Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 45
Filter
1.
Acad Radiol ; 2024 Sep 10.
Article in English | MEDLINE | ID: mdl-39261231

ABSTRACT

Soft tissue sarcomas (STS) are a heterogeneous group of rare malignant tumors. Tumor grade might be underestimated in biopsy due to intratumoral heterogeneity. This mini-review aims to present the current state of predicting malignancy grades of STS through radiomics, machine learning, and deep learning on magnetic resonance imaging (MRI). Several studies investigated various machine-learning and deep-learning approaches in T2-weighted (w) images, contrast-enhanced (CE) T1w images, and DWI/ADC maps with promising results. Combining semantic imaging features, radiomics features, and deep-learning signatures in machine-learning models has demonstrated superior predictive performances compared to individual feature sources. Furthermore, incorporating features from both tumor volume and peritumor region is beneficial. Especially random forest and support vector machine classifiers, often combined with the least absolute shrinkage and selection operator (LASSO) and/or synthetic minority oversampling technique (SMOTE), did show high area under the curve (AUC) values and accuracies in existing studies.

2.
Magn Reson Med ; 92(6): 2464-2472, 2024 Dec.
Article in English | MEDLINE | ID: mdl-39119819

ABSTRACT

PURPOSE: The semisolid myelin sheath has very fast transverse relaxation and is invisible to conventional MRI sequences. UTE sequences can detect signal from myelin. The major challenge is the concurrent detection of various water components. METHODS: The inversion recovery (IR)-based UTE (IR-UTE) sequence employs an adiabatic inversion pulse to invert and suppress water magnetizations. TI plays a key role in water suppression, with negative water magnetizations (negative phase) before the null point and positive water magnetizations (positive phase) after the null point. A series of dual-echo IR-UTE images were acquired with different TIs to detect water phase transition. The effects of TR in phase transition and water suppression were also investigated using a relatively long TR of 500 ms and a short TR of 106 ms. The water phase transition in dual-echo IR-UTE imaging of myelin was investigated in five ex vivo and five in vivo human brains. RESULTS: An apparent phase transition was observed in the second echo at the water signal null point, where the myelin signal was selectively detected by the UTE data acquisition at the optimal TI. The water phase transition point varied significantly across the brain when the long TR of 500 ms was used, whereas the convergence of TIs was observed when the short TR of 106 ms was used. CONCLUSION: The results suggest that the IR-UTE sequence with a short TR allows uniform inversion and nulling of water magnetizations, thereby providing volumetric imaging of myelin.


Subject(s)
Imaging, Three-Dimensional , Magnetic Resonance Imaging , Myelin Sheath , Myelin Sheath/chemistry , Humans , Magnetic Resonance Imaging/methods , Imaging, Three-Dimensional/methods , Brain/diagnostic imaging , Water/chemistry , Algorithms , Phase Transition , Body Water/diagnostic imaging , Body Water/chemistry , Image Interpretation, Computer-Assisted/methods , Male , Female , Adult , Reproducibility of Results , Image Enhancement/methods
3.
Article in English | MEDLINE | ID: mdl-39198129

ABSTRACT

PURPOSE: Correction of bony mandibular defects is a challenge in oral and maxillofacial surgery due to aesthetic and functional requirements. This study investigated the potential of a novel hybrid scaffold for bone regeneration and degradation assessment of the ceramic within the omentum majus over 6 months and the extent to which rhBMP-2 as a growth factor, alone or combined with a hydrogel, affects regeneration. MATERIALS AND METHODS: In this animal study, 10 Göttingen minipigs each had one scaffold implanted in the greater omentum. Five animals had scaffolds loaded with a collagen hydrogel and rhBMP-2, and the other five animals (control group) had scaffolds loaded with rhBMP-2 only. Fluorochrome injections and computed tomography (CT) were performed regularly. After 6 months, the animals were euthanized, and samples were collected for microCT and histological evaluations. RESULTS: Fluorescent and light microscopic and a CT morphological density evaluation showed continuous bone growth until week 16 in both groups. Regarding the ratio of bone attachment to the Zr02 support struts, the rhBMP-2 loaded collagen hydrogel group showed with 63% a significantly higher attachment (p > 0.001) than the rhBMP-2 control group (49%). CONCLUSION: In this study, bone growth was induced in all omentum majus specimens until post-operative week 16. Furthermore, hydrogel and rhBMP-2 together resulted in better bone-scaffold integration than rhBMP-2 alone. Further studies should investigate whether implantation of the scaffolds in the jaw after an appropriate period of bone regeneration leads to a stable situation and the desired results.

