mixed hearing loss.


Subject(s)
Cochlear Implantation/methods , Cochlear Implants , Hearing Loss/surgery , Round Window, Ear/surgery , Adolescent , Adult , Aged , Audiometry, Pure-Tone , Auditory Threshold/physiology , Bone Conduction/physiology , Child , Cochlear Implantation/adverse effects , Cochlear Implants/adverse effects , Female , Hearing Loss, Mixed Conductive-Sensorineural/surgery , Humans , Male , Middle Aged , Retrospective Studies , Speech Discrimination Tests , Speech Perception , Treatment Outcome , Young Adult
16.
Otol Neurotol ; 34(7): 1215-25, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23921930

ABSTRACT

OBJECTIVE: To confirm the clinical efficacy and safety of a direct acoustic cochlear implant. STUDY DESIGN: Prospective multicenter study. SETTING: The study was performed at 3 university hospitals in Europe (Germany, The Netherlands, and Switzerland). PATIENTS: Fifteen patients with severe-to-profound mixed hearing loss because of otosclerosis or previous failed stapes surgery. INTERVENTION: Implantation with a Codacs direct acoustic cochlear implant investigational device (ID) combined with a stapedotomy with a conventional stapes prosthesis MAIN OUTCOME MEASURES: Preoperative and postoperative (3 months after activation of the investigational direct acoustic cochlear implant) audiometric evaluation measuring conventional pure tone and speech audiometry, tympanometry, aided thresholds in sound field and hearing difficulty by the Abbreviated Profile of Hearing Aid Benefit questionnaire. RESULTS: The preoperative and postoperative air and bone conduction thresholds did not change significantly by the implantation with the investigational Direct Acoustic Cochlear Implant. The mean sound field thresholds (0.25-8 kHz) improved significantly by 48 dB. The word recognition scores (WRS) at 50, 65, and 80 dB SPL improved significantly by 30.4%, 75%, and 78.2%, respectively, after implantation with the investigational direct acoustic cochlear implant compared with the preoperative unaided condition. The difficulty in hearing, measured by the Abbreviated Profile of Hearing Aid Benefit, decreased by 27% after implantation with the investigational direct acoustic cochlear implant. CONCLUSION: Patients with moderate-to-severe mixed hearing loss because of otosclerosis can benefit substantially using the Codacs investigational device.


Subject(s)
Cochlear Implants , Hearing Loss, Mixed Conductive-Sensorineural/surgery , Acoustic Impedance Tests , Aged , Audiometry , Audiometry, Pure-Tone , Auditory Threshold , Bone Conduction , Cochlear Implantation/methods , Cochlear Implants/adverse effects , Female , Hearing Loss, Mixed Conductive-Sensorineural/physiopathology , Humans , Male , Middle Aged , Otologic Surgical Procedures , Prospective Studies , Software , Speech Perception , Stapes Surgery , Treatment Outcome
17.
Hear Res ; 301: 115-24, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23276731

