Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Am Heart J ; 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38838970

ABSTRACT

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, p=0.33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 p=0.46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, p=0.04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, p=0.02), reduced SVi (34.2 vs 38 ml/m2, p<0.01) and transaortic flow rate (190.6 vs 211 ml/s, p<0.01). At pre-discharge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, p<0.01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, p=0.03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs.44 IQR 35-59 in those without, p=0.02)). No evidence of a significant impact of PPM on overall (p=0.71) and CV (p=0.70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, p=0.03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, p<0.001) and LVOT diameter (OR 0.79, 0.65-0.95, p=0.01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.

2.
Am J Cardiol ; 216: 9-18, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38301755

ABSTRACT

Ultrathin-strut drug-eluting stents (DES) have been related to potential improvement in stent-related outcomes compared with thicker-struts DES. However, comparisons among different ultrathin devices are lacking. All randomized controlled trials comparing ultrathin (struts thickness <70 µm) and thicker-struts DESs in an all-comers population were included. Target lesion failure (TLF), as defined by included trials, at 1-year follow-up was the primary end point. Overall mortality, myocardial infarction, target lesion revascularization (TLR), and stent thrombosis were the secondary end points. Arms of included trials were compared using network meta-analysis. Nine studies encompassing 20,081 patients were included, of which 9,509 patients had an ultrathin DES: Orsiro (evaluated in 7 arms with 8,086 patients), MiStent (1 arm with 703 patients), or Supraflex (1 arm with 720 patients). At 1-year follow-up, no significant differences were noted for TLF among these ultrathin DES. In particular, Orsiro was associated with a similar risk of TLF compared with Supraflex (risk rate 1.07, 95% confidence interval 0.59 to 1.78) and showed the highest probability of performing best in terms of TLF, myocardial infarction, and TLR. Ultrathin DES are all associated with a comparable risk of TLF compared with thicker-strut DES. In terms of TLR and TLF risk, Orsiro was the one with the highest probability of best performances, either compared with other ultrathin DES or to devices with thicker struts.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , Humans , Sirolimus , Network Meta-Analysis , Risk Factors , Absorbable Implants , Prosthesis Design , Treatment Outcome , Myocardial Infarction/epidemiology , Myocardial Infarction/surgery , Stents , Coronary Artery Disease/surgery
3.
Minerva Cardiol Angiol ; 72(1): 87-94, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37405712

ABSTRACT

BACKGROUND: Even if prevalent among patients with severe aortic stenosis (AS), the clinical suspicion for transthyretin cardiac amyloidosis (ATTR-CA) remains difficult in this subset. We report our single center experience on ATTR-CA detection among TAVR candidates to provide insights on the prevalence and clinical features of dual pathology as compared to lone AS. METHODS: Consecutive severe AS patients undergoing transcatheter aortic valve replacement (TAVR) evaluation at a single center were prospectively included. Those with suspected ATTR-CA based on clinical assessment underwent 99m Tc-3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) bone scintigraphy. The RAISE score, a novel screening tool with high sensitivity for ATTR-CA in AS, was retrospectively calculated to rule-out ATTR-CA in the remaining patients. Patients were categorized as follow: "ATTR-CA+": patients with confirmed ATTR-CA at DPD bone scintigraphy; "ATTR-CA-": patients with negative DPD bone scintigraphy or a negative RAISE score; "ATTR-CA indeterminate": patients not undergoing ATTR-CA assessment with a positive RAISE score. The characteristics of ATTR-CA+ and ATTR-CA- patients were compared. RESULTS: Of 107 included patients, ATTR-CA suspicion was posed in 13 patients and confirmed in six. Patients were categorized as follow: 6 (5.6%) ATTR-CA+, 79 (73.8%) ATTR-CA-, 22 (20.6%) ATTR-CA indeterminate. Excluding ATTR-CA indeterminate patients, the prevalence of ATTR-CA was 7.1% (95% CI 2.6-14.7%). As compared to ATTR-CA - patients, ATTR-CA + patients were older, had higher procedural risk and more extensive myocardial and renal damage. They had higher left ventricle mass index and lower ECG voltages, translating into a lower voltage to mass ratio. Moreover, we describe for the first time bifascicular block as an ECG feature highly specific of patients with dual pathology (50.0% vs. 2.7%, P<0.001). Of note, pericardial effusion was rarely found in patients with lone AS (16.7% vs. 1.2%, P=0.027). No difference in procedural outcomes was observed between groups. CONCLUSIONS: Among severe AS patients, ATTR-CA is prevalent and presents with phenotypic features that may aid to differentiate it from lone AS. A clinical approach based on routine search of amyloidosis features might lead to selective DPD bone scintigraphy with a satisfactory positive predictive value.