4.
Radiologie (Heidelb) ; 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-39020050

ABSTRACT

BACKGROUND: A recent innovation in computed tomography (CT) imaging has been the introduction of photon-counting detector CT (PCD-CT) systems, which are able to register the number and the energy level of incoming x­ray photons and have smaller detector elements compared with conventional CT scanners that operate with energy-integrating detectors (EID-CT). OBJECTIVES: The study aimed to evaluate the potential benefits of a novel, non-CE certified PCD-CT in detecting myeloma-associated osteolytic bone lesions (OL) compared with a state-of-the-art EID-CT. MATERIALS AND METHODS: Nine patients with multiple myeloma stage III (according to Durie and Salmon) underwent magnetic resonance imaging (MRI), EID-CT, and PCD-CT of the lower lumbar spine and pelvis. The PCD-CT and EID-CT images of all myeloma lesions that were visible in clinical MRI scans were reviewed by three radiologists for corresponding OL. Additionally, the visualization of destructions to cancellous or cortical bone, and trabecular structures, was compared between PCD-CT and EID-CT. RESULTS: Readers detected 21% more OL in PCD-CT than in EID-CT images (138 vs. 109; p < 0.0001). The sensitivity advantage of PCD-CT in lesion detection increased with decreasing lesion size. The visualization quality of cancellous and cortical destructions as well as of trabecular structures was rated higher by all three readers in PCD-CT images (mean image quality improvements for PCD-CT over EID-CT were +0.45 for cancellous and +0.13 for cortical destructions). CONCLUSIONS: For myeloma-associated OL, PCD-CT demonstrated significantly higher sensitivity, especially with small size. Visualization of bone tissue and lesions was considered significantly better in PCD-CT than in EID-CT. This implies that PCD-CT scanners could potentially be used in the early detection of myeloma-associated bone lesions.

5.
Ann Biomed Eng ; 52(9): 2316-2318, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38849691

ABSTRACT

Increasing population and healthcare costs make changes in the healthcare system necessary. This article deals with ChatGPT's perspective on the future role of radiologists in the AI-driven hospital. This perspective will be augmented by further considerations by the author. AI-based imaging technologies and chatbots like ChatGPT can help improve radiologists' performance and workflow in the future AI-driven hospital. Although basic radiological examinations could be delivered without needing a radiologist, sophisticated imaging procedures will still need the expert opinion of a radiologist.


Subject(s)
Artificial Intelligence , Radiologists , Humans , Hospitals
6.
Eur J Radiol ; 177: 111548, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38852328

