Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Vision Res ; 137: 61-79, 2017 08.
Article in English | MEDLINE | ID: mdl-28688907

ABSTRACT

The visual prosthesis (or "bionic eye") has become a reality but provides a low resolution view of the world. Simulating prosthetic vision in normal-vision observers, previous studies report good face recognition ability using tasks that allow recognition to be achieved on the basis of information that survives low resolution well, including basic category (sex, age) and extra-face information (hairstyle, glasses). Here, we test within-category individuation for face-only information (e.g., distinguishing between multiple Caucasian young men with hair covered). Under these conditions, recognition was poor (although above chance) even for a simulated 40×40 array with all phosphene elements assumed functional, a resolution above the upper end of current-generation prosthetic implants. This indicates that a significant challenge is to develop methods to improve face identity recognition. Inspired by "bionic ear" improvements achieved by altering signal input to match high-level perceptual (speech) requirements, we test a high-level perceptual enhancement of face images, namely face caricaturing (exaggerating identity information away from an average face). Results show caricaturing improved identity recognition in memory and/or perception (degree by which two faces look dissimilar) down to a resolution of 32×32 with 30% phosphene dropout. Findings imply caricaturing may offer benefits for patients at resolutions realistic for some current-generation or in-development implants.


Subject(s)
Caricatures as Topic , Facial Recognition/physiology , Visual Prosthesis , Female , Humans , Male , Memory, Short-Term/physiology , Photic Stimulation , Reaction Time , Young Adult
2.
Invest Ophthalmol Vis Sci ; 58(7): 3231-3239, 2017 06 01.
Article in English | MEDLINE | ID: mdl-28660276

ABSTRACT

Purpose: With a retinal prosthesis connected to a head-mounted camera, subjects can perform low vision tasks using a combination of electrode discrimination and head-directed localization. The objective of the present study was to investigate the contribution of retinotopic electrode discrimination (perception corresponding to the arrangement of the implanted electrodes with respect to their position beneath the retina) to visual performance for three recipients of a 24-channel suprachoroidal retinal implant. Proficiency in retinotopic discrimination may allow good performance with smaller head movements, and identification of this ability would be useful for targeted rehabilitation. Methods: Three participants with retinitis pigmentosa performed localization and grating acuity assessments using a suprachoroidal retinal prosthesis. We compared retinotopic and nonretinotopic electrode mapping and hypothesized that participants with measurable acuity in a normal retinotopic condition would be negatively impacted by the nonretinotopic condition. We also expected that participants without measurable acuity would preferentially use head movement over retinotopic information. Results: Only one participant was able to complete the grating acuity task. In the localization task, this participant exhibited significantly greater head movements and significantly lower localization scores when using the nonretinotopic electrode mapping. There was no significant difference in localization performance or head movement for the remaining two subjects when comparing retinotopic to nonretinotopic electrode mapping. Conclusions: Successful discrimination of retinotopic information is possible with a suprachoroidal retinal prosthesis. Head movement behavior during a localization task can be modified using a nonretinotopic mapping. Behavioral comparisons using retinotopic and nonretinotopic electrode mapping may be able to highlight deficiencies in retinotopic discrimination, with a view to address these deficiencies in a rehabilitation environment. (ClinicalTrials.gov number, NCT01603576).


Subject(s)
Blindness/rehabilitation , Electrodes, Implanted , Retinitis Pigmentosa/complications , Visual Prosthesis , Blindness/physiopathology , Evoked Potentials, Visual/physiology , Female , Head Movements , Humans , Male , Middle Aged , Retinitis Pigmentosa/physiopathology , Visual Acuity/physiology
3.
J Neural Eng ; 13(3): 036013, 2016 06.
Article in English | MEDLINE | ID: mdl-27108845

ABSTRACT

OBJECTIVE: One strategy to improve the effectiveness of prosthetic vision devices is to process incoming images to ensure that key information can be perceived by the user. This paper presents the first comprehensive results of vision function testing for a suprachoroidal retinal prosthetic device utilizing of 20 stimulating electrodes. Further, we investigate whether using image filtering can improve results on a light localization task for implanted participants compared to minimal vision processing. No controlled implanted participant studies have yet investigated whether vision processing methods that are not task-specific can lead to improved results. APPROACH: Three participants with profound vision loss from retinitis pigmentosa were implanted with a suprachoroidal retinal prosthesis. All three completed multiple trials of a light localization test, and one participant completed multiple trials of acuity tests. The visual representations used were: Lanczos2 (a high quality Nyquist bandlimited downsampling filter); minimal vision processing (MVP); wide view regional averaging filtering (WV); scrambled; and, system off. MAIN RESULTS: Using Lanczos2, all three participants successfully completed a light localization task and obtained a significantly higher percentage of correct responses than using MVP ([Formula: see text]) or with system off ([Formula: see text]). Further, in a preliminary result using Lanczos2, one participant successfully completed grating acuity and Landolt C tasks, and showed significantly better performance ([Formula: see text]) compared to WV, scrambled and system off on the grating acuity task. SIGNIFICANCE: Participants successfully completed vision tasks using a 20 electrode suprachoroidal retinal prosthesis. Vision processing with a Nyquist bandlimited image filter has shown an advantage for a light localization task. This result suggests that this and targeted, more advanced vision processing schemes may become important components of retinal prostheses to enhance performance. ClinicalTrials.gov Identifier: NCT01503576.


Subject(s)
Choroid/physiology , Vision, Ocular/physiology , Visual Prosthesis , Blindness/psychology , Blindness/rehabilitation , Electrodes, Implanted , Female , Humans , Light , Male , Middle Aged , Psychomotor Performance , Retinitis Pigmentosa/psychology , Retinitis Pigmentosa/rehabilitation , Treatment Outcome , Vision Disorders/psychology , Vision Disorders/rehabilitation , Visual Acuity , Visual Perception
4.
Article in English | MEDLINE | ID: mdl-22256201

ABSTRACT

Navigation and way finding including obstacle avoidance is difficult when visual perception is limited to low resolution, such as is currently available on a bionic eye. Depth visualisation may be a suitable alternative. Such an approach can be evaluated using simulated phosphenes with a wearable mobile virtual reality kit. In this paper, we present two novel approaches: (i) an implementation of depth visualisation; and, (ii) novel methods for rapid rendering of simulated phosphenes with an empirical comparison between them. Our new software-based method for simulated phosphene rendering shows large speed improvements, facilitating the display in real-time of a large number of phosphenes with size and brightness dependent on pixel intensity, and with customised output dynamic range. Further, we describe the protocol, navigation environment and system used for visual navigation experiments to evaluate the use of depth on low resolution simulations of a bionic eye perceptual experience. Results for these experiments show that a depth-based representation is effective for navigation, and shows significant advantages over intensity-based approaches when overhanging obstacles are present. The results of the experiments were reported in [1], [2].


Subject(s)
Depth Perception/physiology , Movement/physiology , Phosphenes/physiology , Vision, Low/physiopathology , Algorithms , Female , Humans , Male , Normal Distribution , Time Factors , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...