ABSTRACT

The Direct Acoustic Cochlea Stimulator Partial Implant (DACS PI, Phonak Acoustic Implants SA, Switzerland) is intended to stimulate the cochlea by a conventional stapedotomy piston that is crimped onto the DACS PI artificial incus. An alternative approach to the round window (RW) is successfully done with other devices, having the advantage of being also independent of the existence of middle ear structure (e.g. ossicles). Here the possibility of stimulating the RW with the DACS actuator is investigated including the impact of static force on sound transmission to the cochlea. The maximum equivalent sound pressure output with RW stimulation was determined experimentally in fresh human temporal bones. Experiments were performed in analogy to the ASTM standard (F2504.24930-1) method for the output determination of implantable middle ear hearing devices (IMEHDs) in human cadaveric temporal bones (TBs). ASTM compliant temporal bones were stimulated with a prosthesis having a spherical tip (∅0.5 mm) attached to the actuator. The stimulation was performed perpendicular to the round window membrane (RWM) at varying position relative to the RW and the resulting static force on the RW membrane was determined. At each position the displacement output of the DACS PI actuator and the stapes footplate (SFP) vibration in response to actuator stimulation was measured with a Laser Doppler Velocimeter (LDV). By comparison of the achieved output at the stapes footplate in response to sound and transducer stimulation the equivalent sound pressure level at the tympanic membrane at 1Vrms input voltage was calculated assuming that the SFP displacement in both conditions is a measure of perceived loudness, as it is done in the ASTM standard. Ten TB preparations within the acceptance range of the ASTM standard were used for analysis. The actuator driven stapes footplate displacement amplitude as well as the resulting equivalent sound pressure level was highly dependent on the static force applied to the RW. The sound transfer efficiency from the RW to the stapes footplate increased monotonically with increasing static load. At a moderate static force load (approx. 3.9 mN) the obtained average sound equivalent sound pressure level was 102-120 eq. dB SPL @ nominally 1Vrms input for frequencies ≤4 kHz. At higher frequencies (6-10 kHz) the achieved output dropped to ∼90 dB SPL. This output was obtained at loading conditions compatible with the actuator safe operating range, although it was possible to increase the output further by increasing the static force load. Our results demonstrate for a first time that static force applied to the RW is crucial for sound transmission efficiency. Further we could show that RW stimulation with the DACS PI actuator is possible having a maximum output that is sufficient to treat moderate and pronounced sensorineural hearing losses (SNHL). This article is part of a Special Issue entitled "MEMRO 2012".


Subject(s)
Acoustic Stimulation , Acoustics , Cochlea/physiology , Ear Ossicles/physiology , Ear, Middle/physiology , Round Window, Ear/physiology , Stapes/physiology , Cadaver , Humans , Ossicular Prosthesis , Pressure , Prosthesis Design , Round Window, Ear/anatomy & histology , Sound , Stress, Mechanical , Temporal Bone/anatomy & histology , Temporal Bone/physiology
18.
Eur Arch Otorhinolaryngol ; 270(4): 1243-8, 2013 Mar.
Article in English | MEDLINE | ID: mdl-22829158

ABSTRACT

The aim of this study was to describe the outcome and possible complications of subtotal petrosectomy (SP) for Vibrant Soundbridge (VSB) device surgery in a tertiary referral center. A secondary objective was the evaluation of hearing results in a subgroup of subjects who received the VSB device. Between 2009 and early 2011, 22 adult subjects with chronic otitis media (COM) underwent a SP, blind sac closure of the external auditory canal and abdominal fat obliteration to facilitate the application of an active middle ear implant (AMEI) in a staged procedure. Indications consisted of mixed hearing loss after previous tympanomastoplasty and failure of hearing rehabilitation with a hearing aid or bone conduction device in COM. Pre- and postoperative pure-tone audiograms were analyzed in respect to deterioration of inner ear function, unaided and aided (hearing aid, bone-anchored hearing aid and VSB) speech audiograms were compared to verify improvements in communications skills and functional gains. Incidence and type of complications were reviewed. No significant change was observed regarding mean bone conduction thresholds after the first stage procedure. Some minor wound healing problems were noted. Speech perception using the VSB (n = 16) showed a mean aided speech discrimination at 65-dB SPL of 75 % [standard deviation (SD) 28.7], at 80-dB SPL of 90 % (SD 25.1). Our results suggest that for selected patients with open mastoid cavities and chronic middle ear disease, SP with abdominal fat obliteration is an effective and safe technique to facilitate safe AMEI placement.