ABSTRACT

PURPOSE: Systematic reviews on the grading of STS using MRI are lacking. This review analyses the role of different MRI features in inferring the histological grade of STS. MATERIALS AND METHODS: A systematic review was conducted and is reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) checklist. The electronic databases of PubMed/MEDLINE were systematically searched for literature addressing the correlation of MRI findings in soft tissue sarcoma with tumor grade. As keywords "MRI", "magnetic resonance imaging", "sarcoma", "grade", "grading", and "FNCLCC" have been selected. RESULTS: 14 studies have been included in this systematic review. Tumor size (p = 0.015 (51 patients) to p = 0.81 (36 patients)), tumor margin (p < 0.001 (95 patients) to 0.93 (36 patients)), necrosis (p = 0.004 (50 patients) to p = 0.65 (95 patients)), peritumoral edema (p = 0.002 (130 patients) to p = 0.337 (40 patients)), contrast enhancement (p < 0.01 (50 patients) to 0.019 (51 patients)) and polycyclic/multilobulated tumor configuration (p = 0.008 (71 patients)) were significantly associated with STS malignancy grade in most of the included studies. Heterogeneity in T2w images (p = 0.003 (130 patients) to 0.202 (40 patients)), signal intensity in T1w images/ hemorrhage (p = 0.02 (130 patients) to 0.5 (31 patients)), peritumoral contrast enhancement (p < 0.001 (95 patients) to 0.253 (51 patients)) and tumoral diffusion restriction (p = 0.01 (51 patients) to 0.53 (52 patients)) were regarded as significantly associated with FNCLCC grade in some of the studies which investigated these features. Most other MRI features were not significant. CONCLUSION: Several MRI features, such as tumor size, necrosis, peritumoral edema, peritumoral contrast enhancement, intratumoral contrast enhancement, and polycyclic/multilobulated tumor configuration may indicate the malignancy grade of STS. However, further studies are needed to gain consensus.


Subject(s)
Magnetic Resonance Imaging , Neoplasm Grading , Sarcoma , Humans , Magnetic Resonance Imaging/methods , Sarcoma/diagnostic imaging , Sarcoma/pathology , Soft Tissue Neoplasms/diagnostic imaging , Soft Tissue Neoplasms/pathology , Sensitivity and Specificity , Reproducibility of Results
7.
Clin Kidney J ; 17(6): sfae101, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38915436

ABSTRACT

Background: The aim of this work was to create and evaluate a preoperative non-contrast-enhanced (CE) magnetic resonance imaging (MRI)/angiography (MRA) protocol to assess renal function and visualize renal arteries and any abnormalities in potential living kidney donors. Methods: In total, 28 subjects were examined using scintigraphy to determine renal function. In addition, 3D-pseudocontinuous arterial spin labeling (pCASL), a 2D-non-CE electrocardiogram-triggered radial quiescent interval slice-selective (QISS-MRA), and 4D-CE time-resolved angiography with interleaved stochastic trajectories (CE-MRA) were performed to assess renal perfusion, visualize renal arteries and detect any abnormalities. Two glomerular filtration rates [described by Gates (GFRG) and according to the Chronic Kidney Disease Epidemiology Collaboration formula (GFRCKD-EPI)]. The renal volumes were determined using both MRA techniques. Results: The mean value of regional renal blood flow (rRBF) on the right side was significantly higher than that on the left. The agreements between QISS-MRA and CE-MRA concerning the assessment of absence or presence of an aberrant artery and renal arterial stenosis were perfect. The mean renal volumes measured in the right kidney with QISS-MRA were lower than the corresponding values of CE-MRA. In contrast, the mean renal volumes measured in the left kidney with both MRA techniques were similar. The correlation between the GFRG and rRBF was compared in the same manner as that between GFRCKD-EPI and rRBF. Conclusion: The combination of pCASL and QISS-MRA constitute a reliable preoperative protocol with a total measurement time of <10 min without the potential side effects of gadolinium-based contrast agents or radiation exposure.

9.
J Am Coll Radiol ; 21(9): 1330, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38527642
10.
Eur J Radiol ; 173: 111364, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38364589

ABSTRACT

PURPOSE: We developed and tested a neural network for automated detection and stability analysis of vertebral body fractures on computed tomography (CT). MATERIALS AND METHODS: 257 patients who underwent CT were included in this Institutional Review Board (IRB) approved study. 463 fractured and 1883 non-fractured vertebral bodies were included, with 190 fractures unstable. Two readers identified vertebral body fractures and assessed their stability. A combination of a Hierarchical Convolutional Neural Network (hNet) and a fracture Classification Network (fNet) was used to build a neural network for the automated detection and stability analysis of vertebral body fractures on CT. Two final test settings were chosen: one with vertebral body levels C1/2 included and one where they were excluded. RESULTS: The mean age of the patients was 68 ± 14 years. 140 patients were female. The network showed a slightly higher diagnostic performance when excluding C1/2. Accordingly, the network was able to distinguish fractured and non-fractured vertebral bodies with a sensitivity of 75.8 % and a specificity of 80.3 %. Additionally, the network determined the stability of the vertebral bodies with a sensitivity of 88.4 % and a specificity of 80.3 %. The AUC was 87 % and 91 % for fracture detection and stability analysis, respectively. The sensitivity of our network in indicating the presence of at least one fracture / one unstable fracture within the whole spine achieved values of 78.7 % and 97.2 %, respectively, when excluding C1/2. CONCLUSION: The developed neural network can automatically detect vertebral body fractures and evaluate their stability concurrently with a high diagnostic performance.