Subject(s)
Amyloid Neuropathies, Familial , Aortic Valve Stenosis , Cardiomyopathies , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Prealbumin , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/epidemiology , Cardiomyopathies/surgery , Amyloid Neuropathies, Familial/complications , Amyloid Neuropathies, Familial/epidemiology , Amyloid Neuropathies, Familial/surgery , Retrospective Studies , Tomography, X-Ray Computed , Aortic Valve Stenosis/epidemiology , Aortic Valve Stenosis/surgery
4.
JACC Cardiovasc Imaging ; 16(12): 1584-1604, 2023 12.
Article in English | MEDLINE | ID: mdl-37804276

ABSTRACT

BACKGROUND: The clinical value of high-risk coronary plaque characteristics (CPCs) to inform intensified medical therapy or revascularization of non-flow-limiting lesions remains uncertain. OBJECTIVES: The authors performed a systematic review and meta-analysis to study the prognostic impact of CPCs on patient-level and lesion-level major cardiovascular adverse events (MACE). METHODS: Thirty studies (21 retrospective, 9 prospective) with 30,369 patients evaluating the association of CPCs with MACE were included. CPCs included high plaque burden, low minimal lumen area, thin cap fibroatheroma, high lipid core burden index, low-attenuation plaque, spotty calcification, napkin ring sign, and positive remodeling. RESULTS: CPCs were evaluated with the use of intracoronary modalities in 9 studies (optical coherence tomography in 4 studies, intravascular ultrasound imaging in 3 studies, and near-infrared spectroscopy intravascular ultrasound imaging in 2 studies) and by means of coronary computed tomographic angiography in 21 studies. CPCs significantly predicted patient-level and lesion-level MACE in both unadjusted and adjusted analyses. For most CPCs, accuracy for MACE was modest to good at the patient level and moderate to good at the lesion level. Plaques with more than 1 CPC had the highest accuracy for lesion-level MACE (AUC: 0.87). Because the prevalence of CPCs among plaques was low, estimated positive predictive values for lesion-level MACE were modest. Results were mostly consistent across imaging modalities and clinical presentations, and in studies with prevailing hard outcomes. CONCLUSIONS: Characterization of CPCs identifies high-risk atherosclerotic plaques that place lesions and patients at risk for future MACE, albeit with modest sensitivity and positive predictive value (Coronary Plaque Characteristics Associated With Major Adverse Cardiovascular Events Among Atherosclerotic Patients and Lesions; CRD42021251810).


Subject(s)
Coronary Artery Disease , Plaque, Atherosclerotic , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/complications , Coronary Angiography/methods , Retrospective Studies , Prospective Studies , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Predictive Value of Tests , Ultrasonography, Interventional
5.
J Clin Med ; 12(3)2023 Feb 03.
Article in English | MEDLINE | ID: mdl-36769866

ABSTRACT

Transcatheter aortic valve implantation (TAVI) is the established first-line treatment for patient with severe aortic stenosis not suitable for surgery. Echocardiographic evaluation of hemodynamic forces (HDFs) is a growing field, holding the potential to early predict improvement in LV function. A prospective observational study was conducted. Transthoracic echocardiography was performed before and after TAVI. HDFs were analyzed along with traditional left ventricular (LV) function parameters. Twenty-five consecutive patients undergoing TAVI were enrolled: mean age 83 ± 5 years, 74.5% male, mean LV Ejection Fraction (LVEF) at baseline 57 ± 8%. Post-TAVI echocardiographic evaluation was performed 2.4 ± 1.06 days after the procedure. HDF amplitude parameters improved significantly after the procedure: LV Longitudinal Forces (LF) apex-base [mean difference (MD) 1.79%; 95% CI 1.07-2.5; p-value < 0.001]; LV systolic LF apex-base (MD 2.6%; 95% CI 1.57-3.7; p-value < 0.001); LV impulse (LVim) apex-base (MD 2.9%; 95% CI 1.48-4.3; p-value < 0.001). Similarly, HDFs orientation parameters improved: LVLF angle (MD 1.5°; 95% CI 0.07-2.9; p-value = 0.041); LVim angle (MD 2.16°; 95% CI 0.76-3.56; p-value = 0.004). Conversely, global longitudinal strain and LVEF did not show any significant difference before and after the procedure. Echocardiographic analysis of HDFs could help differentiate patients with LV function recovery after TAVI from patients with persistent hemodynamic dysfunction.