Subject(s)
Cholesteatoma, Middle Ear/surgery , Hearing Loss, Mixed Conductive-Sensorineural/surgery , Ossicular Prosthesis , Otitis Media/surgery , Petrous Bone/surgery , Prosthesis Design , Adult , Aged , Auditory Threshold , Chronic Disease , Female , Hearing Aids , Humans , Male , Middle Aged , Retrospective Studies , Speech Discrimination Tests , Young Adult
19.
Laryngoscope ; 122(11): 2524-8, 2012 Nov.
Article in English | MEDLINE | ID: mdl-22965860

ABSTRACT

OBJECTIVES/HYPOTHESIS: Most existing studies about infantile Bartter syndrome (BS) have focused on renal function, and deafness has not been closely studied. Our objective was to evaluate the treatment of hearing impairment in children with infantile BS and analyze relevant, unexplored issues. STUDY DESIGN: Retrospective chart review. METHODS: The present study was conducted in a tertiary referral center over a 20-year period involving children with infantile BS. Demographic factors, general health status, genetic information, features of hearing loss, and the outcome of cochlear implantation as determined mainly by the categories of auditory performance (CAP), as well as imaging of the temporal bones, were evaluated. RESULTS: Six children with infantile BS were identified, four girls and two boys. One child had terminal renal insufficiency and one had undergone kidney transplantation; all children had several hospital admissions due to renal dysfunction. Sensorineural hearing loss was congenital, bilateral, and profound in all children. Five patients were treated with cochlear implants resulting in improved speech perception and development without any exceptional performance (CAP scores, 4-6), mainly because of the delayed treatment and the comorbidities. Anatomic ear anomalies were not observed in any case. CONCLUSIONS: Hearing loss in children with infantile BS is congenital and profound but not related to inner ear malformations. Although cochlear implantation results in certain benefits, general health status and delayed referral to cochlear implant centers have a negative impact on speech perception and development.


Subject(s)
Bartter Syndrome/complications , Hearing Loss/etiology , Hearing Loss/therapy , Cochlear Implants , Female , Hearing Loss/pathology , Humans , Infant , Magnetic Resonance Imaging , Male , Retrospective Studies , Tomography, X-Ray Computed , Treatment Outcome
20.
Otol Neurotol ; 33(5): 804-9, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22699990

ABSTRACT

OBJECTIVE: To date, all the Vibrant Soundbridge (VSB) applications have managed to stimulate the inner ear indirectly. Our objective was to present a new VSB application for direct inner ear stimulation. STUDY DESIGN: Prospective cohort study. SETTINGS: Tertiary, referral center PATIENTS: Three patients with previous middle ear surgery and moderate-to-severe ipsilateral, mixed hearing loss. INTERVENTIONS: Oval window membrane vibroplasty (OWMV) for direct acoustic cochlear stimulation. A total ossicular replacement prosthesis (TORP) was attached to the floating mass transducer (FMT). Then, the stapes footplate was perforated, and the tip of the FMT-TORP assembly was advanced approximately 1 mm into the inner ear. A silicon ring was placed around the TORP's tip to prevent it from slipping deeper into the inner ear. MAIN OUTCOME MEASURE: Audiologic assessment involving pure-tone audiometry, aided and unaided free-field audiometry, Freiburg monosyllabic word test, and registration of any complications. RESULTS: OWMV resulted in an average functional hearing gain of 36.1 dB (range, 24.2-47.5 dB). Although the greatest amplification was observed in the higher frequencies, there also was a significant improvement in the lower frequencies. The surgery was not related to any difficulties; vertigo, inner ear trauma, or further complications did not occur. CONCLUSION: We present a new method for direct acoustic cochlear stimulation using an active middle ear implant. The preliminary results show that OWMV is a promising and safe option for treating moderate and severe hearing loss, even in challenging cases with previous middle ear operations or fixed stapes footplate.


Subject(s)
Ear, Middle/surgery , Hearing Loss, Conductive/surgery , Hearing Loss, Mixed Conductive-Sensorineural/surgery , Ossicular Prosthesis , Ossicular Replacement , Oval Window, Ear/surgery , Acoustic Stimulation , Audiometry , Ear, Middle/physiopathology , Female , Hearing Loss, Conductive/physiopathology , Hearing Loss, Mixed Conductive-Sensorineural/physiopathology , Humans , Male , Middle Aged , Prospective Studies , Stapes/physiopathology , Stapes Surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...