Subject(s)
Spinal Fractures , Vertebral Body , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Retrospective Studies , Spine , Spinal Fractures/diagnostic imaging , Tomography, X-Ray Computed/methods , Artificial Intelligence
11.
Skeletal Radiol ; 53(5): 881-890, 2024 May.
Article in English | MEDLINE | ID: mdl-37935923

ABSTRACT

PURPOSE: To investigate the feasibility and application of a novel imaging technique, a three-dimensional dual adiabatic inversion recovery prepared ultrashort echo time (3D DIR-UTE) sequence, for high contrast assessment of cartilaginous endplate (CEP) imaging with head-to-head comparisons between other UTE imaging techniques. METHOD: The DIR-UTE sequence employs two narrow-band adiabatic full passage (AFP) pulses to suppress signals from long T2 water (e.g., nucleus pulposus (NP)) and bone marrow fat (BMF) independently, followed by multispoke UTE acquisition to detect signals from the CEP with short T2 relaxation times. The DIR-UTE sequence, in addition to three other UTE sequences namely, an IR-prepared and fat-saturated UTE (IR-FS-UTE), a T1-weighted and fat-saturated UTE sequence (T1w-FS-UTE), and a fat-saturated UTE (FS-UTE) was used for MR imaging on a 3 T scanner to image six asymptomatic volunteers, six patients with low back pain, as well as a human cadaveric specimen. The contrast-to-noise ratio of the CEP relative to the adjacent structures-specifically the NP and BMF-was then compared from the acquired images across the different UTE sequences. RESULTS: For asymptomatic volunteers, the DIR-UTE sequence showed significantly higher contrast-to-noise ratio values between the CEP and BMF (CNRCEP-BMF) (19.9 ± 3.0) and between the CEP and NP (CNRCEP-NP) (23.1 ± 1.7) compared to IR-FS-UTE (CNRCEP-BMF: 17.3 ± 1.2 and CNRCEP-NP: 19.1 ± 1.8), T1w-FS-UTE (CNRCEP-BMF: 9.0 ± 2.7 and CNRCEP-NP: 10.4 ± 3.5), and FS-UTE (CNRCEP-BMF: 7.7 ± 2.2 and CNRCEP-NP: 5.8 ± 2.4) for asymptomatic volunteers (all P-values < 0.001). For the spine sample and patients with low back pain, the DIR-UTE technique detected abnormalities such as irregularities and focal defects in the CEP regions. CONCLUSION: The 3D DIR-UTE sequence is able to provide high-contrast volumetric CEP imaging for human spines on a clinical 3 T scanner.


Subject(s)
Low Back Pain , Humans , Bone and Bones , Magnetic Resonance Imaging/methods , Cartilage , Phantoms, Imaging , Imaging, Three-Dimensional/methods
13.
J Craniomaxillofac Surg ; 52(1): 127-135, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38129185

