Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Wearable Technol ; 5: e1, 2024.
Article in English | MEDLINE | ID: mdl-38510985

ABSTRACT

Telerehabilitation and robotics, either traditional rigid or soft, have been extensively studied and used to improve hand functionality after a stroke. However, a limited number of devices combined these two technologies to such a level of maturity that was possible to use them at the patients' home, unsupervised. Here we present a novel investigation that demonstrates the feasibility of a system that integrates a soft inflatable robotic glove, a cloud-connected software interface, and a telerehabilitation therapy. Ten chronic moderate-to-severe stroke survivors independently used the system at their home for 4 weeks, following a software-led therapy and being in touch with occupational therapists. Data from the therapy, including automatic assessments by the robot, were available to the occupational therapists in real-time, thanks to the cloud-connected capability of the system. The participants used the system intensively (about five times more movements per session than the standard care) for a total of more than 8 hr of therapy on average. We were able to observe improvements in standard clinical metrics (FMA +3.9 ± 4.0, p < .05, COPM-P + 2.5 ± 1.3, p < .05, COPM-S + 2.6 ± 1.9, p < .05, MAL-AOU +6.6 ± 6.5, p < .05) and range of motion (+88%) at the end of the intervention. Despite being small, these improvements sustained at follow-up, 2 weeks after the end of the therapy. These promising results pave the way toward further investigation for the deployment of combined soft robotic/telerehabilitive systems at-home for autonomous usage for stroke rehabilitation.

2.
Sensors (Basel) ; 23(12)2023 Jun 18.
Article in English | MEDLINE | ID: mdl-37420857

ABSTRACT

The ability to count finger and wrist movements throughout the day with a nonobtrusive, wearable sensor could be useful for hand-related healthcare applications, including rehabilitation after a stroke, carpal tunnel syndrome, or hand surgery. Previous approaches have required the user to wear a ring with an embedded magnet or inertial measurement unit (IMU). Here, we demonstrate that it is possible to identify the occurrence of finger and wrist flexion/extension movements based on vibrations detected by a wrist-worn IMU. We developed an approach we call "Hand Activity Recognition through using a Convolutional neural network with Spectrograms" (HARCS) that trains a CNN based on the velocity/acceleration spectrograms that finger/wrist movements create. We validated HARCS with the wrist-worn IMU recordings obtained from twenty stroke survivors during their daily life, where the occurrence of finger/wrist movements was labeled using a previously validated algorithm called HAND using magnetic sensing. The daily number of finger/wrist movements identified by HARCS had a strong positive correlation to the daily number identified by HAND (R2 = 0.76, p < 0.001). HARCS was also 75% accurate when we labeled the finger/wrist movements performed by unimpaired participants using optical motion capture. Overall, the ringless sensing of finger/wrist movement occurrence is feasible, although real-world applications may require further accuracy improvements.


Subject(s)
Stroke , Wearable Electronic Devices , Humans , Wrist , Upper Extremity , Movement , Stroke/diagnosis , Delivery of Health Care
3.
Sensors (Basel) ; 22(18)2022 Sep 14.
Article in English | MEDLINE | ID: mdl-36146287

ABSTRACT

After stroke, many people substantially reduce use of their impaired hand in daily life, even if they retain even a moderate level of functional hand ability. Here, we tested whether providing real-time, wearable feedback on the number of achieved hand movements, along with a daily goal, can help people increase hand use intensity. Twenty participants with chronic stroke wore the Manumeter, a novel magnetic wristwatch/ring system that counts finger and wrist movements. We randomized them to wear the device for three weeks with (feedback group) or without (control group) real-time hand count feedback and a daily goal. Participants in the control group used the device as a wristwatch, but it still counted hand movements. We found that the feedback group wore the Manumeter significantly longer (11.2 ± 1.3 h/day) compared to the control group (10.1 ± 1.1 h/day). The feedback group also significantly increased their hand counts over time (p = 0.012, slope = 9.0 hand counts/hour per day, which amounted to ~2000 additional counts per day by study end), while the control group did not (p-value = 0.059; slope = 4.87 hand counts/hour per day). There were no significant differences between groups in any clinical measures of hand movement ability that we measured before and after the feedback period, although several of these measures improved over time. Finally, we confirmed that the previously reported threshold relationship between hand functional capacity and daily use was stable over three weeks, even in the presence of feedback, and established the minimal detectable change for hand count intensity, which is about 30% of average daily intensity. These results suggest that disuse of the hand after stroke is temporarily modifiable with wearable feedback, but do not support that a 3-week intervention of wearable hand count feedback provides enduring therapeutic gains.


Subject(s)
Stroke Rehabilitation , Stroke , Wearable Electronic Devices , Feedback , Hand , Humans , Stroke/therapy , Stroke Rehabilitation/methods , Upper Extremity
4.
Sensors (Basel) ; 21(4)2021 Feb 22.
Article in English | MEDLINE | ID: mdl-33671505

ABSTRACT

There are few wearable sensors suitable for daily monitoring of wrist and finger movements for hand-related healthcare applications. Here, we describe the development and validation of a novel algorithm for magnetically counting hand movements. We implemented the algorithm on a wristband that senses magnetic field changes produced by movement of a magnetic ring worn on the finger (the "Manumeter"). The "HAND" (Hand Activity estimated by Nonlinear Detection) algorithm assigns a "HAND count" by thresholding the real-time change in magnetic field created by wrist and/or finger movement. We optimized thresholds to achieve a HAND count accuracy of ~85% without requiring subject-specific calibration. Then, we validated the algorithm in a dexterity-impaired population by showing that HAND counts strongly correlate with clinical assessments of upper extremity (UE) function after stroke. Finally, we used HAND counts to test a recent hypothesis in stroke rehabilitation that real-world UE hand use increases only for stroke survivors who achieve a threshold level of UE functional capability. For 29 stroke survivors, HAND counts measured at home did not increase until the participants' Box and Blocks Test scores exceeded ~50% normal. These results show that a threshold-based magnetometry approach can non-obtrusively quantify hand movements without calibration and also verify a key concept of real-world hand use after stroke.


Subject(s)
Algorithms , Hand , Stroke Rehabilitation , Stroke , Calibration , Female , Humans , Male , Movement , Stroke/diagnosis , Wrist
SELECTION OF CITATIONS
SEARCH DETAIL
...