6.
Eur Heart J Cardiovasc Imaging ; 24(8): 1052-1061, 2023 07 24.
Article in English | MEDLINE | ID: mdl-36752044

ABSTRACT

AIMS: The prognostic impact of flow trajectories according to stroke volume index (SVi) and transvalvular flow rate (FR) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) remains poorly assessed. We evaluated and compared SVi and FR prior and after TAVR for severe AS. METHODS AND RESULTS: Patients were categorized according to SVi (<35 mL/m2) and FR (<200 mL/s). The association of pre- and post-TAVR SVi and FR with all-cause mortality up to 3 years was assessed with multivariable Cox regression models. Among 980 patients with pre-TAVR flow assessment, SVi was reduced in 41.3% and FR in 48.1%. Baseline flow status was not an independent mortality predictor [SVi: hazard ratio (HR) 1.22, 95% confidence interval (CI) 0.85-1.82, FR: HR 0.78, 95% CI 0.48-1.27]. Among 731 patients undergoing early (5 days, interquartile range 2-29) post-TAVR flow assessment, SVi recovered in 40.1% and FR in 49.0% patients with baseline low flow. Reduced FR following TAVR was an independent predictor of mortality (HR 1.67, 95% CI 1.02-2.74), whereas SVi was not (HR 0.97, 95% CI 0.53-1.78). Three-year estimated mortality in patients with recovered FR was lower than that in patients with reduced FR (13.3 vs. 37.7% vs, P = 0.003) and similar to that in patients with normal baseline FR (P = 0.317). CONCLUSION: Baseline flow status was not an independent predictor of mid-term mortality among all-comers with severe AS undergoing TAVR. Flow recovery early after TAVR was frequent. Post-TAVR FR, but not SVi, was independently associated with mid-term all-cause mortality. By impacting flow status, AV replacement modifies the association of flow status with outcomes.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Stroke Volume , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Risk Factors , Retrospective Studies , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Severity of Illness Index
7.
J Cardiovasc Comput Tomogr ; 16(3): 207-214, 2022.
Article in English | MEDLINE | ID: mdl-34896066

ABSTRACT

BACKGROUND: The adoption of Computed tomography (CT)-defined sarcopenia to risk stratify transcatheter aortic valve implantation (TAVI) candidates remains limited by a lack of both standardized definition and evidence of independent value over currently adopted mortality prediction tools. METHODS: 391 consecutive TAVI patients with pre-procedural CT scan were included (81 â€‹± â€‹6 years, 57.5% male, STS-PROM score 4.4 â€‹± â€‹3.6%) and abdominal muscle retrospectively quantified. The two definitions of radiologic sarcopenia previously adopted in TAVI studies were compared (psoas muscle area [PMA] at the L4 vertebra level: "PMA-sarcopenia"; indexed skeletal muscle area at the L3 vertebra level: "SMI-sarcopenia"). The primary endpoint was longer available-term all-cause mortality. Secondary endpoints were Valve Academic Research Consortium-2-defined in-hospital and 30-day outcomes. RESULTS: SMI- and PMA-sarcopenia were present in 192 (49.1%) and 117 (29.9%) patients, respectively. After a median of 24 (12-30) months follow-up, 83 (21.2%) patients died. PMA-(adj-HR 1.81, 95%CI 1.12-2.93, p â€‹= â€‹0.015), but not SMI-sarcopenia (adj-HR 1.23, 95%CI 0.76-2.00, p â€‹= â€‹0.391), was associated with all-cause mortality independently of age, sex and in-study outcome predictors (atrial fibrillation, hemoglobin, history of peripheral artery disease, cancer and subcutaneous adipose tissue). PMA-defined sarcopenia provided additive prognostic value over current post-TAVI mortality risk estimators including STS-PROM (p â€‹= â€‹0.001), Euroscore II (p â€‹= â€‹0.025), Charlson index (p â€‹= â€‹0.025) and TAVI2-score (p â€‹= â€‹0.020). Device success, early safety, clinical efficacy and 30-day all-cause death were unaffected by sarcopenia status regardless of definition. CONCLUSIONS: PMA-sarcopenia (but not SMI-sarcopenia) is predictive of 2 year mortality among TAVI patients. The prognostic information provided by PMA-sarcopenia is independent of the tools currently adopted to predict post-TAVI mortality in clinical practice.


Subject(s)
Aortic Valve Stenosis , Sarcopenia , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Humans , Male , Predictive Value of Tests , Psoas Muscles/diagnostic imaging , Retrospective Studies , Risk Factors , Sarcopenia/diagnostic imaging , Tomography, X-Ray Computed/methods , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...