ABSTRACT

The study aimed to analyze bone regeneration in critical-size defects using hybrid scaffolds biomechanically adapted to the specific defect and adding the growth factor rhBMP-2. For this animal study, ten minipigs underwent bilateral defects in the corpus mandibulae and were subsequently treated with novel cylindrical hybrid scaffolds. These scaffolds were designed digitally to suit the biomechanical requirements of the mandibular defect, utilizing finite element analysis. The scaffolds comprised zirconium dioxide-tricalcium phosphate (ZrO2-TCP) support struts and TCP foam ceramics. One scaffold in each animal was loaded with rhBMP-2 (100 µg/cm³), while the other served as an unloaded negative control. Fluorescent dyes were administered every 2 weeks, and computed tomography (CT) scans were conducted every 4 weeks. Euthanasia was performed after 3 months, and samples were collected for examination using micro-CT and histological evaluation of both hard and soft tissue. Intravital CT examinations revealed minor changes in radiographic density from 4 to 12 weeks postoperatively. In the group treated with rhBMP-2, radiographic density shifted from 2513 ± 128 (mean ± SD) to 2606 ± 115 Hounsfield units (HU), while the group without rhBMP-2 showed a change from 2430 ± 131 to 2601 ± 67 HU. Prior to implantation, the radiological density of samples measured 1508 ± 30 mg HA/cm³, whereas post-mortem densities were 1346 ± 71 mg HA/cm³ in the rhBMP-2 group and 1282 ± 91 mg HA/cm³ in the control group (p = 0.045), as indicated by micro-CT measurements. The histological assessment demonstrated successful ossification in all specimens. The newly formed bone area proportion was significantly greater in the rhBMP-2 group (48 ± 10%) compared with the control group without rhBMP-2 (42 ± 9%, p = 0.03). The mean area proportion of remaining TCP foam was 23 ± 8% with rhBMP-2 and 24 ± 10% without rhBMP-2. Successful bone regeneration was accomplished by implanting hybrid scaffolds into critical-size mandibular defects. Loading these scaffolds with rhBMP-2 led to enhanced bone regeneration and a uniform distribution of new bone formation within the hybrid scaffolds. Further studies are required to determine the adaptability of hybrid scaffolds for larger and potentially segmental defects in the maxillofacial region.


Subject(s)
Dental Implants , Swine , Animals , Swine, Miniature , Bone Regeneration , Mandible/diagnostic imaging , Mandible/surgery , Mandible/pathology , Bone Morphogenetic Protein 2/therapeutic use , Osteogenesis , Transforming Growth Factor beta/therapeutic use , Tissue Scaffolds , Recombinant Proteins/pharmacology , Recombinant Proteins/therapeutic use , Calcium Phosphates
14.
NMR Biomed ; 37(1): e5035, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37721094

ABSTRACT

The aim of the current study was to investigate the feasibility of three-dimensional ultrashort echo time quantitative susceptibility mapping (3D UTE-QSM) for the assessment of gadolinium (Gd) deposition in cortical bone. To this end, 40 tibial bovine cortical bone specimens were divided into five groups then soaked in phosphate-buffered saline (PBS) solutions with five different Gd concentrations of 0, 0.4, 0.8, 1.2, and 1.6 mmol/L for 48 h. Additionally, eight rabbits were randomly allocated into three groups, consisting of a normal-dose macrocyclic gadolinium-based contrast agent (GBCA) group (n = 3), a high-dose macrocyclic GBCA group (n = 3), and a control group (n = 2). All bovine and rabbit tibial bone samples underwent magnetic resonance imaging (MRI) on a 3-T clinical MR system. A 3D UTE-Cones sequence was utilized to acquire images with five different echo times (i.e., 0.032, 0.2, 0.4, 0.8, and 1.2 ms). The UTE images were subsequently processed with the morphology-enabled dipole inversion algorithm to yield a susceptibility map. The average susceptibility was calculated in three regions of interest in the middle of each specimen, and the Pearson's correlation between the estimated susceptibility and Gd concentration was calculated. The bone samples soaked in PBS with higher Gd concentrations exhibited elevated susceptibility values. A mean susceptibility value of -2.47 ± 0.23 ppm was observed for bovine bone soaked in regular PBS, while the mean QSM value increased to -1.75 ± 0.24 ppm for bone soaked in PBS with the highest Gd concentration of 1.6 mmol/L. A strong positive correlation was observed between Gd concentrations and QSM values. The mean susceptibility values of rabbit tibial specimens in the control group, normal-dose GBCA group, and high-dose GBCA group were -4.11 ± 1.52, -3.85 ± 1.33, and -3.39 ± 1.35 ppm, respectively. In conclusion, a significant linear correlation between Gd in cortical bone and QSM values was observed. The preliminary results suggest that 3D UTE-QSM may provide sensitive noninvasive assessment of Gd deposition in cortical bone.


Subject(s)
Gadolinium , Imaging, Three-Dimensional , Animals , Cattle , Rabbits , Bone and Bones/diagnostic imaging , Contrast Media , Cortical Bone/diagnostic imaging , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods
15.
NMR Biomed ; 37(1): e5040, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37740595

ABSTRACT

The purpose of this study is to investigate the use of ultrashort echo time (UTE) magnetic resonance imaging (MRI) techniques (T1 and magnetization transfer [MT] modeling) for imaging of the Achilles tendons and entheses in patients with psoriatic arthritis (PsA) compared with asymptomatic volunteers. The heels of twenty-six PsA patients (age 59 ± 15 years, 41% female) and twenty-seven asymptomatic volunteers (age 33 ± 11 years, 47% female) were scanned in the sagittal plane with UTE-T1 and UTE-MT modeling sequences on a 3-T clinical scanner. UTE-T1 and macromolecular proton fraction (MMF; the main outcome of MT modeling) were calculated in the tensile portions of the Achilles tendon and at the enthesis (close to the calcaneus bone). Mann-Whitney-U tests were used to examine statistically significant differences between the two cohorts. UTE-T1 in the entheses was significantly higher for the PsA group compared with the asymptomatic group (967 ± 145 vs. 872 ± 133 ms, p < 0.01). UTE-T1 in the tendons was also significantly higher for the PsA group (950 ± 145 vs. 850 ± 138 ms, p < 0.01). MMF in the entheses was significantly lower in the PsA group compared with the asymptomatic group (15% ± 3% vs. 18% ± 3%, p < 0.01). MMF in the tendons was also significantly lower in the PsA group compared with the asymptomatic group (17% ± 4% vs. 20% ± 5%, p < 0.01). Percentage differences in MMF between the asymptomatic and PsA groups (-16.6% and -15.0% for the enthesis and tendon, respectively) were higher than the T1 differences (10.8% and 11.7% for the enthesis and tendon, respectively). The results suggest higher T1 and lower MMF in the Achilles tendons and entheses in PsA patients compared with the asymptomatic group. This study highlights the potential of UTE-T1 and UTE-MT modeling for quantitative evaluation of entheses and tendons in PsA patients.


Subject(s)
Achilles Tendon , Arthritis, Psoriatic , Humans , Female , Adult , Middle Aged , Aged , Young Adult , Male , Achilles Tendon/diagnostic imaging , Arthritis, Psoriatic/diagnostic imaging , Arthritis, Psoriatic/pathology , Magnetic Resonance Imaging/methods , Protons
17.
Diagnostics (Basel) ; 13(17)2023 Aug 24.
Article in English | MEDLINE | ID: mdl-37685282

ABSTRACT

BACKGROUND: Detecting bone marrow edema (BME) as a sign of acute fractures is challenging on conventional computed tomography (CT). This study evaluated the diagnostic performance of a three-material decomposition (TMD) approach for detecting traumatic BME of the extremities on spectral computed tomography (SCT). METHODS: This retrospective diagnostic study included 81 bone compartments with and 80 without BME. A TMD application to visualize BME was developed in collaboration with Philips Healthcare. The following bone compartments were included: distal radius, proximal femur, proximal tibia, distal tibia and fibula, and long bone diaphysis. Two blinded radiologists reviewed each case independently in random order for the presence or absence of BME. RESULTS: The interrater reliability was 0.84 (p < 0.001). The different bone compartments showed sensitivities of 86.7% to 93.8%, specificities of 84.2% to 94.1%, positive predictive values of 82.4% to 94.7%, negative predictive values of 87.5% to 93.3%, and area under the curve (AUC) values of 85.7% to 93.1%. The distal radius showed the highest sensitivity and the proximal femur showed the lowest sensitivity, while the proximal femur presented the highest specificity and the distal tibia presented the lowest specificity. CONCLUSIONS: Our TMD approach provides high diagnostic performance for detecting BME of the extremities. Therefore, this approach could be used routinely in the emergency setting.

18.
Pol J Radiol ; 88: e325-e330, 2023.
Article in English | MEDLINE | ID: mdl-37576379

ABSTRACT

Purpose: Simple MRI features are mandatory to facilitate the diagnostics of synovial sarcomas, especially for radiolo-gists outside multidisciplinary sarcoma centres. In this case-series and review, we investigate the main appearance of synovial sarcoma on MRI. Material and methods: Fifteen histologically proven primary synovial sarcomas who underwent MRI at 2 different sarcoma centres were included in this case series. Patients and their primary synovial sarcomas were examined for age, localization, mean tumour size (in mm), histological grade (G - according to the Fédération Nationale des Centres de Lutte Contre Le Cancer [FNCLCC]), configuration, T2 signal intensity, presence/absence of "triple sign", heterogeneity/homogeneity, borders (well-defined or infiltrative), and intensity of contrast enhancement on MRI. Additionally, a comprehensive literature review to identify observational studies, reviews, and case-reports assessing MRI features of primary synovial sarcoma was performed. Results: The mean age of the patients was 47.6 years (SD: 17.2). The mean size of primary synovial sarcoma was 59.3 mm (SD: 42). Primary synovial sarcomas were significantly most often multilobulated (n = 12, p < 0.01), heterogeneous (n = 10), and infiltrative (n = 9). Additionally, 3 other primary synovial sarcomas showed the following configurations: ovoid/nodular (n = 2) and fascicular (n = 1). Ovoid/nodular synovial sarcomas were solely depicted as homogeneous with well-defined borders. All tumours showed T2 hyperintense signal and presented with marked contrast enhancement. Conclusions: Primary synovial sarcomas are mainly multilobulated, heterogeneous, and infiltrative tumours. In minor cases, ovoid/nodular or fascicular configurations occur. Knowing the main appearance of synovial sarcoma can help facilitate the diagnostics of primary synovial sarcomas.

19.
J Neurol ; 270(11): 5131-5154, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37535100

ABSTRACT

BACKGROUND: Coronavirus disease 2019 (COVID-19) has been associated with nervous system involvement, with more than one-third of COVID-19 patients experiencing neurological manifestations. Utilizing a systematic review, this study aims to summarize brain MRI findings in COVID-19 patients presenting with neurological symptoms. METHODS: Systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) checklist. The electronic databases of PubMed/MEDLINE, Embase, Scopus, and Web of Science were systematically searched for literature addressing brain MRI findings in COVID-19 patients with neurological symptoms. RESULTS: 25 publications containing a total number of 3118 COVID-19 patients with neurological symptoms who underwent MRI were included. The most common MRI findings and the respective pooled incidences in decreasing order were acute/subacute infarct (22%), olfactory bulb abnormalities (22%), white matter abnormalities (20%), cerebral microbleeds (17%), grey matter abnormalities (12%), leptomeningeal enhancement (10%), ADEM (Acute Disseminated Encephalomyelitis) or ADEM-like lesions (10%), non-traumatic ICH (10%), cranial neuropathy (8%), cortical gray matter signal changes compatible with encephalitis (8%), basal ganglia abnormalities (5%), PRES (Posterior Reversible Encephalopathy Syndrome) (3%), hypoxic-ischemic lesions (4%), venous thrombosis (2%), and cytotoxic lesions of the corpus callosum (2%). CONCLUSION: The present study revealed that a considerable proportion of patients with COVID-19 might harbor neurological abnormalities detectable by MRI. Among various findings, the most common MRI alterations are acute/subacute infarction, olfactory bulb abnormalities, white matter abnormalities, and cerebral microbleeds.

SELECTION OF CITATIONS
SEARCH DETAIL